Your browser doesn't support javascript.
loading
Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial.
Hermanides, J; Nørgaard, K; Bruttomesso, D; Mathieu, C; Frid, A; Dayan, C M; Diem, P; Fermon, C; Wentholt, I M E; Hoekstra, J B L; DeVries, J H.
Afiliación
  • Hermanides J; Department of Internal Medicine, Academic Medical Centre, Amsterdam, The Netherlands. j.hermanides@amc.uva.nl
Diabet Med ; 28(10): 1158-67, 2011 Oct.
Article en En | MEDLINE | ID: mdl-21294770
ABSTRACT

AIMS:

To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes.

METHODS:

In this investigator-initiated multi-centre trial (the Eurythmics Trial) in eight outpatient centres in Europe, we randomized 83 patients with Type 1 diabetes (40 women) currently treated with multiple daily injections, age 18-65 years and HbA(1c) ≥ 8.2% (≥ 66 mmol/mol) to 26 weeks of treatment with either a sensor-augmented insulin pump (n = 44) (Paradigm(®) REAL-Time) or continued with multiple daily injections (n = 39). Change in HbA(1c) between baseline and 26 weeks, sensor-derived endpoints and patient-reported outcomes were assessed.

RESULTS:

The trial was completed by 43/44 (98%) patients in the sensor-augmented insulin pump group and 35/39 (90%) patients in the multiple daily injections group. Mean HbA(1c) at baseline and at 26 weeks changed from 8.46% (SD 0.95) (69 mmol/mol) to 7.23% (SD 0.65) (56 mmol/mol) in the sensor-augmented insulin pump group and from 8.59% (SD 0.82) (70 mmol/mol) to 8.46% (SD 1.04) (69 mmol/mol) in the multiple daily injections group. Mean difference in change in HbA(1c) after 26 weeks was -1.21% (95% confidence interval -1.52 to -0.90, P < 0.001) in favour of the sensor-augmented insulin pump group. This was achieved without an increase in percentage of time spent in hypoglycaemia between-group difference 0.0% (95% confidence interval -1.6 to 1.7, P = 0.96). There were four episodes of severe hypoglycaemia in the sensor-augmented insulin pump group and one episode in the multiple daily injections group (P = 0.21). Problem Areas in Diabetes and Diabetes Treatment Satisfaction Questionnaire scores improved in the sensor-augmented insulin pump group.

CONCLUSIONS:

Sensor augmented pump therapy effectively lowers HbA(1c) in patients with Type 1 diabetes suboptimally controlled with multiple daily injections.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Glucemia / Hemoglobina Glucada / Sistemas de Infusión de Insulina / Bombas de Infusión Implantables / Diabetes Mellitus Tipo 1 / Hipoglucemiantes / Insulina Tipo de estudio: Clinical_trials Límite: Adult / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Diabet Med Asunto de la revista: ENDOCRINOLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Glucemia / Hemoglobina Glucada / Sistemas de Infusión de Insulina / Bombas de Infusión Implantables / Diabetes Mellitus Tipo 1 / Hipoglucemiantes / Insulina Tipo de estudio: Clinical_trials Límite: Adult / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Diabet Med Asunto de la revista: ENDOCRINOLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Países Bajos