Your browser doesn't support javascript.
loading
Examining the Quasi-Static Uniaxial Compressive Behaviour of Commercial High-Performance Epoxy Matrices.
Gargiuli, J F; Quino, G; Board, R; Griffith, J C; Shaffer, M S P; Trask, R S; Hamerton, I.
Afiliación
  • Gargiuli JF; Bristol Composites Institute, School of Civil, Aerospace, and Design Engineering, Faculty of Science and Engineering, University of Bristol, Queen's Building, University Walk, Bristol BS8 1TR, UK.
  • Quino G; Bristol Composites Institute, School of Civil, Aerospace, and Design Engineering, Faculty of Science and Engineering, University of Bristol, Queen's Building, University Walk, Bristol BS8 1TR, UK.
  • Board R; Department of Aeronautics, Imperial College London, South Kensington Campus, London SW7 2AZ, UK.
  • Griffith JC; Bristol Composites Institute, School of Civil, Aerospace, and Design Engineering, Faculty of Science and Engineering, University of Bristol, Queen's Building, University Walk, Bristol BS8 1TR, UK.
  • Shaffer MSP; Bristol Composites Institute, School of Civil, Aerospace, and Design Engineering, Faculty of Science and Engineering, University of Bristol, Queen's Building, University Walk, Bristol BS8 1TR, UK.
  • Trask RS; Department of Materials and Department of Chemistry, Imperial College London, South Kensington Campus, London SW7 2AZ, UK.
  • Hamerton I; Bristol Composites Institute, School of Civil, Aerospace, and Design Engineering, Faculty of Science and Engineering, University of Bristol, Queen's Building, University Walk, Bristol BS8 1TR, UK.
Polymers (Basel) ; 15(19)2023 Oct 08.
Article en En | MEDLINE | ID: mdl-37836071
Four commercial high-performance aerospace aromatic epoxy matrices, CYCOM®890, CYCOM®977-2, PR520, and PRISM EP2400, were cured to a standardised 2 h, 180 °C cure cycle and evaluated in quasi-static uniaxial compression, as well as by dynamic scanning calorimetry (DSC) and thermogravimetric analysis (TGA). The thermoplastic toughened CYCOM®977-2 formulation displayed an overall increase in true axial stress values across the entire stress-strain curve relative to the baseline CYCOM®890 sample. The particle-toughened PR520 sample exhibited an overall decrease in true axial stress values past the yield point of the material. The PRISM EP2400 resin, with combined toughening agents, led to true axial stress values across the entire plastic region of the stress-strain curve, which were in line with the stress values observed with the CYCOM®890 material. Interestingly, for all formulations, the dilation angles (associated with the volume change during plastic deformation), recorded at 0.3 plastic strain, were close to 0°, with the variations reflecting the polymer structure. Compression data collected for this series of commercial epoxy resins are in broad agreement with a selection of model epoxy resins based on di- and tetra-functional monomers, cured with polyamines or dicarboxylic anhydrides. However, the fully formulated resins demonstrate a significantly higher compressive modulus than the model resins, albeit at the expense of yield stress.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Polymers (Basel) Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Polymers (Basel) Año: 2023 Tipo del documento: Article