RESUMEN
Percutaneous transendocardial injections of therapeutic agents into the myocardium may not always be effective. We used an animal model for assessing the efficacy of the injections using linoleic acid as a testing agent. Efficacious delivery into the myocardium of a beating heart was indicated by rapidly developed local myocardial necrosis and wall motion abnormalities using echocardiography. We employed this experimental model to test our innovative technology, an acoustically active injection catheter. The Doppler ultrasound-guided acoustically active injection catheter effectively delivers the substance to the myocardium but needs further technical improvements to minimize an unwanted systemic distribution of the agent.
Asunto(s)
Cateterismo Cardíaco , Catéteres , Animales , Modelos Animales de Enfermedad , Inyecciones , Ultrasonografía DopplerRESUMEN
B-mode ultrasound imaging guidance of cannulas can be compromised by noise, artifacts, and echogenicity that is not distinctive from that of surrounding anatomy. We have modified a venovenous extracorporeal membrane oxygenation cannula by embedding piezoelectric crystals into each of its 3 blood flow ports. Each vibrating crystal acoustically interacts with a Doppler imaging signal and produces an instantaneous color marker. The aim of this study was to compare identification of the extracorporeal membrane oxygenation cannula ports by B-mode imaging versus the color Doppler marker. Unlike B-mode imaging, the color Doppler marker identified the corresponding port even in highly challenging closed-chest scans in anesthetized pigs. The method could improve guidance accuracy of cannulas by ultrasound scans.
Asunto(s)
Oxigenación por Membrana Extracorpórea/instrumentación , Ultrasonografía Doppler en Color , Ultrasonografía Intervencional/métodos , Animales , Diseño de Equipo , PorcinosRESUMEN
Opening a chest in an experimental echocardiographic animal study eliminates ultrasound signal attenuation by the chest wall. We developed a scanning technique that involves the use of an attenuative pad created from a mixture of urethane and titanium dioxide. The pad was interposed within transmission gel between the transducer face and cardiac surface in open-chest scans in a porcine model. Comparative measurements of left ventricular echogenicity without and with the pad demonstrate that the pad reproducibly causes ultrasound signal attenuation that closely mimics chest attenuation in clinical transthoracic echocardiographic studies.
Asunto(s)
Ecocardiografía/instrumentación , Ecocardiografía/métodos , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Animales , Geles , Modelos Animales , Reproducibilidad de los Resultados , Porcinos , Titanio , Transductores , UretanoRESUMEN
OBJECTIVES: Left ventricular (LV) septal hypertrophy in aortic stenosis raises diagnostic and therapeutic questions. However, the etiology and clinical consequences of this finding have not been well studied. The aim of this study was to perform a morphologic evaluation of the LV in aortic stenosis and to investigate the contributing factors and consequences of septal hypertrophy. METHODS: Patients with moderate or severe aortic stenosis were prospectively enrolled. Patients with previous myocardial infarction, wall motion abnormalities, at least moderate valvular regurgitation, known cardiomyopathy, an LV ejection fraction of less than 50%, and age younger than 65 years were excluded. RESULTS: Forty-one patients underwent a final analysis. Septal hypertrophy (LV septal wall thickness ≥15 mm) was confirmed in 21 of 41 patients. The septal hypertrophy group had higher peak aortic valve velocity, a higher diabetes mellitus rate, and a higher rate and longer duration of hypertension than those without septal hypertrophy. The peak aortic valve velocity (odds ratio, 7.1; 95% confidence interval, 1.4-37.1) and diabetes mellitus (odds ratio, 7.4; 95% confidence interval, 1.2-46.2) were the significant factors associated with septal hypertrophy by multivariate analysis. Intraventricular conduction disturbance on electrocardiography was more frequent in the septal hypertrophy group (P = .021). CONCLUSIONS: Left ventricular septal hypertrophy was commonly observed in elderly patients with aortic stenosis, and a higher aortic valve velocity, hypertension, and diabetes mellitus were associated factors. Intraventricular conduction disturbance occurred more often in patients with septal hypertrophy than those without, which implies the pathophysiologic consequence. Further studies are needed to determine the impact of septal hypertrophy and intraventricular conduction disturbance on the prognosis of patients after aortic valve interventions.
Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Electrocardiografía/métodos , Evaluación Geriátrica/métodos , Hipertrofia Ventricular Izquierda/complicaciones , Hipertrofia Ventricular Izquierda/fisiopatología , Anciano , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Masculino , Estudios ProspectivosRESUMEN
Two-dimensional echocardiography (echo) is the method of choice for noninvasive evaluation of the left ventricle (LV) function owing to its low cost, fast acquisition time, and high temporal resolution. However, it only provides the LV boundaries in discrete 2D planes, and the 3D LV geometry needs to be reconstructed from those planes to quantify LV wall motion, acceleration, and strain, or to carry out flow simulations. An automated method is developed for the reconstruction of the 3D LV endocardial surface using echo from a few standard cross sections, in contrast with the previous work that has used a series of 2D scans in a linear or rotational manner for 3D reconstruction. The concept is based on a generalized approach so that the number or type (long-axis (LA) or short-axis (SA)) of sectional data is not constrained. The location of the cross sections is optimized to minimize the difference between the reconstructed and measured cross sections, and the reconstructed LV surface is meshed in a standard format. Temporal smoothing is implemented to smooth the motion of the LV and the flow rate. This software tool can be used with existing clinical 2D echo systems to reconstruct the 3D LV geometry and motion to quantify the regional akinesis/dyskinesis, 3D strain, acceleration, and velocities, or to be used in ventricular flow simulations.
Asunto(s)
Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Imagenología Tridimensional/métodos , Animales , Automatización , Ventrículos Cardíacos/patología , Humanos , Análisis Espacio-Temporal , PorcinosRESUMEN
INTRODUCTION: In patients with intraatrial conduction delay and sinus node (SN) dysfunction, pacing Bachmann's bundle (BBR) and coronary sinus ostium (CSO) has been suggested to achieve atrial resynchronization with potential beneficial impact on atrial fibrillation and diastolic heart failure. Clinical studies have not shown superiority of one approach. METHODS AND RESULTS: We studied electrical activation sequence in an open-chest acute canine model of normal atrial function in 8 mongrel dogs under general anesthesia. Bipolar plunge electrodes were distributed over the surface of the atria during unifocal pacing, and intracardiac activation sequence was observed. SN pacing resulted in near-simultaneous activation at midline sites (BBR and CSO); the left atrium (LA) was activated by anterior and posterior wavefronts simultaneously propagating septally to laterally and meeting at the low-lateral perimitral LA. Right atrial appendage (RAA) pacing created intra-RA conduction delay and delayed onset of LA activation. Pacing from RAA, CSO, and BBR resulted in nonsimultaneous activation at midline sites and produced an anteroposterior gradient of LA activation. This phenomenon was seen to the greatest degree with midline pacing and shifted the site of latest activation away from the low-lateral perimitral LA in all pacing configurations except SN pacing. CONCLUSION: Pacing-induced intra-LA activation dispersion is enhanced with midline atrial pacing, and secondarily shifts the site of latest activation away from the lateral mitral annulus. Measuring atrial activation times to the low-lateral perimitral LA can underestimate the degree of atrial dyssynchrony and be misinterpreted as atrial synchrony. Establishing clinical impact requires evaluation of human data.
Asunto(s)
Fibrilación Atrial/prevención & control , Fibrilación Atrial/fisiopatología , Estimulación Cardíaca Artificial/métodos , Seno Coronario/fisiopatología , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Enfermedad Aguda , Animales , Fibrilación Atrial/diagnóstico , Mapeo del Potencial de Superficie Corporal , Perros , Resultado del TratamientoRESUMEN
OBJECTIVE: To test the Doppler guide wire (DGW) for navigation of the wire positioning by color Doppler ultrasound in the setting of percutaneous coronary intervention (PCI). METHODS: An acoustically active DGW was tested in a water tank before its in vivo use. A waveform generator was connected to the DGW, and a transducer scanned the DGW to visualize a Doppler shift signal between the vibrating piezoelectric crystal located at the DGW tip and Doppler signal from the transducer as a distinct, instantaneous color marker. An intracoronary injection was tested in four male domestic pigs using an open-chest setting. A Judkins left coronary guiding catheter was inserted into the ascending aorta via the right carotid artery under B-mode ultrasound guidance. The DGW with an infusion catheter or over-the-wire (OTW) balloon catheter was inserted into the guiding catheter. The color marker instantaneously defined the DGW tip and navigated the catheter into the left anterior descending artery (LAD). RESULTS: The tip of the DGW was visualized within the guiding catheter by a distinct color marker and helped to engage the guiding catheter to the left main orifice. The DGW with an infusion or OTW balloon catheter was inserted into the LAD. We confirmed that the catheter was positioned in the proximal LAD by the colored territory perfused by an injected indigo carmine solution. CONCLUSION: Ultrasound navigation using acoustically active DGW was feasible. Our pilot study introduces a new concept of color Doppler-navigated wire positioning in the coronary artery in the setting of PCI.
Asunto(s)
Ultrasonografía Doppler en Color , Ultrasonografía Intervencional , Animales , Proyectos Piloto , Porcinos , Masculino , Ultrasonografía Intervencional/métodos , Ultrasonografía Doppler en Color/métodos , Intervención Coronaria Percutánea/métodos , Vasos Coronarios/diagnóstico por imagen , Cirugía Asistida por Computador/métodosRESUMEN
CONTEXT: Humans with obesity and insulin resistance exhibit lipid accumulation in skeletal muscle, but the underlying biological mechanisms responsible for the accumulation of lipid in the muscle of these individuals remain unknown. OBJECTIVE: We investigated how plasma insulin modulates the extraction of circulating triglycerides (TGs) and non-esterified fatty acids (NEFAs) from ingested and endogenous origin in the muscle of lean, insulin-sensitive humans (Lean-IS) and contrasted these responses to those in humans with obesity and insulin resistance (Obese-IR). METHODS: The studies were performed in a postprandial state associated with steady-state plasma TG concentrations. The arterio-venous blood sampling technique was employed to determine the extraction of circulating lipids across the forearm muscle before and after insulin infusion. We distinguished kinetics of TGs and NEFAs from ingested origin from those from endogenous origin across muscle by incorporating stable isotope-labeled triolein in the ingested fat. RESULTS: Insulin infusion rapidly suppressed the extraction of plasma TGs from endogenous, but not ingested, origin in the muscle of the Lean-IS, but this response was absent in the muscle of the Obese-IR. Furthermore, in the muscle of the Lean-IS, insulin infusion decreased the extraction of circulating NEFAs from both ingested and endogenous origin; however, this response was absent for NEFAs from ingested origin in the muscle of the Obese-IR subjects. CONCLUSIONS: Partitioning of circulating lipids away from the skeletal muscle when plasma insulin increases during the postprandial period is impaired in humans with obesity and insulin resistance.
RESUMEN
Context: Humans with obesity and insulin resistance exhibit lipid accumulation in skeletal muscle, but the underlying biological mechanisms responsible for the accumulation of lipid in the muscle of these individuals remain unknown. Objective: We investigated how plasma insulin modulates the extraction of circulating triglycerides (TGs) and non-esterified fatty acids (NEFAs) from ingested and endogenous origin in the muscle of lean, insulin-sensitive humans (Lean-IS) and contrasted these responses to those in humans with obesity and insulin resistance (Obese-IR). Methods: The studies were performed in a postprandial state associated with steady-state plasma TG concentrations. The arterio-venous blood sampling technique was employed to determine the extraction of circulating lipids across the forearm muscle before and after insulin infusion. We distinguished kinetics of TGs and NEFAs from ingested origin from those from endogenous origin across muscle by incorporating stable isotope-labeled triolein in the ingested fat. Results: Insulin infusion rapidly suppressed the extraction of plasma TGs from endogenous, but not ingested, origin in the muscle of the Lean-IS, but this response was absent in the muscle of the Obese-IR. Furthermore, in the muscle of the Lean-IS, insulin infusion decreased the extraction of circulating NEFAs from both ingested and endogenous origin; however, this response was absent for NEFAs from ingested origin in the muscle of the Obese-IR subjects. Conclusions: Partitioning of circulating lipids away from the skeletal muscle when plasma insulin increases during the postprandial period is impaired in humans with obesity and insulin resistance.
RESUMEN
INTRODUCTION: Extracorporeal membrane oxygenation (ECMO) is increasingly used in cardiac arrest (CA). Adequacy of carotid and coronary blood flows (CaBF, CoBF) and coronary perfusion pressure (CoPP) in ECMO treated CA is not well established. This study compares femoro-femoral (FF) to femoro-subclavian (FS) ECMO and intraaortic balloon counterpulsation (IABP) contribution based on CaBF, CoBF, CoPP, myocardial and brain oxygenation in experimental CA managed by ECMO. METHODS: In 11 female pigs (50.3 ± 3.4 kg), CA was randomly treated by FF versus FS ECMO ± IABP. Animals under general anesthesia had undergone 15 minutes of ventricular fibrillation (VF) with ECMO flow of 5 to 10 mL/kg/min simulating low-flow CA followed by continued VF with ECMO flow of 100 mL/kg/min. CaBF and CoBF were measured by a Doppler flow wire, cerebral and peripheral oxygenation by near infrared spectroscopy. CoPP, myocardial oxygen metabolism and resuscitability were determined. RESULTS: CaBF reached values > 80% of baseline in all regimens. CoBF > 80% was reached only by the FF ECMO, 90.0% (66.1, 98.6). Addition of IABP to FF ECMO decreased CoBF to 60.7% (55.1, 86.2) of baseline, P = 0.004. FS ECMO produced 70.0% (49.1, 113.2) of baseline CoBF, significantly lower than FF, P = 0.039. Addition of IABP to FS did not change the CoBF; however, it provided significantly higher flow, 76.7% (71.9, 111.2) of baseline, compared to FF + IABP, P = 0.026. Both brain and peripheral regional oxygen saturations decreased after induction of CA to 23% (15.0, 32.3) and 34% (23.5, 34.0), respectively, and normalized after ECMO institution. For brain saturations, all regimens reached values exceeding 80% of baseline, none of the comparisons between respective treatment approaches differed significantly. After a decline to 15 mmHg (9.5, 20.8) during CA, CoPP gradually rose with time to 68 mmHg (43.3, 84.0), P = 0 .003, with best recovery on FF ECMO. Resuscitability of the animals was high, both 5 and 60 minutes return of spontaneous circulation occured in eight animals (73%). CONCLUSIONS: In a pig model of CA, both FF and FS ECMO assure adequate brain perfusion and oxygenation. FF ECMO offers better CoBF than FS ECMO. Addition of IABP to FF ECMO worsens CoBF. FF ECMO, more than FS ECMO, increases CoPP over time.
Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Arterias Carótidas/fisiología , Circulación Coronaria/fisiología , Vasos Coronarios/fisiología , Oxigenación por Membrana Extracorpórea/métodos , Paro Cardíaco/fisiopatología , Contrapulsador Intraaórtico , Análisis de Varianza , Animales , Modelos Animales de Enfermedad , Femenino , Hemodinámica , Distribución Aleatoria , PorcinosRESUMEN
BACKGROUND: With the advent of numerous minimally invasive medical procedures, accurate catheter guidance has become imperative. We introduce and test an approach for catheter guidance by ultrasound imaging and pulsed-wave (PW) Doppler. METHODS: A steerable catheter is fitted with a small piezoelectric crystal at its tip that actively transmits signals driven by a function generator. We call this an active-tip (AT) catheter. In a water tank, we immersed a "target" crystal and a rectangular matrix of four "reference" crystals. Two-dimensional (2D) ultrasound imaging was used for initial guidance and visualization of the catheter shaft, and then PW Doppler mode was used to identify the AT catheter tip and guide it to the simulated target that was also visible in the 2D ultrasound image. Ten guiding trials were performed from random initial positions of the AT catheter, each starting at approximately 8 cm from the target. RESULTS: After the ten navigational trials, the average final distance of the catheter tip from the target was 2.4 ± 1.2 mm, and the range of distances from the trials was from a minimum of 1.0 mm to a maximum of 4.5 mm. CONCLUSIONS: Although early in the development process, these quantitative in vitro results show promise for catheter guidance with ultrasound imaging and tip identification by PW Doppler.
Asunto(s)
Cateterismo Cardíaco/métodos , Ultrasonografía Doppler de Pulso/métodos , Ultrasonografía Intervencional/métodos , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía Doppler de Pulso/instrumentación , Ultrasonografía Intervencional/instrumentaciónRESUMEN
Echocardiography (echo) is gaining popularity to guide the catheter during surgical procedures. However, it is difficult to discern the catheter tip in echo even with an acoustically active catheter. An acoustically active catheter is detected for the first time in cardiac echo images using two methods. First, a convolutional neural network (CNN) model was trained to detect the region of interest (ROI), the interior of the left ventricle, containing the catheter tip. Color intensity difference detection technique was implemented on the ROI to detect the catheter. This method succeeded in detecting the catheter without any manual input on 94% and 57% of long- and short-axis projections, respectively. Second, several tracking methods were implemented and tested. Given the manually identified initial positions of the catheter, the tracking methods could distinguish between the target (catheter tip) and the surrounding on the rest of the frames. Combining the two techniques, for the first time, resulted in an automatic, robust, and fast method for catheter detection in echo images.
Asunto(s)
Algoritmos , Redes Neurales de la Computación , Catéteres , Ecocardiografía , CorazónRESUMEN
Echocardiographic imaging is ideally suited for the evaluation of cardiac mechanics because of its intrinsically dynamic nature. Because for decades, echocardiography has been the only imaging modality that allows dynamic imaging of the heart, it is only natural that new, increasingly automated techniques for sophisticated analysis of cardiac mechanics have been driven by researchers and manufacturers of ultrasound imaging equipment. Several such techniques have emerged over the past decades to address the issue of reader's experience and inter-measurement variability in interpretation. Some were widely embraced by echocardiographers around the world and became part of the clinical routine, whereas others remained limited to research and exploration of new clinical applications. Two such techniques have dominated the research arena of echocardiography: (1) Doppler-based tissue velocity measurements, frequently referred to as tissue Doppler or myocardial Doppler, and (2) speckle tracking on the basis of displacement measurements. Both types of measurements lend themselves to the derivation of multiple parameters of myocardial function. The goal of this document is to focus on the currently available techniques that allow quantitative assessment of myocardial function via image-based analysis of local myocardial dynamics, including Doppler tissue imaging and speckle-tracking echocardiography, as well as integrated back- scatter analysis. This document describes the current and potential clinical applications of these techniques and their strengths and weaknesses, briefly surveys a selection of the relevant published literature while highlighting normal and abnormal findings in the context of different cardiovascular pathologies, and summarizes the unresolved issues, future research priorities, and recommended indications for clinical use.
Asunto(s)
Ecocardiografía Doppler de Pulso/normas , Interpretación de Imagen Asistida por Computador , Guías de Práctica Clínica como Asunto , Disfunción Ventricular Izquierda/diagnóstico por imagen , Sistema Cardiovascular , Ecocardiografía Doppler en Color/normas , Estudios de Evaluación como Asunto , Femenino , Hemodinámica/fisiología , Humanos , Japón , Masculino , Sociedades MédicasRESUMEN
BACKGROUND AND AIM OF THE STUDY: Discrepancies in mean transvalvular gradient have been observed between Doppler echocardiography and catheter-based techniques in the assessment of aortic stenosis (AS). The Reynolds number (RE) has been shown to influence Doppler-derived gradients, and may be useful in resolving Doppler- and catheter-based gradient discrepancies in AS. The study aim was to assess the influence of the RE on such discrepancies. METHODS: A pulsatile in-vitro heart model using a bioprosthetic aortic valve with leaflets sutured together was used to simulate AS. Simultaneous gradients were measured using Doppler echocardiography and high-fidelity catheters while the RE was varied, by testing solutions of different density and viscosity across a range of cardiac outputs. RESULTS: The echocardiographic and catheter-derived mean gradient (MG) values were correlated (r = 0.89; p < 0.0001); however, significant differences in the MG were observed across hemodynamic states. A direct linear relationship was identified between RE and the absolute difference in MG measured using the two techniques (r = 0.94, p < 0.0001). Relative to catheter-based measurements, the MG was underestimated by Doppler (range: 13-16 mmHg) at low RE (median 6,999) and overestimated (7-33 mmHg) at high RE (median 34,268). However, agreement between catheter- and Doppler-derived gradients was within 5 mmHg at intermediate RE (median 17,284) (p < 0.0001). CONCLUSION: The underestimation of Doppler-derived MGs at low RE relative to catheter-based measurements may be due to an exclusion of viscous friction from the simplified Bernoulli equation, while the overestimation of Doppler-derived MGs at high RE may be due to a pressure recovery effect. However, within an intermediate range of RE, where the effects of viscous and inertial forces are balanced, the agreement between catheter- and Doppler-derived gradients was excellent.
Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Bioprótesis , Cateterismo Cardíaco , Ecocardiografía Doppler , Prótesis Valvulares Cardíacas , Flujo Pulsátil , Análisis de Varianza , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Fricción , Humanos , Modelos Lineales , Modelos Cardiovasculares , Valor Predictivo de las Pruebas , Presión , Técnicas de Sutura , ViscosidadRESUMEN
OBJECTIVES: We performed an in vitro study to assess the precision and accuracy of particle imaging velocimetry (PIV) data acquired using a clinically available portable ultrasound system via comparison with stereo optical PIV. METHODS: The performance of ultrasound PIV was compared with optical PIV on a benchmark problem involving vortical flow with a substantial out-of-plane velocity component. Optical PIV is capable of stereo image acquisition, thus measuring out-of-plane velocity components. This allowed us to quantify the accuracy of ultrasound PIV, which is limited to in-plane acquisition. The system performance was assessed by considering the instantaneous velocity fields without extracting velocity profiles by spatial averaging. RESULTS: Within the 2-dimensional correlation window, using 7 time-averaged frames, the vector fields were found to have correlations of 0.867 in the direction along the ultrasound beam and 0.738 in the perpendicular direction. Out-of-plane motion of greater than 20% of the in-plane vector magnitude was found to increase the SD by 11% for the vectors parallel to the ultrasound beam direction and 8.6% for the vectors perpendicular to the beam. CONCLUSIONS: The results show a close correlation and agreement of individual velocity vectors generated by ultrasound PIV compared with optical PIV. Most of the measurement distortions were caused by out-of-plane velocity components.
Asunto(s)
Velocidad del Flujo Sanguíneo , Medios de Contraste , Ecocardiografía , Óptica y Fotónica , Albúminas , Fluorocarburos , Microburbujas , Modelos CardiovascularesRESUMEN
BACKGROUND: Multiple lines of evidence suggest that cardiovascular co-morbidities hasten the onset of Alzheimer's disease (AD) or accelerate its course. METHODS: To evaluate the utility of cerebral vascular physical function and/or condition parameters as potential systemic indicators of AD, transcranial Doppler (TCD) ultrasound was used to assess cerebral blood flow and vascular resistance of the 16 arterial segments comprising the circle of Willis and its major tributaries. RESULTS: Our study showed that decreased arterial mean flow velocity and increased pulsatility index are associated with a clinical diagnosis of presumptive AD. Cerebral blood flow impairment shown by these parameters reflects the global hemodynamic and structural consequences of a multifaceted disease process yielding diffuse congestive microvascular pathology, increased arterial rigidity, and decreased arterial compliance, combined with putative age-associated cardiovascular output declines. CONCLUSIONS: TCD evaluation offers direct physical confirmation of brain perfusion impairment and might ultimately provide a convenient and a noninvasive means to assess the efficacy of medical interventions on cerebral blood flow or reveal incipient AD. In the near term, TCD-based direct assessments of brain perfusion might offer the prospect of preventing or mitigating AD simply by revealing patients who would benefit from interventions to improve circulatory system function.
Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/fisiopatología , Circulación Cerebrovascular/fisiología , Ultrasonografía Doppler Transcraneal , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo/fisiología , Círculo Arterial Cerebral/diagnóstico por imagen , Círculo Arterial Cerebral/patología , Femenino , Humanos , Masculino , Escala del Estado Mental , Persona de Mediana Edad , Curva ROCRESUMEN
BACKGROUND: A substantial body of evidence collected from epidemiologic, correlative, and experimental studies strongly associates atherosclerotic vascular disease (AVD) with Alzheimer's disease (AD). Depending on the precise interrelationship between AVD and AD, systematic application of interventions used to maintain vascular health and function as a component of standard AD therapy offers the prospect of mitigating the presently inexorable course of dementia. To assess this hypothesis, it is vital to rigorously establish the measures of AVD that are most strongly associated with an AD diagnosis. METHODS: A precise neuropathological diagnosis was established for all subjects, using a battery of genetic, clinical, and histological methods. The severity of atherosclerosis in the circle of Willis was quantified by direct digitized measurement of arterial occlusion in postmortem specimens and was compared between AD and nondemented control groups by calculating a corresponding index of occlusion. RESULTS: Atherosclerotic occlusion of the circle of Willis arteries was more extensive in the AD group than in the nondemented control group. Statistically significant differences were also observed between control and AD groups with regard to Braak stage, total plaque score, total neurofibrillary tangle score, total white matter rarefaction score, brain weight, Mini-Mental State Examination scores, and apolipoprotein E allelic frequencies. CONCLUSIONS: Our results, combined with a consideration of the multifaceted effects of impaired cerebral circulation, suggest an immediate need for prospective clinical trials to assess the efficacy of AD prevention using antiatherosclerotic agents.
Asunto(s)
Enfermedad de Alzheimer/etiología , Círculo Arterial Cerebral/patología , Arteriosclerosis Intracraneal/complicaciones , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/genética , Enfermedad de Alzheimer/patología , Apolipoproteína E4/genética , Progresión de la Enfermedad , Femenino , Humanos , Arteriosclerosis Intracraneal/genética , Arteriosclerosis Intracraneal/patología , Masculino , Ovillos Neurofibrilares/patología , Placa Amiloide/patología , Cambios Post Mortem , Escalas de Valoración Psiquiátrica , Factores de Riesgo , Enfermedades Vasculares/complicaciones , Enfermedades Vasculares/patologíaRESUMEN
BACKGROUND: Two-dimensional echocardiography (2D echo) is the most widely used non-invasive imaging modality due to its fast acquisition time, low cost, and high temporal resolution. Boundary identification of left ventricle (LV) in 2D echo, i.e., image segmentation, is the first step to calculate relevant clinical parameters. Currently, LV segmentation in 2D echo is primarily conducted semi-manually. A fully-automatic segmentation of the LV wall needs further development. METHODS: We evaluated the performance of the state-of-the-art convolutional neural networks (CNNs) for the segmentation of 2D echo images from 6 standard projections of the LV. We used two segmentation algorithms: U-net and segAN. The models were trained using an in-house dataset, which consists of 1,649 porcine images from 6 to 8 different pigs. In addition, a transfer learning approach was used for the segmentation of long-axis projections by training models with our database based on the previously trained weights obtained from Cardiac Acquisitions for Multi-structure Ultrasound Segmentation (CAMUS) dataset. The models were tested on a separate set of images from two other pigs by computing several metrics. The segmentation process was combined with a 3D reconstruction framework to quantify the physiological indices such as LV volumes and ejection fraction (EF). RESULTS: The average dice metric for the LV cavity was 0.90 and 0.91 for the U-net and segAN, respectively, which was higher than 0.82 for the level-set (P value: 3.31×10-25). The average Hausdorff distance for the LV cavity was 2.71 mm and 2.82 mm for the U-net and segAN, respectively, which was lower than 3.64 mm for the level-set (P value: 4.86×10-16). The LV shapes and volumes obtained using the CNN segmentation models were in good agreement with the results segmented by the experts. In addition, the differences of the calculated physiological parameters between two 3D reconstruction models segmented by the experts and CNNs were less than 15%. CONCLUSIONS: The results showed that both CNN models achieve higher performance on LV segmentation than the level-set method. The error of the reconstruction from automatic segmentation compared to the expert segmentation is less than 15%, which is within the 20% error of echo compared to the gold standard.
RESUMEN
In collaboration with the American College of Veterinary Pathologists.
Asunto(s)
Patología Veterinaria , Veterinarios , Animales , Humanos , Estados UnidosRESUMEN
BACKGROUND: Pericardial adhesions are a pathophysiological marker of constrictive pericarditis (CP), which impairs cardiac filling by limiting the total cardiac volume compliance and diastolic filling function. We studied diastolic transmitral flow efficiency as a new parameter of filling function in a pericardial adhesion animal model. We hypothesized that vortex formation time (VFT), an index of optimal efficient diastolic transmitral flow, is altered by patchy pericardial-epicardial adhesions. METHODS: In 8 open-chest pigs, the heart was exposed while preserving the pericardium. We experimentally simulated early pericardial constriction and patchy adhesions by instilling instant glue into the pericardial space and using pericardial-epicardial stitches. We studied left ventricular (LV) function and characterized intraventricular blood flow with conventional and Doppler echocardiography at baseline and following the experimental intervention. RESULTS: Significant decreases in end-diastolic volume, ejection fraction, stroke volume, and late diastolic filling velocity reflected the effects of the pericardial adhesions. The mean VFT value decreased from 3.61 ± 0.47 to 2.26 ± 0.45 (P = 0.0002). Hemodynamic variables indicated the inhibiting effect of pericardial adhesion on both contraction (decrease in systolic blood pressure and +dP/dt decreased) and relaxation (decrease in the magnitude of -dP/dt and prolongation of Tau) function. CONCLUSION: Patchy pericardial adhesions not only negatively impact LV mechanical functioning but the decrease of VFT from normal to suboptimal value suggests impairment of transmitral flow efficiency.