Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Small ; : e2400673, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38700057

RESUMEN

Parasitic side reactions and dendrites formation hinder the application of aqueous zinc ion batteries due to inferior cycling life and low reversibility. Against this background, N-methyl formamide (NMF), a multi-function electrolyte additive is applied to enhance the electrochemical performance. Studied via advanced synchrotron radiation spectroscopy and DFT calculations, the NMF additive simultaneously modifies the Zn2+ solvation structure and ensures uniform zinc deposition, thus suppressing both parasitic side reactions and dendrite formation. More importantly, an ultralong cycling life of 3115 h in the Zn||Zn symmetric cell at a current density of 0.5 mA cm-2 is achieved with the NMF additive. Practically, the Zn||PANI full cell utilizing NMF electrolyte shows better rate and cycling performance compared to the pristine ZnSO4 aqueous electrolyte. This work provides useful insights for the development of high-performance aqueous metal batteries.

2.
Trauma Surg Acute Care Open ; 8(1): e001024, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37073334

RESUMEN

Objectives: Vasopressors are a cornerstone in the management of sepsis, marked by distributive shock often unresponsive to fluid resuscitation. Prior research and clinician surveys have suggested that earlier usage of vasopressors corresponds to improved outcomes. Methods: A retrospective cohort was constructed using patient data contained within the Medical Information Mart for Intensive Care-IV database. Analytic cohort included a total of 2079 patients meeting sepsis-3 criteria with a ≥2-point rise in Sequential Organ Failure Assessment score and administered norepinephrine (NE) as first-line vasopressor within 24 hours of admission to the intensive care unit (ICU). Patients receiving other vasopressors or missing documented fluid resuscitation information were excluded. Primary end points included mortality, use of invasive mechanical ventilation and length of stay which were analyzed in a multivariate logistic regression model for the primary effect of time from ICU admission to NE administration using covariates. Results: Time to NE use was defined as either early, using <6 hours from time of ICU admission or late using >6 hours to ≤24 hours. Patients who received early NE had significantly lower adjusted odds of mortality (0.75, 95% CI 0.57 to 0.97, p=0.026), higher adjusted odds of invasive mechanical ventilation (1.48, 95% CI 1.01 to 2.16, p=0.045), no significant difference in hospital length of stay (difference in days 0.6 (95% CI -3.24 to 2.04)) and lower ICU length of stay (difference in days -0.9 (95% CI -1.74 to -0.01)), as compared with the late NE group. Conclusion: Among patients admitted to the ICU for sepsis, early use of NE was associated with significantly lower odds of mortality but higher odds of mechanical ventilation, and no significant difference in length of hospital stay but less time in the ICU. Furthermore, the volume of fluids received prior to NE use may have a significant impact on optimal NE timing. Level of evidence: Level IV-therapeutic care/management.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA