Your browser doesn't support javascript.
loading
Ultrasensitive Detection of the Hepatitis E Virus by Electrocatalytic Water Oxidation Using Pt-Co3O4 Hollow Cages.
Ganganboina, Akhilesh Babu; Khoris, Indra Memdi; Chowdhury, Ankan Dutta; Li, Tian-Cheng; Park, Enoch Y.
Afiliación
  • Ganganboina AB; Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka 422-8529, Japan.
  • Khoris IM; Department of Bioscience, Graduate School of Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka 422-8529, Japan.
  • Chowdhury AD; Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka 422-8529, Japan.
  • Li TC; Department of Virology 2, National Institute of Infectious Diseases, 4-7-1 Gakuen, Musashimurayam-shi, Tokyo 208-0011, Japan.
  • Park EY; Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka 422-8529, Japan.
ACS Appl Mater Interfaces ; 12(45): 50212-50221, 2020 Nov 11.
Article en En | MEDLINE | ID: mdl-32967416
ABSTRACT
A sensitive virus detection method applicable for an early stage increases the probability of survival. Here, we develop a simple and rapid detection strategy for the detection of the hepatitis E virus (HEV) by an electrocatalytic water oxidation reaction (WOR) using a platinum (Pt)-incorporated cobalt (Co)-based zeolite imidazole framework (ZIF-67). The surface cavity of ZIF-67 enables the rich loading of Pt NPs, and subsequent calcination etches the cavity, promoting the electrocatalytic activity of Pt-Co3O4 HCs. The Pt-Co3O4 HCs show excellent behavior for the WOR due to the synergistic interaction of Pt and Co3O4, evaluated by voltammetry and chronoamperometry. The synthesized Pt-Co3O4 HCs are conjugated with anti-HEV antibody (Ab@Pt-Co3O4 HCs); the electrocatalytic activity of Ab@Pt-Co3O4 HCs is combined with that of antibody-conjugated magnetic nanoparticles (MNPs) for HEV detection by a magneto-and-nanocomposite sandwich immunoassay. The sensor is challenged to detect the HEV in spiked serum samples and HEV G7 genotypes collected from the cell culture supernatant, reaching a low limit of detection down to 61 RNA copies mL-1. This work establishes a free-indicator one-step approach with the controlled design of Pt-Co3O4 HCs, which presents an effective WOR technique for virus detection in a neutral pH solution, which can be extended to electrocatalytic studies in the future integrated biosensing systems.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Óxidos / Platino (Metal) / Agua / Técnicas Biosensibles / Virus de la Hepatitis E / Cobalto / Técnicas Electroquímicas Tipo de estudio: Diagnostic_studies Idioma: En Revista: ACS Appl Mater Interfaces Asunto de la revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Año: 2020 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Óxidos / Platino (Metal) / Agua / Técnicas Biosensibles / Virus de la Hepatitis E / Cobalto / Técnicas Electroquímicas Tipo de estudio: Diagnostic_studies Idioma: En Revista: ACS Appl Mater Interfaces Asunto de la revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Año: 2020 Tipo del documento: Article País de afiliación: Japón