Your browser doesn't support javascript.
loading
Magnetic resonance imaging findings of age-related distance esotropia in Japanese patients with high myopia.
Kono, Reika; Ohtsuki, Hiroshi; Kishimoto, Fumiko; Hamasaki, Ichiro; Morizane, Yuki; Shiraga, Fumio.
Afiliación
  • Kono R; Department of Ophthalmology, Medical School, Okayama University, 2-5-1 Shikata-cho, Kita-ku, Okayama City, Okayama, 700-8558, Japan. rkono@okayama-u.ac.jp.
  • Ohtsuki H; Division of Ophthalmology, Okayama Saiseikai General Hospital, Okayama, Japan.
  • Kishimoto F; Division of Ophthalmology, Ibara City Hospital, Ibara, Japan.
  • Hamasaki I; Department of Ophthalmology, Okayama University Hospital, Okayama, Japan.
  • Morizane Y; Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan.
  • Shiraga F; Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan.
Graefes Arch Clin Exp Ophthalmol ; 257(3): 657-662, 2019 Mar.
Article en En | MEDLINE | ID: mdl-30671656
ABSTRACT

PURPOSE:

This study aimed to investigate the characteristics of the extraocular muscles and the orbital connective tissue pulleys in Japanese patients with age-related distance esotropia (ARDE) and high myopia using magnetic resonance imaging (MRI).

METHODS:

This was a retrospective case-series study. High-resolution coronal MRI scans of 12 orbits were obtained in 6 patients with ARDE and high myopia (age range 51-69 years). We analyzed the images to determine the positions of the rectus muscle pulleys relative to the center of the globe, the integrity of the lateral rectus-superior rectus muscle (LR-SR) band, and the LR angle (the angle between the major axis of the LR and the vertical plane).

RESULTS:

The distance esotropia ranged from 4 to 25∆, and 3 cases exhibited vertical deviations. The mean (±standard deviation (SD)) axial length was 28.5 (± 1.6) mm. The mean positions of the medial rectus muscle pulley and LR pulley were 1.3 mm inferior and 1.4 mm inferior, respectively, to those seen in the normal control group in our previous study (P = 0.002 and P = 0.05, respectively). All 12 orbits had abnormal elongated LR-SR bands, and 8 orbits (67%) displayed ruptured LR-SR bands. The LR angle (mean±SD; 18.8° ± 8.5°) increased significantly with the inferior displacement of the LR pulley (R2 = 0.77, P = 0.0002).

CONCLUSIONS:

Inferior displacement of the LR pulley and abnormal LR-SR bands were seen in Japanese ARDE patients with high myopia, as was found in ARDE patients without high myopia. The LR angle might be useful for judging the degree of LR pulley displacement.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Órbita / Refracción Ocular / Imagen por Resonancia Magnética / Esotropía / Movimientos Oculares / Miopía / Músculos Oculomotores Tipo de estudio: Diagnostic_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Año: 2019 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Órbita / Refracción Ocular / Imagen por Resonancia Magnética / Esotropía / Movimientos Oculares / Miopía / Músculos Oculomotores Tipo de estudio: Diagnostic_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Año: 2019 Tipo del documento: Article País de afiliación: Japón