Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Mult Scler ; 29(6): 702-718, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36550626

RESUMEN

BACKGROUND: Spinal cord (SC) gray and white matter pathology plays a central role in multiple sclerosis (MS). OBJECTIVE: We aimed to investigate the extent, pattern, and clinical relevance of SC gray and white matter atrophy in vivo. METHODS: 39 relapsing-remitting patients (RRMS), 40 progressive MS patients (PMS), and 24 healthy controls (HC) were imaged at 3T using the averaged magnetization inversion recovery acquisitions sequence. Total and lesional cervical gray and white matter, and posterior (SCPH) and anterior horn (SCAH) areas were automatically quantified. Clinical assessment included the expanded disability status scale, timed 25-foot walk test, nine-hole peg test, and the 12-item MS walking scale. RESULTS: PMS patients had significantly reduced cervical SCAH - but not SCPH - areas compared with HC and RRMS (both p < 0.001). In RRMS and PMS, the cervical SCAH areas increased significantly less in the region of cervical SC enlargement compared with HC (all p < 0.001). This reduction was more pronounced in PMS compared with RRMS (both p < 0.001). In PMS, a lower cervical SCAH area was the most important magnetic resonance imaging (MRI)-variable for higher disability scores. CONCLUSION: MS patients show clinically relevant cervical SCAH atrophy, which is more pronounced in PMS and at the level of cervical SC enlargement.


Asunto(s)
Médula Cervical , Esclerosis Múltiple Crónica Progresiva , Esclerosis Múltiple Recurrente-Remitente , Esclerosis Múltiple , Humanos , Médula Cervical/diagnóstico por imagen , Médula Cervical/patología , Esclerosis Múltiple/patología , Médula Espinal/diagnóstico por imagen , Médula Espinal/patología , Esclerosis Múltiple Crónica Progresiva/diagnóstico por imagen , Esclerosis Múltiple Crónica Progresiva/patología , Sustancia Gris/patología , Imagen por Resonancia Magnética , Atrofia/patología , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/patología
2.
Ann Intern Med ; 175(1): 101-113, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34807719

RESUMEN

BACKGROUND: The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin (hs-cTn)-based strategies for triage of patients with suspected acute myocardial infarction (AMI). PURPOSE: To evaluate the diagnostic accuracies of the ESC 0/1-hour, 0/2-hour, and 0/3-hour algorithms. DATA SOURCES: PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus from 1 January 2011 to 31 December 2020. (PROSPERO: CRD42020216479). STUDY SELECTION: Prospective studies that evaluated the ESC 0/1-hour, 0/2-hour, or 0/3-hour algorithms in adult patients presenting with suspected AMI. DATA EXTRACTION: The primary outcome was index AMI. Twenty unique cohorts were identified. Primary data were obtained from investigators of 16 cohorts and aggregate data were extracted from 4 cohorts. Two independent authors assessed each study for methodological quality. DATA SYNTHESIS: A total of 32 studies (20 cohorts) with 30 066 patients were analyzed. The 0/1-hour algorithm had a pooled sensitivity of 99.1% (95% CI, 98.5% to 99.5%) and negative predictive value (NPV) of 99.8% (CI, 99.6% to 99.9%) for ruling out AMI. The 0/2-hour algorithm had a pooled sensitivity of 98.6% (CI, 97.2% to 99.3%) and NPV of 99.6% (CI, 99.4% to 99.8%). The 0/3-hour algorithm had a pooled sensitivity of 93.7% (CI, 87.4% to 97.0%) and NPV of 98.7% (CI, 97.7% to 99.3%). Sensitivity of the 0/3-hour algorithm was attenuated in studies that did not use clinical criteria (GRACE score <140 and pain-free) compared with studies that used clinical criteria (90.2% [CI, 82.9 to 94.6] vs. 98.4% [CI, 88.6 to 99.8]). All 3 algorithms had similar specificities and positive predictive values for ruling in AMI, but heterogeneity across studies was substantial. Diagnostic performance was similar across the hs-cTnT (Elecsys; Roche), hs-cTnI (Architect; Abbott), and hs-cTnI (Centaur/Atellica; Siemens) assays. LIMITATION: Diagnostic accuracy, inclusion and exclusion criteria, and cardiac troponin sampling time varied among studies. CONCLUSION: The ESC 0/1-hour and 0/2-hour algorithms have higher sensitivities and NPVs than the 0/3-hour algorithm for index AMI. PRIMARY FUNDING SOURCE: National Taiwan University Hospital.


