Your browser doesn't support javascript.
loading
Shape analysis of rectus extraocular muscles with age and axial length using anterior segment optical coherence tomography.
Shibata, Kiyo; Fujiwara, Atsushi; Hamasaki, Ichiro; Shimizu, Takehiro; Kono, Reika; Kanenaga, Keisuke; Nakazawa, Masanori; Morizane, Yuki.
Afiliación
  • Shibata K; Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama City, Okayama, Japan.
  • Fujiwara A; Department of Orthoptics, Faculty of Rehabilitation, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan.
  • Hamasaki I; Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama City, Okayama, Japan.
  • Shimizu T; Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama City, Okayama, Japan.
  • Kono R; Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama City, Okayama, Japan.
  • Kanenaga K; Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama City, Okayama, Japan.
  • Nakazawa M; Department of Ophthalmology, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan.
  • Morizane Y; Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama City, Okayama, Japan.
PLoS One ; 15(12): e0243382, 2020.
Article en En | MEDLINE | ID: mdl-33362229
ABSTRACT

PURPOSE:

This study aimed to evaluate the shape of the extraocular muscles (EOMs) in normal subjects using the en-face images of anterior segment optical coherence tomography (AS-OCT). The EOM insertion and the direction of the muscle fibers were investigated. SUBJECTS AND

METHODS:

A total of 97 healthy normal subjects (194 eyes) at Okayama University Hospital (age, 47.1±21.5 years; range, 8-79 years) participated in the study. A series of 256 tomographic images of the rectus EOMs were captured using the C-scan function of the AS-OCT (CASIA2, TOMEY Co., Japan), and the images were converted to en-face images in multi-TIFF format. The anterior chamber angle to EOM insertion distance (AID) and the angle of the muscle fibers from the insertion site (angle of muscles) were measured from the images. The correlations of AID and angle of muscles with age and axial length were investigated and evaluated.

RESULTS:

AID and angle of muscles were significantly correlated with age or axial length in some EOMs. The AIDs of medial rectus (MR) (P = 0.000) and superior rectus (SR) (P = 0.005) shortened with age. The AIDs of MR (P = 0.001) and inferior rectus (IR) (P = 0.035) elongated with axial length, whereas lateral rectus (LR) (P = 0.013) shortened. The angles of MR (P = 0.001) and LR (P = 0.000) were found to have a more downward direction toward the posterior in older subjects.

CONCLUSION:

En-face images can be created by AS-OCT, and the shape of the EOMs in normal subjects using these image measurements was available. With the ability to assess the EOMs, AID and angle of muscles are expected give useful information for treating and diagnosing strabismus-related diseases.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Envejecimiento / Tomografía de Coherencia Óptica / Segmento Anterior del Ojo / Músculos Oculomotores Límite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2020 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Envejecimiento / Tomografía de Coherencia Óptica / Segmento Anterior del Ojo / Músculos Oculomotores Límite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2020 Tipo del documento: Article País de afiliación: Japón