Your browser doesn't support javascript.
loading
Effectiveness and Safety of Different Patch Materials for Supravalvar Aortic Stenosis (Middle-Term Outcomes).
Lang, Xinyue; Lv, Lizhi; Zhang, Simeng; Zhi, Aihua; Wang, Cheng; Wang, Qiang.
Afiliación
  • Lang X; Medical Research & Biometrics Center, National Center for Cardiovascular Diseases, The National Clinical Research Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, 102300 Beijing, China.
  • Lv L; Department of Pediatric Cardiac Center, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing, China.
  • Zhang S; Department of Cardiac Surgery, Yunnan Fuwai Cardiovascular Hospital, 650102 Kunming, Yunnan, China.
  • Zhi A; Department of Cardiac Surgery, Peking University People's Hospital, 100044 Beijing, China.
  • Wang C; Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, 100037 Beijing, China.
  • Wang Q; Department of Radiology, Yunnan Fuwai Cardiovascular Hospital, 650102 Kunming, Yunnan, China.
Rev Cardiovasc Med ; 25(1): 14, 2024 Jan.
Article en En | MEDLINE | ID: mdl-39077638
ABSTRACT

Background:

To determine the effectiveness and safety of different patch materials in the treatment of pediatric patients with congenital supravalvular aortic stenosis (SVAS).

Methods:

218 consecutive SVAS patients (age < 14 years) who underwent surgery from Beijing Fuwai and Yunnan Fuwai hospital between 2002 and 2020 were included. Patients were divided into the pericardium patch group (133 (61.0%)), modified patch group (43 (19.7%)) and artificial patch group (42 (19.3%)). The primary safety endpoint was patch-related adverse complications (post-operation patch hemorrhage or aortic sinus aneurysm at 2-year follow-up). The primary effectiveness outcome was the re-operation or restenosis at 2-year follow-up. Multivariable cox regression was used to obtain the hazard ratio (HR).

Results:

The median age at operation was 43.5 months (IQR 24.0-73.0). Only three patients had patch-related adverse complications, and no difference existed among the three groups (p = 0.763). After a median follow-up of 24.0 months (IQR 6.0-48.0), patients with a pericardium patch had a lower re-operation or restenosis rate compared with the other two groups (pericardium patch vs modified patch, HR = 0.30, 95% CI 0.12-0.77; pericardium patch vs artificial patch, HR = 0.33, 95% CI 0.13-0.82), even in the main subgroup and sensitivity analysis.

Conclusions:

In pediatric patients, the safety of autologous pericardium patch is acceptable, along with lower rates of middle-term re-operation or restenosis. Clinical Trial Registration http//www.chictr.org.cn, number ChiCTR2300067851.