Your browser doesn't support javascript.
loading
Technical Aspects and Outcome of Multi-Staged and Single-Staged Thoracoabdominal Fenestrated Endovascular Aortic Repair.
Frese, Jan Paul; Walter, Corinna; Carstens, Jan; Bürger, Matthias; Greiner, Andreas; Assadian, Afshin; Kapahnke, Sebastian; Falkensammer, Jürgen.
Afiliación
  • Frese JP; Department of Vascular Surgery, Charité-Universitätsmedizin Berlin, Berlin, Germany.
  • Walter C; Department of Vascular and Endovascular Surgery, Klinik Ottakring, Vienna, Austria.
  • Carstens J; Department of Vascular Surgery, Charité-Universitätsmedizin Berlin, Berlin, Germany.
  • Bürger M; Department of Vascular Surgery, Charité-Universitätsmedizin Berlin, Berlin, Germany.
  • Greiner A; Department of Vascular Surgery, Charité-Universitätsmedizin Berlin, Berlin, Germany.
  • Assadian A; Department of Vascular and Endovascular Surgery, Klinik Ottakring, Vienna, Austria.
  • Kapahnke S; Department of Vascular Surgery, Charité-Universitätsmedizin Berlin, Berlin, Germany.
  • Falkensammer J; Department of Cardiovascular Surgery, University Hospital Schleswig-Holstein, Kiel, Germany.
J Endovasc Ther ; : 15266028241255533, 2024 May 28.
Article en En | MEDLINE | ID: mdl-38804508
ABSTRACT

PURPOSE:

In some cases of endovascular thoracoabdominal or juxtarenal aortic aneurysm repair, a thoracic endograft in combination with a fenestrated renovisceral device may be needed in order to create a sufficient proximal landing zone. This study aimed to evaluate the technical aspects and postoperative morbidity of a single- or 2-stage approach.

METHODS:

Eighty-seven consecutive patients undergoing thoracic endovascular aortic repair (TEVAR) in combination with elective fenestrated repair (fenestrated endovascular aortic repair [FEVAR]; fenestrated Anaconda device) from 2015 to 2022 were included in this retrospective bicentric study. Underlying pathologies, aortic morphology, technical details, and postoperative morbidity were recorded.

RESULTS:

Single-staged ("1S," n=61) and 2-staged ("2S," n=26) interventions were compared. Indications were thoracoabdominal aneurysms (TAAAs) (Crawford I-IV) (n=56, 64%) and juxtarenal aneurysms (n=31, 36%). In 2S, the proportion of TAAA was higher than in 1S (2S 77%, 1S 59%; p=0.001). In 2S, the covered length of the descending aorta was longer (1S 128±60 mm, 2S 202±64 mm; p=0.003). Temporary aneurysm sack perfusion (TASP) was established in 11 (18%) of 1S and 1 (4%) of 2S patients (p=0.079), as well as cerebrospinal fluid (CSF) drainage catheter in 48 (79%) of 1S and 19 (73%) of 2S. The rate of spinal cord ischemia (SCI) and the severity of SCI were not different in both groups, with a total of 3 cases of persisting paraplegia. The rate of access complications was higher in 2S (n=6, 23%) than in 1S (n=4, 7%; p=0.027). Postoperative 30 day morbidity did not significantly differ in both groups and neither did 30 day mortality (4.6% in 1S vs 3.8% in 2S; p=0.083).

CONCLUSION:

The combination of TEVAR and FEVAR using a fenestrated endograft is feasible and safe. Aortic morphology does not change significantly after endovascular repair. A single-staged strategy is feasible with excellent results, especially in Crawford IV, Crawford V, or juxtarenal aneurysms. Two-staged repair is recommended in cases with long aortic coverage and a higher American Society of Anesthesiologists (ASA) class. Follow-up data are needed to evaluate the long-term stability of the TEVAR/FEVAR interconnection. CLINICAL IMPACT Our study has revealed the safety and efficacy of the combination of TEVAR and FEVAR in the treatment of TAAAs and juxtarenal aneurysms with compromised supravisceral landing zones. A single-staged concept is not necessary in all cases. Staged procedures may reduce postoperative morbidity in cases with long aortic coverage and higher ASA class.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Endovasc Ther Asunto de la revista: ANGIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Endovasc Ther Asunto de la revista: ANGIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Alemania