Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
PLoS Negl Trop Dis ; 15(8): e0009649, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34383774

RESUMEN

BACKGROUND: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a common enzyme deficiency, prevalent in many malaria-endemic countries. G6PD-deficient individuals are susceptible to hemolysis during oxidative stress, which can occur from exposure to certain medications, including 8-aminoquinolines used to treat Plasmodium vivax malaria. Accordingly, access to point-of-care (POC) G6PD testing in Brazil is critical for safe treatment of P. vivax malaria. METHODOLOGY/PRINCIPAL FINDINGS: This study evaluated the performance of the semi-quantitative, POC STANDARD G6PD Test (SD Biosensor, Republic of Korea). Participants were recruited at clinics and through an enriched sample in Manaus and Porto Velho, Brazil. G6PD and hemoglobin measurements were obtained from capillary samples at the POC using the STANDARD and HemoCue 201+ (HemoCue AB, Sweden) tests. A thick blood slide was prepared for malaria microscopy. At the laboratories, the STANDARD and HemoCue tests were repeated on venous samples and a quantitative spectrophotometric G6PD reference assay was performed (Pointe Scientific, Canton, MI). G6PD was also assessed by fluorescent spot test. In Manaus, a complete blood count was performed. Samples were analyzed from 1,736 participants. In comparison to spectrophotometry, the STANDARD G6PD Test performed equivalently in determining G6PD status in venous and capillary specimens under varied operating temperatures. Using the manufacturer-recommended reference value thresholds, the test's sensitivity at the <30% threshold on both specimen types was 100% (95% confidence interval [CI] venous 93.6%-100.0%; capillary 93.8%-100.0%). Specificity was 98.6% on venous specimens (95% CI 97.9%-99.1%) and 97.8% on capillary (95% CI 97.0%-98.5%). At the 70% threshold, the test's sensitivity was 96.9% on venous specimens (95% CI 83.8%-99.9%) and 94.3% on capillary (95% CI 80.8%-99.3%). Specificity was 96.5% (95% CI 95.0%-97.6%) and 92.3% (95% CI 90.3%-94.0%) on venous and capillary specimens, respectively. CONCLUSION/SIGNIFICANCE: The STANDARD G6PD Test is a promising tool to aid in POC detection of G6PD deficiency in Brazil. TRIAL REGISTRATION: This study was registered with ClinicalTrials.gov (identifier: NCT04033640).


Asunto(s)
Técnicas Biosensibles , Deficiencia de Glucosafosfato Deshidrogenasa/diagnóstico , Glucosafosfato Deshidrogenasa/sangre , Pruebas en el Punto de Atención/normas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aminoquinolinas/uso terapéutico , Antimaláricos/uso terapéutico , Brasil , Niño , Preescolar , Estudios Transversales , Femenino , Deficiencia de Glucosafosfato Deshidrogenasa/sangre , Hemólisis , Humanos , Modelos Lineales , Malaria Vivax/complicaciones , Malaria Vivax/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Curva ROC , Adulto Joven
2.
Wellcome Open Res ; 5: 21, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32766454

RESUMEN

Safe access to the most effective treatment options for  Plasmodium vivax malaria are limited by the absence of accurate point-of-care testing to detect glucose-6-phosphate dehydrogenase (G6PD) deficiency, the most common human genetic disorder. G6PD-deficient patients are at risk of life-threatening hemolysis when exposed to 8-aminoquinolines, the only class of drugs efficacious against  P. vivax hypnozoites. Until recently, only qualitative tests were available in most settings. These can identify patients with severe G6PD deficiency (mostly male) but not patients with intermediate G6PD deficiency (always female). This has led to and reinforced a gap in awareness in clinical practice of the risks and implications of G6PD deficiency in females-who, unlike males, can have a heterozygous genotype for G6PD. Increasing recognition of the need for radical cure of   P. vivax, first for patients' health and then for malaria elimination, is driving the development of new point-of-care tests for G6PD deficiency and their accessibility to populations in low-resource settings. The availability of user-friendly, affordable, and accurate quantitative point-of-care diagnostics for the precise classification of the three G6PD phenotypes can reduce sex-linked disparities by ensuring safe and effective malaria treatment, providing opportunities to develop supportive counseling to enhance understanding of genetic test results, and improving the detection of all G6PD deficiency phenotypes in newborns and their family members.

