Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Pediatr ; 271: 114043, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38561049

RESUMEN

OBJECTIVE: The objective of this study was to predict extubation readiness in preterm infants using machine learning analysis of bedside pulse oximeter and ventilator data. STUDY DESIGN: This is an observational study with prospective recordings of oxygen saturation (SpO2) and ventilator data from infants <30 weeks of gestation age. Research pulse oximeters collected SpO2 (1 Hz sampling rate) to quantify intermittent hypoxemia (IH). Continuous ventilator metrics were collected (4-5-minute sampling) from bedside ventilators. Data modeling was completed using unbiased machine learning algorithms. Three model sets were created using the following data source combinations: (1) IH and ventilator (IH + SIMV), (2) IH, and (3) ventilator (SIMV). Infants were also analyzed separated by postnatal age (infants <2 or ≥2 weeks of age). Models were compared by area under the receiver operating characteristic curve (AUC). RESULTS: A total of 110 extubation events from 110 preterm infants were analyzed. Infants had a median gestation age and birth weight of 26 weeks and 825 g, respectively. Of the 3 models presented, the IH + SIMV model achieved the highest AUC of 0.77 for all infants. Separating infants by postnatal age increased accuracy further achieving AUC of 0.94 for <2 weeks of age group and AUC of 0.83 for ≥2 weeks group. CONCLUSIONS: Machine learning analysis has the potential to enhance prediction accuracy of extubation readiness in preterm infants while utilizing readily available data streams from bedside pulse oximeters and ventilators.


Asunto(s)
Extubación Traqueal , Recien Nacido Prematuro , Aprendizaje Automático , Oximetría , Humanos , Recién Nacido , Estudios Prospectivos , Masculino , Femenino , Oximetría/métodos , Hipoxia/diagnóstico , Saturación de Oxígeno , Desconexión del Ventilador/métodos , Curva ROC , Edad Gestacional
2.
Pediatr Res ; 96(3): 766-772, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38600299

RESUMEN

BACKGROUND: Intermittent hypoxemia (IH) may influence retinopathy of prematurity (ROP) development in preterm infants, however, previous studies had mixed results. This study tests the hypothesis that increased IH is associated with Type 1 ROP; a stage beyond which treatment is indicated. METHODS: IH was quantified by continuously monitoring oxygen saturation (SpO2) using high-resolution pulse oximeters during the first 10 weeks of life. Statistical analyses assessed the relationship and predictive ability of weekly and cumulative IH for Type 1 ROP development. RESULTS: Most analyses showed no association between IH and Type 1 ROP adjusting for gestational age (GA) and birth weight (BW). However, cumulative IH of longer duration during weeks 5-10, 6-10, and 7-10 were significantly associated with Type 1 ROP adjusting for GA and BW, e.g., the adjusted odds ratio of Type 1 ROP was 2.01 (p = 0.03) for every 3.8 seconds increase in IH duration from week 6-10. IH did not provide statistically significant added predictive ability above GA and BW. CONCLUSIONS: For most analyses there was no significant association between IH and Type 1 ROP adjusting for GA and BW. However, infants with longer IH duration during the second month of life had higher risk for Type 1 ROP. IMPACT: The relationship and predictive ability of intermittent hypoxemia (IH) on retinopathy of prematurity (ROP) is controversial. This study shows no significant association between IH events and Type 1 ROP after adjusting for gestational age (GA) and birth weight (BW), except for cumulative IH of longer duration in the second month of life. In this cohort, IH does not provide a statistically significant improvement in ROP prediction over GA and BW. This study is the first to assess the cumulative impact of IH measures on Type 1 ROP. Interventions for reducing IH duration during critical postnatal periods may improve ROP outcomes.


Asunto(s)
Peso al Nacer , Edad Gestacional , Hipoxia , Recien Nacido Prematuro , Retinopatía de la Prematuridad , Humanos , Retinopatía de la Prematuridad/etiología , Recién Nacido , Masculino , Femenino , Oximetría , Factores de Riesgo , Saturación de Oxígeno , Oportunidad Relativa
3.
Pediatr Res ; 96(2): 486-493, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38503982

RESUMEN

BACKGROUND: Unstable cerebral hemodynamics places preterm infants at high risk of brain injury. We adapted an innovative, fiber-free, wearable diffuse speckle contrast flow-oximetry (DSCFO) device for continuous monitoring of both cerebral blood flow (CBF) and oxygenation in neonatal piglets and preterm infants. METHODS: DSCFO uses two small laser diodes as focused-point and a tiny CMOS camera as a high-density two-dimensional detector to detect spontaneous spatial fluctuation of diffuse laser speckles for CBF measurement, and light intensity attenuations for cerebral oxygenation measurement. The DSCFO was first validated against the established diffuse correlation spectroscopy (DCS) in neonatal piglets and then utilized for continuous CBF and oxygenation monitoring in preterm infants during intermittent hypoxemia (IH) events. RESULTS: Significant correlations between the DSCFO and DCS measurements of CBF variations in neonatal piglets were observed. IH events induced fluctuations in CBF, cerebral oxygenation, and peripheral cardiorespiratory vitals in preterm infants. However, no consistent correlation patterns were observed among peripheral and cerebral monitoring parameters. CONCLUSIONS: This pilot study demonstrated the feasibility of DSCFO technology to serve as a low-cost wearable sensor for continuous monitoring of multiple cerebral hemodynamic parameters. The results suggested the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations. IMPACT: The innovative DSCFO technology may serve as a low-cost wearable sensor for continuous bedside monitoring of multiple cerebral hemodynamic parameters in neonatal intensive care units. Concurrent DSCFO and DCS measurements of CBF variations in neonatal piglet models generated consistent results. No consistent correlation patterns were observed among peripheral and cerebral monitoring parameters in preterm neonates, suggesting the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations during IH events. Integrating and correlating multiple cerebral functional parameters with clinical outcomes may identify biomarkers for prediction and management of IH associated brain injury.


Asunto(s)
Animales Recién Nacidos , Circulación Cerebrovascular , Oximetría , Oxígeno , Dispositivos Electrónicos Vestibles , Animales , Recién Nacido , Humanos , Porcinos , Oximetría/instrumentación , Oximetría/métodos , Oxígeno/metabolismo , Oxígeno/sangre , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Proyectos Piloto , Recien Nacido Prematuro , Hemodinámica , Hipoxia , Femenino , Masculino , Encéfalo/irrigación sanguínea
4.
Am J Perinatol ; 38(12): 1313-1319, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-32512605

RESUMEN

OBJECTIVE: A major consequence of prematurity is intermittent hypoxemia (IH). Data from both adult studies and neonatal animal models suggest that IH is proinflammatory; however, there is limited data in preterm infants. Here, we assess the relationship between IH and systemic inflammation, namely, serum C-reactive protein (CRP) in preterm infants. STUDY DESIGN: Serum CRP was measured at 30 days of life, at the time of peak IH frequency. IH measures (e.g., per cent time in hypoxemia, frequency, duration) were calculated the week prior to CRP collection. Statistical analyses were based on Spearman's correlation. RESULTS: A total of 26 infants were included. Median gestational age and birth weight were 274/7 weeks and 980 g, respectively. There were positive correlations between primary IH measures and CRP levels, especially for events longer than 1-minute duration (r range: 0.56-0.74, all p < 0.01). CONCLUSION: We demonstrate that IH is associated with increased CRP for the first time in preterm infants. Our findings are consistent with studies from adults and neonatal animal models suggesting that IH is a proinflammatory process. KEY POINTS: · IH events are common.. · IH is associated with elevated C-reactive protein.. · Longer IH events (>1 min) are of most significance..


Asunto(s)
Proteína C-Reactiva/análisis , Hipoxia/complicaciones , Enfermedades del Prematuro , Inflamación/etiología , Peso al Nacer , Femenino , Edad Gestacional , Humanos , Hipoxia/sangre , Recien Nacido Extremadamente Prematuro , Recién Nacido , Recien Nacido Prematuro , Masculino , Estudios Prospectivos
5.
Neuroimage ; 198: 160-169, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31112789

RESUMEN

Continuous and longitudinal imaging of cerebral blood flow (CBF) variations provide vital information to investigate pathophysiology and interventions for a variety of neurological and cerebral diseases. An innovative noncontact speckle contrast diffuse correlation tomography (scDCT) system was downscaled and adapted for noninvasive imaging of CBF distributions in rat brain through intact scalp and skull. Algorithms for 2D mapping and 3D image reconstruction of CBF distributions were developed and optimized. The continuous imaging capability of the system was shown by imaging global CBF increases during CO2 inhalations and regional CBF decreases across two hemispheres during sequential unilateral and bilateral common carotid artery ligations. The longitudinal imaging capability was demonstrated by imaging CBF variations over a long recovery period of 14 days after an acute stroke. Compared to the 2D mapping method, the 3D imaging method reduces partial volume effects, but needs more computation time for image reconstruction. Results from this study generally agree with those reported in the literature using similar protocols to induce CBF changes in rats. The scDCT enables a relatively large penetration depth (up to ∼10 mm), which is sufficient for transcranial brain measurements in small animals and human neonates. Ultimately, we expect to provide a noninvasive noncontact cerebral imager for basic neuroscience research in small animal models and clinical applications in human neonates.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Imagen Óptica/métodos , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía/métodos , Animales , Encéfalo/fisiopatología , Isquemia Encefálica/fisiopatología , Circulación Cerebrovascular , Imagenología Tridimensional/métodos , Masculino , Imagen Óptica/instrumentación , Ratas Sprague-Dawley , Accidente Cerebrovascular/fisiopatología , Tomografía/instrumentación
6.
Pediatr Res ; 85(3): 318-323, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30538265

RESUMEN

BACKGROUND: Bronchopulmonary dysplasia (BPD) is a chronic lung disease and major pulmonary complication after premature birth. We have previously shown that increased intermittent hypoxemia (IH) events have been correlated to adverse outcomes and mortality in extremely premature infants. We hypothesize that early IH patterns are associated with the development of BPD. METHODS: IH frequency, duration, and nadirs were assessed using oxygen saturation (SpO2) waveforms in a retrospective cohort of 137 extremely premature newborns (<28 weeks gestation). Daily levels of inspired oxygen and mean airway pressure exposures were also recorded. RESULTS: Diagnosis of BPD at 36 weeks postmenstrual age was associated with increased daily IH, longer IH duration, and a higher IH nadir. Significant differences were detected through day 7 to day 26 of life. Infants who developed BPD had lower mean SpO2 despite their exposure to increased inspired oxygen and increased mean airway pressure. CONCLUSIONS: BPD was associated with more frequent, longer, and less severe IH events in addition to increased oxygen and pressure exposure within the first 26 days of life. Early IH patterns may contribute to the development of BPD or aid in identification of neonates at high risk.


Asunto(s)
Displasia Broncopulmonar/diagnóstico , Hipoxia/diagnóstico , Enfermedades del Recién Nacido/diagnóstico , Displasia Broncopulmonar/complicaciones , Femenino , Edad Gestacional , Humanos , Hipoxia/complicaciones , Recien Nacido Extremadamente Prematuro , Recién Nacido , Recién Nacido de muy Bajo Peso , Cuidado Intensivo Neonatal , Masculino , Oximetría , Oxígeno/metabolismo , Presión , Estudios Retrospectivos , Resultado del Tratamiento
7.
Artículo en Inglés | MEDLINE | ID: mdl-31666792

RESUMEN

Continuous and longitudinal monitoring of cerebral blood flow (CBF) in animal models provides information for studying the mechanisms and interventions of various cerebral diseases. Since anesthesia may affect brain hemodynamics, researchers have been seeking wearable devices for use in conscious animals. We present a wearable diffuse speckle contrast flowmeter (DSCF) probe for monitoring CBF variations in mice. The DSCF probe consists of a small low-power near-infrared laser diode as a point source and an ultra-small low-power CMOS camera as a 2D detector array, which can be affixed on a mouse head. The movement of red blood cells in brain cortex (i.e., CBF) produces spatial fluctuations of laser speckles, which are captured by the camera. The DSCF system was calibrated using tissue phantoms and validated in a human forearm and mouse brains for continuous monitoring of blood flow increases and decreases against the established technologies. Significant correlations were observed among these measurements (R2 ≥ 0.80, p < 10-5). This small fiberless probe has the potential to be worn by a freely moving conscious mouse. Moreover, the flexible source-detector configuration allows for varied probing depths up to ~8 mm, which is sufficient for transcranially detecting CBF in the cortices of rodents and newborn infants.

8.
Transfusion ; 58(11): 2538-2544, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30291755

RESUMEN

BACKGROUND: Red blood cell (RBC) transfusion decreases intermittent hypoxemia (IH) events beyond the first week of life. This benefit may be related to improved perfusion to the respiratory control network. Perfusion index (PI) is a perfusion measure provided by the pulse oximeter. We hypothesized that the benefit in IH after RBC transfusion is associated with an increase in PI. In addition, we assessed the value of PI and clinical measures in predicting the effect of RBC transfusion on IH. STUDY DESIGN AND METHODS: We prospectively enrolled infants less than 30 weeks' gestation age. PI and oxygen saturation (SpO2 ) were monitored with high-resolution pulse oximeters 24 hours before and after RBC transfusion. Data were analyzed at three postnatal periods: Epoch 1, first week of life (1 to 7 days of life); Epoch 2, 2 to 4 weeks of life (8 to 28 days of life); and Epoch 3, 4 to 8 weeks of life. RESULTS: A total of 118 transfusions were analyzed. IH measures significantly decreased after transfusion in Epochs 2 and 3. PI significantly increased after transfusion, but it did not correlate with the decrease in IH measures. Mechanical ventilation, fraction of inspired oxygen (FiO2 ), and IH measures influenced the effects on oxygenation. CONCLUSIONS: RBC transfusion improved IH after the first week of life. The benefit in IH did not correlate with PI increase after transfusion. Pretransfusion respiratory support and IH measures predicted the effect of transfusion on oxygenation.


Asunto(s)
Hipoxia/terapia , Transfusión de Eritrocitos/métodos , Femenino , Edad Gestacional , Humanos , Concentración de Iones de Hidrógeno , Recien Nacido Prematuro , Enfermedades del Prematuro , Masculino , Embarazo , Estudios Prospectivos
9.
Pediatr Res ; 81(5): 775-779, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28099422

RESUMEN

BACKGROUND: Perfusion index (PI) is a noninvasive measure of perfusion. ΔPI (difference between pre- and postductal PI) may identify hemodynamically significant PDA. However, studies are limited to brief and intermittent ΔPI sampling. Our objective is to assess the value of continuous high resolution ΔPI monitoring in the diagnosis of PDA. METHODS: Continuous ΔPI monitoring in preterm infants was prospectively performed using two high-resolution pulse oximeters. Perfusion Index measures (ΔPI mean and variability, pre- and postductal PI) were analyzed over a 4-h period prior to echocardiography. A cardiologist blinded to the results evaluated for PDA on echocardiography. Linear mixed regression models were utilized for analyses. RESULTS: We obtained 31 echocardiography observations. Mean ΔPI (-0.23 vs. 0.16; P < 0.05), mean pre-PI (0.86 vs. 1.26; P < 0.05), and ΔPI variability (0.39 vs. 0.61; P = 0.05) were lower in infants with PDA compared to infants without PDA at the time of echocardiography. CONCLUSION: Mean ΔPI, ΔPI variability, and mean pre-PI measured 4 h prior to echocardiography detect PDA in preterm infants. PI is dynamic and should be assessed continuously. Perfusion index is a promising bedside measurement to identify PDA in preterm infants.


Asunto(s)
Circulación Coronaria , Conducto Arterioso Permeable/fisiopatología , Recien Nacido Extremadamente Prematuro , Flujo Pulsátil , Biomarcadores/sangre , Conducto Arterioso Permeable/sangre , Conducto Arterioso Permeable/diagnóstico por imagen , Ecocardiografía Doppler en Color , Femenino , Edad Gestacional , Humanos , Recién Nacido , Modelos Lineales , Masculino , Oximetría , Oxígeno/sangre , Pruebas en el Punto de Atención , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo
10.
medRxiv ; 2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37808800

RESUMEN

Background: Intermittent hypoxemia (IH) may influence retinopathy of prematurity (ROP) development in preterm infants, however, previous studies had mixed results. This study aims to assess the influence and evaluate the predictive ability of IH measures on Type 1 ROP, a stage beyond which ROP treatment is indicated. Methods: IH was quantified by continuously monitoring oxygen saturation (SpO2) using high-resolution pulse oximeters during the first 10 weeks of life. Statistical analyses assessed the relationship and predictive ability of weekly and cumulative IH variables for Type 1 ROP development. Results: Univariate analyses suggested that IH measures are greater in infants with Type 1 ROP and are predictive of Type 1 ROP development. Multivariable logistic regression analyses revealed that cumulative IH of longer duration during certain postnatal periods are associated with Type 1 ROP development after adjusting for gestational age (GA) or birth weight (BW). Although area under the curve (AUC) analyses revealed added predictivity of cumulative IH variables above GA or BW, these increments in AUC were not statistically significant. Conclusions: The duration of IH events was associated with Type 1 ROP development. Interventions for reducing the duration of IH events may potentially improve ROP outcomes.

11.
J Perinatol ; 43(5): 653-658, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36581761

RESUMEN

OBJECTIVE: Describe the effects of the COVID-19 pandemic on subject enrollment in a multicenter randomized controlled trial. STUDY DESIGN: We assessed the number of eligible infants approached and consented for enrollment over five separate epochs including baseline, peak pandemic, and gradual but incomplete recovery. RESULT: The pandemic had a major effect on ability to approach parents for consent. Parents approached dropped from 95.4% baseline to 13.1% in the peak pandemic epoch and has not recovered to baseline even in the just-completed post-pandemic epoch (84.9%). Despite the decrease in subjects approached, there was no significant change in the overall consent rate for the study CONCLUSION: The pandemic has significantly limited ability to approach parents of eligible infants for consent, with only partial recovery. Opportunities for interactions of investigators and study coordinators with parents continue to present challenges limiting full recovery.


Asunto(s)
COVID-19 , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Lactante , Humanos , Pandemias , Padres
12.
medRxiv ; 2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37790418

RESUMEN

Impact: The innovative DSCFO technology may serve as a low-cost wearable sensor for continuous bedside monitoring of multiple cerebral hemodynamic parameters in neonatal intensive care units.Concurrent DSCFO and DCS measurements of CBF variations in neonatal piglet models generated consistent results.No consistent correlation patterns were observed among peripheral and cerebral monitoring parameters in preterm neonates, suggesting the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations during IH events.Integrating and correlating multiple cerebral functional parameters with clinical outcomes may identify biomarkers for prediction and management of IH associated brain injury. Background: Unstable cerebral hemodynamics places preterm infants at high risk of brain injury. We adapted an innovative, fiber-free, wearable diffuse speckle contrast flow-oximetry (DSCFO) device for continuous monitoring of both cerebral blood flow (CBF) and oxygenation in neonatal piglets and preterm infants. Methods: DSCFO uses two small laser diodes as focused-point and a tiny CMOS camera as a high-density two-dimensional detector to detect spontaneous spatial fluctuation of diffuse laser speckles for CBF measurement, and light intensity attenuations for cerebral oxygenation measurement. The DSCFO was first validated against the established diffuse correlation spectroscopy (DCS) in neonatal piglets and then utilized for continuous CBF and oxygenation monitoring in preterm infants during intermittent hypoxemia (IH) events. Results: Consistent results between the DSCFO and DCS measurements of CBF variations in neonatal piglets were observed. IH events induced fluctuations in CBF, cerebral oxygenation, and peripheral cardiorespiratory vitals in preterm infants. However, no consistent correlation patterns were observed among peripheral and cerebral monitoring parameters. Conclusions: This pilot study demonstrated the feasibility of DSCFO technology to serve as a low-cost wearable sensor for continuous monitoring of multiple cerebral hemodynamic parameters. The results suggested the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations.

13.
Children (Basel) ; 8(6)2021 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-34200535

RESUMEN

Currently, the administration of surfactant to preterm infants with respiratory distress syndrome (RDS) mainly relies on intratracheal instillation; however, there is increasing evidence of aerosolized surfactant being an effective non-invasive strategy. We present a historical narrative spanning sixty years of development of aerosolization systems. We also offer an overview of the pertinent mechanisms needed to create and manage the ideal aerosolization system, with a focus on delivery, distribution, deposition, and dispersion in the context of the human lung. More studies are needed to optimize treatment with aerosolized surfactants, including determination of ideal dosages, nebulizer types, non-invasive interfaces, and breath synchronization. However, the field is rapidly evolving, and widespread clinical use may be achieved in the near future.

14.
Children (Basel) ; 8(3)2021 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-33803800

RESUMEN

Preterm infants with respiratory distress may require mechanical ventilation which is associated with increased pulmonary morbidities. Prompt and successful extubation to noninvasive support is a pressing goal. In this communication, we show original data that increased recurring intermittent hypoxemia (IH, oxygen saturation <80%) may be associated with extubation failure at 72 h in a cohort of neonates <30 weeks gestational age. Current-generation bedside high-resolution pulse oximeters provide saturation profiles that may be of use in identifying extubation readiness and failure. A larger prospective study that utilizes intermittent hypoxemia as an adjunct predictor for extubation readiness is warranted.

15.
J Perinatol ; 41(7): 1704-1710, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34035457

RESUMEN

BACKGROUND: Bronchodilator responses among preterm infants are heterogeneous. Bedside measurements may identify responders. STUDY DESIGN: Respiratory measurements (Resistance, Compliance, FiO2) and pulse oximetry (SpO2) patterns were downloaded from infants <30 weeks gestational age during the first 2 months of life. Mechanically ventilated infants who received albuterol were included (n = 33). Measurements were compared before and after first albuterol. Secondary analyses assessed subsequent doses. RESULTS: Median gestation and birthweight were 25 3/7 weeks and 730 g, respectively. Mean Resistance decreased post-albuterol (p = 0.007). Sixty-eight percent of infants were responders based on decreased Resistance. Compliance and FiO2 did not significantly differ. Percent time in hypoxemia (SpO2 < 85%) decreased post albuterol (p < 0.02). In responders, Resistance changes diminished with subsequent administration (all p = 0.01). CONCLUSIONS: Ventilator resistance decreased in two-thirds of preterm infants, consistent with studies that utilized formal pulmonary function testing. Albuterol had a variable effect on delivered FiO2; however, hypoxemia may be useful in evaluating albuterol response.


Asunto(s)
Albuterol , Respiración Artificial , Broncodilatadores , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Oximetría
16.
Arch Dis Child Fetal Neonatal Ed ; 106(5): 557-559, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33597229

RESUMEN

Intermittent hypoxaemia (IH) events are well described in extremely preterm infants, but the occurrence of IH patterns in more mature preterm infants remains unclear. The objective of this study was to characterise the effect of gestational age on early postnatal patterns of IH in extremely (<28 weeks), very (28-<32 weeks) and moderately (32-<34 weeks) preterm infants. As expected, extremely preterm infants had a significantly higher frequency of IH events of longer durations and greater time with hypoxaemia versus very and moderately preterm infants. In addition, the postnatal decrease in IH duration was comparable in the very and moderately preterm infants. This progression of IH events should assist clinicians and families in managing expectations for resolution of IH events during early postnatal life.


Asunto(s)
Hipoxia/fisiopatología , Enfermedades del Prematuro/fisiopatología , Edad Gestacional , Humanos , Recien Nacido Extremadamente Prematuro , Recién Nacido , Recien Nacido Prematuro , Estudios Retrospectivos , Factores de Tiempo
17.
J Biomed Opt ; 26(1)2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33515216

RESUMEN

SIGNIFICANCE: There is an essential need to develop wearable multimodality technologies that can continuously measure both blood flow and oxygenation in deep tissues to investigate and manage various vascular/cellular diseases. AIM: To develop a wearable dual-wavelength diffuse speckle contrast flow oximetry (DSCFO) for simultaneous measurements of blood flow and oxygenation variations in deep tissues. APPROACH: A wearable fiber-free DSCFO probe was fabricated using 3D printing to confine two small near-infrared laser diodes and a tiny CMOS camera in positions for DSCFO measurements. The spatial diffuse speckle contrast and light intensity measurements at the two different wavelengths enable quantification of tissue blood flow and oxygenation, respectively. The DSCFO was first calibrated using tissue phantoms and then tested in adult forearms during artery cuff occlusion. RESULTS: Phantom tests determined the largest effective source-detector distance (15 mm) and optimal camera exposure time (10 ms) and verified the accuracy of DSCFO in measuring absorption coefficient variations. The DSCFO detected substantial changes in forearm blood flow and oxygenation resulting from the artery occlusion, which meet physiological expectations and are consistent with previous study results. CONCLUSIONS: The wearable DSCFO may be used for continuous and simultaneous monitoring of blood flow and oxygenation variations in freely behaving subjects.


Asunto(s)
Hemodinámica , Dispositivos Electrónicos Vestibles , Adulto , Antebrazo , Humanos , Oximetría , Fantasmas de Imagen
18.
Neonatology ; 117(6): 776-779, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33378753

RESUMEN

We report a case of contrast-induced hypothyroidism in an extremely preterm infant after percutaneous patent ductus arteriosus (PDA) device closure. Iodine-induced hypothyroidism after exposure to iodine-containing antiseptics and contrast media has been previously reported in extremely preterm infants. However, this is the first report of contrast-induced hypothyroidism in an extremely preterm infant undergoing percutaneous PDA device closure. This is timely, given percutaneous PDA device closure is more frequently utilized. Guidelines for screening thyroid function pre and post contrast-requiring procedures may be warranted. Hypothyroidism if left untreated can have detrimental effects on developing brain, especially in the preterm population. Therefore, the earlier detection and treatment of iodine-induced hypothyroidism is imperative.


Asunto(s)
Conducto Arterioso Permeable , Hipotiroidismo , Medios de Contraste/efectos adversos , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/cirugía , Humanos , Lactante , Recien Nacido Extremadamente Prematuro , Recién Nacido
19.
Phys Med Biol ; 65(24): 245009, 2020 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-33113516

RESUMEN

Extremely preterm infants' hemodynamic instability places them at high risk of brain injury. Currently there is no reliable bedside method to continuously monitor cerebral hemodynamics in the neonatal intensive care unit (NICU). This paper reports a feasibility study to adapt and test an innovative speckle contrast diffuse correlation tomography (scDCT) device for noncontact, high-density, 3D imaging of cerebral blood flow (CBF) in preterm infants. The scDCT scans a focused point near-infrared illumination to multiple source positions for deep tissue penetration, and controls an electron multiplying charge-coupled-device camera with thousands of pixels to achieve a high-density sampling. The optimized scDCT for use in preterm infants was first evaluated against an established diffuse correlation spectroscopy in an infant-head-simulating phantom with known properties. The observed significant correlation between the two measurements verified the capability of scDCT for transcranial brain imaging. The insignificant influence of transparent incubator wall on scDCT measurements was then confirmed by comparing adult forearm blood flow responses to artery cuff occlusions measured inside and outside the incubator. Finally, the scDCT device was moved to the NICU to image CBF variations in two preterm infants. Infant #1 with no major organ deficits showed little CBF fluctuation over the first 3 weeks of life. Infant #2 showed a significant CBF increase after the 2 h pharmacotherapy for patent ductus arteriosus closure. While these CBF variations meet physiological expectations, the fact that no significant changes are noted with peripheral monitoring of blood oxygen saturation suggests necessity of direct cerebral monitoring. This feasibility study with timely technology development is an important and necessary step towards larger clinical studies with more subjects to further validate it for continuous monitoring and instant management of cerebral pathologies and interventions in the NICU.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Hemodinámica , Recien Nacido Prematuro , Imagen Óptica/métodos , Circulación Cerebrovascular , Estudios de Factibilidad , Femenino , Humanos , Recién Nacido , Masculino , Fantasmas de Imagen , Tomografía
20.
Pediatrics ; 146(2)2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32665372

RESUMEN

OBJECTIVES: To determine if a home oxygen therapy (HOT) management strategy that includes analysis of recorded home oximetry (RHO) data, compared with standard monthly clinic visit assessments, reduces duration of HOT without harm in premature infants. METHODS: The RHO trial was an unmasked randomized clinical trial conducted in 9 US medical centers from November 2013 to December 2017, with follow-up to February 2019. Preterm infants with birth gestation ≤37 + 0/7 weeks, discharged on HOT, and attending their first pulmonary visit were enrolled. The intervention was an analysis of transmitted RHO between clinic visits (n = 97); the standard-care group received monthly clinic visits with in-clinic weaning attempts (n = 99). The primary outcomes were the duration of HOT and parent-reported quality of life. There were 2 prespecified secondary safety outcomes: change in weight and adverse events within 6 months of HOT discontinuation. RESULTS: Among 196 randomly assigned infants (mean birth gestational age: 26.9 weeks; SD: 2.6 weeks; 37.8% female), 166 (84.7%) completed the trial. In the RHO group, the mean time to discontinue HOT was 78.1 days (SE: 6.4), compared with 100.1 days (SE: 8.0) in the standard-care group (P = .03). The quality-of-life scores improved from baseline to 3 months after discontinuation of HOT in both groups (P = .002), but the degree of improvement did not differ significantly between groups (P = .75). CONCLUSIONS: RHO was effective in reducing the duration of HOT in premature infants. Parent quality of life improved after discontinuation. RHO allows physicians to determine which infants can be weaned and which need prolonged oxygen therapy between monthly visits.


Asunto(s)
Displasia Broncopulmonar/terapia , Servicios de Atención a Domicilio Provisto por Hospital , Oximetría , Terapia por Inhalación de Oxígeno , Peso Corporal , Femenino , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Masculino , Estudios Multicéntricos como Asunto , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA