Your browser doesn't support javascript.
loading
Sludge dewaterability enhancement under low temperature condition with cold-tolerant Bdellovibrio sp. CLL13.
Yan, Chunhui; Zhan, Manjun; Xv, Kewei; Zhang, Siyuan; Liang, Ting; Yu, Ran.
Afiliación
  • Yan C; Department of Environmental Science and Engineering, School of Energy and Environment, Southeast University, Nanjing 210096, China.
  • Zhan M; Nanjing Research Institute of Environmental Protection, Nanjing Environmental Protection Bureau, Nanjing 210013, Jiangsu, China.
  • Xv K; Wuxi Xishan Water Group Co., Ltd., Wuxi 214101, Jiangsu, China.
  • Zhang S; Department of Environmental Science and Engineering, School of Energy and Environment, Southeast University, Nanjing 210096, China.
  • Liang T; Wuxi Xishan Water Group Co., Ltd., Wuxi 214101, Jiangsu, China.
  • Yu R; Department of Environmental Science and Engineering, School of Energy and Environment, Southeast University, Nanjing 210096, China. Electronic address: yuran@seu.edu.cn.
Sci Total Environ ; 820: 153269, 2022 May 10.
Article en En | MEDLINE | ID: mdl-35074377
ABSTRACT
The dewatering performance of waste activated sludge (WAS) is generally deteriorated under low temperature due to the increase of viscosity, which would exacerbate the difficulties in sludge treatment and disposal. In this study, the cold-tolerant Bdellovibrio sp. CLL13 was successfully screened for efficient sludge biolysis, and it dramatically improved the sludge dewaterability while no significant biolysis effects were observed for the mesophilic BALO strain at 12 °C. The reduction rates of the sludge capillary suction time (CST), the specific resistance of filtration (SRF), the sludge dry weight, and the fecal coliform bacteria concentration at the optimal reaction time of 14 h were 40.1 ± 0.2%, 69.6 ± 0.7%, 7.7 ± 0.4%, and 78.5 ± 0.4%, respectively, when the mixed liquid suspended solids (MLSS) content was between 10.8 and 29.6 g/L, the input dosage of CLL13 was 8.8 × 106 PFU/mL sludge, and the DO level was 1.2 mg/L. Meanwhile, the viscosity reduction rate, the relative hydrophobicity increasement rate, and the bound water reduction rate were 20.3 ± 1.2%, 6.9 ± 0.7%, and 29.4 ± 1.0%, respectively. The ratios of protein content to polysaccharides content in the extracellular polymeric substances (EPS) decreased significantly. In addition, the degradation of the macromolecular substances in EPS and the increase of the soluble chemical oxygen demand, the total nitrogen, the total phosphorus, and the lactate dehydrogenase levels were observed. Therefore, the cold-tolerant CLL13 induced the sludge biolysis and compromised the negative effects of low temperature on the sludge dewatering performance, which should be beneficial for the efficient WAS biolysis treatment application in the near future under low temperature.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aguas del Alcantarillado / Bdellovibrio Idioma: En Revista: Sci Total Environ Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aguas del Alcantarillado / Bdellovibrio Idioma: En Revista: Sci Total Environ Año: 2022 Tipo del documento: Article País de afiliación: China