Your browser doesn't support javascript.
loading
Superior performance of 18F-fluorocholine digital PET/CT in the detection of parathyroid adenomas.
López-Mora, Diego Alfonso; Sizova, Marina; Estorch, Montserrat; Flotats, Albert; Camacho, Valle; Fernández, Alejandro; Abouzian, Safae; Fuentes-Ocampo, Francisco; Garcia, José Ignacio Pérez; Ballesteros, Ana Isabel Chico; Duch, Joan; Domènech, Anna; Duarte, Antonio Moral; Carrió, Ignasi.
Afiliación
  • López-Mora DA; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain. dlopezmo@santpau.cat.
  • Sizova M; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain.
  • Estorch M; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain.
  • Flotats A; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain.
  • Camacho V; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain.
  • Fernández A; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain.
  • Abouzian S; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain.
  • Fuentes-Ocampo F; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain.
  • Garcia JIP; General Surgery Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Ballesteros AIC; Endocrinology Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Duch J; Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Madrid, Spain.
  • Domènech A; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain.
  • Duarte AM; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Pare Claret 167, 08025, Barcelona, Spain.
  • Carrió I; General Surgery Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain.
Eur J Nucl Med Mol Imaging ; 47(3): 572-578, 2020 03.
Article en En | MEDLINE | ID: mdl-31919634
OBJECTIVE: To compare detectability of hyperfunctioning parathyroid tissue (HPT) by digital and analog 18F-fluorocholine PET/CT in patients with primary hyperparathyroidism and negative/inconclusive 99mTc-MIBI scintigraphy-SPECT/CT. MATERIALS AND METHODS: Thirty-three patients with primary hyperparathyroidism and negative/inconclusive 99mTc-MIBI scintigraphy-SPECT/CT were prospectively included. All patients accepted to be scanned by digital and analog PET/CT in the same imaging session after a single injection of 18F-fluorocholine. Three nuclear medicine physicians evaluated the digital and analog PET/CT datasets to assess the detection rate of HPT. Maximum standard uptake values (SUVmax) of HPT and locoregional lymph nodes were measured in both systems. RESULTS: HPT was detected in 30/33 patients by the digital system, whereas it was detected in 22/33 patients by the analog system (p < 0.01). Moreover, in 21 of these 33 patients, both systems detected one focal 18F-fluorocholine uptake, and in one patient the digital system detected two foci. Histopathology demonstrated HPT in 32 patients and it was inconclusive in one patient. The digital PET/CT detected HPT in 29 of the 32 patients, and the analog system in 22 of the 32 (p < 0.01). All HPT suspected lesions resected and detected only by the digital system (n = 8) were < 10 mm (7.5 ± 1.3 mm), while those detected by both systems (n = 22) were > 10 mm (13 ± 3.8 mm). SUVmax of HPT lesions was significantly higher than SUVmax of locoregional lymph node independently of the PET/CT system used (4.5 ± 1.9 vs. 2.9 ± 1.3, p < 0.0001). CONCLUSIONS: Digital PET/CT offers superior performance over analog system in patients with suspected HPT and previous negative/inconclusive imaging examinations, particularly in sub-centimeter lesions. SUVmax can help in the differentiation between HTP and locoregional lymph nodes.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de las Paratiroides / Hiperparatiroidismo Primario Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Eur J Nucl Med Mol Imaging Asunto de la revista: MEDICINA NUCLEAR Año: 2020 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de las Paratiroides / Hiperparatiroidismo Primario Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Eur J Nucl Med Mol Imaging Asunto de la revista: MEDICINA NUCLEAR Año: 2020 Tipo del documento: Article País de afiliación: España