Comparison of a new immobilization method using a reusable 3-point fixation cylinder system and bite-block type immobilization methods in veterinary radiotherapy.
Yoda, Shinichiro; Maruo, Takuya; Arai, Haruka; Takahashi, Rihoko; Kusaka, Takuya; Nishiyama, Yuta; Kayanuma, Hideki.
Afiliación
  • Yoda S; Laboratory of Veterinary Radiology, School of Veterinary Medicine, Azabu University, Sagamihara, Kanagawa, Japan.
  • Maruo T; Laboratory of Veterinary Radiology, School of Veterinary Medicine, Azabu University, Sagamihara, Kanagawa, Japan.
  • Arai H; Veterinary Teaching Hospital, Azabu University, Sagamihara, Kanagawa, Japan.
  • Takahashi R; Laboratory of Veterinary Radiology, School of Veterinary Medicine, Azabu University, Sagamihara, Kanagawa, Japan.
  • Kusaka T; Laboratory of Veterinary Radiology, School of Veterinary Medicine, Azabu University, Sagamihara, Kanagawa, Japan.
  • Nishiyama Y; Veterinary Teaching Hospital, Azabu University, Sagamihara, Kanagawa, Japan.
  • Kayanuma H; Veterinary Teaching Hospital, Azabu University, Sagamihara, Kanagawa, Japan.
Vet Radiol Ultrasound ; 65(4): 323-333, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38554033
ABSTRACT
In veterinary radiotherapy, highly reproducible immobilization is important for accurate irradiation. Consequently, we developed a new reusable head-immobilization method for dogs using cylinders. This study aimed to compare the accuracy of our novel immobilization method using cylinders with that of bite-block type immobilization methods. Three immobilization methods were compared bite-block only, bite-block combined with torso immobilization, and immobilization using cylinders. Five beagles with canine teeth underwent CT five times for each of the three immobilization methods. One beagle without canine teeth underwent CT 15 times using each method. Three maxillary landmarks (maxillary incisor, frontal sinus, and occipital bone) and one mandibular landmark (mandibular incisor) were established, and the errors in each immobilization method were measured. For all head landmarks, the error in the immobilization method using cylinders was the most reproducible, with the smallest errors. No significant differences were observed in the time required for immobilization. Although there were limitations (such as the use of dogs from a single breed, a single episode of anesthesia, no disassembly of the immobilization system between scans, and the same person performing the positioning on the same day), we found our new reusable immobilization method using cylinders was the most accurate among the three compared methods. This was a proof-of-principle study to evaluate head immobilization using cylinders, and further investigations are needed to confirm its clinical utility.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Inmovilización Límite: Animals Idioma: En Revista: Vet Radiol Ultrasound Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA VETERINARIA / RADIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Inmovilización Límite: Animals Idioma: En Revista: Vet Radiol Ultrasound Asunto de la revista: DIAGNOSTICO POR IMAGEM / MEDICINA VETERINARIA / RADIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Japón