Transcatheter closure of atrial septal defect protects from pulmonary edema: septal occluder device gradually reduces LR shunt.
Heart Vessels
; 32(1): 101-104, 2017 Jan.
Article
en En
| MEDLINE
| ID: mdl-27314266
A 56-year-old woman was diagnosed as atrial septal defect (ASD) with pulmonary hypertension; pulmonary blood flow/systemic blood flow (Qp/Qs) of 2.3, pulmonary artery pressure (PAP) of 71/23(39) mmHg and diastolic dysfunction of left ventricle. PAP was improved after medical therapy; therefore, transcatheter ASD closure was performed. Seven days later, left-sided heart failure occurred, however, the improvement of Qp/Qs (1.7) and PAP of 51/21(32) was confirmed. Diuretic therapy was introduced which led to further decrease of PAP 40/12(25) and Qp/Qs (1.1). Because of gradual decrease of Qp/Qs, this patient appeared to be protected from acute pulmonary edema.