Your browser doesn't support javascript.
loading
Maximal, minimal, and mean pulsed Doppler parameters: which should be utilized in the diagnosis of thyroid nodules?
Zhou, J Q; Zhou, C; Zhan, W W; Zhou, W; Dong, Y J.
Afiliación
  • Zhou JQ; Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200025, China.
  • Zhou C; Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200025, China.
  • Zhan WW; Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200025, China. Electronic address: shanghairuijin@126.com.
  • Zhou W; Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200025, China.
  • Dong YJ; Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200025, China.
Clin Radiol ; 69(12): e477-84, 2014 Dec.
Article en En | MEDLINE | ID: mdl-25246337
ABSTRACT

AIM:

To compare the diagnostic efficacy of the maximal, minimal, and mean pulsatility index (PI) and resistance index (RI) and determine which should be utilized in the evaluation of thyroid nodules. MATERIALS AND

METHODS:

A total of 224 consecutive patients with thyroid nodules were included in this prospective study. Doppler signals from three different nodular arteries were obtained and six Doppler parameters were used for final

analysis:

maximal PI (PImax), minimal PI (PImin), mean PI (PImean), maximal RI (RImax), minimal RI (RImin), and mean RI (RImean).

RESULTS:

Eighty-five patients had malignant and 139 cases had benign thyroid nodules. All three sets of PI and RI parameters were significantly higher in malignant than in benign thyroid nodules (p = 0.000 for all). The area under the receiver operating characteristic (ROC) curve (Az) of PImax was significantly higher than that of PImin (p = 0.046) and higher than that of PImean (p = 0.161). The Az value of RImax was higher than that of RImean and RImin; however, the differences were not significant (p = 0.403, and p = 0.058, respectively). The Az values of the three sets of PI parameters (PImax, PImin, and PImean) were significantly higher than those of the corresponding sets of RI parameters (p = 0.005, p = 0.003, and p = 0.003, respectively).

CONCLUSION:

Maximal pulsed Doppler parameters should be utilized in the evaluation of thyroid nodules. PI parameters were superior to the RI parameters in determining malignant nodules.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Nódulo Tiroideo / Ultrasonografía Doppler de Pulso Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Radiol Año: 2014 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Nódulo Tiroideo / Ultrasonografía Doppler de Pulso Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Radiol Año: 2014 Tipo del documento: Article País de afiliación: China