Your browser doesn't support javascript.
loading
The deep abdominal ultrasound transducer (DAX) increases the success rate and diagnostic accuracy of shear wave elastography for liver fibrosis assessment in patients with obesity-A prospective biopsy-controlled study.
Bauer, David J M; Nixdorf, Larissa; Dominik, Nina; Schwarz, Michael; Hofer, Benedikt S; Hartl, Lukas; Semmler, Georg; Jachs, Mathias; Simbrunner, Benedikt; Jedamzik, Julia; Mozayani, Behrang; Gensthaler, Lisa; Felsenreich, Daniel Moritz; Trauner, Michael; Langer, Felix Benedikt; Mandorfer, Mattias; Prager, Gerhard; Reiberger, Thomas.
Afiliación
  • Bauer DJM; Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Nixdorf L; Vienna HIV & Liver Study Group, Medical University of Vienna, Vienna, Austria.
  • Dominik N; Department of Internal Medicine IV, Klinik Ottakring, Vienna, Austria.
  • Schwarz M; Division of General Surgery and Metabolic- and Bariatric Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria.
  • Hofer BS; Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Hartl L; Vienna HIV & Liver Study Group, Medical University of Vienna, Vienna, Austria.
  • Semmler G; Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Jachs M; Vienna HIV & Liver Study Group, Medical University of Vienna, Vienna, Austria.
  • Simbrunner B; Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Jedamzik J; Vienna HIV & Liver Study Group, Medical University of Vienna, Vienna, Austria.
  • Mozayani B; Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Gensthaler L; Vienna HIV & Liver Study Group, Medical University of Vienna, Vienna, Austria.
  • Felsenreich DM; Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Trauner M; Vienna HIV & Liver Study Group, Medical University of Vienna, Vienna, Austria.
  • Langer FB; Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Mandorfer M; Vienna HIV & Liver Study Group, Medical University of Vienna, Vienna, Austria.
  • Prager G; Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria.
  • Reiberger T; Vienna HIV & Liver Study Group, Medical University of Vienna, Vienna, Austria.
Aliment Pharmacol Ther ; 60(1): 70-82, 2024 07.
Article en En | MEDLINE | ID: mdl-38693718
ABSTRACT

BACKGROUND:

Obesity impacts the diagnostic accuracy of shear wave elastography (SWE). A deep abdominal ultrasound transducer (DAX) capable of point (pSWE) and two-dimensional (2D)-SWE has recently been introduced to address this issue.

METHODS:

We performed a prospective study in a cohort of mostly patients with obesity undergoing liver biopsy with a high prevalence of metabolic dysfunction-associate steatotic liver disease (MASLD). Liver stiffness measurement (LSM) was measured using vibration-controlled transient elastography (VCTE), as well as pSWE and 2D SWE on the standard (5C1) and the DAX transducers.

RESULTS:

We included 129 patients with paired LSM and liver biopsy median age 44.0 years, 82 (63.6%) women, median BMI 43.2 kg/m2. Histologic fibrosis stages F0 N = 55 (42.6%), F1 N = 14 (10.9%), F2 N = 50 (38.8%), F3 N = 2 (1.6%), F4 N = 8 (6.2%). VCTE-LSM failed (N = 13) or were unreliable (IQR/median ≤30% in ≥7.1 kPa, N = 14) in 20.9% of patients. The Pearson correlation of reliable VCTE-LSM with both pSWE and 2D SWE was strong (all >0.78). The diagnostic accuracy for all LSM techniques was poor for significant fibrosis (≥F2, AUC 0.54-0.63); however, it was good to excellent for advanced fibrosis (≥F3, AUC 0.87-0.99) and cirrhosis (F4, AUC 0.86-1.00). In intention-to-diagnose analysis, pSWE on DAX was significantly superior to VCTE-LSM.

CONCLUSIONS:

pSWE- and 2D-SWE enable the non-invasive identification of advanced fibrosis and cirrhosis in patients with obese MASLD. The use of the DAX transducer for acoustic radiation force imaging (ARFI)-LSM avoids technical failures in an obese population and subsequently offers advantages over VCTE-LSM for the evaluation of fibrosis in an obese MASLD population at risk for fibrosis.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diagnóstico por Imagen de Elasticidad / Cirrosis Hepática / Obesidad Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Aliment Pharmacol Ther Asunto de la revista: FARMACOLOGIA / GASTROENTEROLOGIA / TERAPIA POR MEDICAMENTOS Año: 2024 Tipo del documento: Article País de afiliación: Austria

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diagnóstico por Imagen de Elasticidad / Cirrosis Hepática / Obesidad Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Aliment Pharmacol Ther Asunto de la revista: FARMACOLOGIA / GASTROENTEROLOGIA / TERAPIA POR MEDICAMENTOS Año: 2024 Tipo del documento: Article País de afiliación: Austria