Asunto(s)
Algoritmos , Biomarcadores/sangre , Infarto del Miocardio/diagnóstico , Guías de Práctica Clínica como Asunto , Triaje/métodos , Troponina/sangre , Diagnóstico Diferencial , Europa (Continente) , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Riesgo , Sociedades Médicas , Factores de Tiempo
3.
Cerebellum ; 21(4): 632-646, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34417983

RESUMEN

Cerebellar symptoms in multiple sclerosis (MS) are well described; however, the exact contribution of cerebellar damage to MS disability has not been fully explored. Longer-term observational periods are necessary to better understand the dynamics of pathological changes within the cerebellum and their clinical consequences. Cerebellar lobe and single lobule volumes were automatically segmented on 664 3D-T1-weighted MPRAGE scans (acquired at a single 1.5 T scanner) of 163 MS patients (111 women; mean age: 47.1 years; 125 relapsing-remitting (RR) and 38 secondary progressive (SP) MS, median EDSS: 3.0) imaged annually over 4 years. Clinical scores (EDSS, 9HPT, 25FWT, PASAT, SDMT) were determined per patient per year with a maximum clinical follow-up of 11 years. Linear mixed-effect models were applied to assess the association between cerebellar volumes and clinical scores and whether cerebellar atrophy measures may predict future disability progression. SPMS patients exhibited faster posterior superior lobe volume loss over time compared to RRMS, which was related to increase of EDSS over time. In RRMS, cerebellar volumes were significant predictors of motor scores (e.g. average EDSS, T25FWT and 9HPT) and SDMT. Atrophy of motor-associated lobules (IV-VI + VIII) was a significant predictor of future deterioration of the 9HPT of the non-dominant hand. In SPMS, the atrophy rate of the posterior superior lobe (VI + Crus I) was a significant predictor of future PASAT performance deterioration. Regional cerebellar volume reduction is associated with motor and cognitive disability in MS and may serve as a predictor for future disease progression, especially of dexterity and impaired processing speed.


Asunto(s)
Esclerosis Múltiple Crónica Progresiva , Esclerosis Múltiple , Atrofia/patología , Cerebelo/diagnóstico por imagen , Cerebelo/patología , Evaluación de la Discapacidad , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Esclerosis Múltiple/patología , Esclerosis Múltiple Crónica Progresiva/diagnóstico por imagen , Esclerosis Múltiple Crónica Progresiva/patología
4.
Hum Brain Mapp ; 42(8): 2399-2415, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33624390

RESUMEN

There is evidence that multiple sclerosis (MS) pathology leads to distinct patterns of volume loss over time (VLOT) in different central nervous system (CNS) structures. We aimed to use such patterns to identify patient subgroups. MS patients of all classical disease phenotypes underwent annual clinical, blood, and MRI examinations over 6 years. Spinal, striatal, pallidal, thalamic, cortical, white matter, and T2-weighted lesion volumes as well as serum neurofilament light chain (sNfL) were quantified. CNS VLOT patterns were identified using principal component analysis and patients were classified using hierarchical cluster analysis. 225 MS patients were classified into four distinct Groups A, B, C, and D including 14, 59, 141, and 11 patients, respectively). These groups did not differ in baseline demographics, disease duration, disease phenotype distribution, and lesion-load expansion. Interestingly, Group A showed pronounced spinothalamic VLOT, Group B marked pallidal VLOT, Group C small between-structure VLOT differences, and Group D myelocortical volume increase and pronounced white matter VLOT. Neurologic deficits were more severe and progressed faster in Group A that also had higher mean sNfL levels than all other groups. Group B experienced more frequent relapses than Group C. In conclusion, there are distinct patterns of VLOT across the CNS in MS patients, which do not overlap with clinical MS subtypes and are independent of disease duration and lesion-load but are partially associated to sNfL levels, relapse rates, and clinical worsening. Our findings support the need for a more biologic classification of MS subtypes including volumetric and body-fluid markers.


Asunto(s)
Encéfalo , Progresión de la Enfermedad , Esclerosis Múltiple , Médula Espinal , Adulto , Anciano , Atrofia/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Estudios Longitudinales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/clasificación , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Neuroimagen , Médula Espinal/diagnóstico por imagen , Médula Espinal/patología , Adulto Joven
5.
Eur J Neurol ; 28(12): 4153-4166, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34487400

RESUMEN

BACKGROUND AND PURPOSE: In an era of individualized multiple sclerosis (MS) patient management, biomarkers for accurate prediction of future clinical outcomes are needed. We aimed to evaluate the potential of short-term magnetic resonance imaging (MRI) atrophy measures and serum neurofilament light chain (sNfL) as predictors of the dynamics of disability accumulation in relapse-onset MS. METHODS: Brain gray and white matter, thalamic, striatal, pallidal and cervical spinal cord volumes, and lesion load were measured over three available time points (mean time span 2.24 ± 0.70 years) for 183 patients (140 relapsing-remitting [RRMS] and 43 secondary-progressive MS (SPMS); 123 female, age 46.4 ± 11.0 years; disease duration 15.7 ± 9.3 years), and their respective annual changes were calculated. Baseline sNfL was also measured at the third available time point for each patient. Subsequently, patients underwent annual clinical examinations over 5.4 ± 3.7 years including Expanded Disability Status Scale (EDSS) scoring, the nine-hole peg test and the timed 25-foot walk test. RESULTS: Higher annual spinal cord atrophy rates and lesion load increase predicted higher future EDSS score worsening over time in SPMS. Lower baseline thalamic volumes predicted higher walking speed worsening over time in RRMS. Lower baseline gray matter, as well as higher white matter and spinal cord atrophy rates, lesion load increase, baseline striatal volumes and baseline sNfL, predicted higher future hand dexterity worsening over time. All models showed reasonable to high prediction accuracy. CONCLUSION: This study demonstrates the capability of short-term MRI metrics to accurately predict future dynamics of disability progression in a real-world relapse-onset MS cohort. The present study represents a step towards the utilization of structural MRI measurements in patient care.


Asunto(s)
Esclerosis Múltiple Crónica Progresiva , Esclerosis Múltiple Recurrente-Remitente , Esclerosis Múltiple , Adulto , Atrofia/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Evaluación de la Discapacidad , Progresión de la Enfermedad , Femenino , Sustancia Gris/patología , Humanos , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Esclerosis Múltiple Crónica Progresiva/diagnóstico por imagen , Esclerosis Múltiple Crónica Progresiva/patología , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/patología
6.
Hum Brain Mapp ; 41(8): 2198-2215, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32067281

RESUMEN

In multiple sclerosis (MS), cortical atrophy is correlated with clinical and neuropsychological measures. We aimed to examine the differences in the temporospatial evolution of cortical thickness (CTh) between MS-subtypes and to study the association of CTh with T2-weighted white matter lesions (T2LV) and clinical progression. Two hundred and forty-three MS patients (180 relapsing-remitting [RRMS], 51 secondary-progressive [SPMS], and 12 primary-progressive [PPMS]) underwent annual clinical (incl. expanded disability status scale [EDSS]) and MRI-examinations over 6 years. T2LV and CTh were measured. CTh did not differ between MS-subgroups. Higher total T2LV was associated with extended bilateral CTh-reduction on average, but did not correlate with CTh-changes over time. In RRMS, CTh- and EDSS-changes over time were negatively correlated in large bilateral prefrontal, frontal, parietal, temporal, and occipital areas. In SPMS, CTh was not associated with the EDSS. In PPMS, CTh- and EDSS-changes over time were correlated in small clusters predominantly in left parietal areas. Increase of brain lesion load does not lead to an immediate CTh-reduction. Although CTh did not differ between MS-subtypes, a dissociation in the correlation between CTh- and EDSS-changes over time between RRMS and progressive-MS was shown, possibly underlining the contribution of subcortical pathology to clinical progression in progressive-MS.


Asunto(s)
Corteza Cerebral/patología , Adelgazamiento de la Corteza Cerebral/patología , Progresión de la Enfermedad , Esclerosis Múltiple Crónica Progresiva/patología , Esclerosis Múltiple Recurrente-Remitente/patología , Sustancia Blanca/patología , Adulto , Corteza Cerebral/diagnóstico por imagen , Adelgazamiento de la Corteza Cerebral/diagnóstico por imagen , Femenino , Humanos , Estudios Longitudinales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Esclerosis Múltiple Crónica Progresiva/diagnóstico por imagen , Esclerosis Múltiple Crónica Progresiva/fisiopatología , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/fisiopatología , Índice de Severidad de la Enfermedad , Sustancia Blanca/diagnóstico por imagen
7.
Hum Brain Mapp ; 40(14): 4091-4104, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31206931

RESUMEN

Neurodegenerative disorders, such as Alzheimer's disease (AD) and progressive forms of multiple sclerosis (MS), can affect the brainstem and are associated with atrophy that can be visualized by MRI. Anatomically accurate, large-scale assessments of brainstem atrophy are challenging due to lack of automated, accurate segmentation methods. We present a novel method for brainstem volumetry using a fully-automated segmentation approach based on multi-dimensional gated recurrent units (MD-GRU), a deep learning based semantic segmentation approach employing a convolutional adaptation of gated recurrent units. The neural network was trained on 67 3D-high resolution T1-weighted MRI scans from MS patients and healthy controls (HC) and refined using segmentations of 20 independent MS patients' scans. Reproducibility was assessed in MR test-retest experiments in 33 HC. Accuracy and robustness were examined by Dice scores comparing MD-GRU to FreeSurfer and manual brainstem segmentations in independent MS and AD datasets. The mean %-change/SD between test-retest brainstem volumes were 0.45%/0.005 (MD-GRU), 0.95%/0.009 (FreeSurfer), 0.86%/0.007 (manually edited segmentations). Comparing MD-GRU to manually edited segmentations the mean Dice scores/SD were: 0.97/0.005 (brainstem), 0.95/0.013 (mesencephalon), 0.98/0.006 (pons), 0.95/0.015 (medulla oblongata). Compared to the manual gold standard, MD-GRU brainstem segmentations were more accurate than FreeSurfer segmentations (p < .001). In the multi-centric acquired AD data, the mean Dice score/SD for the MD-GRU-manual segmentation comparison was 0.97/0.006. The fully automated brainstem segmentation method MD-GRU provides accurate, highly reproducible, and robust segmentations in HC and patients with MS and AD in 200 s/scan on an Nvidia GeForce GTX 1080 GPU and shows potential for application in large and longitudinal datasets.


Asunto(s)
Tronco Encefálico/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Esclerosis Múltiple/diagnóstico por imagen , Enfermedades Neurodegenerativas/diagnóstico por imagen , Neuroimagen/métodos , Adulto , Anciano , Aprendizaje Profundo , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad
8.
Mult Scler ; 25(7): 947-957, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-29781383

RESUMEN

BACKGROUND: Little is known on longer term changes of spinal cord volume (SCV) in primary progressive multiple sclerosis (PPMS). OBJECTIVE: Longitudinal evaluation of SCV loss in PPMS and its correlation to clinical outcomes, compared to relapse-onset multiple sclerosis (MS) subtypes. METHODS: A total of 60 MS age-, sex- and disease duration-matched patients (12 PPMS, each 24 relapsing-remitting (RRMS) and secondary progressive MS (SPMS)) were analysed annually over 6 years of follow-up. The upper cervical SCV was measured on 3D T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE) images using a semi-automatic software (CORDIAL), along with the total brain volume (TBV), brain T2 lesion volume (T2LV) and Expanded Disability Status Scale (EDSS). RESULTS: PPMS showed faster SCV loss over time than RRMS ( p < 0.01) and by trend ( p = 0.066) compared with SPMS. In contrast to relapse-onset MS, in PPMS SCV loss progressed independent of TBV and T2LV changes. Moreover, in PPMS, SCV was the only magnetic resonance imaging (MRI) measurement associated with EDSS increase over time ( p < 0.01), as opposed to RRMS and SPMS. CONCLUSION: SCV loss is a strong predictor of clinical outcomes in PPMS and has shown to be faster and independent of brain MRI metrics compared to relapse-onset MS.


Asunto(s)
Progresión de la Enfermedad , Esclerosis Múltiple Crónica Progresiva/patología , Esclerosis Múltiple Recurrente-Remitente/patología , Médula Espinal/patología , Adulto , Anciano , Atrofia/patología , Biomarcadores , Femenino , Humanos , Estudios Longitudinales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Esclerosis Múltiple Crónica Progresiva/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Pronóstico , Médula Espinal/diagnóstico por imagen
9.
Mult Scler ; 25(3): 352-360, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-29327668

RESUMEN

BACKGROUND: Compared to 1.5 T, 3 T magnetic resonance imaging (MRI) increases signal-to-noise ratio leading to improved image quality. However, its clinical relevance in clinically isolated syndrome suggestive of multiple sclerosis remains uncertain. OBJECTIVES: The purpose of this study was to investigate how 3 T MRI affects the agreement between raters on lesion detection and diagnosis. METHODS: We selected 30 patients and 10 healthy controls from our ongoing prospective multicentre cohort. All subjects received baseline 1.5 and 3 T brain and spinal cord MRI. Patients also received follow-up brain MRI at 3-6 months. Four experienced neuroradiologists and four less-experienced raters scored the number of lesions per anatomical region and determined dissemination in space and time (McDonald 2010). RESULTS: In controls, the mean number of lesions per rater was 0.16 at 1.5 T and 0.38 at 3 T ( p = 0.005). For patients, this was 4.18 and 4.40, respectively ( p = 0.657). Inter-rater agreement on involvement per anatomical region and dissemination in space and time was moderate to good for both field strengths. 3 T slightly improved agreement between experienced raters, but slightly decreased agreement between less-experienced raters. CONCLUSION: Overall, the interobserver agreement was moderate to good. 3 T appears to improve the reading for experienced readers, underlining the benefit of additional training.


Asunto(s)
Competencia Clínica/normas , Enfermedades Desmielinizantes/diagnóstico por imagen , Enfermedades Desmielinizantes/patología , Imagen por Resonancia Magnética/normas , Neuroimagen/normas , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Neurólogos , Radiólogos
10.
Brain ; 141(8): 2382-2391, 2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-29860296

RESUMEN

Neuro-axonal injury is a key factor in the development of permanent disability in multiple sclerosis. Neurofilament light chain in peripheral blood has recently emerged as a biofluid marker reflecting neuro-axonal damage in this disease. We aimed at comparing serum neurofilament light chain levels in multiple sclerosis and healthy controls, to determine their association with measures of disease activity and their ability to predict future clinical worsening as well as brain and spinal cord volume loss. Neurofilament light chain was measured by single molecule array assay in 2183 serum samples collected as part of an ongoing cohort study from 259 patients with multiple sclerosis (189 relapsing and 70 progressive) and 259 healthy control subjects. Clinical assessment, serum sampling and MRI were done annually; median follow-up time was 6.5 years. Brain volumes were quantified by structural image evaluation using normalization of atrophy, and structural image evaluation using normalization of atrophy, cross-sectional, cervical spinal cord volumes using spinal cord image analyser (cordial). Results were analysed using ordinary linear regression models and generalized estimating equation modelling. Serum neurofilament light chain was higher in patients with a clinically isolated syndrome or relapsing remitting multiple sclerosis as well as in patients with secondary or primary progressive multiple sclerosis than in healthy controls (age adjusted P < 0.001 for both). Serum neurofilament light chain above the 90th percentile of healthy controls values was an independent predictor of Expanded Disability Status Scale worsening in the subsequent year (P < 0.001). The probability of Expanded Disability Status Scale worsening gradually increased by higher serum neurofilament light chain percentile category. Contrast enhancing and new/enlarging lesions were independently associated with increased serum neurofilament light chain (17.8% and 4.9% increase per lesion respectively; P < 0.001). The higher the serum neurofilament light chain percentile level, the more pronounced was future brain and cervical spinal volume loss: serum neurofilament light chain above the 97.5th percentile was associated with an additional average loss in brain volume of 1.5% (P < 0.001) and spinal cord volume of 2.5% over 5 years (P = 0.009). Serum neurofilament light chain correlated with concurrent and future clinical and MRI measures of disease activity and severity. High serum neurofilament light chain levels were associated with both brain and spinal cord volume loss. Neurofilament light chain levels are a real-time, easy to measure marker of neuro-axonal injury that is conceptually more comprehensive than brain MRI.


Asunto(s)
Esclerosis Múltiple/patología , Proteínas de Neurofilamentos/análisis , Adulto , Atrofia/patología , Biomarcadores/sangre , Encéfalo/patología , Médula Cervical/patología , Estudios de Cohortes , Estudios Transversales , Progresión de la Enfermedad , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Malformaciones del Sistema Nervioso/patología , Proteínas de Neurofilamentos/sangre , Imagen Individual de Molécula , Médula Espinal/patología
11.
J Neuroinflammation ; 15(1): 255, 2018 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-30185189

RESUMEN

BACKGROUND: We compared the magnetic resonance imaging (MRI) features between Japanese and Caucasian patients with multiple sclerosis (MS), and identified the relationships between MRI features and disability. METHODS: From the baseline data of phase II fingolimod trials, 95 Japanese and 246 Caucasian relapsing-remitting MS patients were enrolled. The number, volume, and distribution of brain MRI lesions were evaluated using T2-weighted (T2W) images. Cross-sectional total normalized brain volume (NBV), normalized cortical gray matter volume, normalized deep gray matter volume (NDGMV), normalized white matter volume (NWMV), and normalized thalamic volume were measured. RESULTS: Japanese patients had significantly lower Expanded Disability Status Scale (EDSS) scores than Caucasian patients (mean 2.0 vs. 2.3, p = 0.008), despite a similar disease duration. Japanese patients showed a trend towards fewer T2W-lesions (median 50 vs. 65, p = 0.08) and significantly lower frequencies of cerebellar and parietal lobe lesions (p = 0.02 for both) than Caucasian patients. There were no differences in T2W-lesion volume between races, whereas Japanese patients had a significantly larger T2W-lesion volume per lesion compared with Caucasian patients (median 140 mm3 vs. 85 mm3, p < 0.0001). T2W-lesion volumes were positively correlated with EDSS scores in Japanese patients (p < 0.0001). In both races, NBV, normalized cortical gray matter volume, NDGMV, and thalamic volume were negatively correlated with disease duration and EDSS scores (p < 0.01 for all). NWMV was negatively correlated with disease duration and EDSS scores only in Caucasian patients (p = 0.03 and p = 0.004, respectively). NBV, NDGMV, NWMV, and thalamic volume were consistently smaller in Japanese compared with Caucasian patients throughout the entire examined disease duration (p = 0.046, p = 0.01, p = 0.005, and p = 0.04, respectively). Japanese patients had a significantly faster reduction in NDGMV (p = 0.001), particularly for thalamic volume (p = 0.001), with disease duration compared with Caucasian patients. CONCLUSIONS: Gray matter atrophy is a common denominator for disability in Japanese and Caucasian patients. Additional contributory factors for disability include T2W-lesion volume in Japanese patients and white matter atrophy in Caucasian patients. Less frequent parietal and cerebellar involvement with fewer T2W-lesions may underlie milder disability in Japanese patients.


Asunto(s)
Encéfalo/diagnóstico por imagen , Personas con Discapacidad , Progresión de la Enfermedad , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple , Adulto , Estudios Transversales , Evaluación de la Discapacidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Japón , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/etnología , Esclerosis Múltiple/fisiopatología , Valores de Referencia , Índice de Severidad de la Enfermedad , Población Blanca
12.
Eur Radiol ; 28(11): 4488-4495, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29713776

RESUMEN

OBJECTIVE: To validate the precision and accuracy of the semi-automated cord image analyser (Cordial) for lumbar spinal cord (SC) volumetry in 3D T1w MRI data of healthy controls (HC). MATERIALS AND METHODS: 40 3D T1w images of 10 HC (w/m: 6/4; age range: 18-41 years) were acquired at one 3T-scanner in two MRI sessions (time interval 14.9±6.1 days). Each subject was scanned twice per session, allowing determination of test-retest reliability both in back-to-back (intra-session) and scan-rescan images (inter-session). Cordial was applied for lumbar cord segmentation twice per image by two raters, allowing for assessment of intra- and inter-rater reliability, and compared to a manual gold standard. RESULTS: While manually segmented volumes were larger (mean: 2028±245 mm3 vs. Cordial: 1636±300 mm3, p<0.001), accuracy assessments between manually and semi-automatically segmented images showed a mean Dice-coefficient of 0.88±0.05. Calculation of within-subject coefficients of variation (COV) demonstrated high intra-session (1.22-1.86%), inter-session (1.26-1.84%), as well as intra-rater (1.73-1.83%) reproducibility. No significant difference was shown between intra- and inter-session reproducibility or between intra-rater reliabilities. Although inter-rater reproducibility (COV: 2.87%) was slightly lower compared to all other reproducibility measures, between rater consistency was very strong (intraclass correlation coefficient: 0.974). CONCLUSION: While under-estimating the lumbar SCV, Cordial still provides excellent inter- and intra-session reproducibility showing high potential for application in longitudinal trials. KEY POINTS: • Lumbar spinal cord segmentation using the semi-automated cord image analyser (Cordial) is feasible. • Lumbar spinal cord is 40-mm cord segment 60 mm above conus medullaris. • Cordial provides excellent inter- and intra-session reproducibility in lumbar spinal cord region. • Cordial shows high potential for application in longitudinal trials.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Médula Espinal/diagnóstico por imagen , Adolescente , Adulto , Femenino , Voluntarios Sanos , Humanos , Vértebras Lumbares , Masculino , Reproducibilidad de los Resultados , Adulto Joven
13.
J Thromb Thrombolysis ; 45(3): 432-439, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29349545

RESUMEN

In patients at high risk for bleeding undergoing percutaneous coronary intervention (PCI) the use of bare-metal-stent (BMS) is considered an option that allows discontinuation of clopidogrel after 4 weeks. We sought to investigate the risk of early discontinuation of clopidogrel in patients with BMS as compared with a 6-month course of clopidogrel after DES in patients with or without high on-treatment platelet reactivity (HTPR). In 765 consecutive patients undergoing PCI after loading with clopidogrel 600 mg, HTPR was tested by optical aggregometry and defined as residual platelet reactivity > 14%. On top of aspirin 100 mg, patients received clopidogrel 75 mg for 4 weeks after BMS or 6 months after DES. The primary endpoint was all-cause mortality or myocardial infarction (MI) during 1 year. The 1-year incidence of death or MI was 3.5% with BMS (n = 484), 0.9% with DES and no HTPR (n = 211), and 7.1% with DES and HTPR (n = 70; p = 0.03). Landmark analyses for the first 6 months demonstrated that the risk of patients receiving BMS was similar as in patients receiving a DES with HTPR during this period (2.3 vs. 2.9%) but lowest in patients receiving a DES without HTPR (0.5%). The incidence of bleeding was similar in all three groups. These findings did not change after propensity score adjustment for stent type. After discontinuation of clopidogrel at 1 month, patients treated with BMS are at higher risk for death or MI than patients treated with a DES and sufficiently responding to clopidogrel planned for 6 months.ClinicalTrials.gov number NCT00457236.


Asunto(s)
Stents Liberadores de Fármacos , Stents , Ticlopidina/análogos & derivados , Anciano , Clopidogrel , Stents Liberadores de Fármacos/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mortalidad , Infarto del Miocardio , Inhibidores de Agregación Plaquetaria/uso terapéutico , Puntaje de Propensión , Stents/estadística & datos numéricos , Ticlopidina/administración & dosificación , Ticlopidina/uso terapéutico , Factores de Tiempo
14.
Eur Neurol ; 80(3-4): 207-214, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30605898

RESUMEN

BACKGROUND: Structural Image Evaluation using Normalization of Atrophy (SIENA) is used to measure brain atrophy in multiple sclerosis (MS). However, brain extraction is prone to artefacts in the upper and lower parts of the brain. To overcome these shortcomings, some pivotal MS trials used a central slab instead of the whole brain as input for SIENA. The aim of this study was to compare the internal consistency and statistical dispersion of atrophy measures, associations with clinical outcomes and required sample sizes in clinical trials between these two approaches. METHODS: Brain volume change was assessed using SIENA in 119 MS patients with 5-years follow-up on 3D T1-weighted Magnetization Prepared Rapid Gradient Echo datasets using the whole brain or a central slab ranging from -10 to +60 mm Montreal Neurological Institute atlas coordinates. The statistical analysis included the quartile coefficient of dispersion, partial correlations with clinical outcomes and sample size calculations. Clinical outcome measures comprised the Expanded Disability Status Scale, MS Functional Composite and Symbol Digit Modalities Test. RESULTS: Annualized brain atrophy rates were higher using central slab than whole brain as input for SIENA (-0.51 ± 0.49 vs. -0.37 ± 0.39% per year, p < 0.001). Central and whole brain volume change showed comparable statistical dispersion and similarly correlated with clinical outcomes at 5-years follow-up. Sample size calculations estimated 14% fewer patients required to detect a given treatment effect when using the central slab instead of the whole brain option in SIENA. CONCLUSION: Central slab and whole brain SIENA produced comparable statistical dispersion with similar associations to clinical outcomes.


Asunto(s)
Encéfalo/patología , Interpretación de Imagen Asistida por Computador/métodos , Esclerosis Múltiple/patología , Adulto , Atrofia/patología , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad
15.
Neuroimage ; 134: 281-294, 2016 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-27039700

RESUMEN

A concern for researchers planning multisite studies is that scanner and T1-weighted sequence-related biases on regional volumes could overshadow true effects, especially for studies with a heterogeneous set of scanners and sequences. Current approaches attempt to harmonize data by standardizing hardware, pulse sequences, and protocols, or by calibrating across sites using phantom-based corrections to ensure the same raw image intensities. We propose to avoid harmonization and phantom-based correction entirely. We hypothesized that the bias of estimated regional volumes is scaled between sites due to the contrast and gradient distortion differences between scanners and sequences. Given this assumption, we provide a new statistical framework and derive a power equation to define inclusion criteria for a set of sites based on the variability of their scaling factors. We estimated the scaling factors of 20 scanners with heterogeneous hardware and sequence parameters by scanning a single set of 12 subjects at sites across the United States and Europe. Regional volumes and their scaling factors were estimated for each site using Freesurfer's segmentation algorithm and ordinary least squares, respectively. The scaling factors were validated by comparing the theoretical and simulated power curves, performing a leave-one-out calibration of regional volumes, and evaluating the absolute agreement of all regional volumes between sites before and after calibration. Using our derived power equation, we were able to define the conditions under which harmonization is not necessary to achieve 80% power. This approach can inform choice of processing pipelines and outcome metrics for multisite studies based on scaling factor variability across sites, enabling collaboration between clinical and research institutions.


Asunto(s)
Artefactos , Encéfalo/anatomía & histología , Interpretación de Imagen Asistida por Computador/instrumentación , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Modelos Estadísticos , Algoritmos , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Europa (Continente) , Humanos , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos
16.
Platelets ; 27(7): 668-672, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27065056

RESUMEN

Testing of P2Y12-receptor antagonist effects can support clinical decision-making. However, most platelet function assays use only ADP as agonist which is not P2Y12-receptor specific. For this reason P2Y12-receptor specific assays have been developed by adding prostaglandin E1 (PGE1) to reduce ADP-induced platelet activation via the P2Y1-receptor. The present study sought to evaluate a P2Y12-receptor specific assay for determination of pharmacodynamic and clinical outcomes. This study enrolled 400 patients undergoing coronary stenting after loading with clopidogrel or prasugrel. ADP-induced platelet reactivity was assessed by whole blood aggregometry at multiple time points with a standard ADP assay (ADPtest) and a P2Y12-receptor specific assay (ADPtest HS, both run on Multiplate Analyzer, Roche Diagnostics). Patients were clinically followed for 1 month and all events adjudicated by an independent committee. In total, 2084 pairs of test results of ADPtest and ADPtest HS were available showing a strong correlation between results of both assays (r = 0.96, p < 0.001). These findings prevailed in multiple prespecified subgroups (e.g., age; body mass index; diabetes). Calculated cutoffs for ADPtest HS and the established cutoffs of ADPtest showed a substantial agreement for prediction of ischemic and hemorrhagic events with a Cohen's κ of 0.66 and 0.66, respectively. The P2Y12-receptor specific ADPtest HS assay appears similarly predictive for pharmacodynamic and clinical outcomes as compared to the established ADPtest assay indicating its applicability for clinical use. Further evaluation in large cohorts is needed to determine if P2Y12-receptor specific testing offers any advantage for prediction of clinical outcome.


Asunto(s)
Plaquetas/metabolismo , Agregación Plaquetaria , Pruebas de Función Plaquetaria , Receptores Purinérgicos P2Y12/metabolismo , Anciano , Plaquetas/efectos de los fármacos , Comorbilidad , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Agregación Plaquetaria/efectos de los fármacos , Inhibidores de Agregación Plaquetaria/farmacología , Pruebas de Función Plaquetaria/métodos , Pruebas de Función Plaquetaria/normas , Antagonistas del Receptor Purinérgico P2Y/farmacología , Reproducibilidad de los Resultados , Factores de Riesgo
17.
Int J Mol Sci ; 17(4): 489, 2016 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-27043553

RESUMEN

We performed voxel-guided morphometry (VGM) investigating the mechanisms of brain atrophy in multiple sclerosis (MS) related to focal lesions. VGM maps detect regional brain changes when comparing 2 time points on high resolution T1-weighted (T1w) magnetic resonace imaging (MRI). Two T1w MR datasets from 92 relapsing-remitting MS patients obtained 12 months apart were analysed with VGM. New lesions and volume changes of focal MS lesions as well as in the surrounding tissue were identified by visual inspection on colour coded VGM maps. Lesions were dichotomized in active and inactive lesions. Active lesions, defined by either new lesions (NL) (volume increase > 5% in VGM), chronic enlarging lesions (CEL) (pre-existent T1w lesions with volume increase > 5%), or chronic shrinking lesions (CSL) (pre-existent T1w lesions with volume reduction > 5%) in VGM, were accompanied by tissue shrinkage in surrounding and/or functionally related regions. Volume loss within the corpus callosum was highly correlated with the number of lesions in its close proximity. Volume loss in the lateral geniculate nucleus was correlated with lesions along the optic radiation. VGM analysis provides strong evidence that all active lesion types (NL, CEL, and CSL) contribute to brain volume reduction in the vicinity of lesions and/or in anatomically and functionally related areas of the brain.


Asunto(s)
Encéfalo/patología , Esclerosis Múltiple/patología , Adulto , Anciano , Atrofia/patología , Cuerpo Calloso/patología , Femenino , Cuerpos Geniculados/patología , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Logísticos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/diagnóstico por imagen
18.
Neuroimage ; 108: 87-94, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25536494

RESUMEN

Different pathological processes like demyelination and axonal loss can alter the magnetisation transfer ratio (MTR) in brain tissue. The standard method to measure this effect is to scan the respective tissue twice, one with and one without a specific saturation pulse. A major drawback of this technique based on spoiled gradient echo (GRE) sequences relates to its long acquisition time due to the saturation pulses. Recently, an alternative concept for MT imaging based on balanced steady state free precession (bSSFP) has been proposed. Modification of the duration of the radiofrequency pulses for imaging allows scanning MT sensitive and non-sensitive images. The steady-state character of bSSFP with high intrinsic signal-to-noise ratio (SNR) allows three-dimensional (3D) whole brain MTR at high spatial resolution within short and thus clinically feasible acquisition times. In the present study, both bSSFP-MT and 2D GRE-MT imaging were used in a cohort of 31 patients with multiple sclerosis (MS) to characterize different normal appearing (NA) and pathological brain structures. Under the constraint of identical SNR and scan time, a 3.4 times higher voxel size could be achieved with bSSFP. This increased resolution allowed a more accurate delineation of the different brain structures, especially of cortex, hippocampus and MS lesions. In a multiple linear regression model, we found an association between MTR of cortical lesions and a clinical measure of disability (r= -0.407, p=0.035) in the bSSFP dataset only. The different relaxation weighting of the base images (T2/T1 in bSSFP, proton density in GRE) had no effects besides a larger spreading of the MTR values of the different NA structures. This was demonstrated by the nearly perfect linearity between the NA matter MTR of both techniques as well as in the absolute MTR differences between NA matter and the respective lesions.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple Recurrente-Remitente/patología , Neuroimagen/métodos , Adulto , Anciano , Encéfalo/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad
19.
Hum Brain Mapp ; 35(8): 4193-203, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24510715

RESUMEN

Deep gray matter (DGM) atrophy has been reported in patients with multiple sclerosis (MS) already at early stages of the disease and progresses throughout the disease course. We studied DGM volume and shape and their relation to disability in a large cohort of clinically well-described MS patients using new subcortical segmentation methods and shape analysis. Structural 3D magnetic resonance images were acquired at 1.5 T in 118 patients with relapsing remitting MS. Subcortical structures were segmented using a multiatlas technique that relies on the generation of an automatically generated template library. To localize focal morphological changes, shape analysis was performed by estimating the vertex-wise displacements each subject must undergo to deform to a template. Multiple linear regression analysis showed that the volume of specific thalamic nuclei (the ventral nuclear complex) together with normalized gray matter volume explains a relatively large proportion of expanded disability status scale (EDSS) variability. The deformation-based displacement analysis confirmed the relation between thalamic shape and EDSS scores. Furthermore, white matter lesion volume was found to relate to the shape of all subcortical structures. This novel method for the analysis of subcortical volume and shape allows depicting specific contributions of DGM abnormalities to neurological deficits in MS patients. The results stress the importance of ventral thalamic nuclei in this respect.


Asunto(s)
Encéfalo/patología , Sustancia Gris/patología , Esclerosis Múltiple Recurrente-Remitente/patología , Adulto , Anciano , Atlas como Asunto , Estudios Transversales , Evaluación de la Discapacidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Modelos Lineales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Estudios Retrospectivos , Núcleos Talámicos/patología , Sustancia Blanca/patología , Adulto Joven
20.
Mult Scler ; 20(3): 356-64, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23959709

RESUMEN

OBJECTIVE: The objective of this paper is to investigate the relationship between total and regional corpus callosum (CC) atrophy, neuropsychological test performance and fatigue in multiple sclerosis (MS) patients. METHODS: We conducted a cross-sectional study in 113 MS patients: mean age 48 ± 11 years, 75/113 women, 84/113 relapsing-remitting MS, mean disease duration 21 ± 9 years, mean Expanded Disability Status Scale (EDSS) score 3.2 ± 1.7. All patients underwent brain magnetic resonance imaging, standardised neurological assessment and comprehensive cognitive testing including assessments for fatigue and depression. Total and regional CC atrophy was assessed using the corpus callosum index (CCI). RESULTS: CCI correlated more strongly with T2- and T1-lesion volume and whole brain volume than with disease duration or EDSS score. CCI correlated strongly with the verbal fluency test (VFT), Symbol Digit Modalities Test (SDMT) and Paced Auditory Serial Addition Test (PASAT). Multivariate regression analysis revealed that atrophy of the posterior CC segment was significantly associated with poor outcome in the PASAT, VFT and SDMT. In contrast, atrophy of the anterior CC segment was significantly associated with fatigue severity and poor outcome in the long-term memory test. CONCLUSIONS: Atrophy of the CC is associated with cognitive impairment and fatigue. Regional CCI results indicate that these associations are partially spatially segregated.


Asunto(s)
Trastornos del Conocimiento/patología , Cuerpo Calloso/patología , Fatiga/patología , Esclerosis Múltiple/patología , Adulto , Atrofia/patología , Trastornos del Conocimiento/complicaciones , Estudios Transversales , Fatiga/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA