On-X aortic valve replacement patients treated with low-dose warfarin and low-dose aspirin.
Eur J Cardiothorac Surg
; 65(5)2024 May 03.
Article
en En
| MEDLINE
| ID: mdl-38621698
ABSTRACT
OBJECTIVES:
To assess if warfarin targeted to international normalized ratio (INR) 1.8 (range 1.5-2.0) is safe for all patients with an On-X aortic mechanical valve.METHODS:
This prospective, observational registry follows patients receiving warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus daily aspirin (75-100 mg) after On-X aortic valve replacement. The primary end point is a composite of thromboembolism, valve thrombosis and major bleeding. Secondary end points include the individual rates of thromboembolism, valve thrombosis and major bleeding, as well as the composite in subgroups of home or clinic-monitored INR and risk categorization for thromboembolism. The control was the patient group randomized to standard-dose warfarin (INR 2.0-3.0) plus daily aspirin 81 mg from the PROACT trial.RESULTS:
A total of 510 patients were enroled at 23 centres in the UK, USA and Canada. Currently, the median follow-up duration is 3.4 years, and median achieved INR is 1.9. The primary composite end point rate in the low INR patients is 2.31% vs 5.39% (95% confidence interval 4.12-6.93%) per patient-year in the PROACT control group, constituting a 57% reduction. Results are consistent in subgroups of home or clinic-monitored, and high-risk patients, with reductions of 56%, 57% and 57%, respectively. Major and total bleeding are decreased by 85% and 73%, respectively, with similar rates of thromboembolic events. No valve thrombosis occurred.CONCLUSIONS:
Interim results suggest that warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus aspirin is safe and effective in patients with an On-X aortic mechanical valve with or without home INR monitoring.Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Válvula Aórtica
/
Tromboembolia
/
Warfarina
/
Aspirina
/
Relación Normalizada Internacional
/
Implantación de Prótesis de Válvulas Cardíacas
/
Anticoagulantes
Límite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Eur J Cardiothorac Surg
Asunto de la revista:
CARDIOLOGIA
Año:
2024
Tipo del documento:
Article