Your browser doesn't support javascript.
loading
Does Patellar Height Influence Range of Motion and Anterior Knee Pain after Distal Femur Endoprosthesis Reconstruction?
Sambri, Andrea; Paganelli, Chiara; Parisi, Stefania Claudia; Filippini, Matteo; Cevolani, Luca; Stimolo, Davide; Bortoli, Marta; Guarino, Andrea; Bruschi, Alessandro; Fiore, Michele; Campanacci, Domenico Andrea; Donati, Davide Maria; De Paolis, Massimiliano.
Afiliación
  • Sambri A; Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Paganelli C; Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Parisi SC; Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Filippini M; Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Cevolani L; Orthopaedic Oncology Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
  • Stimolo D; Orthopaedic Oncology Unit, Azienda Ospedaliera Universitaria Careggi, 50134 Firenze, Italy.
  • Bortoli M; Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Guarino A; Orthopaedic Oncology Unit, Azienda Ospedaliera Universitaria Careggi, 50134 Firenze, Italy.
  • Bruschi A; Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Fiore M; Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
  • Campanacci DA; Orthopaedic Oncology Unit, Azienda Ospedaliera Universitaria Careggi, 50134 Firenze, Italy.
  • Donati DM; Orthopaedic Oncology Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
  • De Paolis M; Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
J Clin Med ; 13(14)2024 Jul 18.
Article en En | MEDLINE | ID: mdl-39064234
ABSTRACT

Objectives:

This study aims to evaluate the patellar height changes after distal femur (DF) endoprosthetic replacement (EPR) and its impact on anterior knee pain (AKP) and range of motion (ROM).

Methods:

A retrospective review of three institutions' databases was performed. The patellar height was determined using the modified Insall-Salvati ratio (MIS), the Blackburne-Peel (BP) and the Caton-Deschamps (CD) indexes. Data regarding AKP and ROM were collected.

Results:

A total of 199 patients were included. The mean age at presentation was 37.9 ± 23.1 years. The mean one-year follow-up MIS, BP and CD were 1.52 (sd 0.41), 0.82 (sd 0.33) and 0.93 (sd 0.33). Patellar height decreased significantly compared to the pre-operative values according to all three scores (p < 0.001). AKP was reported by 34 (17.1%) patients at 1 year follow-up. Patients with patella baja (MIS < 1.2) or pseudo patella baja (CD < 0.6) had a higher incidence of AKP (p = 0.037 and p = 0.024, respectively). The mean flexion ROM was 91°, with a direct correlation with patellar height (MIS p = 0.020, BP p = 0.036 and CD p = 0.036).

Conclusion:

The restoration of the native position of the joint line in DF EPR is important to maintain optimal patellofemoral biomechanics. Despite surgeons' tendency toward a reduction in patellar height with respect to pre-operative values, an increase in patellar height might help to achieve better knee flexion and reduce AKP.