Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 411
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38595080

RESUMEN

OBJECTIVES: This study assessed whether patient-specific contrast enhancement optimizer simulation software (p-COP) can reduce the contrast material (CM) dose compared with the conventional body weight (BW)-tailored scan protocol during transcatheter aortic valve implantation-computed tomography angiography (TAVI-CTA) in patients with aortic stenosis. METHODS: We used the CM injection protocol selected by the p-COP in group A (n = 30). p-COP uses an algorithm that concerns data on an individual patient's cardiac output. Group B (n = 30) was assigned to the conventional BW-tailored CM injection protocol group. We compared the CM dose, CM amount, injection rate, and computed tomography (CT) values in the abdominal aorta between the 2 groups and classified them as acceptable (>280 Hounsfield units (HU)) or unacceptable (<279 HU) based on the optimal CT value and visualization scores for TAVI-CTA. We used the Mann-Whitney U test to compare patient characteristics and assess the interpatient variability of subjects in both groups. RESULTS: Group A received 56.2 mL CM and 2.6 mL/s of injection, whereas group B received 76.9 mL CM and 3.4 mL/s of injection (P < 0.01). The CT value for the abdominal aorta at the celiac level was 287.0 HU in group A and 301.7HU in group B (P = 0.46). The acceptable (>280 HU) and unacceptable (<280 HU) CT value rates were 22 and 8 patients in group A and 24 and 6 patients in group B, respectively (P = 0.76). We observed no significant differences in the visualization scores between groups A and B (visualization score = 3, P = 0.71). CONCLUSION: The utilization of p-COP may decrease the CM dosage and injection rate by approximately 30% in individuals with aortic stenosis compared with the body-weight-tailored scan protocol during TAVI-CTA.

2.
Pediatr Radiol ; 54(5): 758-763, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38308740

RESUMEN

BACKGROUND: Adaptive collimation reduces the dose deposited outside the imaged volume along the z-axis. An increase in the dose deposited outside the imaged volume (to the lens and thyroid) in the z-axis direction is a concern in paediatric computed tomography (CT). OBJECTIVE: To compare the dose deposited outside the imaged volume (to the lens and thyroid) between 40-mm and 80-mm collimation during thoracic paediatric helical CT. MATERIALS AND METHODS: We used anthropomorphic phantoms of newborns and 5-year-olds with 40-mm and 80-mm collimation during helical CT. We compared the measured dose deposited outside the imaged volume using optically stimulated luminescence dosimeters (OSLD) at the surfaces of the lens and thyroid and the image noise between the 40-mm and 80-mm collimations. RESULTS: There were significant differences in the dose deposited outside the imaged volume (to the lens and thyroid) between the 40-mm and 80-mm collimations for both phantoms (P < 0.01). CONCLUSION: Compared with that observed for 80-mm collimation in helical CT scans of the paediatric thorax, the dose deposited outside the imaged volume (to the lens and thyroid) was significantly lower in newborns and 5-year-olds with 40-mm collimation.


Asunto(s)
Cristalino , Fantasmas de Imagen , Dosis de Radiación , Radiografía Torácica , Glándula Tiroides , Humanos , Glándula Tiroides/diagnóstico por imagen , Recién Nacido , Cristalino/diagnóstico por imagen , Cristalino/efectos de la radiación , Radiografía Torácica/métodos , Radiografía Torácica/instrumentación , Preescolar , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada Espiral/métodos
3.
Pediatr Radiol ; 54(7): 1197-1204, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38769141

RESUMEN

BACKGROUND: Reports comparing field lens doses between helical scans with a 40-mm detector width and axial scans with a 160-mm detector width using different computed tomography (CT) scanners are currently scarce. OBJECTIVE: To compare scatter doses for lenses between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width when using different CT scanners in the context of pediatric chest examinations. MATERIALS AND METHODS: Two different CT machines were used: Revolution CT (GE Healthcare, Waukesha, WI) with a 256-row, 0.625-mm multidetector; and Aquilion ONE GENESIS Edition (Canon Medical Systems, Otawara, Japan) with a 320-row, 0.5-mm multidetector. Three pediatric anthropomorphic phantoms were used, with optically stimulated luminescence dosimeters (OSLDs) placed on the left and right lenses. The scatter dose values measured by the OSLDs were compared between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width during pediatric chest CT examinations. RESULTS: Median equivalent doses for the helical and axial scans were 0.12 and 0.12 mSv/mGy for the newborn, 0.17 and 0.16 mSv/mGy for the 1-year-old, and 0.18 and 0.15 mSv/mGy for the 5-year-old, respectively, when using the Revolution CT. With the Revolution CT, no significant differences were observed in the scatter doses between helical and axial scans in the newborn and 1-year-old phantoms. However, the lens scatter dose for the helical scan was approximately 20-35% higher than that for the axial scan in the 5-year-old phantom (P<0.01). The median equivalent doses of eye lenses for the helical and axial scans were 0.12 and 0.07 mSv/mGy for the newborn, 0.07 and 0.05 mSv/mGy for the 1-year-old, and 0.14 and 0.12 mSv/mGy for the 5-year-old, respectively, when using the Aquilion ONE. With the Aquilion ONE, lens scatter doses for the helical scan were approximately 70%, 40%, and 30% higher in the newborn, 1-year-old, and 5-year-old phantoms, respectively, than those for the axial scan (P<0.01). CONCLUSIONS: When using the Aquilion ONE, lens scatter doses for the helical scan were significantly higher in all three phantoms than those for the axial scan. In contrast, when using the Revolution CT, the lens scatter dose for the helical scan was significantly higher in the 5-year-old phantom than that for the axial scan. These results suggest that although scattered doses may vary with respect to the CT scanner and body size, they are generally lower in the case of axial scans.


Asunto(s)
Cristalino , Fantasmas de Imagen , Dosis de Radiación , Dispersión de Radiación , Humanos , Cristalino/diagnóstico por imagen , Cristalino/efectos de la radiación , Tomografía Computarizada Espiral/métodos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/instrumentación , Diseño de Equipo , Radiometría/métodos , Niño , Exposición a la Radiación/análisis , Lactante , Recién Nacido
4.
Minim Invasive Ther Allied Technol ; 33(1): 35-42, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37909461

RESUMEN

INTRODUCTION: The purpose of this study was to determine the effect of proximal splenic artery embolization (SAE) in cirrhotic patients with splenomegaly who underwent surgical laparotomy. MATERIAL AND METHODS: This retrospective observational study included 8 cirrhotic patients with splenomegaly. They underwent proximal SAE before- (n = 6) or after (n = 2) laparotomy. Vascular plugs or coils were placed in the proximal splenic artery. The diameter of the portal vein and the splenic volume were recorded. Clinical outcome assessments included platelet counts, the model for end-stage liver disease (MELD) score, and complications. RESULTS: After embolization, the portal venous diameter was significantly smaller (pre: 13.6 ± 2.7 mm, post: 12.5 ± 2.3 mm, p = 0.023), the splenic volume was significantly decreased (pre: 463.2 ± 145.7 ml, post: 373.3 ± 108.5 ml, p = 0.008) and the platelet count was significantly higher (pre: 69.6 ± 30.8 × 103/µl, post: 86.8 ± 27.7 × 103/µl, p = 0.035). Before embolization, the median MELD score was 12; after embolization, it was 11 (p = 0.026). No patient developed post-treatment complications after embolization. CONCLUSIONS: The reduction of hypersplenism by perioperative proximal SAE may be safe and reduce the surgical risk in cirrhotic patients with splenomegaly.


Asunto(s)
Embolización Terapéutica , Enfermedad Hepática en Estado Terminal , Hipertensión Portal , Humanos , Esplenomegalia/etiología , Esplenomegalia/cirugía , Arteria Esplénica/cirugía , Enfermedad Hepática en Estado Terminal/complicaciones , Enfermedad Hepática en Estado Terminal/terapia , Hipertensión Portal/complicaciones , Hipertensión Portal/terapia , Resultado del Tratamiento , Índice de Severidad de la Enfermedad , Embolización Terapéutica/efectos adversos , Cirrosis Hepática/complicaciones , Estudios Retrospectivos
5.
Respir Res ; 24(1): 128, 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37165334

RESUMEN

BACKGROUND: It is clinically important to predict difficulty in short-term liberation from veno-venous extracorporeal membrane oxygenation (V-V ECMO) in patients with severe acute respiratory distress syndrome (ARDS) at the time of initiation of the support. The aim of this study was to identify the characteristics of pulmonary opacities on chest CT that is associated with difficulty in short-term liberation from V-V ECMO (< 14 days). METHODS: This multicenter retrospective study was conducted in adult patients initiated on V-V ECMO for severe ARDS between January 2014 and June 2022. The pulmonary opacities on CT at the time of initiation of the ECMO support were evaluated in a blinded manner, focusing on the following three characteristics of the opacities: (1) their distribution (focal/diffuse on the dorso-ventral axis or unilateral/bilateral on the left-right axis); (2) their intensity (pure ground glass/pure consolidation/mixed pattern); and (3) the degree of fibroproliferation (signs of traction bronchiectasis or reticular opacities). RESULTS: Among the 153 patients, 72 (47%) were successfully liberated from ECMO in the short term, while short-term liberation failed in the remaining 81 (53%) patients. Multivariate logistic regression analysis showed that the presence of mixed-pattern pulmonary opacities and signs of traction bronchiectasis, but not the distribution of the opacities, were independently associated with difficulty in short-term liberation (OR [95% CI]; 4.8 [1.4-16.5] and 3.9 [1.4-11.2], respectively). CONCLUSIONS: The presence of a mixed pattern of the pulmonary opacities and signs of traction bronchiectasis on the chest CT were independently associated with difficulty in short-term liberation from V-V ECMO in severe ARDS patients.


Asunto(s)
Bronquiectasia , Oxigenación por Membrana Extracorpórea , Síndrome de Dificultad Respiratoria , Adulto , Humanos , Estudios Retrospectivos , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/terapia , Tomografía Computarizada por Rayos X
6.
J Nucl Cardiol ; 30(3): 1158-1165, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-35488027

RESUMEN

PURPOSE: How coronary arterial 18F-sodium fluoride (18F-NaF) uptake on positron emission tomography changes over the long term and what clinical factors impact the changes remain unclear. We sought to investigate the topics in this study. METHODS: We retrospectively studied 15 patients with ≥1 coronary atherosclerotic lesion/s detected on cardiac computed tomography who underwent baseline and follow-up (interval of >3 years) 18F-NaF positron emission tomography/computed tomography scans. Focal 18F-NaF uptake in each lesion was quantified using maximum tissue-to-background ratio (TBRmax). The temporal change in TBRmax was assessed using a ratio of follow-up to baseline TBRmax (R-TBRmax). RESULTS: A total of 51 lesions were analyzed. Mean R-TBRmax was 0.96 ± 0.21. CT-based lesion features (location, obstructive stenosis, plaque types, features of high-risk plaque) did not correlate with an increase in R-TBRmax. In multivariate analysis, baseline TBRmax significantly correlated with higher follow-up TBRmax (ß = 0.57, P < 0.0001), and the presence of diabetes mellitus significantly correlated with both higher follow-up TBRmax (ß = 0.34, P = 0.001) and elevated R-TBRmax (ß = 0.40, P = 0.003). CONCLUSION: Higher coronary arterial 18F-NaF uptake is likely to remain continuously high. Diabetes mellitus affects the long-term increase in coronary arterial 18F-NaF uptake.


Asunto(s)
Placa Aterosclerótica , Fluoruro de Sodio , Humanos , Proyectos Piloto , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Radioisótopos de Flúor
7.
J Nucl Cardiol ; 30(6): 2365-2378, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37127726

RESUMEN

PURPOSE: The predictive value of 18F-sodium fluoride (18F-NaF) positron emission tomography (PET) in combination with coronary computed tomography (CT) angiography (CCTA) for future coronary events has attracted interest. We evaluated the potential of 18F-NaF PET/CT following CCTA to predict major coronary events (MACE) during a 5-year follow-up period. METHODS: Forty patients with coronary atherosclerotic lesions detected on CCTA underwent 18F-NaF PET/CT examination. Each lesion was evaluated for luminal stenosis and high-risk plaque (HRP) with < 30 Hounsfield units and a > 1.1 remodeling index on CCTA. Focal 18F-NaF uptake in each lesion was quantified using the maximum tissue-to-background ratio (TBRmax), and the maximum TBRmax per patient (M-TBRmax) was determined. We followed MACE (cardiac death, acute coronary syndrome, and/or coronary revascularization > 6 months after 18F-NaF PET/CT) for 5 years. RESULTS: In total, 142 coronary lesions were analyzed. Eleven patients experienced any MACE. Patients with MACE showed a higher M-TBRmax than those without (1.40 ± .19 vs. 1.18 ± .18, P = .0011), and the optimal M-TBRmax cutoff to predict MACE was 1.29. Patients with M-TBRmax of ≥ 1.29 had a higher risk of MACE than those with lower values (P = .012, log-rank test), whereas patients with obstructive stenosis and those with HRP did not. Multivariate Cox proportional analysis adjusted for age, sex, coronary risk factors, and CCTA findings showed that M-TBRmax of ≥ 1.29 remained an independent predictor of 5-year MACE (hazard ratio, 5.4; 95% confidence interval, 1.1-25.4; P = .034). CONCLUSION: 18F-NaF PET/CT following CCTA provides useful strategies to predict 5-year MACE.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Angiografía por Tomografía Computarizada/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios de Seguimiento , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluoruro de Sodio , Constricción Patológica , Tomografía Computarizada por Rayos X/métodos , Tomografía de Emisión de Positrones , Angiografía , Angiografía Coronaria/métodos
8.
J Comput Assist Tomogr ; 47(4): 530-538, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37380150

RESUMEN

OBJECTIVES: This study aimed to investigate whether machine learning (ML) is useful for predicting the contrast material (CM) dose required to obtain a clinically optimal contrast enhancement in hepatic dynamic computed tomography (CT). METHODS: We trained and evaluated ensemble ML regressors to predict the CM doses needed for optimal enhancement in hepatic dynamic CT using 236 patients for a training data set and 94 patients for a test data set. After the ML training, we randomly divided using the ML-based (n = 100) and the body weight (BW)-based protocols (n = 100) by the prospective trial. The BW protocol was performed using routine protocol (600 mg/kg of iodine) by the prospective trial. The CT numbers of the abdominal aorta and hepatic parenchyma, CM dose, and injection rate were compared between each protocol using the paired t test. Equivalence tests were performed with equivalent margins of 100 and 20 Hounsfield units for the aorta and liver, respectively. RESULTS: The CM dose and injection rate for the ML and BW protocols were 112.3 mL and 3.7 mL/s, and 118.0 mL and 3.9 mL/s ( P < 0.05). There were no significant differences in the CT numbers of the abdominal aorta and hepatic parenchyma between the 2 protocols ( P = 0.20 and 0.45). The 95% confidence interval for the difference in the CT number of the abdominal aorta and hepatic parenchyma between 2 protocols was within the range of predetermined equivalence margins. CONCLUSIONS: Machine learning is useful for predicting the CM dose and injection rate required to obtain the optimal clinical contrast enhancement for hepatic dynamic CT without reducing the CT number of the abdominal aorta and hepatic parenchyma.


Asunto(s)
Medios de Contraste , Tomografía Computarizada por Rayos X , Humanos , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Hígado/diagnóstico por imagen , Peso Corporal , Aorta Abdominal
9.
Heart Vessels ; 38(9): 1095-1107, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37004540

RESUMEN

Fractional flow reserve (FFR) derived off-site by coronary computed tomography angiography (CCTA) (FFRCT) is obtained by applying the principles of computational fluid dynamics. This study aimed to validate the overall reliability of on-site CCTA-derived FFR based on fluid structure interactions (CT-FFR) and assess its clinical utility compared with FFRCT, invasive FFR, and resting full-cycle ratio (RFR). We calculated the CT-FFR for 924 coronary vessels in 308 patients who underwent CCTA for clinically suspected coronary artery disease. Of these patients, 35 patients with at least one obstructive stenosis (> 50%) detected on CCTA underwent both CT-FFR and FFRCT for further investigation. Furthermore, 24 and 20 patients underwent invasive FFR and RFR in addition to CT-FFR, respectively. The inter-observer correlation (r) of CT-FFR was 0.93 (95% confidence interval [CI] 0.85-0.97, P < 0.0001) with a mean absolute difference of - 0.0042 (limits of agreement - 0.073, 0.064); 97.3% of coronary arteries without obstructive lesions on CCTA had negative results for ischemia on CT-FFR (> 0.80). The correlation coefficient between CT-FFR and FFRCT for 105 coronary vessels was 0.87 (95% CI 0.82-0.91, P < 0.0001) with a mean absolute difference of - 0.012 (limits of agreement - 0.12, 0.10). CT-FFR correlated well with both invasive FFR (r = 0.66, 95% CI 0.36-0.84, P = 0.0003) and RFR (r = 0.78, 95% CI 0.51-0.91, P < 0.0001). These data suggest that CT-FFR can potentially substitute for FFRCT and correlates closely with invasive FFR and RFR with high reproducibility. Our findings should be proven by further clinical investigation in a larger cohort.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vasos Coronarios , Reserva del Flujo Fraccional Miocárdico , Hidrodinámica , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Femenino
10.
J Med Syst ; 47(1): 107, 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37851155

RESUMEN

The use of two personal dosimeters, one worn over and one worn under a protective apron, provides the best estimate of effective dose. However, inappropriate positioning of dosimeters is a common occurrence, resulting in abnormally high or low radiation exposure records. Although such incorrect positioning can be identified by radiation exposure records, doing so is time-consuming and labor-intensive for administrators. Therefore, a system that can identify incorrect locations of dosimeters without burdening administrators must be developed. In this study, we developed a radio frequency identification (RFID) gate system that can differentiate between two RFID-tagged dosimeters placed over and under a metal apron and identify misused dosimeters. To simulate the position of the RFID-tagged dosimeters, we designed four dosimeter-wearing classes, including "proper use" and three types of "misuse" (i.e., "reversed," "both under," and "both over"). When the system predicts "misuse" based on the tag reading, the worker is alerted with lights and alarms. The system performance was evaluated using a confusion matrix, with an overall accuracy of 97.75%, demonstrating high classification performance. The safety of the system against life support devices was also investigated, demonstrating that they were not affected by the electric field at 0.3 m or more from the antenna of the system under any transmit powers tested. This RFID gate system is highly capable of identifying incorrectly positioned dosimeters, enabling real-time monitoring of dosimeters to manage their positioning.


