Comparison of a new composite index based on midlatency auditory evoked potentials and electroencephalographic parameters with bispectral index (BIS) during moderate propofol sedation.
Hadzidiakos, D; Petersen, S; Baars, J; Herold, K; Rehberg, B.
Afiliación
  • Hadzidiakos D; Charité, Universitaetsmedizin Berlin, Campus Virchow-Klinikum and Campus Charité Mitte, Department of Anaesthesiology and Intensive Care Medicine, Berlin, Germany. daniel.hadzidiakos@charite.de
Eur J Anaesthesiol ; 23(11): 931-6, 2006 Nov.
Article en En | MEDLINE | ID: mdl-16824245
ABSTRACT
BACKGROUND AND

OBJECTIVE:

Derived parameters of the electroencephalogram and auditory evoked potentials can be used to determine depth of anaesthesia and sedation. However, it is not known whether any parameter can identify the occurrence of awareness in individual patients. We have compared the performance of bispectral index and a new composite index derived from auditory evoked potentials and the electroencephalogram (AAI 1.61) in predicting consciousness, explicit and implicit memory during moderate sedation with propofol.

METHODS:

Twenty-one patients with spinal anaesthesia received intraoperatively propofol at the age-corrected C(50) for loss of consciousness and were presented test words via headphones. Bispectral index and AAI 1.61 (auditory evoked potentials, AEP-Monitor2) were recorded in parallel as well as the Observer's Assessment of Alertness/Sedation-score. Postoperatively, testing for explicit and implicit memory formation was performed.

RESULTS:

Bispectral index and AAI 1.61 correlated well with loss of consciousness defined by an Observer's Assessment of Alertness/Sedation-score of 2 (identical P(K) of 0.87), but did not allow a prediction of postoperative explicit or implicit recall.

CONCLUSIONS:

Both bispectral index and AAI may be indices of depth of sedation rather than indicators of memory formation, which persists during propofol sedation even after loss of consciousness.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Propofol / Sedación Consciente / Monitoreo Intraoperatorio / Anestésicos Intravenosos / Electroencefalografía / Potenciales Evocados Auditivos Tipo de estudio: Evaluation_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Anaesthesiol Asunto de la revista: ANESTESIOLOGIA Año: 2006 Tipo del documento: Article País de afiliación: Alemania
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Propofol / Sedación Consciente / Monitoreo Intraoperatorio / Anestésicos Intravenosos / Electroencefalografía / Potenciales Evocados Auditivos Tipo de estudio: Evaluation_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Anaesthesiol Asunto de la revista: ANESTESIOLOGIA Año: 2006 Tipo del documento: Article País de afiliación: Alemania