Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Vasa ; 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39017671

RESUMEN

Background: Bifemoral arterial access is common in patients undergoing transcatheter aortic valve implantation (TAVI), with a primary treatment access (TAVI access) and a secondary non-TAVI access. Pseudoaneurysm (PSA) is an important complication of femoral arterial puncture. Major vascular complications after TAVI are well described, but little is known about PSA. Patients and methods: A total of 2063 patients underwent transfemoral TAVI between January 2014 and January 2020. Vascular ultrasound of the common femoral artery was assessed before and after TAVI. We compared patient characteristics, periprocedural risk scores, procedural characteristics, and access site bleeding events according to Valve Academic Research Consortium 3 (VARC-3) criteria, length of stay (LOS), and all-cause mortality at one year between patients with (46) and without (2017) PSA. Results: The incidence of PSA after TAVI was 2.2% (46/2063). All PSA were successfully treated with ultrasound-guided manual compression (UGMC) or thrombin injection (UGTI) without complications. Patients with PSA had lower platelet counts (210×1000/µl vs. 234×1000/µl; p<0.05), more heart failure symptoms on admission (91% vs. 25%; p<0.05), were more often treated with (N)OACs for atrial fibrillation (AF; 54% vs. 38%; p <0.05), and were less often treated with aspirin (35% vs. 51%; p<0.03). Multivariate analysis identified secondary access site (odds ratio [OR] 8.11; p<0.001) and (N)OAC therapy (OR 1.31; p = 0.037) as risk factors for PSA development. PSA is associated with VARC-3 type 1-3 access site bleeding and longer LOS (15.2 ± 11.3 d vs. 11.6 ± 8.9 d; p<0.01), but this did not affect one year mortality (17% vs. 14%; p = 0.53). Conclusions: Pseudoaneurysms are an important complication after TAVI and are associated with access site bleeding and prolonged hospital stay. (N)OAC therapy and secondary access are important risk factors. Pseudoaneurysms can be safely and effectively treated with thrombin injection and do not affect one-year mortality.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38943384

RESUMEN

BACKGROUND: Data on the effect of transcatheter aortic valve implantation (TAVI) on peripheral microcirculation are limited. OBJECTIVE: The aim of this study is to evaluate peripheral microvascular tissue saturation (StO2) before and after TAVI in relation to central and peripheral hemodynamics, cardiac and renal function. METHODS: In this single-center prospective study, patients with severe aortic stenosis (sAS) scheduled for TAVI or cardiac catheterization (control) were assessed before and up to five days after the procedure. Cardiac function including cardiac output (CO) was assessed by echocardiography. Brachial (bBP) and central blood pressure (cBP), ankle brachial index (ABI), and parameters of arterial stiffness, including augmentation pressure (AP) and augmentation index adjusted for heart rate (AIx@HR75) were measured to assess hemodynamic changes. StO2 was measured in all extremities using a near-infrared spectroscopy (NIRS) camera. Renal function was measured by creatinine levels. RESULTS: 26 patients underwent TAVI and 11 patients served as control. Cardiac output was significantly increased, whereas hemodynamic parameters and peripheral StO2 were significantly decreased after TAVI. At follow-up, StO2 returned to baseline values. Changes in StO2 were negatively related to creatinine levels. CONCLUSION: Transcatheter aortic valve implantation causes a temporary decrease in microvascular tissue saturation that is associated with renal function.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA