Your browser doesn't support javascript.
loading
Optic Nerve Sheath Diameter Point-of-Care Ultrasonography Quality Criteria Checklist: An International Consensus Statement on Optic Nerve Sheath Diameter Imaging and Measurement.
Hirzallah, Mohammad I; Lochner, Piergiorgio; Hafeez, Muhammad Ubaid; Lee, Andrew G; Krogias, Christos; Dongarwar, Deepa; Hartman, Nicholas D; Ertl, Michael; Robba, Chiara; Malojcic, Branko; Valaikiene, Jurgita; Sarwal, Aarti; Hakimi, Ryan; Schlachetzki, Felix.
Affiliation
  • Hirzallah MI; Department of Neurology, Section of Neurocritical Care and Vascular Neurology, Baylor College of Medicine, Houston, TX.
  • Lochner P; Center for Space Medicine, Baylor College of Medicine, Houston, TX.
  • Hafeez MU; Department of Neurology Saarland University, Homburg, Germany.
  • Lee AG; Department of Neurology, University of Texas Medical Branch at Galveston, Galveston, TX.
  • Krogias C; Department of Ophthalmology, Houston Methodist hospital, Houston, TX.
  • Dongarwar D; Department of Ophthalmology, Weill Cornell Medical College, New York, NY.
  • Hartman ND; Department of Neurology, Evangelisches Krankenhaus Herne, Academic Teaching Hospital of the Ruhr University Bochum, Herne, Germany.
  • Ertl M; UT Health McGovern School of Medicine, Houston, TX.
  • Robba C; Department of Emergency Medicine, Wake Forest School of Medicine, Winston-Salem, NC.
  • Malojcic B; Department of Neurology and Clinical Neurophysiology, University Hospital Augsburg, Augsburg, Germany.
  • Valaikiene J; Department of Anesthesia and Intensive Care, IRCCS Policlinico San Martino, Genova, Italy.
  • Sarwal A; Dipartimento di Scienze Chirurgiche Diagnostiche Integrate, University of Genoa, Italy.
  • Hakimi R; Department of Neurology, University Hospital Center Zagreb, Zagreb School of Medicine, Zagreb, Croatia.
  • Schlachetzki F; Clinic of Neurology and Neurosurgery, Institute of Clinical Medicine, Faculty of Medicine, Vilnius University, Vilnius, Lithuania.
Crit Care Med ; 2024 Jun 05.
Article in En | MEDLINE | ID: mdl-38836697
ABSTRACT

OBJECTIVES:

To standardize optic nerve sheath diameter (ONSD) point-of-care ultrasonography (POCUS) and improve its research and clinical utility by developing the ONSD POCUS Quality Criteria Checklist (ONSD POCUS QCC).

DESIGN:

Three rounds of modified Delphi consensus process and three rounds of asynchronous discussions.

SETTING:

Online surveys and anonymous asynchronous discussion.

SUBJECTS:

Expert panelists were identified according to their expertise in ONSD research, publication records, education, and clinical use. A total of 52 panelists participated in the Delphi process.

INTERVENTIONS:

None. MEASUREMENTS AND MAIN

RESULTS:

Three Delphi rounds and three asynchronous discussion rounds generated consensus on quality criteria (QC). This started with 29 QC in addition to other QC proposed by expert panelists. The QC items were categorized into probe selection, safety, body position, imaging, measurement, and research considerations. At the conclusion of the study, 28 QC reached consensus to include in the final ONSD POCUS QCC. These QC were then reorganized, edited, and consolidated into 23 QC that were reviewed and approved by the panelists.

CONCLUSIONS:

ONSD POCUS QCC standardizes ONSD ultrasound imaging and measurement based on international consensus. This can establish ONSD ultrasound in clinical research and improve its utility in clinical practice.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Crit Care Med Year: 2024 Type: Article