Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Kyobu Geka ; 76(8): 642-645, 2023 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-37500554

RESUMEN

A 79-years-old frail man with severe combined valvular disease was referred to our hospital. Furthermore, chest computed tomography( CT) showed a saccular aneurysm in the aortic arch. We chose two staged repairs for risk reduction. As a first stage double valve replacement and tricuspid annuloplasty were performed. Three months later, we performed successful branched thoracic endovascular aortic repair( TEVAR) used physician modified Najuta which had hydrogel-reinforced fenestrations to provide a more secure connection with the bridging graft than fenestrations alone. Staged surgery with branched TEVAR used physician modified Najuta is a useful strategy in patients who have complex cardiac disease combined with aortic arch aneurysm.


Asunto(s)
Aneurisma del Arco Aórtico , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Enfermedades de las Válvulas Cardíacas , Masculino , Humanos , Anciano , Prótesis Vascular , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Reparación Endovascular de Aneurismas , Stents , Resultado del Tratamiento , Diseño de Prótesis , Aneurisma de la Aorta/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía
2.
Kyobu Geka ; 76(5): 358-361, 2023 May.
Artículo en Japonés | MEDLINE | ID: mdl-37150914

RESUMEN

Case 1:A 73-year-old man was transported to our hospital for evaluation of sudden onset of chest pain, back pain, and dyspnea. We initially misdiagnosed him with advanced esophageal cancer accompanied by mediastinal metastasis;however, subsequent multi-detector row computed tomography (MDR-CT) confirmed the diagnosis. We performed coil embolization of a bronchial artery aneurysm and thoracic endovascular aortic repair( TEVAR) to seal the root of the bronchial artery. Case 2:An 81-year-old woman with a one-week history of fever and cervical pain was diagnosed with a ruptured infected thoracic aneurysm. She underwent the same treatment as described in Case 1. Physicians should consider it as a differential diagnosis of mediastinal hematoma.


Asunto(s)
Aneurisma Roto , Rotura de la Aorta , Arterias Bronquiales , Embolización Terapéutica , Procedimientos Endovasculares , Humanos , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Arterias Bronquiales/diagnóstico por imagen , Arterias Bronquiales/cirugía , Mediastino , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos
3.
J Card Surg ; 36(3): 1138-1139, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33527481

RESUMEN

Nutcracker syndrome (NCS) is known as a status of compression of the left renal vein (LRV) between the abdominal aorta and superior mesenteric artery (SMA). We here report a case of NCS in a Marfan syndrome patient with type B aortic dissection who was presented with sudden gross hematuria. Computed tomography revealed the compression of the LRV sandwiched between the SMA and the dilated dissecting abdominal aorta. The compression was released by surgical intervention and the hematuria was promptly resolved. This report highlights that NCS should be considered as a differential diagnosis of unexplained hematuria in patients with a chronic dissecting aorta.


Asunto(s)
Disección Aórtica , Venas Renales , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/cirugía , Hematuria/etiología , Humanos , Arteria Mesentérica Superior
4.
Kyobu Geka ; 74(8): 627-630, 2021 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-34334608

RESUMEN

Bronchial artery aneurysm (BAA) is a rare disease, for which early treatment is recommended due to the risk of rupture often resulting in severe consequences. We report a case of successful treatment of an asymptomatic BAA by selective branch embolization combined with thoracic endovascular aortic repair (TEVAR). A 68-year-old man was accidentally found to have a bronchial artery aneurysm by computed tomography. The distance from the origin of the bronchial artery to the aneurysm was only 6 mm, at which branches were found. The BAA was completely excluded by selective branch coil embolization and deployment of a thoracic stent graft to cover the orifice of the BAA. Angiography confirmed that there was no endoleak. Selective branch embolization of BAA combined with TEVAR is effective to completely occlude the blood stream to BAA.


Asunto(s)
Aneurisma , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Anciano , Aneurisma/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Arterias Bronquiales/diagnóstico por imagen , Humanos , Masculino , Stents , Resultado del Tratamiento
5.
Kyobu Geka ; 74(2): 152-155, 2021 02.
Artículo en Japonés | MEDLINE | ID: mdl-33976024

RESUMEN

A 78-year-old man with mitral regurgitation incidentally diagnosed with aneurysm of the left internal thoracic artery(LITA) and several internal thoracic artery-pulmonary artery( ITA-PA) fistulas originating from the aneurysm. To prevent rupture of the aneurysm, ITA ligation was performed during surgery for the mitral valve. Because of the complex anatomy surrounding the aneurysm, the main duct of the ITA was ligated at the peripheral and center of the aneurysm, then arterial fistulae were resected as many as possible. Postoperative computed tomography (CT), however, showed patent LITA and contrast material in the aneurysm. Second stage coil embolization procedure was performed with successful results. Intravascular treatment is effective for ITA aneurysms or ITA-PA fistulae because we can clearly visualize and confirm blood flow during operation.


Asunto(s)
Aneurisma , Fístula , Arterias Mamarias , Insuficiencia de la Válvula Mitral , Anciano , Aneurisma/complicaciones , Aneurisma/diagnóstico por imagen , Aneurisma/cirugía , Humanos , Masculino , Arterias Mamarias/diagnóstico por imagen , Arterias Mamarias/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía
6.
Kyobu Geka ; 74(2): 130-133, 2021 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-33976019

RESUMEN

A 77-year-old man with a history of coronary artery bypass grafting underwent transcatheter aortic valve replacement(TAVR) via femoral artery for severe aortic stenosis(AS). Preoperative computed tomography(CT) showed there was mild calcification at the sino-tubular junction(STJ). Sapien 3 was implanted successfully, but at the end of full inflation, the balloon ruptured. The ruptured balloon was retrieved without any remnants or vascular injury. A transesophageal echocardiogram showed adequate valve deployment. TAVR with its less invasiveness has become an alternative treatment for high risk patients who cannot endure surgical aortic valve replacement(SAVR). Although there are several complications related to TAVR, they can be predicted in many cases by analysis of preoperative imaging. In this case, the rupture of the balloon was not predicted because there was no significant calcification at the STJ. Caution should be taken even though there seems to be low risk of complications by preoperative imaging modalities.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
Cardiol Young ; 28(12): 1463-1464, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30198454

RESUMEN

We reported a successful case of thoracic endovascular aortic repair of a late aortic aneurysm after patch repair of an interrupted aortic arch and favourable outcome 4 years after the procedure.


Asunto(s)
Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/cirugía , Coartación Aórtica/complicaciones , Procedimientos Endovasculares/métodos , Complicaciones Posoperatorias/cirugía , Adulto , Aorta Torácica/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Coartación Aórtica/cirugía , Humanos , Masculino , Resultado del Tratamiento
8.
Kyobu Geka ; 70(9): 794-797, 2017 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-28790249

RESUMEN

A 66-year-old man developed an extended chronic type B dissection involving the thoraco-abdominal aorta with a large entry at the aortic arch and a patent false lumen. We performed triple-stage endovascular repair which included the vascular plug, endovascular aortic repair and hybrid thoracic endovascular aortic repair. His postoperative course was uneventful and the false lumen was finally thrombosed.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Cateterismo Cardíaco , Procedimientos Endovasculares , Humanos , Imagenología Tridimensional , Masculino , Stents , Tomografía Computarizada por Rayos X
9.
Kyobu Geka ; 70(11): 948-951, 2017 Oct.
Artículo en Japonés | MEDLINE | ID: mdl-29038408

RESUMEN

A 53-year-old woman was referred to us for reoperation of aortic root. Twenty-three years ago, she was diagnosed with aortitis and suffered from annuloaortic ectasia, aortic regurgitation, severe stenosis of left carotid and subclavian arteries and occulusion of the main trunk of left coronary artery. The left coronary system was perfused by collateral arteries from right coronary artery. She had undergone original Bentall procedure( Cooley graft 26 mm+SJM valve 25 mm) with coronary artery bypass grafting (CABG)[saphenous vein graft (SVG)-left anterior descending artery (LAD)]. When she was 52 years old, she suffered from angina on efforts. Computed tomography and catheter angiocardiogram revealed pseudoaneurysm formation due to detachment of right coronary artery button and occulusion of SVG. We underwent redo aortic root replacement (Hemashield graft 26 mm+On-X valve 23 mm) with redo CABG (SVG-LAD). Eight mm graft was interposed between composite valve graft and right coronary button. Postoperative course was uneventful. She was discharged from the hospital on the 17th day, and is now doing well without any symptoms.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Aortitis/cirugía , Puente de Arteria Coronaria , Reoperación , Insuficiencia de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Aortitis/diagnóstico por imagen , Aortitis/etiología , Angiografía por Tomografía Computarizada , Femenino , Humanos , Imagenología Tridimensional , Persona de Mediana Edad , Resultado del Tratamiento
10.
Kyobu Geka ; 69(10): 873-5, 2016 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-27586321

RESUMEN

A 60-year-old woman was transfer-red to the emergency department of our medical center with worsening chest and back pain. Computed tomography revealed Stanford type B aortic dissection. There was a false lumen from the distal arch to the abdominal aorta just above the celiac artery. Although she was at 1st treated conservatively, she abruptly developed acute renal failure and lower limb ischemia because of an enlarged false lumen, and emergency axillo-femoral bypass surgery was performed with an 8 mm tube graft. However, renal failure gradually worsened, which necessitated continuous hemodiafiltration was performed. Thoracic endovascular aortic repair was then performed, and her renal function recovered.


Asunto(s)
Aorta Abdominal/cirugía , Disección Aórtica/cirugía , Isquemia/cirugía , Enfermedad Aguda , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Aorta Abdominal/diagnóstico por imagen , Arteria Axilar/cirugía , Femenino , Arteria Femoral/cirugía , Humanos , Imagenología Tridimensional , Isquemia/complicaciones , Isquemia/diagnóstico por imagen , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
11.
Kyobu Geka ; 69(9): 746-9, 2016 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-27476562

RESUMEN

A 48-year-old man was refered to our hospital for the treatment of bicusp aortic valve and severe aortic regurgitation. He underwent Bentall procedure (SJM 25mm+HemashieldØ 28 mm composite graft). Temporary epicardial pacing lead( TPL) was placed on the right ventricle at the opetation, and was cut on his skin surface prior to discharge because of difficulty in traction removal. After 15 years from operation, follow up computered tomography and echocardiography showed migration of 2 retaining TPLs extending from vascular graft of ascending aorta to the right innominate artery. We performed Redo-median sternotomy and removed the TPLs. This is the 1st reported case of a migrated temporary pacing lead into the vascular graft of ascending aorta under noninfectious conditions.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Procedimientos Quirúrgicos Cardiovasculares , Ecocardiografía Tridimensional , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
12.
Microb Pathog ; 75: 59-67, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25205089

RESUMEN

Vibrio vulnificus, an opportunistic marine bacterium that causes a serious, often fatal, infection in humans, requires iron for its pathogenesis. This bacterium exports vulnibactin for iron acquisition from the environment. The mechanisms of vulnibactin biosynthesis and ferric-vulnibactin uptake systems have recently been reported, while the vulnibactin export system has not been reported. Mutant growth under low-iron concentration conditions and a bioassay of the culture supernatant indicate that the VV1_0612 protein plays a crucial role in the vulnibactin secretion as a component of the resistance-nodulation-division (RND)-type efflux system in V. vulnificus M2799. To identify which RND protein(s) together with VV1_0612 TolC constituted the RND efflux system for vulnibactin secretion, deletion mutants of 11 RND protein-encoding genes were constructed. The growth inhibition of a multiple mutant (Δ11) of the RND protein-encoding genes was observed 6 h after the beginning of the culture. Furthermore, ΔVV1_1681 exhibited a growth curve that was similar to that of Δ11, while the multiple mutant except ΔVV1_1681 showed the same growth as the wild-type strain. These results indicate that the VV1_1681 protein is involved in the vulnibactin export system of V. vulnificus M2799. This is the first genetic evidence that vulnibactin is secreted through the RND-type efflux systems in V. vulnificus.


Asunto(s)
Amidas/metabolismo , Proteínas de Transporte de Membrana/metabolismo , Oxazoles/metabolismo , Vibrio vulnificus/metabolismo , Medios de Cultivo/química , Análisis Mutacional de ADN , ADN Bacteriano/química , ADN Bacteriano/genética , Eliminación de Gen , Proteínas de Transporte de Membrana/genética , Datos de Secuencia Molecular , Análisis de Secuencia de ADN , Vibrio vulnificus/genética , Vibrio vulnificus/crecimiento & desarrollo
13.
Antibiotics (Basel) ; 13(4)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38667011

RESUMEN

Antimicrobial resistance (AMR) has emerged and spread globally. Recent studies have also reported the presence of antimicrobials in a wide variety of aquatic environments. Conducting a nationwide monitoring survey of AMR in the environment to elucidate its status and to assess its impact on ecosystems and human health is of social importance. In this study, we developed a novel high-throughput analysis (HTA) system based on a 96-well plate solid-phase extraction (SPE), using automated pipetting and an SPE pre-treatment system. The effectiveness of the system as an HTA for antimicrobials in environmental water was verified by comparing it with a conventional manual analytical system in a domestic hospital over a period of two years and four months. The results of the manual analysis and HTA using a combination of automated pipetting and SPE systems were generally consistent, and no statistically significant difference was observed (p > 0.05) between the two systems. The agreement ratios between the measured concentrations based on the conventional and HTA methods were positively correlated with a correlation coefficient of r = 0.99. These results indicate that HTA, which combines automated pipetting and an SPE pre-treatment system for rapid, high-volume analysis, can be used as an effective approach for understanding the environmental contamination of antimicrobials at multiple sites. To the best of our knowledge, this is the first report to present the accuracy and agreement between concentrations based on a manual analysis and those measured using HTA in hospital wastewater. These findings contribute to a comprehensive understanding of antimicrobials in aquatic environments and assess the ecological and human health risks associated with antimicrobials and antimicrobial-resistant bacteria to maintain the safety of aquatic environments.

14.
J Cancer Res Clin Oncol ; 150(4): 182, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38592548

RESUMEN

OBJECTIVES: Enfortumab vedotin (EV) is a novel antibody-drug conjugate approved for metastatic urothelial carcinoma (UC) refractory to prior treatment with immune checkpoint inhibitors (ICIs). However, the difference in efficacy of EV after each ICIs and prognostic factors are not well known. We aimed to compare the efficacy of EV in patients with metastatic UC who were treated with avelumab or pembrolizumab and to identify the prognostic factors. METHODS: The records of 100 patients with advanced metastatic UC who received EV after the administration of either avelumab or pembrolizumab were retrospectively collected from five academic hospitals in Japan. RESULTS: The median follow-up period was 6.7 months. The median overall survival (OS) and progression-free survival (PFS) in the EV after avelumab/pembrolizumab group were not reached/14.7 months (p = 0.17) and 10.4/5.2 months (p = 0.039), respectively. The objective response rates (ORR) were 66.6% and 46.8% in EV after avelumab and EV after pembrolizumab groups, respectively (p = 0.14). Multivariate analysis identified histological variants, liver metastasis, low serum albumin levels, and high serum CRP level as significant poor prognostic factors. The median OS and PFS of cachexia patients with both low serum albumin levels and high serum CRP levels were 6.0 months and 0.93 months, respectively. CONCLUSION: PFS was superior in patients treated with EV after avelumab to EV after pembrolizumab. However, OS showed no significant difference between the two groups. Because the prognosis of patients with cachexia is extremely poor, the initiation of EV should be discussed in these patients.


Asunto(s)
Anticuerpos Monoclonales Humanizados , Anticuerpos Monoclonales , Carcinoma de Células Transicionales , Neoplasias de la Vejiga Urinaria , Humanos , Caquexia , Japón/epidemiología , Estudios Retrospectivos , Albúmina Sérica
15.
Hinyokika Kiyo ; 59(1): 47-9, 2013 Jan.
Artículo en Japonés | MEDLINE | ID: mdl-23412125

RESUMEN

A 71-year-old male was admitted for bladder cancer, and we performed a radical cystectomy and urinary diversion by means of an ileal conduit. Twenty days postoperatively, we identified the presence of stool in the stoma and noted the existence of a fistula of the small intestine and ileal conduit urinary diversion. Treatment with fasting, intravenous hyperalimentation and intravenous drip administration of octreotide acetate were performed. The fistula was closed completely 47 days after the surgery. The early complications of urinary diversion by means of an ileal conduit were reported to be urinary tract infections, bowel obstruction, and delayed wound healing, but a fistula between the small intestine and ileal conduit is very rare. We herein report a case of a fistula between the small intestine and ileal conduit used for urinary diversion which thereafter healed by conservative treatment.


Asunto(s)
Fístula Intestinal/terapia , Intestino Delgado , Derivación Urinaria , Anciano , Humanos , Masculino , Complicaciones Posoperatorias , Neoplasias de la Vejiga Urinaria/cirugía
16.
Vasc Endovascular Surg ; 57(4): 411-413, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36617437

RESUMEN

PURPOSE: To report a case of successful endovascular aortic repair for a symptomatic mycotic abdominal aortic aneurysm infected with Listeria monocytogenes. CASE REPORT: We report the case of an 88-year-old woman who presented with acute abdominal pain and vomiting. Approximately a year prior to her presentation, the patient was diagnosed with a mycotic abdominal aortic aneurysm with Listeria monocytogenes and was treated conservatively for more than 2 months at another hospital. At our hospital, contrast-enhanced computed tomography revealed an abdominal aortic aneurysm and an aneurysm of the left internal iliac artery. Endovascular aortic repair was performed successfully. At 16 months after the surgery, the patient remained asymptomatic on long-term antibiotics, and there was no enlargement of the aneurysm. CONCLUSION: Endovascular aortic repair and lifelong antibiotics may be an alternative therapy for mycotic abdominal aortic aneurysms. However, the risk of recurrent infection is high and warrants long-term follow-up.


Asunto(s)
Aneurisma Infectado , Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Listeria monocytogenes , Humanos , Femenino , Anciano de 80 o más Años , Aneurisma Infectado/diagnóstico por imagen , Aneurisma Infectado/cirugía , Reparación Endovascular de Aneurismas , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Antibacterianos/uso terapéutico
17.
Vasc Endovascular Surg ; 57(3): 236-243, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36445850

RESUMEN

Background: As the success of endovascular aortic aneurysm repair (EVAR) depends on sufficient proximal fixation of the endograft to the aortic wall, the proximal hostile neck anatomy (HNA) is the major potential treatment-limiting factor in EVAR. The Aorfix endovascular stent graft was designed to operate on highly angulated aortic necks. The Aligning Orifice of the Renal artery with fish-mouth FIXation (AORFIX) technique uniquely and accurately aligns the trough part of the proximal stent end with the orifice of the lower renal artery and is used to optimize the proximal fish-mouth design for maximum proximal seal use. Herein, we aimed to evaluate the usefulness of the AORFIX technique for EVAR in patients with HNA. Methods: Eighty-one consecutive patients who underwent EVAR with the AORFIX technique (+AORFIX technique group, n = 16) and without (standard group, n = 65) were evaluated. The HNA was defined as any of the following: neck angulation ≥60°, neck length ≤15 mm, or neck thrombus or calcification ≥50% of the circumference and conical neck. Results: Each HNA criterion was similar between the two groups. However, the average number of HNA criteria was significantly higher in the +AORFIX technique group (1.9 ± .2 vs. 1.3 ± .1; P < .01). The two groups showed 100% procedural success. The concurrent renal angioplasty and stenting rates (88% vs. 4.6%; P < .01) were significantly higher in the +AORFIX technique group. There were no 30-day deaths in either group and no in-hospital device-related events in the +AORFIX technique group. The median follow-up period was 39 months, and there was no significant between-group difference in freedom from reintervention rate (+AORFIX group vs. standard group, 100% vs. 91.0%; P = .327). Conclusion: EVAR using the AORFIX technique might be useful even in patients with more complex HNA.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Arteria Renal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Resultado del Tratamiento , Stents , Boca/cirugía , Diseño de Prótesis
18.
Ultrasonics ; 129: 106890, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36462461

RESUMEN

Echo imaging in ultrasound computed tomography (USCT) using the synthetic aperture technique is performed with the assumption that the speed of sound is constant in the system. However, tissue heterogeneity causes a mismatch between the predicted arrival time and the actual arrival time of the echo signal, which will result in phase aberration, leading to the quality degradation of the reconstructed B-mode image. The conventional correction methods that use the correlation of each different channel require the presence of strong point scatterers and involve the problem of local solutions due to excessive correction. In this study, we propose a novel approach to correcting the signal distortion due to sound speed heterogeneity using a deep neural network (DNN). The DNN was trained to convert the distorted radio frequency (RF) inputs for the heterogeneous medium to the distortion-free RF outputs for the homogeneous medium. The network with U-net architecture using ResNet-34 as a backbone was trained using the hetero-homo corresponding channel-domain RF data generated via numerical simulations. The trained network performed phase aberration correction in the channel-domain RF, with the B-mode images reconstructed with the corrected RF demonstrating a higher contrast and an improved resolution compared with uncorrected cases. It was also demonstrated that the DNN model is robust to both varied reflection intensities and varied sound speed heterogeneities. The successful results demonstrated that the proposed DNN-based method is effective for phase aberration correction in US imaging.


Asunto(s)
Aprendizaje Profundo , Algoritmos , Ultrasonografía/métodos , Tomografía Computarizada por Rayos X , Redes Neurales de la Computación , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador/métodos
19.
Antibiotics (Basel) ; 12(5)2023 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-37237835

RESUMEN

Antimicrobial resistance (AMR) is becoming a global concern. Recently, research has emerged to evaluate the human and environmental health implications of wastewater from medical facilities and to identify acceptable wastewater treatment methods. In this study, a disinfection wastewater treatment system using an ozone-based continuous flow system was installed in a general hospital located in Japan. The effectiveness of antimicrobial-resistant bacteria (ARB) and antimicrobials in mitigating the environmental impact of hospital wastewater was evaluated. Metagenomic analysis was conducted to characterize the microorganisms in the wastewater before and after treatment. The results demonstrated that ozone treatment enables effective inactivation of general gut bacteria, including Bacteroides, Prevotella, Escherichia coli, Klebsiella, DNA molecules, and ARGs, as well as antimicrobials. Azithromycin and doxycycline removal rates were >99% immediately after treatment, and levofloxacin and vancomycin removal rates remained between 90% and 97% for approximately one month. Clarithromycin was more readily removed than the other antimicrobials (81-91%), and no clear removal trend was observed for ampicillin. Our findings provide a better understanding of the environmental management of hospital wastewater and enhance the effectiveness of disinfection wastewater treatment systems at medical facilities for mitigating the discharge of pollutants into aquatic environments.

20.
Regen Ther ; 24: 574-581, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38028937

RESUMEN

Introduction: Spinal cord injury (SCI) is associated with severe dysfunction of nervous tissue, and repair via the transplantation of bone marrow-derived mononuclear cells (BM-MNCs) into cerebrospinal fluid yields promising results. It is essential to understand the underlying mechanisms; therefore, this study aimed to evaluate the regenerative potential of autologous BM-MNC transplantation in a canine model of acute SCI. Methods: Six dogs were included in this study, and SCI was induced using an epidural balloon catheter between L2 and L3, particularly in the area of the anterior longitudinal ligament. BM-MNC transplantation was performed, and T2-weighted magnetic resonance imaging (MRI) was conducted at specific time points (i.e., immediately after inducing SCI and at 1, 2, and 4 weeks after inducing SCI); moreover, the expression of growth-associated protein 43 (GAP-43) was evaluated. Results: MRI revealed that the signal intensity reduced over time in both BM-MNC-treated and control groups. However, the BM-MNC-treated group exhibited a significantly faster reduction than the control group during the early stages of SCI induction (BM-MNC-treated group: 4.82 ± 0.135 cm [day 0], 1.71 ± 0.134 cm [1 week], 1.37 ± 0.036 cm [2 weeks], 1.21 cm [4 weeks]; control group: 4.96 ± 0.211 cm [day 0], 2.49 ± 0.570 cm [1 week], 1.56 ± 0.045 cm [2 weeks], 1.32 cm [4 weeks]). During the early stages of treatment, GAP-43 was significantly expressed at the proximal end of the injured spinal cord in the BM-MSC-treated group, whereas it was scarcely expressed in the control group. Conclusions: In SCI, transplanted BM-MNCs can activate the expression of GAP-43, which is involved in axonal elongation (an important process in spinal cord regeneration). Thus, cell therapy with BM-MNCs can provide favorable outcomes in terms of better regenerative capabilities compared with other therapies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA