Your browser doesn't support javascript.
loading
Open-Globe Injury With Globe Penetration Leading to Complex Retinal Detachment After Intraoral Anesthetic Injection.
Trejo Corona, Stephanie; Parvus, Matthew N; Fan, Kenneth C; Patel, Sagar B; Lane, R Gary; Flynn, Harry W; Wykoff, Charles C.
Afiliación
  • Trejo Corona S; Retina Consultants of Texas, Retina Consultants of America, Houston, TX, USA.
  • Parvus MN; Retina Consultants of Texas, Retina Consultants of America, Houston, TX, USA.
  • Fan KC; Retina Consultants of Texas, Retina Consultants of America, Houston, TX, USA.
  • Patel SB; Blanton Eye Institute, Houston Methodist Hospital, Houston, TX, USA.
  • Lane RG; Retina Consultants of Texas, Retina Consultants of America, Houston, TX, USA.
  • Flynn HW; Blanton Eye Institute, Houston Methodist Hospital, Houston, TX, USA.
  • Wykoff CC; Retina Consultants of Texas, Retina Consultants of America, Houston, TX, USA.
J Vitreoretin Dis ; 8(4): 480-484, 2024.
Article en En | MEDLINE | ID: mdl-39148572
ABSTRACT

Purpose:

To report a case of a suspected open-globe injury and globe penetration complicated by a rhegmatogenous retinal detachment (RRD) after administration of intraoral anesthetic injections during an endodontic procedure.

Methods:

A retrospective chart review was performed.

Results:

A 34-year-old woman presented with acute onset of flashes, floaters, and a curtain-like shadow across her field of vision. Four days previously, she had multiple left-sided anesthetic injections during an endodontic procedure. The visual acuity (VA) in the left eye was 20/25. Ophthalmoscopy showed a suspected globe-penetration site inferiorly, associated multilayered hemorrhages, and adjacent subretinal fluid. Laser demarcation of the inferior RRD was performed at sequential clinical visits. Through 8 months, the multilayered hemorrhages improved while proliferative vitreoretinopathy-associated tissue formation over the posterior pole caused macular distortion and mild visual deterioration. The VA in the left eye was 20/40 at the last follow-up.

Conclusions:

Iatrogenic globe penetration during intraoral anesthesia delivery associated with an endodontic procedure may result in globe injury.