1.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38582974

RESUMEN

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Criocirugía , Taquicardia Ventricular , Anciano , Humanos , Persona de Mediana Edad , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/cirugía , Ablación por Catéter/efectos adversos , Cicatriz/complicaciones , Criocirugía/efectos adversos , Estudios Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Temperatura , Resultado del Tratamiento
2.
Europace ; 25(3): 1015-1024, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36746553

RESUMEN

AIMS: Stereotactic arrhythmia radiotherapy (STAR) is suggested as potentially effective and safe treatment for patients with therapy-refractory ventricular tachycardia (VT). However, the current prospective knowledge base and experience with STAR is limited. In this study we aimed to prospectively evaluate the efficacy and safety of STAR. METHODS AND RESULTS: The StereoTactic Arrhythmia Radiotherapy in the Netherlands no.1 was a pre-post intervention study to prospectively evaluate efficacy and safety of STAR. In patients with therapy-refractory VT, the pro-arrhythmic region was treated with a 25 Gy single radiotherapy fraction. The main efficacy measure was a reduction in the number of treated VT-episodes by ≥50%, comparing the 12 months before and after treatment (or end of follow-up, excluding a 6-week blanking period). The study was deemed positive when ≥50% of patients would meet this criterion. Safety evaluation included left ventricular ejection fraction, pulmonary function, and adverse events. Six male patients with an ischaemic cardiomyopathy were enrolled, and median age was 73 years (range 54-83). Median left ventricular ejection fraction was 38% (range 24-52). The median planning target volume was 187 mL (range 93-372). Four (67%) patients completed the 12-month follow-up, and two patients died (not STAR related) during follow-up. The main efficacy measure of ≥50% reduction in treated VT-episodes at the end of follow-up was achieved in four patients (67%). The median number of treated VT-episodes was reduced by 87%. No reduction in left ventricular ejection fraction or pulmonary function was observed. No treatment related serious adverse events occurred. CONCLUSIONS: STAR resulted in a ≥ 50% reduction in treated VT-episodes in 4/6 (67%) patients. No reduction in cardiac and pulmonary function nor treatment-related serious adverse events were observed during follow-up. CLINICAL TRIAL REGISTRATION: Netherlands Trial Register-NL7510.


Asunto(s)
Radiocirugia , Taquicardia Ventricular , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Corazón , Radiocirugia/efectos adversos , Radiocirugia/métodos , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/radioterapia , Resultado del Tratamiento , Función Ventricular Izquierda
3.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37967257

RESUMEN

AIMS: During the diagnostic work-up of patients with idiopathic ventricular fibrillation (VF), next-generation sequencing panels can be considered to identify genotypes associated with arrhythmias. However, consensus for gene panel testing is still lacking, and variants of uncertain significance (VUS) are often identified. The aim of this study was to evaluate genetic testing and its results in idiopathic VF patients. METHODS AND RESULTS: We investigated 419 patients with available medical records from the Dutch Idiopathic VF Registry. Genetic testing was performed in 379 (91%) patients [median age at event 39 years (27-51), 60% male]. Single-gene testing was performed in 87 patients (23%) and was initiated more often in patients with idiopathic VF before 2010. Panel testing was performed in 292 patients (77%). The majority of causal (likely) pathogenic variants (LP/P, n = 56, 15%) entailed the DPP6 risk haplotype (n = 39, 70%). Moreover, 10 LP/P variants were found in cardiomyopathy genes (FLNC, MYL2, MYH7, PLN (two), TTN (four), RBM20), and 7 LP/P variants were identified in genes associated with cardiac arrhythmias (KCNQ1, SCN5A (2), RYR2 (four)). For eight patients (2%), identification of an LP/P variant resulted in a change of diagnosis. In 113 patients (30%), a VUS was identified. Broad panel testing resulted in a higher incidence of VUS in comparison to single-gene testing (38% vs. 3%, P < 0.001). CONCLUSION: Almost all patients from the registry underwent, albeit not broad, genetic testing. The genetic yield of causal LP/P variants in idiopathic VF patients is 5%, increasing to 15% when including DPP6. In specific cases, the LP/P variant is the underlying diagnosis. A gene panel specifically for idiopathic VF patients is proposed.


Asunto(s)
Arritmias Cardíacas , Fibrilación Ventricular , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/genética , Fibrilación Ventricular/epidemiología , Arritmias Cardíacas/genética , Pruebas Genéticas
4.
Pacing Clin Electrophysiol ; 46(7): 574-582, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37254956

RESUMEN

INTRODUCTION: Over the past years, mapping and ablation techniques for the treatment of ventricular tachycardia (VT) have evolved rapidly. High Density (HD) substrate mapping is now routine and pre-procedural imaging is increasingly used. The additional value of these techniques for long-term VT-free survival is not clear. METHODS: We compared baseline and procedural characteristics, procedural success, safety and outcome of mapping and ablation of ventricular tachycardia in patients with ischemic heart disease between two groups. (1) Low Density (LD) group: VT mapping and ablation with a 4 mm single tip catheter (2) HD group: HD substrate mapping with the Pentaray (Biosense Webster, USA) or HD Grid (Abbott, USA) catheter and ablation with a 4 mm single tip catheter. RESULTS: VT ablation was performed in 133 patients (71 patients in LD group and 62 patients in HD group). The median follow-up was 5.0 years in LD group and 2.0 years in HD group. One-, two-, and five-year VT recurrence rates were 47%, 56%, and 65% in the LD group versus 39%, 50%, and 55% in the HD group (log-rank test for VT recurrence p = .70). One-, two-, and five-year ICD shock recurrence rates were 14%, 18%, and 24% in the LD group versus 8%, 15%, and 19% in the HD group (log-rank test for ICD-shock p = .79). All-cause mortality, cardiac (non-arrhythmic), and arrhythmic death, were similar in both groups. Severe procedural complications (tamponade, stroke, or procedural death) occurred in four patients (5%, 1 vascular, 3 tamponade) in the LD group versus two patients (3%, both tamponade) in the HD group (NS). In univariate and multivariable analysis, only a higher LVEF was significantly associated with VT-free survival. HD mapping was not significantly associated with VT-free survival. Anterior infarct location and age were significantly associated with ICD recurrent shock in both univariate and multivariable analyses. CONCLUSIONS: In patients with ischemic cardiomyopathy, a HD substrate mapping, and ablation strategy did not lead to higher VT-free survival and shock-free survival compared to a single tip mapping and ablation strategy. In this study, only LVF is an independent predictor for VT recurrence. Anterior infarct location and age predict recurrent ICD shocks.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Resultado del Tratamiento , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/cirugía , Cardiomiopatías/complicaciones , Cardiomiopatías/cirugía , Infarto/complicaciones , Infarto/cirugía , Ablación por Catéter/métodos , Recurrencia
5.
Pacing Clin Electrophysiol ; 46(11): 1403-1411, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37724739

RESUMEN

BACKGROUND: High-density (HD) mapping is increasingly used to characterize arrhythmic substrate for ablation of atypical atrial flutters (AAFl). However, results on clinical outcomes and factors that are associated with arrhythmia recurrence are scarce. METHODS: Single-center, prospective, observational cohort study that enrolled patients with catheter ablation for AAFl using a HD mapping system and a grid-shaped mapping catheter. Procedural characteristics, rates of atrial flutter recurrence, and factors that were associated with atrial flutter recurrence were evaluated. RESULTS: Sixty-one patients with a total of 94 AAFl were included in the cohort. HD mapping was used to successfully identify the flutter circuit of 80/94 AAFl. The circuit was not identified for 14/94 AAFl in 11 patients. Critical isthmuses were identified and ablated in 29 patients (48%). Acute procedural success was achieved in 52 patients (85%), and 37 patients (61%) remained free from atrial flutter recurrence during a follow up of 1.3 [1.0-2.1] years. Atrial flutter recurrence was univariably associated with presence of a non-identified flutter circuit (HR:2.6 95% CI [1.1-6.3], p = .04) and critical isthmus-targeted ablation (HR:0.4 [0.15-0.90], p = .03). In multivariable regression analyses, critical isthmus ablation remained significant (HR:0.4 [0.16-0.97], p = .04), whereas presence of a non-identified flutter did not (HR:2.4 [0.96-5.8], p = .06). CONCLUSION: HD mapping was successfully used to identify the majority of AAFl circuits. Ablation resulted in freedom from atrial flutter recurrence in 61% of the cohort. Successful identification of all flutter circuits and critical isthmuses appears to be beneficial for long-term outcomes.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Estudios Prospectivos , Estudios de Cohortes , Ablación por Catéter/métodos
6.
J Cardiovasc Electrophysiol ; 33(6): 1272-1280, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35411644

RESUMEN

BACKGROUND: Cardiac sarcoidosis (CS) is associated with an increased risk for sudden cardiac death. An implantable cardiac defibrillator (ICD) is recommended in a subgroup of CS patients. However, the recommendations for primary prevention differ between guidelines. The purpose of the study was to evaluate the efficacy and safety of ICDs in CS and to identify predictors of appropriate therapy. METHODS: A retrospective cohort study was performed in CS patients with an ICD implantation between 2010 and 2019. Primary outcome was appropriate ICD therapy. Independent predictors were calculated using Cox proportional hazard analysis. RESULTS: 105 patients were included. An ICD was implanted for primary prevention in 79%. During a median follow-up of 2.8 years, 34 patients (32.4%) received appropriate ICD therapy of whom 24 (22.9%) received an appropriate shock. Three patients (2.9%) received an inappropriate shock due to atrial fibrillation. Independent predictors of appropriate therapy included prior ventricular arrhythmias (hazard ratio [HR]: 10.5 [95% confidence interval (CI): 5.0-21.9]) and right ventricular late gadolinium enhancement (LGE) (HR: 3.6 [95% CI: 1.7-7.6]). Within the primary prevention group, right ventricular LGE (HR: 5.7 [95% CI: 1.6-20.7]) was the only independent predictor of appropriate therapy. Left ventricular ejection fraction did not differ between patients with and without appropriate therapy (44.4% vs. 45.6%, p = .70). CONCLUSION: In CS patients with an ICD, a high rate of appropriate therapy was observed and a low rate of inappropriate shocks. Prior ventricular arrhythmias and right ventricular LGE were independent predictors of appropriate therapy.


Asunto(s)
Desfibriladores Implantables , Miocarditis , Sarcoidosis , Antiarrítmicos , Arritmias Cardíacas , Medios de Contraste , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Gadolinio , Humanos , Miocarditis/complicaciones , Estudios Retrospectivos , Factores de Riesgo , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico , Sarcoidosis/terapia , Volumen Sistólico , Función Ventricular Izquierda
7.
J Cardiovasc Electrophysiol ; 33(3): 559-564, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35040534

RESUMEN

BACKGROUND: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study. METHODS: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow-up data were collected for patients who developed persistent PNP. RESULTS: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty-four (0.7%) patients developed persistent PNP and follow-up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional-RF, phased-RF, cryoballoon, and thoracoscopic ablation respectively. Seventy-one percent of the patients fully recovered, and 86% were free of PNP-related symptoms after a median follow-up of 203 (113-351) and 184 (82-359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery. CONCLUSION: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Parálisis/etiología , Nervio Frénico , Venas Pulmonares/cirugía , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 45(9): 1085-1089, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35929420

RESUMEN

In the latest generation Biotronik cardiac resynchronization devices, cardiac resynchronization therapy (CRT) may be inadvertently interrupted due to automatic sense testing. This issue can easily be recognized during device interrogation by the "CRT interrupt warning."To avoid CRT interruption, both understanding of the algorithm and correct device programming are critical. The automatic sense testing algorithm has no built-in protection to avoid CRT interrupted pacing. When implanting this generation of devices programming needs to be adequate to avoid the occurrence of this phenomenon.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Dispositivos de Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Humanos
9.
J Cardiovasc Electrophysiol ; 32(4): 1140-1146, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33629788

RESUMEN

Electroanatomic mapping systems have become an essential tool to guide the identification and ablation of arrhythmic substrate. Recently, a novel guiding system for electrophysiology procedures was introduced that uses dielectric sensing to perform high resolution anatomical imaging. Dielectric imaging systems use electrical fields to differentiate anatomic structures based on their conductivity and permittivity. This technique enables non-fluoroscopic, noncontact mapping of anatomic structures, assessment of pulmonary vein occlusion state during cryoballoon ablation, and has the potential to assess for additional tissue characterization including tissue thickness and tissue type. This article elaborates on the functioning and potential of dielectric imaging systems and provides two cases to illustrate the clinical impact for electrophysiology procedures.


Asunto(s)
Ablación por Catéter , Electrofisiología Cardíaca , Humanos , Tecnología
10.
Europace ; 23(12): 1931-1938, 2021 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-34279627

RESUMEN

AIMS: Pulmonary vein isolation (PVI) for atrial fibrillation (AF) has become increasingly safe and effective with the evolution of single-tip ablation catheters aided by contact force sensing (ST-CF) and single-shot devices such as the second-generation pulmonary vein ablation catheter (PVAC) Gold multi-electrode array. The multicentre randomized GOLD FORCE trial was conducted to evaluate non-inferiority of safety and efficacy of PVAC Gold PVI compared to ST-CF ablation for paroxysmal AF. METHODS AND RESULTS: The primary efficacy endpoint documented AF recurrence ≥30 s was assessed by time-to-first-event analysis after a 90-day blanking period using repeated 7-day Holters. Secondary endpoints include acute success and procedural characteristics. Safety endpoints included procedural complications, stroke/transient ischaemic attack (TIA), tamponade, bleeding, and access site complications. Two hundred and eight patients underwent randomization and PVI (103 assigned to PVAC Gold, 105 to ST-CF). Acute success rates were 95% and 97% for PVAC Gold and ST-CF, respectively. At 12 months, AF recurrence was observed in 46.6% of the PVAC Gold group and in 26.2% of the ST-CF group [absolute efficacy difference 20.4% (95% confidence interval, CI 7.5-33.2%), hazard ratio 2.05 (95% CI 1.28-3.29), P = 0.003]. PVAC Gold had significantly shorter procedure and ablation times. Complication rates were 5.7% and 4.9% for PVAC Gold and ST-CF, respectively (P = 0.782). CONCLUSION: In this multicentre randomized clinical trial, ablation with ST-CF and PVAC Gold ablation catheters non-inferiority for efficacy was not met. AF recurrence was significantly more frequent in the PVAC Gold group compared to single-tip contact force group. Both groups had similarly low rates of adverse events. PVAC Gold ablation had significantly shorter procedure and ablation times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Catéteres , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
11.
Europace ; 23(2): 216-225, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33141152

RESUMEN

AIMS: Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1-3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation. METHODS AND RESULTS: The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P ≤ 0.001) and vascular complications (C-RF 1.7% vs. Ph-RF 1.2% vs. CB 1.3%, P ≤ 0.001). Ph-RF was associated with fewer bleeding complications (C-RF: 1.0% vs. Ph-RF: 0.4% vs. CB: 0.7%, P = 0.020). Phrenic nerve palsy mainly occurred in patients treated with CB (C-RF: 0.1% vs. Ph-RF: 0.2% vs. CB: 1.5%, P ≤ 0.001). In total, 18.4% of patients were referred for repeat ablation within 1 year. Female sex, age, and CHA2DS2-VASc were independent risk factors for cardiac tamponade and bleeding complications, with an adjusted OR for female patients of 2.97 (95% CI 1.98-4.45) and 2.02 (95% CI 1.03-4.00) respectively. CONCLUSION: The reported complication rate during PVI was low. Patients treated with C-RF ablation were more likely to develop cardiac tamponades and vascular complications. Female sex was associated with more cardiac tamponade and bleeding complications.


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Países Bajos/epidemiología , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 31(2): 536-543, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31944462

RESUMEN

INTRODUCTION: In patients with a prior myocardial infarction (MI) but preserved left ventricular (LV) function, sustained ventricular arrhythmias (VAs) may arise in the setting of an acute coronary syndrome (ACS). It is unknown whether an implantable cardioverter-defibrillator (ICD) is mandatory in these patients as VA might be triggered by a reversible cause. The purpose of this study is to analyze the benefit of ICD therapy in this patient population. METHODS: We conducted a retrospective observational study in ICD recipients implanted from 2008 to 2011. The study group consisted of patients with sustained VA in the setting of an ACS, with a history of MI, but with left ventricular ejection fraction (LVEF) greater than 35 (group A). The two control groups consisted of patients admitted with VA with a history of MI, but without ACS at presentation, either with LVEF greater than 35% (group B) or ≤35% (group C). The primary endpoint was the number of patients with appropriate ICD therapy (antitachycardia pacing or shock). RESULTS: A total of 291 patients were included with a mean follow-up of 5.3 years. Appropriate ICD therapy occurred in 45.6% of the patients in group A vs 51.6% and 60.4% in groups B and C (P = .11). In group A, 31.1% received an appropriate ICD shock vs 34.7% and 44.3% in control groups B and C (P = .12). CONCLUSION: On the basis of these data, ICD implantation seems warranted in patients with history of MI presenting with VA in the setting of an ACS, despite preserved LV function and adequate revascularization. Further trials, preferably randomizes, should be performed to address these findings.


Asunto(s)
Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Infarto del Miocardio/complicaciones , Prevención Secundaria/instrumentación , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Cardioversión Eléctrica/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/fisiopatología , Países Bajos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
13.
Europace ; 21(3): 428-433, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30380015

RESUMEN

AIMS: Left atrial appendage closure (LAAC) is increasingly used as an alternative to oral anticoagulation (OAC) for stroke prevention in atrial fibrillation (AF) patients. Feasibility and safety of left atrial (LA) catheter ablation (CA) in patients with previously implanted LAAC devices have not been well studied. We report on the feasibility, safety, and efficacy of LA CA in the presence of a previously implanted LAAC device. METHODS AND RESULTS: In this prospective cohort study consecutive patients that underwent LA CA with a previously implanted Watchman device were included. Periprocedural characteristics and long-term clinical follow-up were evaluated. Twenty-three LA CA procedures were performed in 19/162 AF patients with previously implanted Watchman devices [47% male, age 63.9 ± 6.2 years, CHA2DS2-VASc 4.0 (3.0-5.0); HASBLED 3.0 (2.0-4.0); 63% paroxysmal]. Left atrial CA was performed with irrigated radiofrequency (RF; n = 20, 87%) or phased RF (n = 3, 13%) in a mean of 18 months after LAAC implantation (range 4-80 months). Targets of CA consisted of pulmonary vein isolation (n = 19, 83%), superior vena cava isolation (n = 13, 57%), and additional linear lesions (n = 8, 35%). Procedures were carried out under vitamin K antagonist (VKA; n = 6, 26%), non-VKA OAC (NOAC; n = 8, 35%), or single antiplatelet therapy alone (n = 9, 39%). Left atrial CA was successful without any signs of interference from the device. Procedure-related complications were not observed. During a mean follow-up of 28 months, 11 patients (58%) had AF recurrence. CONCLUSION: Left atrial CA after LAAC appears to be feasible, effective, and safe in this single centre cohort. Previously implanted Watchman device should not be a reason to relinquish CA in symptomatic AF patients, even in patients on single antiplatelet therapy alone.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Ablación por Catéter , Venas Pulmonares/cirugía , Vena Cava Superior/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Ablación por Catéter/efectos adversos , Bases de Datos Factuales , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Vena Cava Superior/fisiopatología
15.
Artículo en Inglés | MEDLINE | ID: mdl-29790185

RESUMEN

INTRODUCTION: Treatment infections is challenging in pacemaker (PM) dependent patients. We proposed a novel implantation strategy for this group of patients. METHODS: Patients who were PM dependent and were admitted with a PM infection received a combined procedure of left ventricular (LV) epicardial implantation of a PM lead and subsequent extraction of the infected system. No temporary pacing wire was used and the PM generator was placed in the left flank. RESULTS: Between 2012 and 2015 we treated 16 patients who were PM dependent and with a PM infection. The majority of patients were male (81% [13/16]) and the median age was 71 years (50-91). The cause of infection was valvular endocarditis in 38% (6/16), lead infection in 25% (4/16), and isolated pocket infection in 38% (6/16). All patients underwent epicardial implantation of a LV lead (1084T bipolar lead; St. Jude Medical Myodex, St. Paul, MN, USA) and extraction of the infected device. There was no occurrence of periprocedural mortality and no postprocedural tamponades. There was one complication in the form of a hemorrhage at the infected device extraction site. In the median follow-up period of 17 months there were four of 16 deaths, none of which were attributable to epicardial LV implantation. LV-lead threshold was 1.1V (±0.7V) upon implantation that increased to 1.2V (±0.6V) at 0.4-ms pulse duration. There were no reinfections of the epicardial lead or device. CONCLUSION: Epicardial left ventricle PM implantation and subsequent extraction of an infected PM in PM-dependent patients is feasible and safe with good long-term outcome.

16.
Pacing Clin Electrophysiol ; 41(10): 1336-1340, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30080928

RESUMEN

BACKGROUND: Atrial tachyarrhythmias are common in patients with cardiac implantable electronic devices (CIEDs). Restoration of sinus rhythm by external electrical cardioversion (eECV) is frequently used to alleviate symptoms and to ensure optimal device function. OBJECTIVES: To evaluate the safety of eECV in patients with contemporary CIEDs and to assess the need for immediate device interrogation after eECV. METHODS: We conducted a retrospective observational study of 229 patients (27.9% female, age 69 ± 10 years) with a CIED (104 pacemakers, 69 implantable cardioverter defibrillators, and 56 biventricular devices) who underwent eECV between 2008 and 2016 in two centers. Data from device interrogation before eECV, immediately afterwards, and at first follow-up (FU) after eECV were collected. CIED-related complications and adverse events during and after eECV were recorded. RESULTS: No significant differences between right atrial (RA) and right ventricular (RV) sensing or threshold values before eECV, immediately afterwards, or at FU were observed. A small yet significant decrease was observed in RA and RV impedance immediately after eECV (484 Ω vs 462 Ω, P < 0.001 and 536 Ω vs 514 Ω, P < 0.001, respectively). The RV impedance did not recover to the baseline value (538 Ω vs 527 Ω, P  =  0.02). The impedance changes were without clinical consequences. No changes in left ventricular lead threshold or impedance values were measured. No CIED-related complications or adverse events were documented following eECV. CONCLUSION: eECV in patients with contemporary CIEDs is safe. There seems to be no need for immediate device interrogation after eECV.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Marcapaso Artificial , Seguridad del Paciente , Anciano , Femenino , Humanos , Masculino , Países Bajos , Estudios Retrospectivos
17.
J Cardiovasc Electrophysiol ; 28(8): 917-923, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28471012

RESUMEN

INTRODUCTION: Optimal left ventricular (LV) lead position in patients undergoing cardiac resynchronization therapy (CRT) is crucial to achieve an optimal effect on hemodynamics. Due to various difficulties, up to 30% of transvenous LV lead placements fail, or a suboptimal position is achieved. Surgical epicardial LV lead placement could be performed at a position anticipated to be the optimal site. This could have a more favorable effect, which may be expressed by increased improvement in left ventricular ejection fraction (LVEF) and cardiac perfusion. The objective of this trial is to compare transvenous versus epicardial LV lead placement in CRT in a randomized fashion METHODS AND RESULTS: Fifty-two patients were randomized to either epicardial or transvenous approach. All patients received an ICD with CRT. Patients were followed for 6 months after device implant. Primary endpoint was the degree of change in cardiac perfusion measured by myocardial perfusion scintigraphy. LVEF equally improved in both groups, from 24% to 36% in the transvenous group versus 25% to 35% in the epicardial group (P = 0.797). Cardiac perfusion, expressed as summed stress score, improved in both groups without a significant difference as well (P = 0.727). Complication rate was similar, respectively 6 and 7 patients had any complication. Admission time was significantly longer in the epicardial group with 2 (2-7) versus 3 (2-32) days (P <0.001). CONCLUSION: Epicardial LV lead placement does not result in additional improvement of LVF or myocardial perfusion compared to the conventional transvenous in CRT.


Asunto(s)
Bloqueo de Rama/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/métodos , Imagen de Perfusión Miocárdica/métodos , Función Ventricular Izquierda/fisiología , Anciano , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/fisiopatología , Estudios Cruzados , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
18.
Pacing Clin Electrophysiol ; 40(6): 741-743, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28326565

RESUMEN

We present the case of a 75-year-old patient with a single-chamber St. Jude Medical internal cardioverter defibrillator (ICD; St. Jude Medical, St. Paul, MN, USA) for primary prevention, who was admitted with 39 inappropriate ICD shocks because of atrial fibrillation with rapid ventricular frequention, despite magnet placement. Review of the device manual and literature revealed that apart from different responses to magnet placement programmed for the various manufacturers, the type of magnet and the positioning can be of specific interest. In the case presented, the donut-shaped magnet should have been placed off-center instead of directly over the device.


Asunto(s)
Fibrilación Atrial/complicaciones , Desfibriladores Implantables/efectos adversos , Traumatismos por Electricidad/etiología , Electrodos Implantados/efectos adversos , Lesiones Cardíacas/etiología , Imanes , Implantación de Prótesis/efectos adversos , Anciano , Traumatismos por Electricidad/prevención & control , Lesiones Cardíacas/prevención & control , Humanos , Masculino , Insuficiencia del Tratamiento , Resultado del Tratamiento
19.
Catheter Cardiovasc Interv ; 88(6): 945-952, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-26946355

RESUMEN

OBJECTIVES: The aim of this study is to assess the long-term effects of alcohol dosage in alcohol septal ablation (ASA) on mortality and adverse arrhythmic events (AAE). BACKGROUND: ASA can be performed to reduce left ventricular outflow tract (LVOT) obstruction in patients with hypertrophic cardiomyopathy (HCM). However, the effect of alcohol dosage on long-term outcomes is unknown. METHODS: This retrospective cohort study includes 296 HCM patients (age 60 ± 22 years, 58% male) who underwent ASA because of symptomatic LVOT obstruction. Twenty-nine patients (9.8%) were excluded because the alcohol dosage could not be retrieved. Primary endpoints were all-cause mortality and AAE. RESULTS: During 6.3 ± 3.7 years of follow-up, all-cause mortality and AAE rates were similar in patients who received ≤2.0 mL (n = 142) and >2.0 mL (n = 121) alcohol during ASA. Age was the only independent predictor of mortality (HR 1.1 95% CI 1.0-1.1, P < 0.001). Predictors of AAE were maximum CK-MB >240 U/L (HR 3.3 95% CI 1.5-7.2, P = 0.003), and sudden cardiac death survivor (HR 5.9 95% CI 1.7-20.3, P = 0.004). There was a mild to moderate correlation between CK-MB levels and amount of alcohol (Spearman's ρ 0.39, P < 0.001), cross-sectional area of the target septal branch ostium/ostia (Spearman's ρ 0.19, P = 0.003), and maximum ventricular wall thickness (Spearman's ρ 0.17, P = 0.006). CONCLUSIONS: Alcohol dosage appears not to have a long-term effect on mortality and AAE. A larger infarct size created by ASA increases the risk of AAE, and extended monitoring of these patients is advised. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Técnicas de Ablación/métodos , Cardiomiopatía Hipertrófica/terapia , Etanol/administración & dosificación , Tabiques Cardíacos , Obstrucción del Flujo Ventricular Externo/terapia , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Ecocardiografía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico , Obstrucción del Flujo Ventricular Externo/etiología
20.
Pacing Clin Electrophysiol ; 39(3): 307-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26548562

RESUMEN

A 53-year-old female patient with hypertrophic obstructive cardiomyopathy (HOCM) was admitted for alcohol septal ablation (ASA). A subcutaneous internal cardioverter defibrillator (S-ICD) was implanted for primary prevention. After ASA, the patient developed a right bundle branch block, and the S-ICD delivered a total of five inappropriate shocks due to T-wave oversensing (TWOS). TWOS is a relatively frequent cause of inappropriate shocks in S-ICD patients. After invasive treatment for HOCM, there is a risk of developing intraventricular conduction delay and subsequent changes in QRS and T-wave morphology. This should be taken into consideration when ICD indication is evaluated in HOCM patients.


Asunto(s)
Técnicas de Ablación/métodos , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/terapia , Desfibriladores Implantables/efectos adversos , Traumatismos por Electricidad/etiología , Etanol/uso terapéutico , Cardiomiopatía Hipertrófica/diagnóstico , Terapia Combinada/efectos adversos , Terapia Combinada/métodos , Traumatismos por Electricidad/diagnóstico , Traumatismos por Electricidad/prevención & control , Femenino , Tabiques Cardíacos/cirugía , Humanos , Persona de Mediana Edad , Resultado del Tratamiento