3.
PLoS One ; 15(3): e0230333, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32163502

RESUMEN

In low- and middle-income countries, many women experience anemia during pregnancy due to insufficient dietary intake of key micronutrients, parasitic infections, hemoglobinopathies, and chronic infections. Maternal anemia increases perinatal risks for both mothers and infants, and slow progress to reduce the prevalence may be due in part to the lack of affordable tools to quantify hemoglobin levels in antenatal care (ANC) clinics. A simple, inexpensive, accurate, and robust diagnostic is needed to measure hemoglobin in ANC. This study evaluated the performance and usability of the TrueHb Hemometer. A cross-sectional diagnostic accuracy study was conducted to compare the accuracy of the TrueHb and the HemoCue® 201+ using capillary samples. Next, analytical performance (precision, coefficient of variation, R2) of the TrueHb was evaluated in varying environmental conditions using linearity panels with serial dilutions of venous blood samples. Lastly, the usability of the TrueHb Hemometer was assessed across three domains (effectiveness, efficiency, and satisfaction) by 20 ANC providers in Ghana. Capillary blood test results were not well correlated (R2 = 0.35) between the TrueHB and HemoCue201+, but 80% of TrueHb measurements were within +/-1.0 g/dl of the HemoCue® 201+ hemoglobin values. Precision tests indicated similar mean values across the three environmental conditions (CV<6%). At 21°C, the TrueHb follows a linear relationship (R2≥0.96) but does not generate accurate readings below 4.0 g/dl. At 30°C and 37°C, the TrueHb follows a linear relationship (R2 > 0.90) but begins to underestimate the hemoglobin concentration below 7.0 g/dl. The usability study identified potential failure modes due to inadequate instructions and device feedback. With some modifications, both to the product and to the instructions for use, the TrueHb may be suitable for use in ANC settings to help fill the diagnostic gap for anemia screening during pregnancy. Further testing is required with anemic populations in LMIC settings.


Asunto(s)
Anemia/diagnóstico , Hemoglobinometría/instrumentación , Hemoglobinas/análisis , Complicaciones Hematológicas del Embarazo/diagnóstico , Adulto , Estudios Transversales , Femenino , Ghana , Voluntarios Sanos , Humanos , Tamizaje Masivo , Embarazo , Atención Prenatal , Prevalencia
4.
Int Health ; 11(1): 7-14, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30184203

RESUMEN

Glucose-6-phosphate dehyrdgoenase (G6PD) deficiency is a common X-linked genetic trait, with an associated enzyme phenotype, whereby males are either G6PD deficient or normal, but females exhibit a broader range of G6PD deficiencies, ranging from severe deficiency to normal. Heterozygous females typically have intermediate G6PD activity. G6PD deficiency has implications for the safe treatment for Plasmodium vivax malaria. Individuals with this deficiency are at greater risk of serious adverse events following treatment with the only curative class of anti-malarials, 8-aminoquinolines, such as primaquine. Quantitative diagnostic tests for G6PD deficiency are complex and require sophisticated laboratories. The commonly used qualitative tests, do not discriminate intermediate G6PD activities. This has resulted in poor understanding of the epidemiology of G6PD activity in females and its corresponding treatment ramifications. New simple-to-use quantitative tests, and a momentum to eliminate malaria, create an opportunity to address this knowledge gap. While this will require additional resources for clinical studies, adequate operational research, and appropriate pharmacovigilance, the health benefits from this investment go beyond the immediate intervention for which the G6PD status is first diagnosed.


Asunto(s)
Deficiencia de Glucosafosfato Deshidrogenasa , Conocimientos, Actitudes y Práctica en Salud , África , Aminoquinolinas/efectos adversos , Aminoquinolinas/uso terapéutico , Antimaláricos/efectos adversos , Antimaláricos/uso terapéutico , Femenino , Humanos , Malaria Vivax/tratamiento farmacológico , Masculino , Primaquina/efectos adversos , Primaquina/uso terapéutico , Factores de Riesgo , Factores Sexuales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA