The Italian Register of Biological Prostheses.
Eur Surg Res
; 50(3-4): 262-72, 2013.
Article
en En
| MEDLINE
| ID: mdl-23751813
BACKGROUND: A wide variety of meshes are available for surgical treatment of abdominal wall defects. These meshes are constructed with different materials with different biological properties. METHODS: A prospective database was instituted (January 2009-December 2010) to register biological prostheses (BPs) implanted in Italy. RESULTS: A total of 193 cases were registered. The mean age of the patients was 53.1 years (SD ±7.4). The ratio of males to females was 1.3 to 1. The mean body mass index was 28.2 (SD ±4.1). The breakdown of American Society of Anesthesiologists (ASA) scores was as follows: ASA I, 35.7%; ASA II, 27.5%; ASA III, 31.6%, and ASA IV, 5.2%. For ventral-incisional hernias, the mean duration of surgery was 101.1 min (SD ±25.3), while for inguinal-femoral hernias it was 49.2 min (SD ±19.1). The rate of urgent procedures was 36.7%. The surgical field was clean in 57.4% of cases, clean-contaminated in 21.3%, contaminated in 12.3% and dirty in 9%. Techniques used for inguinal-femoral hernias were as follows: Lichtenstein in 66.7%, plug and mesh in 3.8%, transabdominal-preperitoneal in 25.7% and intraperitoneal onlay mesh in 3.8%. The following prostheses were used: swine intestinal submucosa in 54.9%, porcine dermal collagen in 39.9% and bovine pericardium in 5.2%. In 45.1% of cases the prostheses were cross-linked. Techniques used for ventral-incisional hernias were as follows: onlay in 3.6%, inlay in 5.5%, sublay in 62.7% and underlay via laparoscopy in 28.2%. The mean overlap was 4.1 cm (SD ±1.2). No intestinal anastomosis was necessary in 65.3% of cases; however, small/large bowel resection and anastomoses were necessary in 22.3 and 12.4% of cases, respectively. Intraoperative blood transfusion was necessary in 10.4% of procedures. The skin was completely closed in 84% of procedures. At the 1-month follow-up, there were no complications in 54.4% of cases. Among the cases with complications, 10 patients (5.8%) experienced recurrence, and the postoperative readmission rate was 12.9%. The average visual analog scale (VAS) score for pain was 2.9 (SD ±1.2) at rest. At the 1-year follow-up, there were no complications in 96.4% of cases. Two patients experienced recurrence, and the postoperative readmission rate was 3.6%. The average VAS score for pain was 1.8 (SD ±0.8) at rest. CONCLUSIONS: This register shows that BPs are highly versatile and can be used in either open or laparoscopic surgery in all kinds of patients and in contaminated surgical fields. However, due to the very good outcomes of synthetic meshes and the high costs of BPs, the latter should only be used in selected cases.
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Bioprótesis
/
Sistema de Registros
/
Herniorrafia
Tipo de estudio:
Observational_studies
Límite:
Animals
/
Female
/
Humans
/
Male
/
Middle aged
País/Región como asunto:
Europa
Idioma:
En
Revista:
Eur Surg Res
Año:
2013
Tipo del documento:
Article
País de afiliación:
Italia