Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 87(1): E39-43, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26033157

RESUMEN

OBJECTIVE: To explore the variations of brain natriuretic peptide (BNP) secretion after left atrial appendage occlusion. BACKGROUND: Left atrial appendage occlusion has been increasingly performed in the last few years, however little is known about the physiological consequences of left atrial appendage occlusion. Left atrial appendage regulates partially intravascular volume via release of brain natriuretic peptide. Brain natriuretic peptide levels have been related to increased risk of stroke in atrial fibrillation patients. METHODS: Venous blood samples were obtained in consecutive patients undergoing left atrial appendage occlusion before, 24 hr after device implantation and at the first visit after discharge (45-60 days) for BNP measurement. RESULTS: Left atrial appendage occlusion was performed in 34 patients with non-valvular atrial fibrillation and contraindication to long-term oral anticoagulation or at high-risk of bleeding. There were no differences in BNP levels between baseline and 24 hr after device implantation. However left atrial appendage closure resulted in a significant decrease in BNP levels at the first follow-up visit (45-60 days) compared to baseline measurements (759.90 pg ml(-1) vs. 636.90 pg ml(-1) , P = 0.013). CONCLUSIONS: Left atrial appendage occlusion modifies BNP levels. These levels decrease after left atrial appendage occlusion. The clinical consequences of these findings need to be evaluated in further studies. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Péptido Natriurético Encefálico/sangre , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/sangre , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Estudios Prospectivos , Factores de Riesgo , España/epidemiología , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Tasa de Supervivencia/tendencias
2.
Circ J ; 80(3): 738-44, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26823141

RESUMEN

BACKGROUND: Mitral paravalvular leak (PVL) is a potential complication of surgical valve replacement procedures. Real-time 3D transesophageal echocardiography (RT-3DTEE) has emerged as an efficient tool for providing essential information about the anatomy of mitral PVLs compared with 2DTEE findings. The purpose of this study was to evaluate the utility of RT-3DTEE in the assessment of mitral PVLs. METHODS AND RESULTS: The 3D characteristics of PVLs were recorded and compared with 2D findings. We included 34 consecutive patients with clinical suspicion of mitral PVL in the study. Mitral PVLs were detected in 26 patients (76%); 26 PVLs were identified by 2DTEE and 37 by RT-3DTEE. Moderate or severe mitral regurgitation was present in 23 patients (88%). The most common PVL locations were the septal and posterior regions. The median PVL size measured by RT-3DTEE was 7 mm long×4 mm wide. The median vena contracta of defect measured by 2DTEE and RT-3DTEE was 5 mm and 4 mm, respectively. The median effective regurgitant orifice area of defect measured by RT-3DTEE was 0.36 cm(2). The defect types were "oval" (54%), "round" (35%), "crescentic" (8%) and highly irregular (3%). CONCLUSIONS: Compared with 2DTEE, RT-3DTEE provided detailed descriptions of the number, location, size and morphology of PVLs, which is essential for planning and guiding the potential corrective techniques. (Circ J 2016; 80: 738-744).


Asunto(s)
Ecocardiografía Transesofágica/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/terapia
3.
Rev Esp Cardiol (Engl Ed) ; 72(5): 392-397, 2019 May.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29997054

RESUMEN

INTRODUCTION AND OBJECTIVES: Current therapeutic options for severe aortic stenosis (AS) include transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). Our aim was to describe the prognosis of patients with severe AS after the decision to perform an intervention, to study the variables influencing their prognosis, and to describe the determinants of waiting time > 2 months. METHODS: Subanalysis of the IDEAS (Influence of the Severe Aortic Stenosis Diagnosis) registry in patients indicated for TAVI or SAVR. RESULTS: Of 726 patients with severe AS diagnosed in January 2014, the decision to perform an intervention was made in 300, who were included in the present study. The mean age was 74.0 ± 9.7 years. A total of 258 (86.0%) underwent an intervention: 59 TAVI and 199 SAVR. At the end of the year, 42 patients (14.0%) with an indication for an intervention did not receive it, either because they remained on the waiting list (34 patients) or died while waiting for the procedure (8 patients). Of the patients who died while on the waiting list, half did so in the first 100 days. The mean waiting time was 2.9 ± 1.6 for TAVI and 3.5 ± 0.2 months for SAVR (P = .03). The independent predictors of mortality were male sex (HR, 2.6; 95%CI, 1.1-6.0), moderate-severe mitral regurgitation (HR, 2.6; 95%CI, 1.5-4.5), reduced mobility (HR, 4.6; 95%CI, 1.7-12.6), and nonintervention (HR, 2.3; 95%CI, 1.02-5.03). CONCLUSIONS: Patients with severe aortic stenosis awaiting therapeutic procedures have a high mortality risk. Some clinical indicators predict a worse prognosis and suggest the need for early intervention.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Toma de Decisiones Clínicas , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/mortalidad , Pronóstico , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Factores Sexuales , España/epidemiología , Análisis de Supervivencia , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Listas de Espera
4.
Rev Port Cardiol ; 34(2): 141.e1-3, 2015 Feb.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-25660462

RESUMEN

A 78-year-old woman was admitted to our institution with progressive dyspnea. She had previously been diagnosed with rheumatic heart disease and had undergone cardiac surgery for mechanical mitral valve replacement ten years previously. Transesophageal echocardiography revealed blockage of the mechanical prosthesis and the patient was scheduled for surgery, in which a thrombus was removed from the left atrial appendage. A partial thrombosis of the mechanical prosthesis and circumferential pannus overgrowth were concomitantly detected. Prosthetic heart valve blockage is a rare but life-threatening complication, the main causes of which are thrombosis and pannus formation. The two conditions are different but both are usually misdiagnosed. Two concurrent mechanisms of prosthesis blockage were found in this patient.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Mitral/patología , Trombosis/etiología , Anciano , Femenino , Fibrosis/etiología , Humanos , Falla de Prótesis
5.
Int J Cardiol ; 189: 61-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25885873

RESUMEN

BACKGROUND: The benefit from intervention in elderly patients with symptomatic severe aortic stenosis (AS) and high comorbidity is unknown. Our aims were to establish the correlation between the Charlson comorbidity index and the prognosis of octogenarians with symptomatic sever AS and to identify patients who might not benefit from intervention. METHODS: We used the data from PEGASO (Pronóstico de la Estenosis Grave Aórtica Sintomática del Octogenario--Prognosis of symptomatic severe aortic stenosis in octogenarians), a prospective registry that included consecutively 928 patients aged ≥ 80 years with severe symptomatic AS. RESULTS: The mean Charlson comorbidity index was 3.0 ± 1.7, a total of 151 patients (16.3%) presented high comorbidity (index ≥ 5). Median survival was lower for patients with high comorbidity than for those without (16.7 ± 1.2 vs. 26.5 ± 0.6 months, p < 0.001). In patients without high comorbidity planned interventional management was clearly associated with prognosis (log rank p < 0.001), which was not the case in patients with high comorbidity (log rank p > 0.10). In multivariate analysis, the only variables that were independently associated with prognosis were planned medical management and Charlson index. Patients with high comorbidity presented non-cardiac death more frequently than those who had not (28.6% vs. 19.5%, p = 0.008). CONCLUSIONS: One sixth of octogenarians with symptomatic severe AS have very high comorbidity (Charlson index ≥ 5). These patients have a poor prognosis in the short term and do not seem to benefit from interventional treatment.


Asunto(s)
Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Comorbilidad , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Análisis de Varianza , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Evaluación Geriátrica , Humanos , Masculino , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Estadísticas no Paramétricas , Tasa de Supervivencia , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
6.
Rev Port Cardiol ; 33(11): 739.e1-3, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25455950

RESUMEN

The most common etiology of tricuspid stenosis is rheumatic, and in most cases it is associated with valvular regurgitation. Interestingly, there have been reports of tricuspid stenosis without associated valvular regurgitation, mostly related to pacemaker leads. Percutaneous tricuspid valvuloplasty may be a therapeutic alternative to surgery in cases of pure tricuspid stenosis without other concomitant valvulopathies. We report the case of a 52-year-old woman with pacemaker lead-related tricuspid stenosis successfully treated with percutaneous valvuloplasty guided by 3D echocardiography.


Asunto(s)
Ecocardiografía Tridimensional , Marcapaso Artificial/efectos adversos , Cirugía Asistida por Computador , Estenosis de la Válvula Tricúspide/etiología , Estenosis de la Válvula Tricúspide/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Humanos , Persona de Mediana Edad , Inducción de Remisión , Estenosis de la Válvula Tricúspide/diagnóstico por imagen
7.
Rev Esp Cardiol (Engl Ed) ; 67(8): 608-14, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25037539

RESUMEN

INTRODUCTION AND OBJECTIVES: Percutaneous paravalvular leak closure is a complex procedure with varying success rates; the lack of closure devices specifically designed for this purpose has hampered this technique. The characteristics of the Amplatzer Vascular Plug III appear to be well suited for paravalvular leak closures; however, the available data are limited to case reports or small series of patients. The aim of this study was to analyze the feasibility and efficacy of paravalvular leak with this device. METHODS: The immediate and 90-day safety and efficacy of mitral and aortic paravalvular leak closures performed with this device at our hospital were analyzed. RESULTS: Percutaneous repair of 34 paravalvular leaks (27 mitral, 7 aortic) was attempted in 33 patients. The device was successfully implanted in 93.9% (in 2 patients, a second planned procedure was needed), and successful closure (defined as regurgitation reduction ≥ 1 grade) was achieved in 90.9% of patients. Complications included emergency surgery due to disc interference (n=1) and blood transfusion (n=3). There were no reports of procedure-related death, myocardial infarction, or stroke. At 90 days, survival was 100%, and 90.3% of patients showed significant clinical improvement; 4 patients developed vascular complications (pseudoaneurysm). CONCLUSIONS: Mitral and aortic paravalvular leak closure with the Amplatzer Vascular Plug III is feasible and safe, with high clinical and echocardiographic success rates.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Prótesis Valvulares Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Dispositivo Oclusor Septal , Anciano , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica/métodos , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Falla de Prótesis , Reoperación , Resultado del Tratamiento
8.
Rev. esp. cardiol. (Ed. impr.) ; 72(5): 392-397, mayo 2019. tab, graf
Artículo en Español | IBECS (España) | ID: ibc-188386

RESUMEN

Introducción y objetivos: Los tratamientos actuales de la estenosis aórtica (EAo) grave incluyen el implante percutáneo de válvula aórtica (TAVI) y la cirugía de sustitución valvular aórtica (SVAo). El objetivo es describir la evolución de los pacientes con EAo grave tras la indicación de intervención, las variables que influyen en su pronóstico y los determinantes de un tiempo de espera superior a 2 meses. Métodos: Subanálisis del registro IDEAS (Influencia del Diagnóstico de Estenosis Aórtica Severa) en los pacientes a los que se indicó intervención. Resultados: De 726 pacientes con EAo grave diagnosticada en enero de 2014, se indicó intervención a 300 que son el foco del presente estudio. La media de edad era 74,0 +/- 9,7 años. Se intervino a 258 pacientes (86,0%): 59 con TAVI y 199 con SVAo. Al año, 42 (14,0%) continuaban sin intervención, ya sea por seguir en espera (34) o haber fallecido (8). La mitad de los pacientes que murieron antes del procedimiento fallecieron en los primeros 100 días. El tiempo hasta la intervención fue 2,9 +/- 1,6 meses para el TAVI y 3,5 +/- 0,2 meses para la SVAo (p = 0,03). Los predictores de mortalidad independientes fueron el sexo masculino (HR = 2,6; IC95%, 1,1-6,0), la insuficiencia mitral moderada-grave (HR = 2,6; IC95%, 1,5-4,5), la movilidad reducida (HR = 4,6; IC95%, 1,7-12,6) y la falta de intervención (HR = 2,3; IC95%, 1,02-5,03). Conclusiones: Los pacientes con EAo grave en espera de intervención tienen alto riesgo de mortalidad. Hay indicadores clínicos asociados con peor pronóstico que podrían indicar la necesidad de una intervención precoz


Introduction and objectives: Current therapeutic options for severe aortic stenosis (AS) include transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). Our aim was to describe the prognosis of patients with severe AS after the decision to perform an intervention, to study the variables influencing their prognosis, and to describe the determinants of waiting time > 2 months. Methods: Subanalysis of the IDEAS (Influence of the Severe Aortic Stenosis Diagnosis) registry in patients indicated for TAVI or SAVR. Results: Of 726 patients with severe AS diagnosed in January 2014, the decision to perform an intervention was made in 300, who were included in the present study. The mean age was 74.0 +/- 9.7 years. A total of 258 (86.0%) underwent an intervention: 59 TAVI and 199 SAVR. At the end of the year, 42 patients (14.0%) with an indication for an intervention did not receive it, either because they remained on the waiting list (34 patients) or died while waiting for the procedure (8 patients). Of the patients who died while on the waiting list, half did so in the first 100 days. The mean waiting time was 2.9 +/- 1.6 for TAVI and 3.5 +/- 0.2 months for SAVR (P = .03). The independent predictors of mortality were male sex (HR, 2.6; 95%CI, 1.1-6.0), moderate-severe mitral regurgitation (HR, 2.6; 95%CI, 1.5-4.5), reduced mobility (HR, 4.6; 95%CI, 1.7-12.6), and non intervention (HR, 2.3; 95%CI, 1.02-5.03). Conclusions: Patients with severe aortic stenosis a waiting therapeutic procedures have a high mortality risk. Some clinical indicators predict a worse prognosis and suggest the need for early intervention


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Progresión de la Enfermedad , Listas de Espera , Indicadores de Morbimortalidad , Enfermedad Catastrófica , Estudios Prospectivos , Índice de Severidad de la Enfermedad
9.
Can J Cardiol ; 29(11): 1531.e15-6, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24054923

RESUMEN

Mechanical aortic valve prostheses are considered a limiting factor when contemplating percutaneous closure of mitral paravalvular leaks using a retrograde approach. However, transfemoral artery access and a retrograde approach have advantages over a trans-septal anterograde approach when the paravalvular defect is large with a significant gradient or when the defect is medial to the mitral valve. We describe a novel technique of mitral paravalvular leak closure in the presence of a mechanical aortic valve prosthesis, which we performed successfully in 3 patients. The technique uses a retrograde approach and arteriovenous wire loop.


Asunto(s)
Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Dispositivo Oclusor Septal , Anciano , Válvula Aórtica/cirugía , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Persona de Mediana Edad
10.
Can J Cardiol ; 29(11): 1532.e5-7, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24182760

RESUMEN

We report on a 77-year-old woman in whom percutaneous left atrial appendage (LAA) closure was performed. The patient had a left atrial myxoma resection 3 years previously, and 2 years later, she suffered a transient ischemic attack. Atrial fibrillation was detected and anticoagulation therapy was established. An episode of intracranial bleeding forced interruption of anticoagulation. Thus, percutaneous LAA closure with an Amplatzer Amulet LAA Occluder (St Jude Medical) was proposed. During the procedure, the LAA occluder migrated and became trapped in the mitral valve. Secondary massive mitral regurgitation and hemodynamic instability forced emergent cardiac surgery. Successful removal of the Amplatzer Amulet LAA Occluder was achieved.


Asunto(s)
Migración de Cuerpo Extraño/complicaciones , Migración de Cuerpo Extraño/cirugía , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/cirugía , Dispositivo Oclusor Septal/efectos adversos , Anciano , Apéndice Atrial/cirugía , Puente Cardiopulmonar , Femenino , Humanos , Insuficiencia de la Válvula Mitral/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA