Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(20): 1831-1839, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38740526

RESUMEN

BACKGROUND AND AIMS: Arrhythmic mitral valve prolapse (AMVP) is linked to life-threatening ventricular arrhythmias (VAs), and young women are considered at high risk. Cases of AMVP in women with malignant VA during pregnancy have emerged, but the arrhythmic risk during pregnancy is unknown. The authors aimed to describe features of women with high-risk AMVP who developed malignant VA during the perinatal period and to assess if pregnancy and the postpartum period were associated with a higher risk of malignant VA. METHODS: This retrospective international multi-centre case series included high-risk women with AMVP who experienced malignant VA and at least one pregnancy. Malignant VA included ventricular fibrillation, sustained ventricular tachycardia, or appropriate shock from an implantable cardioverter defibrillator. The authors compared the incidence of malignant VA in non-pregnant periods and perinatal period; the latter defined as occurring during pregnancy and within 6 months after delivery. RESULTS: The authors included 18 women with AMVP from 11 centres. During 7.5 (interquartile range 5.8-16.6) years of follow-up, 37 malignant VAs occurred, of which 18 were pregnancy related occurring in 13 (72%) unique patients. Pregnancy and 6 months after delivery showed increased incidence rate of malignant VA compared to the non-pregnancy period (univariate incidence rate ratio 2.66, 95% confidence interval 1.23-5.76). CONCLUSIONS: The perinatal period could impose increased risk of malignant VA in women with high-risk AMVP. The data may provide general guidance for pre-conception counselling and for nuanced shared decision-making between patients and clinicians.


Asunto(s)
Prolapso de la Válvula Mitral , Complicaciones Cardiovasculares del Embarazo , Humanos , Femenino , Embarazo , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/epidemiología , Estudios Retrospectivos , Adulto , Complicaciones Cardiovasculares del Embarazo/epidemiología , Factores de Riesgo , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Trastornos Puerperales/epidemiología , Trastornos Puerperales/etiología , Desfibriladores Implantables , Incidencia , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/etiología , Periodo Posparto
2.
Cardiovasc Diabetol ; 22(1): 77, 2023 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-37004023

RESUMEN

BACKGROUND: Diabetes mellitus (DM) type 2 is an independent risk factor for atrial fibrillation (AF). Surgical ablation or "maze procedure" is an option for patients with AF undergoing concomitant or isolated cardiac surgery. The aim of this study was to evaluate the impact of DM type 2 on early and long-term outcomes of patients following surgical AF ablation. METHODS: We performed an observational cohort study in Israel's largest tertiary care center. All data of patients who underwent surgical AF ablation, between 2006 and 2021 were extracted from our departmental database. Patients were divided into Group I (non-diabetic patients) and Group II (DM type 2 patients). We compared the two groups with respect to freedom from recurrent atrial arrhythmia, and mortality rate. RESULTS: The study population included 606 patients. Group I (non-DM patients), consisting of 484 patients, and Group II (DM type 2 patients), comprised 122 patients. Patients with DM were older, had more hypertension and incidence of cerebrovascular accident (CVA)/transient ischemic attack (TIA), higher EuroSCORE (p < .05 for all), and a longer bypass time-130 ± 40 vs. 122 ± 36 min (p = 0.028). The mean follow-up duration was 39.0 ± 22.7 months. Freedom from atrial fibrillation was similar between the non-DM and DM type 2 groups after a 1-year follow-up, 414 (88.2%) vs. 101 (87.1%) (p = 0.511), after a 3-year follow-up, 360 (86.3%) vs. 84 (79.9%) (p = 0.290) and after a 5-year follow-up, 226 (74.1%) vs. 55 (71.5%) (p = 0.622) respectively. Furthermore, 1- and 3-year mortality was similar between non-DM and DM type 2 groups, 2.5% vs. 4.9%, (p = 0.226) and 5.6% vs. 10.5% (p = 0.076) respectively. 5-year mortality was higher in Group II (DM type 2 patients) compared with Group I (non-DM patients), 11.1% vs. 23.4% (p = 0.009). CONCLUSION: Surgical ablation had a high success rate, with freedom from recurrent atrial arrhythmia at 1- 3- and 5- years follow-up in both the DM type 2 and non-DM groups. Furthermore,1- and 3-year mortality after surgical ablation was also similar in both groups. However, 5-year mortality was higher in the DM type 2 group.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Diabetes Mellitus Tipo 2 , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico , Factores de Riesgo , Procedimientos Quirúrgicos Cardíacos/efectos adversos
3.
Europace ; 25(3): 956-960, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36636968

RESUMEN

AIMS: Intraoperative defibrillation testing (DT) during implant or replacement of implantable cardioverter-defibrillators (ICDs) has been a matter of debate for many years. This debate was put to rest by the Simple and Nordic ICD trials, and the practice of testing during new implantations has essentially been almost abandoned. Old registries demonstrated an increased incidence of significant findings in DT during replacements. The aim of the present study was to evaluate frequency of significant findings and safety of DT in subjects undergoing device replacement. METHODS AND RESULTS: A prospective observational multi-centre study included consecutive patients undergoing ICD generator replacement. The primary outcome was a failure to terminate induced ventricular fibrillation (VF) with a single shock 10 J below the maximal capacity of the device. Secondary outcomes included complications of DT. Patients were followed-up at 1- and 6-months post-procedure. A total of 92 patients were eligible, and consented to the study, of which 84 underwent DT during battery replacement. The median age was 68 years and 79.8% were males. Induction of VF was successful in 84 patients as was a successful conversion on the first attempt in all. There were no procedure-related complications. During follow up one patient had two appropriate ICD shock events. In four patients, ICD programming was changed. None suffered inappropriate shock. There was no evidence of lead malfunction. Two deaths occurred, none of which was related to arrhythmia. CONCLUSION: The present study found DT was not associated with complications in patients undergoing ICD generator replacement but produced no clinically important information.


Asunto(s)
Desfibriladores Implantables , Masculino , Humanos , Anciano , Femenino , Desfibriladores Implantables/efectos adversos , Arritmias Cardíacas/etiología , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia
4.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37695316

RESUMEN

AIMS: Several studies have evaluated the use of electrically- or imaging-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT) recipients. We aimed to assess evidence for a guided strategy that targets LV lead position to the site of latest LV activation. METHODS AND RESULTS: A systematic review and meta-analysis was performed for randomized controlled trials (RCTs) until March 2023 that evaluated electrically- or imaging-guided LV lead positioning on clinical and echocardiographic outcomes. The primary endpoint was a composite of all-cause mortality and heart failure hospitalization, and secondary endpoints were quality of life, 6-min walk test (6MWT), QRS duration, LV end-systolic volume, and LV ejection fraction. We included eight RCTs that comprised 1323 patients. Six RCTs compared guided strategy (n = 638) to routine (n = 468), and two RCTs compared different guiding strategies head-to-head: electrically- (n = 111) vs. imaging-guided (n = 106). Compared to routine, a guided strategy did not significantly reduce the risk of the primary endpoint after 12-24 (RR 0.83, 95% CI 0.52-1.33) months. A guided strategy was associated with slight improvement in 6MWT distance after 6 months of follow-up of absolute 18 (95% CI 6-30) m between groups, but not in remaining secondary endpoints. None of the secondary endpoints differed between the guided strategies. CONCLUSION: In this study, a CRT implantation strategy that targets the latest LV activation did not improve survival or reduce heart failure hospitalizations.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Ecocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Hospitalización
5.
Eur Heart J ; 43(47): 4912-4919, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36148481

RESUMEN

AIMS: Anti-Ro/La autoantibodies are especially prevalent in autoimmune diseases but are also relatively frequent in healthy adults. Their arrhythmogenic effect on the immature cardiac conductive system is well established, with substantial evidence demonstrating an increased risk for congenital atrioventricular block in neonates of seropositive mothers. Despite their wide distribution and their arrhythmogenic potential effect, there are no large population studies conducted in seropositive adults. Thus, this is the first large population-based study to examine the association of anti-Ro/La seropositivity with cardiac rhythm and conduction disturbances. METHODS AND RESULTS: This cross-sectional designed study involved the electronic health records of the largest health maintenance organization in Israel. All subjects that were tested positive for anti-Ro/anti-La antibodies between the years 2002 and 2019 were included and were matched by age, gender, and place of residence, with controls. Rates of different cardiac rhythm and conduction disturbances were compared between groups. Sensitivity analyses were performed using propensity score matching. The study population included 17 231 anti-Ro/La seropositive subjects and 84 368 controls. Anti-Ro seropositive patients had higher rates of conduction disturbances (3.0 vs. 1.7%, P < 0.001) and rhythm disturbances (10.5 vs. 7.0%, P < 0.001). Patients who tested positive for anti-La alone did not demonstrate a significant association with arrhythmias. Multivariate logistic regression analysis, controlling for possible confounders, showed an increased risk for cardiac conduction disturbances [odds ratio (OR) 1.44, 95% confidence interval (CI) 1.25-1.66, P < 0.001], as well as for cardiac rhythm disturbances (OR 1.21, 95% CI 1.11-1.31, P < 0.001) among anti-Ro seropositive patients. However, the association with rhythm disturbances was more robust in certain subgroup analyses. CONCLUSIONS: Anti-Ro seropositivity is positively associated with adult cardiac conduction disturbances and, to a lesser extent, cardiac rhythm disturbances, regardless of the presence of concurrent autoimmune disease.


Asunto(s)
Enfermedades Autoinmunes , Sistema de Conducción Cardíaco , Recién Nacido , Adulto , Humanos , Estudios Transversales , Arritmias Cardíacas/epidemiología , Fenómenos Fisiológicos Cardiovasculares , Autoanticuerpos
6.
Europace ; 24(4): 598-605, 2022 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-34791165

RESUMEN

AIM: To describe clinical characteristics, procedural details, specific challenges, and outcomes in patients with HeartMate3™ (HM3), a left ventricular assist device system with a magnetically levitated pump, undergoing ventricular tachycardia ablation (VTA). METHODS AND RESULTS: Data were collected from patients with an HM3 system who underwent VTA in seven tertiary centres. Data included baseline patient characteristics, procedural data, mortality, and arrhythmia-free survival. The study cohort included 19 patients with cardiomyopathy presenting with ventricular tachycardia (VT) (53% with VT storm). Ventricular tachycardias were induced in 89% of patients and a total of 41 VTs were observed. Severe electromagnetic interference was present on the surface electrocardiogram. Hence, VT localization required analysis of intra-cardiac signals or the use of filter in the 40-20 Hz range. The large house pump HM3 design obscured the cannula inflow and therefore multi imaging modalities were necessary to avoid catheter entrapment in the cannula. A total of 32 VTs were mapped and were successfully ablated (31% to the anterior wall, 38% to the septum and only 9% to the inflow cannula region). Non-inducibility of any VT was reached in 11 patients (58%). Over a follow-up of 429 (interquartile range 101-692) days, 5 (26%) patients underwent a redo VT ablation due to recurrent VTA and 2 (11%) patients died. CONCLUSIONS: Ventricular tachycardia ablation in patients with HM3 is feasible and safe when done in the appropriate setup. Long-term arrhythmia-free survival is acceptable but not well predicted by non-inducibility at the end of the procedure.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Corazón Auxiliar , Taquicardia Ventricular , Cardiomiopatías/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Recurrencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
7.
Europace ; 24(5): 835-844, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-34734227

RESUMEN

AIMS: To evaluate the benefit of speckle tracking radial strain imaging (STRSI)-guided left ventricular (LV) lead (LVL) positioning in cardiac resynchronization therapy (CRT) in patients (pts) with ischaemic cardiomyopathy with CRT indication. METHODS AND RESULTS: We conducted a prospective randomized controlled trial. Patients were enrolled in nine centres with 2:1 randomization into two groups (guided vs. control). Patients underwent STRSI to identify the optimal LV position from six LV segments at midventricular level. Implantation via STRSI was attempted for recommended segment in the guided group only. Follow-up included echocardiography (6 months) and clinical evaluation (6 and 12 months). The primary endpoint was comparison % reduction in LV end-systolic volume at 6 months with baseline. Secondary endpoints included hospitalizations for heart failure and death, and improvement in additional echocardiographic measurements and quality of life score. A total of 172 patients (115 guided vs. 57 control) were enrolled. In the guided group, 60% of the implanted LV leads were adjudicated to be successfully located at the recommended segment, whereas in the control group 44% reached the best STRSI determined segment. There was no difference between the groups in any of the primary or secondary endpoints at 6 and 12 months. CONCLUSION: Our findings suggest that echo-guided implantation of an LV lead using STRSI does not improve the clinical or echocardiographic response compared with conventional implantation.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatías , Insuficiencia Cardíaca , Isquemia Miocárdica , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/terapia , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/terapia , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento
8.
Europace ; 24(2): 285-295, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34491328

RESUMEN

AIMS: In arrhythmogenic cardiomyopathy (ACM), sustained ventricular tachycardia (VT) typically displays a left bundle branch block (LBBB) morphology while a right bundle branch block (RBBB) morphology is rare. The present study assesses the VT morphology in ACM patients with sustained VT and their clinical and genetic characteristics. METHODS AND RESULTS: Twenty-six centres from 11 European countries provided information on 954 ACM patients who had ≥1 episode of sustained VT spontaneously documented during patients' clinical course. Arrhythmogenic cardiomyopathy was defined according to the 2010 Task Force Criteria, and VT morphology according to the QRS pattern in V1. Overall, 882 (92.5%) patients displayed LBBB-VT alone and 72 (7.5%) RBBB-VT [alone in 42 (4.4%) or in combination with LBBB-VT in 30 (3.1%)]. Male sex prevalence was 79.3%, 88.1%, and 56.7% in the LBBB-VT, RBBB-VT, and LBBB + RBBB-VT groups, respectively (P = 0.007). First RBBB-VT occurred 5 years after the first LBBB-VT (46.5 ± 14.4 vs 41.1 ± 15.8 years, P = 0.011). An implanted cardioverter-defibrillator was more frequently implanted in the RBBB-VT (92.9%) and the LBBB + RBBB-VT groups (90%) than in the LBBB-VT group (68.1%) (P < 0.001). Mutations in PKP2 predominated in the LBBB-VT (65.2%) and the LBBB + RBBB-VT (41.7%) groups while DSP mutations predominated in the RBBB-VT group (45.5%). By multivariable analysis, female sex was associated with LBBB + RBBB-VT (P = 0.011) while DSP mutations were associated with RBBB-VT (P < 0.001). After a median follow-up of 103 (51-185) months, death occurred in 106 (11.1%) patients with no intergroup difference (P = 0.176). CONCLUSION: RBBB-VT accounts for a significant proportion of sustained VTs in ACM. Sex and type of pathogenic mutations were associated with VT type, female sex with LBBB + RBBB-VT, and DSP mutation with RBBB-VT.


Asunto(s)
Cardiomiopatías , Taquicardia Ventricular , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Bloqueo de Rama/terapia , Cardiomiopatías/complicaciones , Cardiomiopatías/epidemiología , Cardiomiopatías/genética , Electrocardiografía , Femenino , Humanos , Masculino , Prevalencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/genética
9.
Clin J Sport Med ; 32(1): e104-e105, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34446650

RESUMEN

ABSTRACT: A 17-year-old elite triathlete presented with recurrent loss of consciousness events. Implantable loop recorder (ILR) documented sinus node asystoles of up to 21 seconds. She underwent cardiac neuromodulation ablation. After ablation, a generalized tonic-clonic seizure (GTCS) occurred, without concomitant asystole on the ILR. Temporal lobe seizures were diagnosed and supported by interictal epileptic activity on electroencephalogram. We assumed that the syncope episodes were ictal asystole (IA) and that the IA terminated the epileptic seizures early after their onset. The cardiac ablation prevented IA, enabling spread of seizure activity and development of GTCS. To the best of our knowledge, this is the first case of IA treated with cardiac ablation, allowing avoidance of cardiac pacing. This case raises the awareness to epileptic seizures as a cause of asystole in athletes, with an elusive and atypical presentation.


Asunto(s)
Electrocardiografía , Síncope , Adolescente , Atletas , Encéfalo , Electricidad , Femenino , Humanos , Síncope/diagnóstico , Síncope/etiología
10.
Catheter Cardiovasc Interv ; 98(7): E990-E999, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34347381

RESUMEN

OBJECTIVES: This study aimed to compare permanent pacemaker implantation (PPMI) rates among patients undergoing Trans-catheter Aortic Valve Implantation (TAVI) with first generation (G1) versus second generation (G2) valves and the impact of PPMI on long-term mortality. BACKGROUND: PPMI is a known adverse event after TAVI. Recently, two novel iterations of valve designs of both the balloon expandable valves (BEV) and self-expanding valves (SEV) were introduced as a second generation valves. METHODS: All patients included in the Israeli multicenter TAVI registry were grouped according to valve type (BEV vs. SEV) and generation (G1 vs. G2). A comparison was made for clinical and outcome indices of patients undergoing TAVI with G1 and G2 in each of the valve systems. RESULTS: A total of 1377 patients were included. The incidence of PPMI did not differ between G1-BEV versus G2-BEV (15.3% vs. 17.4%; p = 0.598) nor between G1-SEV versus G2-SEV (23.4% vs. 20.3%; p = 0.302). Depth of implantation and complete right bundle branch block were independently associated with PPMI post-TAVI in both valve systems. PPMI was not associated with an increased risk for 2-year mortality. CONCLUSIONS: The incidence of PPMI remains a relevant adverse event post-TAVI even when the newer generation valves are used. Since the predictors for PPMI are well established, a standardized approach for the management of conduction disorders is much needed.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
11.
J Cardiovasc Electrophysiol ; 31(5): 1155-1162, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32141635

RESUMEN

BACKGROUND: The prognosis of patients with untreated cardiac implantable electronic device (CIED) infection is poor. Whether removal of all leads by a successful transvenous lead extraction (TLE) procedure changes the prognosis is unclear. OBJECTIVE: To identify predictors of mortality in patients with CIED infection despite successful TLE. METHODS: Retrospective single-center analysis of prospectively collected database from consecutive patients undergoing TLE at our center. Predictors for mortality were identified and a score predicting high mortality rate was calculated. RESULTS: A total of 371 consecutive patients underwent TLE, of whom 337 (90.8%) had complete hardware removal. Most were extracted due to infectious causes (81.3%). Approximately one-third (35%) died during a mean follow-up of 1056 ± 868 days. There was significantly higher mortality observed in the infectious group. Multivariate logistic regression models for infectious group only identified creatinine and albumin measurements as risk markers for 30 days mortality (odds ratio [OR], 1.68; 95% confidence interval [CI], 1.19-2.38; P = .003 and OR, 0.4; 95% CI, 0.16-0.97; P = .039, respectively). A risk score was created based on cutoff values of creatinine ≥2md/dL (1 point) and albumin ≤3.5 g/dL (1 point). A value of 2 points predicted a 50% chance of 30-day mortality and a 75% chance of 1-year mortality (P < .0001 for both). CONCLUSIONS: Creatinine and albumin can be used as a combined risk score to successfully identify patients at risk of death despite undergoing a successful TLE procedure for infectious reasons. This score could help decision making when contemplating on conservative antibiotic treatment vs TLE.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Marcapaso Artificial/efectos adversos , Falla de Prótesis , Infecciones Relacionadas con Prótesis/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Creatinina/sangre , Bases de Datos Factuales , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/mortalidad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Albúmina Sérica Humana/análisis , Factores de Tiempo , Resultado del Tratamiento
12.
Infection ; 48(4): 635-640, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32246271

RESUMEN

Heart transplantation (HT) in patients with prior cardiovascular implantable electronic devices (CIEDs) is becoming more common, in parallel with the increased use of CIEDs for patients with advanced heart failure. Complete removal of CIED components during HT is not always feasible, and it is thus surprising that the literature addressing the implications of retained CIED components is limited. Indeed, there are neither guidelines nor consensus regarding the need for removal of these CIED fragments. This issue is nonetheless becoming important in light of the increase in the percentage of HT candidates having CIEDs, on the one hand, and newer therapeutic immunosuppressive protocols with higher bacterial infection potential, on the other. Thus, with the aim to study the implications of retained CIED fragments as a step towards establishing a therapeutic approach for the unique population of HT recipients with CIED remnants, we present here a case series of HT patients with retained CIED fragments who developed complications of infections together with a review of the available literature.


Asunto(s)
Trasplante de Corazón/efectos adversos , Marcapaso Artificial/efectos adversos , Complicaciones Posoperatorias/etiología , Femenino , Trasplante de Corazón/instrumentación , Humanos , Masculino , Persona de Mediana Edad
13.
Europace ; 22(2): 281-287, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31942613

RESUMEN

AIMS: To explore the association between resting heart rate (RHR) and ventricular tachyarrhythmias (VTA) events among patients who were enrolled in MADIT-RIT. METHODS AND RESULTS: Multivariate Cox proportional hazards regression modelling was employed to evaluate the association between baseline RHR [dichotomized at the lower quartile (≤63 b.p.m.) and further assessed as a continuous measure] and the risk for any VTA, fast VTA (>200 b.p.m.), and appropriate implantable cardioverter-defibrillator (ICD) therapy, among 1500 patients who were enrolled in MADIT-RIT. Kaplan-Meier survival analysis showed that at 2 years of follow-up the rate of any VTA was significantly lower among patients with low baseline RHR (≤63 b.p.m.) as compared with faster RHR (11% vs. 19%, respectively; P = 0.001 for the overall difference during follow-up). Similar results were shown for the association with the rate of fast VTA (8% vs. 14%, respectively; P = 0.016), and appropriate ICD therapy (10% vs. 18%, respectively; P = 0.004). Multivariate analysis, after adjustment for medical therapy, showed that low baseline RHR was associated with a significant 45% (P = 0.002) reduction in the VTA risk as compared with faster baseline RHRs. When assessed as a continuous measure, each 10 b.p.m. decrement in RHR was associated with a corresponding 13% (P = 0.014) reduction in the VTA risk. CONCLUSION: In MADIT-RIT, low RHR was independently associated with a lower risk for life-threatening arrhythmic events. These findings suggest a possible role for RHR for improved selection of candidates for ICD therapy.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/terapia , Resultado del Tratamiento
14.
Indian Pacing Electrophysiol J ; 20(4): 137-140, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31862483

RESUMEN

PURPOSE: The Biotronik LinoxSmart DX implanted cardioverter defibrillator (ICD) lead is a novel VDD lead with the advantage of integrated atrial sensing dipole combined with a special augmentation and filtering mechanisms. We sought to determine the efficacy of the Biotronik LinoxSmart DX ICD lead. METHODS: Non-randomized consecutive patients implanted with Biotronik LinoxSmart DX lead at Sheba Medical Center were included in this study. Electrical parameters and arrhythmic events were recorded during follow up of one year. RESULTS: Seventy-three patients (69 males (94.5%), mean age 61 ± 12 years) were included. All patients were successfully implanted with a Biotronic VR-T DX device and LinoxSmart DX ICD lead (DX-17 in 37% and DX-15 in 63% patients). Mean P wave amplitude at time of implantation was 3.66 ± 2.9 mV and improved significantly throughout the follow-up (5.29 ± 4.39 mV, p = 0.009). Appropriate atrial sensing (defined as P wave amplitude of ≥0.8 mV) rate of 100% at implantation significantly decreased to 89% (p = 0.015) at 12 months. Three out of 67 (4.5%) patients without a known history of atrial fibrillation had documented new onset paroxysmal atrial fibrillation. Appropriate shocks occurred in 4 (5.5%) patients. One patient with atrial sensing less than 0.4 mV had inappropriate shock. CONCLUSIONS: Among patients implanted with the Biotronik LinoxSmart DX ICD lead in our single center, appropriate atrial sensing rate decreased over 12 months. Larger studies are needed to evaluate the reliability of long term appropriate atrial sensing.

15.
Catheter Cardiovasc Interv ; 93(7): 1361-1366, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30489692

RESUMEN

OBJECTIVE: To evaluate the efficacy and safety of periprocedural beta-blocker (BB) discontinuation among patients undergoing transcatheter aortic valve replacement (TAVR) and high degree atrioventricular block (HD-AVB) and/or atrial fibrillation (AF). METHODS: The study population comprised 743 consecutive patients who underwent TAVR between 2009 and 2017 in two high-volume tertiary centers. All patients received chronic BB therapy, and were divided into two groups: (1) BB continuation and (2) BB discontinued 24 hr prior to the procedure. The primary endpoint was the development of composite brady and tachy-arrhytmic events (including HD-AVB and/or NOAF) following the procedure. RESULTS: Among 743 study patients, 366 (49%) continued BB prior to the procedure and in 377 (51%) chronic BB therapy was discontinued. The rate of the composite periprocedural arrhythmic event was significantly higher among patients who stopped BB (20% vs. 13%, respectively, P = 0.018). Consistently, multivariate analysis showed that discontinuation of BB was associated with two-fold (P = 0.003) increase in the risk for periprocedural arrhythmic events (OR = 2.0; 95% CI 1.24-3.23; P = 0.004). The association between BB discontinuation and periprocedural arrhythmic events was consistent for the separate endpoints for HDAV and NOAF. Furthermore, the need for permanent pacemaker was significantly higher among patients who discontinued BB (20% vs. 13%; P = 0.018, respectively). CONCLUSIONS: Among patients undergoing TAVR who receive chronic BB therapy, BB discontinuation prior to the procedure is independently associated with a significant increase in the rate of adverse arrhythmic events, including HDAVB, NOAF, and the need for pacemaker implantation.


Asunto(s)
Antagonistas Adrenérgicos beta/administración & dosificación , Estenosis de la Válvula Aórtica/cirugía , Fibrilación Atrial/etiología , Bloqueo Atrioventricular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial , Esquema de Medicación , Femenino , Humanos , Israel , Masculino , Marcapaso Artificial , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
16.
Europace ; 21(11): 1639-1645, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31390461

RESUMEN

AIMS: To validate the utility of CHA2DS2-VASc score to predict the annual risk of stroke in patients admitted with acute heart failure, comparing those with preserved ejection fraction (HF-presEF) and reduced ejection fraction (HF-redEF). METHODS AND RESULTS: We investigated 2922 patients with known atrial fibrillation who were admitted to the Sheba Medical Center for acute decompensated heart failure (HF). Anticoagulation therapy was prescribed based on CHA2DS2-VASc score or physician's discretion. Subjects were divided into four pre-specified groups based on HF type and median CHA2DS2-VASc score: HF-presEF with CHA2DS2-VASc <5(N = 731), HF-presEF with CHA2DS2-VASc ≥5 (N = 1102), HF-redEF with CHA2DS2-VASc <5 (N = 563), and HF-redEF with CHADS2-VASc ≥5 (N = 526). The primary endpoint was an ischaemic stroke at 1 year. Mean age of the study population was 79 ± 11 years, of whom more than half were women. The median CHA2DS2-VASc score for the entire study population was 5.0 (interquartile range 25-75%: 4-6). Stroke rate for the entire study population was 6.6%. Multivariate Cox regression proportional hazards regression analysis revealed that in both HF-redEF and HF-presEF patients, each one-point increment in CHA2DS2-VASc was associated with a corresponding 28% increase in stroke risk (P < 0.001). The Kaplan-Meier's survival analysis revealed that in the same CHADS2-VASc category (high vs. low), no difference was found between HF-redEF and HF-presEF with regards to the risk of stroke. CONCLUSION: Our key finding is that the CHA2DS2-VASc score is a valid and powerful predictor of subsequent stroke among patients admitted with acute heart failure decompensation regardless of heart failure type.


Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Medición de Riesgo/métodos , Volumen Sistólico/fisiología , Accidente Cerebrovascular/diagnóstico , Enfermedad Aguda , Anciano , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Israel/epidemiología , Masculino , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología
17.
Europace ; 21(5): 690-697, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30843036

RESUMEN

Atrial fibrillation (AF), is the most common sustained arrhythmia and is associated with a substantial increase in morbidity and mortality. Several studies have demonstrated sex-related differences in various aspects, including age at diagnosis, clinical manifestations, management and prognosis. These dissimilarities may dictate different approaches to management and could translate to differences in outcomes. However, similarly to other cardiovascular therapies, there may be a tendency to treat females more conservatively and less aggressively than male patients. The use of oral anticoagulants, for example, is lower in female patients with AF. Electrical cardioversion is less often used. Likewise, despite higher rates of adverse reactions to antiarrhythmic drugs in women, they are less likely to undergo catheter ablations, a well-established therapeutic approach to symptomatic patients with recurrences of AF. In this article, we review sex related dissimilarities in patients with AF. In addition, we discuss various treatment options, and specifically refer to differences in access of treatment, success rates, and potential treatment-related complications.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Técnicas de Ablación , Antiarrítmicos/uso terapéutico , Cardioversión Eléctrica , Femenino , Accesibilidad a los Servicios de Salud , Frecuencia Cardíaca , Humanos , Masculino , Factores Sexuales
18.
Europace ; 21(3): 459-464, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30689821

RESUMEN

AIMS: Heart failure patients with advanced chronic kidney disease (CKD) may experience an increased rate of non-arrhythmic mortality due to associated comorbidities. We aimed to evaluate the risk of mortality without appropriate implantable cardioverter-defibrillator (ICD) shocks in this high-risk population. METHODS AND RESULTS: The study population comprised 3542 patients who received an ICD, were enrolled, and prospectively followed-up in the Israeli ICD registry. Study patients were categorized into two groups: those with advanced CKD [defined by a glomerular filtration rate of <30 mL/min/1.73 m2 or being on dialysis at time of implantation (n = 197)], and those without advanced CKD (n = 3344). The primary endpoint was the risk of death without receiving appropriate ICD shock. Kaplan-Meier survival analysis showed that at 5 years of follow-up the rates of death without prior ICD shock were significantly higher in the advanced kidney disease group (46%) compared with the non-advanced CKD group (19%; log-rank P-value <0.001). Consistently, multivariate analysis showed that the risk of death without receiving appropriate ICD shock therapy at 5 years was 2.5-fold (P < 0.001) higher among advanced CKD patients. In contrast, the rate of appropriate ICD shock therapy at 5 years among advanced CKD patients was only 9%, with a very high mortality rate (63%) within 3.5 years subsequent to shock therapy. CONCLUSION: Nearly one-half of ICD with advanced CKD die within 5 years without receiving an appropriate ICD shock. These findings stress the importance of appropriate patient selection for primary ICD implantation in this high-risk population.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Tasa de Filtración Glomerular , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Riñón/fisiopatología , Insuficiencia Renal Crónica/mortalidad , Anciano , Toma de Decisiones Clínicas , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Israel , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Diálisis Renal , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/terapia , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
Europace ; 21(12): 1843-1850, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31647531

RESUMEN

AIMS: There are limited data regarding factors that identify implantable cardioverter-defibrillator (ICD) patients who will experience either ventricular tachyarrhythmic (VTA) or non-arrhythmic (NA) mortality, and the commonly used clinical classification of sudden cardiac death (SCD) vs. non-sudden cardiac death (NSCD) may not be accurate enough. We aimed to correlate clinical adjudication of mortality events to device interrogation data and to identify risk factors for VTA mortality in Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II). METHODS AND RESULTS: Of the 746 patients who received an ICD in MADIT-II, 44 died from cardiac causes and had available interrogation data at the time of death. Sudden cardiac death vs. NSCD was defined by an adjudication committee. Ventricular tachyarrhythmic and NA arrhythmic deaths were categorized by the presence or absence of ventricular tachycardia or fibrillation (VT/VF) during the terminal event. Mode of death was found to be inaccurate when validated by device interrogation for VTA events: 50% patients adjudicated as SCD did not have a VTA event at the time of death; and 25% of adjudicated NSCD were found to have VT/VF during the mortality event. Multivariate analysis showed that factors independently associated with VTA mortality included: VT/VF >72 h prior to the mortality event [hazard ratio (HR) 8.0; P < 0.001], hospitalization for heart failure (HR 6.7; P = 0.001), and a history of hypertension (HR 4; P = 0.04). CONCLUSION: Current classification of SCD vs. NSCD fails to identify VTA events at the time of death in a significant proportion of patients, and simple clinical parameters can be used to identify ICD recipients with increased risk for VTA mortality.


Asunto(s)
Bradicardia/mortalidad , Desfibriladores Implantables , Paro Cardíaco/mortalidad , Taquicardia Ventricular/mortalidad , Fibrilación Ventricular/mortalidad , Anciano , Causas de Muerte , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica/estadística & datos numéricos , Femenino , Humanos , Masculino , Mortalidad , Modelos de Riesgos Proporcionales
20.
Europace ; 21(12): 1876-1889, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31625553

RESUMEN

AIMS: The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved. METHODS AND RESULTS: ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (<4 cm of lead left) in 88 (4.7%), and failed (>4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08-1.19), P < 0.0001 and OR 2.68 (1.22-5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04-0.95), P = 0.03 and OR 0.32 (0.13-0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01-4.16), P = 0.046]. CONCLUSION: A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Remoción de Dispositivos/estadística & datos numéricos , Marcapaso Artificial , Infecciones Relacionadas con Prótesis/terapia , Factores de Edad , Anciano , Antibacterianos/uso terapéutico , Electrodos Implantados , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Tiempo , Insuficiencia del Tratamiento , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA