Your browser doesn't support javascript.
loading
Pre-enrichment-free detection of hepatocellular carcinoma-specific ctDNA via PDMS and MEMS-based microfluidic sensor.
Çaglayan Arslan, Zeynep; Okan, Meltem; Külah, Haluk.
Affiliation
  • Çaglayan Arslan Z; Department of Electrical and Electronics Engineering, METU, Ankara, Turkey.
  • Okan M; METU MEMS Research and Application Center, Ankara, Turkey.
  • Külah H; Department of Micro and Nanotechnology, METU, Ankara, Turkey.
Mikrochim Acta ; 191(5): 229, 2024 04 02.
Article in En | MEDLINE | ID: mdl-38565645
ABSTRACT
The growing interest in microfluidic biosensors has led to improvements in the analytical performance of various sensing mechanisms. Although various sensors can be integrated with microfluidics, electrochemical ones have been most commonly employed due to their ease of miniaturization, integration ability, and low cost, making them an established point-of-care diagnostic method. This concept can be easily adapted to the detection of biomarkers specific to certain cancer types. Pathological profiling of hepatocellular carcinoma (HCC) is heterogeneous and rather complex, and biopsy samples contain limited information regarding the tumor and do not reflect its heterogeneity. Circulating tumor DNAs (ctDNAs), which can contain information regarding cancer characteristics, have been studied tremendously since liquid biopsy emerged as a new diagnostic method. Recent improvements in the accuracy and sensitivity of ctDNA determination also paved the way for genotyping of somatic genomic alterations. In this study, three-electrode (Au-Pt-Ag) glass chips were fabricated and combined with polydimethylsiloxane (PDMS) microchannels to establish an electrochemical microfluidic sensor for detecting c.747G > T hotspot mutations in the TP53 gene of ctDNAs from HCC. The preparation and analysis times of the constructed sensor were as short as 2 h in total, and a relatively high flow rate of 30 µl/min was used during immobilization and hybridization steps. To the best of our knowledge, this is the first time a PDMS-based microfluidic electrochemical sensor has been developed to target HCC ctDNAs. The system exhibited a limit of detection (LOD) of 24.1 fM within the tested range of 2-200 fM. The sensor demonstrated high specificity in tests conducted with fully noncomplementary and one-base mismatched target sequences. The developed platform is promising for detecting HCC-specific ctDNA at very low concentrations without requiring pre-enrichment steps.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Carcinoma, Hepatocellular / Micro-Electrical-Mechanical Systems / Liver Neoplasms Limits: Humans Language: En Journal: Mikrochim Acta Year: 2024 Type: Article Affiliation country: Turkey

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Carcinoma, Hepatocellular / Micro-Electrical-Mechanical Systems / Liver Neoplasms Limits: Humans Language: En Journal: Mikrochim Acta Year: 2024 Type: Article Affiliation country: Turkey