Asunto(s)
Dispositivo de Identificación por Radiofrecuencia , Humanos , Dosímetros de Radiación
11.
BMC Gastroenterol ; 22(1): 275, 2022 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-35655156

RESUMEN

BACKGROUND: Patients with hepatocellular carcinoma (HCC) and macrovascular invasion (MVI) who receive systemic chemotherapy have a poor prognosis. This study aimed to determine if one-shot cisplatin (CDDP) chemotherapy via hepatic arterial infusion (HAI) combined with radiation therapy (RT) prior to systemic chemotherapy could improve the outcomes of these patients. METHODS: This study consisted of 32 HCC patients with the following eligibility criteria: (i) portal vein invasion 3/4 and/or hepatic vein invasion 2/3; (ii) received one-shot CDDP via HAI; (iii) received RT for MVI, (iv) a Child-Pugh score ≤ 7; and (v) an Eastern Clinical Oncology Group Performance Status score of 0 or 1. To determine the therapeutic effect, we collected information on patient characteristics and took contrast-enhanced computed tomography at the start of the therapy and every 2 to 4 months after the start of therapy. We evaluated the overall response of the tumor and tumor thrombosis according to modified Response Evaluation Criteria in Solid Tumors. We assessed patient data using the Mann-Whitney U and Fisher exact tests and evaluated overall survival and progression-free survival using the log-rank test. RESULTS: The overall response rate at the first evaluation performed a median of 1.4 weeks after HAI was 16% for the main intrahepatic tumor and 59% for the MVI. The best responses were the same as those of the first-time responses. The duration of median survival was 8.6 months, and progression-free survival of the main intrahepatic tumor was 3.2 months. Predictive factors for overall survival were the relative tumor volume in the liver and the first therapeutic response of MVI. There were no severe adverse events or radiation-induced hepatic complications. CONCLUSIONS: One-shot CDDP via HAI and RT were well tolerated and showed immediate and favorable control of MVI. Thus, this combination shows potential as a bridging therapy to systemic chemotherapy.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Cisplatino/uso terapéutico , Estudios de Cohortes , Humanos , Infusiones Intraarteriales , Estudios Retrospectivos
12.
BMC Gastroenterol ; 22(1): 535, 2022 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-36550416

RESUMEN

BACKGROUND: Balloon-occluded retrograde transvenous obliteration (BRTO) is a treatment option for patients with gastric varices (GVs). This study aimed to clarify the clinical significance of portal hypertension estimated by the hepatic venous pressure gradient (HVPG), subsequent exacerbation of esophageal varices (EVs), and prognosis of patients who underwent BRTO for GVs. METHODS: Thirty-six patients with GVs treated with BRTO were enrolled in this study, and their HVPG was measured before (pre-HVPG) and on the day after BRTO (post-HVPG). After BRTO, patients were followed-up for a median interval of 24.5 (3-140) months. Clinical factors related to EVs exacerbation and prognosis after BRTO were retrospectively analyzed. RESULTS: Post-HVPG increased compared to pre-HVPG in 21 out of 36 patients (58%), and post-HVPG was overall significantly higher compared to pre-HVPG (P = 0.009). During the observation period, 19 patients (53%) developed EVs exacerbation, and the cumulative EVs exacerbation rates at 1, 3 and 5 years after BRTO were 27%, 67%, and 73%, respectively. Pre-HVPG was not related to EVs exacerbation, although elevation of post-HVPG to ≥ 13 mmHg (P < 0.01) and high level of serum aspartate aminotransferase (P < 0.05) were significant independent risk factors for EVs exacerbation after BRTO. Fourteen patients (38.9%) died during the observation period. An elevated value of liver stiffness measurement (LSM) of ≥ 21 kPa was a significant independent risk factor for poor prognosis after BRTO (P < 0.05). CONCLUSIONS: HVPG increases after BRTO. HVPG after BRTO has greater predictive ability for subsequent EVs exacerbation than HVPG before BRTO. LSM is a potential prognostic parameter in patients who undergo BRTO.


Asunto(s)
Oclusión con Balón , Várices Esofágicas y Gástricas , Humanos , Várices Esofágicas y Gástricas/diagnóstico por imagen , Várices Esofágicas y Gástricas/etiología , Várices Esofágicas y Gástricas/terapia , Estudios Retrospectivos , Oclusión con Balón/efectos adversos , Pronóstico , Resultado del Tratamiento , Presión Venosa
13.
J Comput Assist Tomogr ; 46(6): 900-905, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35723670

RESUMEN

OBJECTIVE: Using a chest phantom, we compared the image quality of ultra-high-resolution computed tomography (U-HRCT) images acquired in super high-resolution (SHR) and normal resolution (NR) mode and at the routine radiation dose. The detector size was 0.25 and 0.5 mm, respectively. METHODS: A chest phantom was scanned on a U-HRCT scanner. The scan parameters were tube voltage 120 kV and volume CT dose index 13.0 mGy, the routine radiation dose for conventional scans. The rotation time was 0.5 s/rot, the number of matrices was 512 in NR and 1024 in SHR mode. For physical evaluation, the modulation transfer function was measured on the spherical simulated nodule, and the noise power spectrum on the cylindrical water phantom. A CT value profile curve was created using an in-house simulated bronchial phantom. For visual evaluation, 3 radiologists and 3 radiology technologists evaluated overall image quality using a 4-grade scale (grade 1, poor; and grade 4, excellent). RESULTS: The 10% of modulation transfer function was 13.5 lp/cm in NR and 14.9 lp/cm in SHR mode ( P <0.01). ƒ peak was 5.6 lp/cm in NR and 8.8 lp/cm in SHR mode ( P <0.01), and the peak of noise power spectrum shifted. On the profile curves, the CT value at the edge changed in NR but not in SHR mode. The overall image quality was grade 3.0 ± 0.7 in SHR and grade 2.0 ± 0.7 in NR mode ( P <0.01). CONCLUSIONS: The image quality of SHR mode with U-HRCT was superior to that of NR mode at the routine radiation dose.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Cintigrafía , Dosis de Radiación
14.
J Comput Assist Tomogr ; 46(2): 183-189, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35297575

RESUMEN

OBJECTIVES: The aim of this study was to compare prediction ability between ensemble machine learning (ML) methods and simulation software for aortic contrast enhancement on dynamic hepatic computed tomography. METHODS: We divided 339 human hepatic dynamic computed tomography scans into 2 groups. One group consisted of 279 scans used to create cross-validation data sets, the other group of 60 scans were used as test data sets. To evaluate the effect of the patient characteristics on enhancement, we calculated changes in the contrast medium dose per enhancement of the abdominal aorta in the hepatic arterial phase. The parameters for ML were the patient sex, age, height, body weight, body mass index, and cardiac output. We trained 9 ML regressors by applying 5-fold cross-validation, integrated the predictions of all ML regressors for ensemble learning and the simulations, and used the training and test data to compare their Pearson correlation coefficients. RESULTS: Comparison of different ML methods showed that the Pearson correlation coefficient for the real and predicted contrast medium dose per enhancement of the abdominal aorta was highest with ensemble ML (r = 0.786). It was higher than that obtained with the simulation software (r = 0.350). With ensemble ML, the Bland-Altman limit of agreement [mean difference, 5.26 Hounsfield units (HU); 95% limit of agreement, -112.88 to 123.40 HU] was narrower than that obtained with the simulation software (mean difference, 11.70 HU; 95% limit of agreement, -164.71 to 188.11 HU). CONCLUSION: The performance for predicting contrast enhancement of the abdominal aorta in the hepatic arterial phase was higher with ensemble ML than with the simulation software.


Asunto(s)
Medios de Contraste , Tomografía Computarizada por Rayos X , Peso Corporal , Humanos , Aprendizaje Automático , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos
15.
Heart Vessels ; 37(8): 1446-1452, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35028684

RESUMEN

To evaluate whether the patient-specific contrast enhancement optimizer simulation software (p-COP) is useful for predicting contrast enhancement during whole-body computed tomography angiography (WBCTA). We randomly divided the patients into two groups using a random number table. We used the contrast material (CM) injection protocol selected by p-COP in group A (n = 52). The p-COP used an algorithm including data on the individual patient's cardiac output. Group B (n = 50) was assigned to the conventional CM injection protocol based on body weight. We compared the CT number in the abdominal aorta at the celiac artery level between the two groups and classified them as acceptable (> 280 HU) and unacceptable (< 279 HU) based on the optimal CT number for the WBCTA scans. To evaluate the difference in both injection protocols, we compared the visual inspection of the images of the artery of Adamkiewicz in both protocols. The CM dosage and injection rate in group A were significantly lower than those in group B (480.8 vs. 501.1 mg I/kg and 3.1 vs. 3.3 ml/s, p < 0.05). The CT number of the abdominal aorta at the celiac level was 382.4 ± 62.3 HU in group A and 363.8 ± 71.3 HU in group B (p = 0.23). CM dosage and injection rate were positively correlated to cardiac output for group A (r = 0.80, p < 0.05) and group B (r = 0.16, p < 0.05). The number of patients with an acceptable CT number was higher in group A [46/6 (86.7%)] than in group B [43/7 (71.4%)], but not significant (p = 0.71). The visualization rate for the Adamkiewicz artery was not significantly different between groups A and B (p = 0.89). The p-COP was useful for predicting contrast enhancement during WBCTA with a lower CM dosage and a lower contrast injection rate than that based on the body weight protocol. In patients with lower cardiac output a reduction in contrast injection rate and CM dosage did not lead to a reduced imaging quality, thus particularly in this group CM dosage can be reduced by p-COP.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Peso Corporal , Angiografía por Tomografía Computarizada/métodos , Humanos , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos
16.
J Infect Chemother ; 28(6): 797-801, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35305882

RESUMEN

INTRODUCTION: Despite an increase in CT studies to evaluate patients with coronavirus disease 2019 (COVID-19), their indication in triage is not well-established. The purpose was to investigate the incidence of lung involvement and analyzed factors related to lung involvement on CT images for establishment of the indication for CT scans in the triaging of COVID-19 patients. METHODS: Included were 192 COVID-19 patients who had undergone CT scans and blood tests for triaging. Two radiologists reviewed the CT images and recorded the incidence of lung involvement. The prediction model for lung involvement on CT images using clinico-laboratory variables [age, gender, body mass index, oxygen saturation of the peripheral artery (SpO2), comorbidities, symptoms, and blood data] were developed by multivariate logistic regression with cross-validation. RESULTS: In 120 of the 192 patients (62.5%), CT revealed lung involvement. The patient age (odds ratio [OR]; 4.95, 95% confidence interval [CI]; 0.93-26.49), albumin (OR; 4.66, 95%CI; 1.37-15.84), lactate dehydrogenase (OR; 5.79, 95%CI; 1.43-23.38) and C-reactive protein (OR; 8.93, 95%CI; 4.13-19.29) were selected for the final prediction model for lung involvement on CT images. The cross-validated area under the receiver operating characteristics (ROC) curve was 0.83. CONCLUSIONS: The high incidence of lung involvement (62.5%) was confirmed on CT images. The proposed prediction model that includes the patient age, albumin, lactate dehydrogenase, and C-reactive protein may be useful for predicting lung involvement on CT images and may assist in deciding whether triaged COVID-19 patients should undergo CT.


Asunto(s)
COVID-19 , Proteína C-Reactiva , COVID-19/diagnóstico por imagen , COVID-19/epidemiología , Análisis Factorial , Humanos , Incidencia , Lactato Deshidrogenasas , Pulmón/diagnóstico por imagen , Estudios Retrospectivos , SARS-CoV-2 , Tomografía Computarizada por Rayos X/métodos , Triaje
17.
BMC Pulm Med ; 22(1): 260, 2022 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-35773658

RESUMEN

BACKGROUND: Mesenchymal-epithelial transition exon14 (METex14) skipping is one of the therapeutic driver oncogene mutations in non-small cell lung cancer (NSCLC), and can be treated with tepotinib and capmatinib. There is only one report on computed tomography (CT) findings of METex14 skipping-positive NSCLC, which shows that the primary tumor tends to have a large mass in the upper lobe, and extrathoracic metastases are common. This study examined the CT findings of METex14 skipping-positive NSCLC, focusing on the features of the margins and internal structures. METHODS: We consecutively included patients with METex14 skipping-positive NSCLC who were diagnosed between January 2018 and December 2020 at four independent institutions. We retrospectively reviewed the patient demographics and CT findings for tumor margins (invasion into surrounding tissue, lobulation, pleural indentation, spicula, and ground-glass opacity) and internal structures (air bronchograms, cavitation and internal low-density area). RESULTS: Fifteen patients with METex14 skipping-positive NSCLC were identified. Almost half of the patients were men (7/15; 46.7%), and their median age was 75.0 years. More than half were either current or former smokers (9/15; 60.0%). A vast majority of histological subtypes were adenocarcinoma (10/15; 66.7%), followed by pleomorphic carcinoma (3/15; 20.0%) and squamous cell carcinoma (2/15; 13.3%). With regard to CT findings, most primary tumors presented as masses larger than 30 mm (12/15; 80.0%) and were located in the upper lobes (12/15; 80.0%). Invasion into surrounding tissue and presence of internal low-density areas were observed in 60.0% (9/15) and 66.7% (10/15) of the primary tumors, respectively. Additionally, their frequencies increased to 72.7% (8/11) and 90.9% (10/11) in stage III/IV cases, respectively. In lymph node metastasis, internal low-density areas were observed in 8/10 cases (80.0%). Although these two CT features were rarely observed in distant metastases at diagnosis, they became apparent with progression of the metastatic tumor size. CONCLUSIONS: METex14 skipping-positive NSCLC tumors tend to invade surrounding tissue and possess internal low-density areas. These CT findings might be characteristic of METex14 skipping-positive NSCLC.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Anciano , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/genética , Exones , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/genética , Masculino , Mutación , Proteínas Proto-Oncogénicas c-met/genética , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
18.
Int Heart J ; 63(3): 531-540, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35650153

RESUMEN

The evidence for the clinical implications, especially the short-term utility, of native myocardial T1 value (T1native) on cardiac magnetic resonance (CMR) in nonischemic dilated cardiomyopathy (NIDCM) is scant. We investigated the potential of T1native to assess left ventricular (LV) myocardial characteristics and predict 1-year outcomes in patient with NIDCM experiencing recent heart failure (HF).Forty-five patients with NIDCM and HF symptoms within 3 months underwent CMR with cine, non-contrast T1 mapping, and late gadolinium enhancement (LGE). T1native per patient was defined as an averaged T1 value of 5 short-axis slices of base-to-apex LV myocardium. The appearance of LGE was visually examined. T1native correlated with the LV end-diastolic dimension normalized to height (LVEDD) (r = 0.38, P = 0.0103), ejection fraction (r = -0.39, P = 0.009), and serum N-terminal pro-brain natriuretic peptide levels (r = 0.48, P = 0.001), whereas the presence and segmental extent of LGE correlated only with LVEDD. In the 1-year follow-up cohort, the optimal cutoffs of T1native for predicting LV reverse remodeling (LVRR) and combined cardiac events (cardiac death, ventricular tachycardia/fibrillation, heart failure hospitalization) were 1366 ms and 1377 ms, respectively. In multivariate analysis, T1native < 1366 ms and T1native > 1377 ms remained significant predictors of LVRR (odds ratio, 11.3) and cardiac events (hazard ratio, 15.3), respectively, whereas the presence and segmental extent of LGE did not.T1native in patients with NIDCM experiencing recent HF may offer a promising strategy for assessing LV myocardial characteristics and predicting 1-year LVRR and cardiac events.


Asunto(s)
Cardiomiopatía Dilatada , Insuficiencia Cardíaca , Arritmias Cardíacas , Cardiomiopatía Dilatada/complicaciones , Medios de Contraste , Gadolinio , Insuficiencia Cardíaca/diagnóstico , Humanos , Imagen por Resonancia Cinemagnética/métodos , Miocardio , Remodelación Ventricular
19.
Int Heart J ; 63(3): 466-475, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35650148

RESUMEN

Almost 40% of medical radiation exposure is related to cardiac imaging or intervention. However, the biological effects of low-dose radiation from medical imaging remain largely unknown. This study aimed to evaluate the effects of ionized radiation from cardiac catheterization on genomic DNA integrity and inflammatory cytokines in patients and operators.Peripheral mononuclear cells (MNCs) were isolated from patients (n = 51) and operators (n = 35) before and after coronary angiography and/or percutaneous coronary intervention. The expression of γH2AX, a marker for DNA double-strand breaks, was measured by immunofluorescence. Dicentric chromosomes (DICs), a form of chromosome aberrations, were assayed using a fluorescent in situ hybridization technique.In the patient MNCs, the numbers of γH2AX foci and DICs increased after cardiac catheterization by 4.5 ± 9.4-fold and 71 ± 122%, respectively (P < 0.05 for both). The mRNA expressions of interleukin (IL)-1α, IL-1ß, leukemia inhibitory factor, and caspase-1 were significantly increased by radiation exposure from cardiac catheterization. The increase in IL-1ß was significantly correlated with that of γH2AX, but not with the dose area product. In the operators, neither γH2AX foci nor the DIC level was changed, but IL-1ß mRNA was significantly increased. The protein expression of IκBα was significantly decreased in both groups.DNA damage was increased in the MNCs of patients, but not of operators, who underwent cardiac catheterization. Inflammatory cytokines were increased in both the patients and operators, presumably through NF-κB activation. Further efforts to reduce radiation exposure from cardiac catheterization are necessary for both patients and operators.


Asunto(s)
Exposición a la Radiación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Citocinas , Daño del ADN , Humanos , Hibridación Fluorescente in Situ , ARN Mensajero , Exposición a la Radiación/efectos adversos
20.
Heart Lung Circ ; 31(5): 671-677, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34794871

RESUMEN

BACKGROUND: Numerous studies have shown that 123I-metaiodobenzylguanidine (MIBG) scintigraphy, an index of cardiac sympathetic nervous (CSN) activity, is useful for predicting prognosis in patients with heart failure. However, the factors influencing the CSN activity of patients with severe aortic stenosis (AS) remain unclear. METHODS: We enrolled 91 patients with severe AS who underwent 123I-MIBG scintigraphy, coronary computed tomography (CCT), and transthoracic echocardiography. When CCT angiography (CCTA) showed an obstructive epicardial artery, invasive coronary angiography was performed within 1 week of CCTA. RESULTS: There were 21 male and 70 female patients with a mean age of 84±5 years. Eighty-five (85) patients (93%) had hypertension and 13 patients (14%) had diabetes. Two (2) patients (2%) had previous myocardial infarction and eight (9%) had a previous coronary intervention. All patients had severe AS: aortic valve area was 0.63±0.18 cm2 and the mean pressure gradient was 56±19 mmHg. Regarding 123I-MIBG parameters, early heart-to-mediastinum (H/M) ratio was 3.1±0.5, delayed H/M ratio was 2.8±0.6, and the washout rate (WR) was 35%±13%. Multivariable linear regression analysis showed that coronary artery disease (ß=-0.30, p=0.002) was an independent predictor of delayed H/M ratio, and that aortic valve area (ß=-0.20, p=0.048) was an independent predictor of WR. CONCLUSIONS: Our findings suggest that coronary artery disease is an independent predictor of delayed H/M ratio, and aortic valve area is an independent predictor of WR in patients with severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , 3-Yodobencilguanidina , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Corazón , Humanos , Radioisótopos de Yodo , Masculino , Sistema Nervioso Simpático/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA