Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Heart Lung Circ ; 33(3): 384-391, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38365497

RESUMEN

AIM: The aim of this study was to assess the recovery rates of diagnostic cardiac procedure volumes in the Oceania Region, midway through the coronavirus disease 2019 (COVID-19) pandemic. METHODS: A survey was performed comparing procedure volumes between March 2019 (pre-pandemic), April 2020 (during first wave of COVID-19 pandemic), and April 2021 (1 year into the COVID-19 pandemic). A total of 31 health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, as well as teaching and non-teaching hospitals. A comparison was made with 549 centres in 96 countries in the rest of the world (RoW) outside of Oceania. The total number and median percentage change in procedure volume were measured between the three timepoints, compared by test type and by facility. RESULTS: A total of 11,902 cardiac diagnostic procedures were performed in Oceania in April 2021 as compared with 11,835 pre-pandemic in March 2019 and 5,986 in April 2020; whereas, in the RoW, 499,079 procedures were performed in April 2021 compared with 497,615 pre-pandemic in March 2019 and 179,014 in April 2020. There was no significant difference in the median recovery rates for total procedure volumes between Oceania (-6%) and the RoW (-3%) (p=0.81). While there was no statistically significant difference in percentage recovery been functional ischaemia testing and anatomical coronary testing in Oceania as compared with the RoW, there was, however, a suggestion of poorer recovery in anatomical coronary testing in Oceania as compared with the RoW (CT coronary angiography -16% in Oceania vs -1% in RoW, and invasive coronary angiography -20% in Oceania vs -9% in RoW). There was no statistically significant difference in recovery rates in procedure volume between metropolitan vs regional (p=0.44), public vs private (p=0.92), hospital vs outpatient (p=0.79), or teaching vs non-teaching centres (p=0.73). CONCLUSIONS: Total cardiology procedure volumes in Oceania normalised 1 year post-pandemic compared to pre-pandemic levels, with no significant difference compared with the RoW and between the different types of health care facilities.


Asunto(s)
COVID-19 , Cardiología , Humanos , COVID-19/epidemiología , Pandemias , Encuestas y Cuestionarios , Angiografía Coronaria , Prueba de COVID-19
2.
J Nucl Cardiol ; 30(3): 1004-1018, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36097241

RESUMEN

INTRODUCTION: AIM: Myocardial perfusion imaging (MPI) is a key tool for the identification and risk stratification of patients with coronary artery disease. The use of a coronary calcium score further adds to prognostic data above MPI alone. In this study, our aim was to evaluate the extent to which the use of a coronary artery calcium (CAC) score, when co-reported with MPI, impacts changes in clinical management in patients without a history of coronary artery disease (CAD) undergoing functional imaging. METHODS: This is a multicenter international study which incorporated a standardized questionnaire to evaluate changes in clinician management after MPI results were given with and without the additional information of a CAC score. Calcium scoring on a SPECT-CT system was performed via a semiquantitative Shemesh score (0-12) with a 0-3 score from the left main, left anterior descending, left circumflex, and right coronary arteries. CT of the chest was read independently, and non-coronary findings were reported alongside the CAC score. RESULTS: A total of 281 patients were enrolled across 3 international centers (Brazil, Australia, New Zealand). Of the 281 patients, 133 (47%) had management altered after the clinician was made aware of the CAC score. The impact of the CAC in changing clinical management was significant, particularly in patients with a negative MPI (P < 0.0001), but also in MPI-positive patients (P = 0.0021). The most common management change was the addition or intensification of statin therapy. CONCLUSION: The addition of the CAC component to MPI yielded significant management changes in nearly half of all patients undergoing MPI for suspected CAD. This trend was observed across all centers in the three countries involved and was particularly evident in patient with a negative MPI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Humanos , Calcio , Australia , Angiografía Coronaria
3.
Heart Lung Circ ; 30(10): 1477-1486, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34053885

RESUMEN

OBJECTIVES: The INCAPS COVID Oceania study aimed to assess the impact caused by the COVID-19 pandemic on cardiac procedure volume provided in the Oceania region. METHODS: A retrospective survey was performed comparing procedure volumes within March 2019 (pre-COVID-19) with April 2020 (during first wave of COVID-19 pandemic). Sixty-three (63) health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, and 846 facilities outside of Oceania. The percentage change in procedure volume was measured between March 2019 and April 2020, compared by test type and by facility. RESULTS: In Oceania, the total cardiac diagnostic procedure volume was reduced by 52.2% from March 2019 to April 2020, compared to a reduction of 75.9% seen in the rest of the world (p<0.001). Within Oceania sites, this reduction varied significantly between procedure types, but not between types of health care facility. All procedure types (other than stress cardiac magnetic resonance [CMR] and positron emission tomography [PET]) saw significant reductions in volume over this time period (p<0.001). In Oceania, transthoracic echocardiography (TTE) decreased by 51.6%, transoesophageal echocardiography (TOE) by 74.0%, and stress tests by 65% overall, which was more pronounced for stress electrocardiograph (ECG) (81.8%) and stress echocardiography (76.7%) compared to stress single-photon emission computerised tomography (SPECT) (44.3%). Invasive coronary angiography decreased by 36.7% in Oceania. CONCLUSION: A significant reduction in cardiac diagnostic procedure volume was seen across all facility types in Oceania and was likely a function of recommendations from cardiac societies and directives from government to minimise spread of COVID-19 amongst patients and staff. Longer term evaluation is important to assess for negative patient outcomes which may relate to deferral of usual models of care within cardiology.


Asunto(s)
COVID-19 , Cardiología , Humanos , Pandemias , Estudios Retrospectivos , SARS-CoV-2 , Tomografía Computarizada por Rayos X
8.
J Nucl Cardiol ; 29(5): 2633-2636, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34647282
9.
J Nucl Cardiol ; 24(3): 851-859, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-26902484

RESUMEN

BACKGROUND: Comparison of Latin American (LA) nuclear cardiology (NC) practice with that in the rest of the world (RoW) will identify areas for improvement and lead to educational activities to reduce radiation exposure from NC. METHODS AND RESULTS: INCAPS collected data on all SPECT and PET procedures performed during a single week in March-April 2013 in 36 laboratories in 10 LA countries (n = 1139), and 272 laboratories in 55 countries in RoW (n = 6772). Eight "best practices" were identified a priori and a radiation-related Quality Index (QI) was devised indicating the number used. Mean radiation effective dose (ED) in LA was higher than in RoW (11.8 vs 9.1 mSv, p < 0.001). Within a populous country like Brazil, a wide variation in laboratory mean ED was found, ranging from 8.4 to 17.8 mSv. Only 11% of LA laboratories achieved median ED <9 mSv, compared to 32% in RoW (p < 0.001). QIs ranged from 2 in a laboratory in Mexico to 7 in a laboratory in Cuba. Three major opportunities to reduce ED for LA patients were identified: (1) more laboratories could implement stress-only imaging, (2) camera-based methods of ED reduction, including prone imaging, could be more frequently used, and (3) injected activity of 99mTc could be adjusted reflecting patient weight/habitus. CONCLUSIONS: On average, radiation dose from NC is higher in LA compared to RoW, with median laboratory ED <9 mSv achieved only one third as frequently as in RoW. Opportunities to reduce radiation exposure in LA have been identified and guideline-based recommendations made to optimize protocols and adhere to the "as low as reasonably achievable" (ALARA) principle.


Asunto(s)
Cardiología/normas , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud/estadística & datos numéricos , Exposición a la Radiación/prevención & control , Protección Radiológica/estadística & datos numéricos , Tomografía Computarizada de Emisión/estadística & datos numéricos , Cardiología/estadística & datos numéricos , Adhesión a Directriz/normas , Adhesión a Directriz/estadística & datos numéricos , Encuestas de Atención de la Salud , Humanos , Internacionalidad , América Latina/epidemiología , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Pautas de la Práctica en Medicina/normas , Mejoramiento de la Calidad , Protección Radiológica/normas , Tomografía Computarizada de Emisión/normas , Revisión de Utilización de Recursos
10.
Circ J ; 81(4): 501-510, 2017 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-28179594

RESUMEN

BACKGROUND: This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia.Methods and Results:Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. CONCLUSIONS: MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care.


Asunto(s)
Imagen de Perfusión Miocárdica/efectos adversos , Pautas de la Práctica en Medicina/normas , Exposición a la Radiación/estadística & datos numéricos , Anciano , Asia , Cardiología/métodos , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medicina Nuclear/métodos , Calidad de la Atención de Salud , Dosis de Radiación , Tecnecio/administración & dosificación , Talio/administración & dosificación
11.
Heart Lung Circ ; 26(1): 25-34, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27425184

RESUMEN

BACKGROUND: There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. METHODS: Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified "best practices" was determined. RESULTS: In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). CONCLUSION: Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world.


Asunto(s)
Imagen de Perfusión Miocárdica/efectos adversos , Dosis de Radiación , Exposición a la Radiación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oceanía
12.
Eur J Nucl Med Mol Imaging ; 43(4): 718-28, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26686336

RESUMEN

PURPOSE: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. METHODS: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). RESULTS: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. CONCLUSION: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Tomografía de Emisión de Positrones/métodos , Guías de Práctica Clínica como Asunto , Dosis de Radiación , Técnicas de Imagen Cardíaca/efectos adversos , Técnicas de Imagen Cardíaca/instrumentación , Técnicas de Imagen Cardíaca/normas , Cardiología/organización & administración , Unión Europea , Medicina Nuclear/organización & administración , Tomografía de Emisión de Positrones/efectos adversos , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/normas , Sociedades Científicas
17.
Eur Heart J ; 36(26): 1689-96, 2015 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-25898845

RESUMEN

AIMS: To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. METHODS AND RESULTS: We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. CONCLUSION: Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally.


Asunto(s)
Adhesión a Directriz/normas , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Guías de Práctica Clínica como Asunto/normas , Dosis de Radiación , Exposición a la Radiación/análisis , Anciano , Cardiología/normas , Protocolos Clínicos/normas , Estudios Transversales , Femenino , Salud Global , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Tomografía de Emisión de Positrones/normas , Tomografía de Emisión de Positrones/estadística & datos numéricos , Práctica Profesional/normas , Práctica Profesional/estadística & datos numéricos , Calidad de la Atención de Salud/normas , Calidad de la Atención de Salud/estadística & datos numéricos , Análisis de Regresión , Tomografía Computarizada de Emisión de Fotón Único/normas , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA