Your browser doesn't support javascript.
loading
Dose escalation in prostate radiotherapy up to 82 Gy using simultaneous integrated boost: direct comparison of acute and late toxicity with 3D-CRT 74 Gy and IMRT 78 Gy.
Dolezel, Martin; Odrazka, Karel; Vaculikova, Miloslava; Vanasek, Jaroslav; Sefrova, Jana; Paluska, Petr; Zouhar, Milan; Jansa, Jan; Macingova, Zuzana; Jarosova, Lida; Brodak, Milos; Moravek, Petr; Hartmann, Igor.
Afiliación
  • Dolezel M; Oncology Center, Multiscan & Pardubice Regional Hospital, Pardubice, Czech Republic. dolezelm@email.cz
Strahlenther Onkol ; 186(4): 197-202, 2010 Apr.
Article en En | MEDLINE | ID: mdl-20354663
ABSTRACT

PURPOSE:

To compare acute and late toxicity after three-dimensional conformal radiotherapy to the prostate to 74 Gy (3D-CRT) with intensity-modulated radiotherapy to 78 Gy (IMRT 78) and IMRT using simultaneous integrated boost to 82 Gy (IMRT/SIB 82). PATIENTS AND

METHODS:

94 patients treated with 3D-CRT to the prostate and base of seminal vesicles to 74 Gy represented the first group. The second group consisted of 138 patients subjected to IMRT covering the prostate and base of seminal vesicles to 78 Gy. The last group was treated with IMRT using SIB. The prescribed doses were 82 Gy and 73.8 Gy in 42 fractions to the prostate and seminal vesicles. Late toxicity was prospectively scored according to the RTOG/FC-LENT scale.

RESULTS:

Acute gastrointestinal toxicity >or= grade 2 occurred in 35.1% of patients treated with 3D-CRT, in 16% subjected to IMRT 78, and in 7.7% receiving IMRT/SIB 82. Acute genitourinary toxicity >or= grade 2 was observed in 26.6% (3D-CRT), 33% (IMRT 78), and 30.7% (IMRT/SIB 82). At 3 years, the estimated cumulative incidence of grade 3 late gastrointestinal toxicity was 14% for 3D-CRT, 5% for IMRT 78, and 2% for IMRT/SIB 82. The difference became significant (log rank p = 0.02). The estimated cumulative incidence of grade 3 late genitourinary toxicity was 9% (3D-CRT), 7% (IMRT 78), and 6% (IMRT/SIB 82) without statistical differences (log rank p = 0.32)

CONCLUSION:

SIB enables dose escalation up to 82 Gy with a lower rate of gastrointestinal toxicity grade 3 in comparison with 3D-CRT up to 74 Gy.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Traumatismos por Radiación / Fraccionamiento de la Dosis de Radiación / Radioterapia Conformacional / Radioterapia de Intensidad Modulada Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: Strahlenther Onkol Asunto de la revista: NEOPLASIAS / RADIOTERAPIA Año: 2010 Tipo del documento: Article País de afiliación: República Checa

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Traumatismos por Radiación / Fraccionamiento de la Dosis de Radiación / Radioterapia Conformacional / Radioterapia de Intensidad Modulada Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: Strahlenther Onkol Asunto de la revista: NEOPLASIAS / RADIOTERAPIA Año: 2010 Tipo del documento: Article País de afiliación: República Checa