Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
AJNR Am J Neuroradiol ; 20(8): 1567-71, 1999 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10512247

RESUMEN

BACKGROUND AND PURPOSE: Transcranial color-coded duplex sonography (TCCS) allows the noninvasive, easily reproducible measurement of midline dislocation (MLD) of the third ventricle in space-occupying stroke, even in critically ill patients. However, the method has been validated only in a small number of subjects. The aim of this study was to test the method under clinical conditions. METHODS: In 61 prospectively recruited patients (mean age, 62+/-15 years) with supratentorial ischemic infarction or intracranial hemorrhage, the sonographic measurement of MLD was compared with cranial CT data in a 12-hour time window. Subgroup analysis was also undertaken for comparing TCCS and cranial CT measurements within a 3-hour time window. RESULTS: One hundred twenty-two data pairs of TCCS and cranial CT MLD measurements were correlated within the 12-hour time window. TCCS and cranial CT measurements of MLD correlated both in the total patient group and in the different subgroups with coefficients of over 0.9. The 2-SD confidence interval of the difference between the TCCS measurements and the respective means of both methods in the total patient collective was +/-1.78 mm. CONCLUSION: TCCS provides a noninvasive, easily reproducible and reliable method for monitoring MLD of the third ventricle in stroke patients. It is particularly suitable for critically ill patients who are not fit for transportation.


Asunto(s)
Infarto de la Arteria Cerebral Media/diagnóstico , Hemorragias Intracraneales/diagnóstico , Tercer Ventrículo/patología , Tomografía Computarizada por Rayos X , Ultrasonografía Doppler Transcraneal , Adulto , Anciano , Anciano de 80 o más Años , Cuidados Críticos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
2.
J Neuroimaging ; 11(4): 385-92, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11677878

RESUMEN

BACKGROUND AND PURPOSE: Venous transcranial color-coded duplex sonography is a new technique for noninvasive evaluation of the intracranial venous system. However, the interobserver and intraobserver reliability of this method is unclear. METHODS: In 23 healthy volunteers (30 +/- 7.3 years of age), the deep middle cerebral vein (dMCV), basal vein (BV), vein of Galen (VG), and straight (SRS), transverse (TS), and superior sagittal (SSS) sinuses in addition to the arterial segments of the circle of Willis were insonated through the temporal bone window on 2 consecutive days by 2 experienced examiners. The examiners were blinded to each other's results. The interobserver and intraobserver reliability was calculated using a method described by Bland and Altman, resulting in 2-SD confidence intervals. RESULTS: Non-angle-corrected and angle-corrected systolic and end diastolic venous flow velocities (FV) were in good accordance with published normal values, ranging between 8.6 and 19.2 cm/s. The interobserver reliabilities for non-angle-corrected systolic FVs in the dMCV, BV, VG, SRS, and TS were +/- 1.8, 2.4, 2.6, 3.3, and 4.6 cm/s; for angle-corrected systolic FVs, the interobserver reliabilities were +/- 2.5, 3.1, 13.9, 11.6, and 7.7 cm/s. The intraobserver reliabilities for non-angle-corrected systolic FVs in the dMCV, BV, VG, SRS, and TS were +/- 2.9, 3.2, 2.6, 3.2, and 6.1 cm/s; for angle-corrected systolic FVs, the intraobserver reliabilities were 3.2, 3.7, 13.9, 11.6, and 7.5 cm/s. Angle correction was not attempted for the SSS. The interobserver and intraobserver reliabilities for systolic FVs in the SSS were +/- 3.3 and +/- 3.3 cm/s, respectively. CONCLUSIONS: Intracranial venous FVs can be measured with a high interobserver and intraobserver reliability in healthy human subjects. Intraobserver reliability was higher for cerebral veins than for dural sinuses, predisposing them for follow-up examinations; however, angle correction for venous FVs in the VG and the SRS is not advisable.


Asunto(s)
Venas Cerebrales/diagnóstico por imagen , Ultrasonografía Doppler en Color , Ultrasonografía Doppler Transcraneal , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Circulación Cerebrovascular , Femenino , Hemodinámica , Humanos , Masculino , Variaciones Dependientes del Observador , Flujo Sanguíneo Regional/fisiología , Estadísticas no Paramétricas , Posición Supina
3.
Stroke ; 30(5): 1070-5, 1999 May.
Artículo en Inglés | MEDLINE | ID: mdl-10229746

RESUMEN

BACKGROUND AND PURPOSE: Transcranial color-coded duplex sonography (TCCS) of intracranial veins and sinuses in adults is a new, emerging application of ultrasonographic imaging. This study reports a standardized examination protocol for venous TCCS and provides reference data for clinical application. METHODS: In 130 healthy volunteers (mean age, 45.9+/-16.9 years; range, 14 to 77 years) the intracranial venous system was examined using frequency-based transtemporal TCCS. Identification rate, blood flow velocity, resistance index, and systolic/diastolic ratio were recorded for each examined venous vessel. RESULTS: Intracranial veins and sinuses show a low pulsatile forward flow with maximal systolic blood flow velocity up to 20 cm/s. Significant side differences of blood flow velocity in the paired venous structures could not be detected. Venous flow velocities decreased with age, whereas resistance indices and systolic/diastolic ratios increased. Women showed higher flow velocities than men. Mean identification rates for all age groups ranged from 70% to 90% for the deep middle cerebral vein, the basal cerebral vein, and the great cerebral vein of Galen. The straight sinus, the transverse sinus, and the rostral part of the superior sagittal sinus could be detected in 55% to 70% of cases. Detection rates were dependent on age and decreased as age increased. CONCLUSIONS: Venous TCCS can reliably image a significant part of the cerebral venous system. This method can provide information on venous hemodynamics in normal subjects and pathological cases.


Asunto(s)
Arterias Cerebrales , Venas Cerebrales , Circulación Cerebrovascular , Ultrasonografía Doppler en Color/normas , Ultrasonografía Doppler Transcraneal/normas , Adolescente , Adulto , Anciano , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flujo Pulsátil , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA