Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 195
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-37952132

RESUMEN

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Asunto(s)
Anticoagulantes , Aspirina , Fibrilación Atrial , Embolia , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Aspirina/efectos adversos , Aspirina/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Canadá , Embolia/etiología , Embolia/prevención & control , Hemorragia/inducido químicamente , Piridonas/efectos adversos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Método Doble Ciego
2.
Circulation ; 149(21): e1197-e1216, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38634276

RESUMEN

Cardiac sarcoidosis is an infiltrative cardiomyopathy that results from granulomatous inflammation of the myocardium and may present with high-grade conduction disease, ventricular arrhythmias, and right or left ventricular dysfunction. Over the past several decades, the prevalence of cardiac sarcoidosis has increased. Definitive histological confirmation is often not possible, so clinicians frequently face uncertainty about the accuracy of diagnosis. Hence, the likelihood of cardiac sarcoidosis should be thought of as a continuum (definite, highly probable, probable, possible, low probability, unlikely) rather than in a binary fashion. Treatment should be initiated in individuals with clinical manifestations and active inflammation in a tiered approach, with corticosteroids as first-line treatment. The lack of randomized clinical trials in cardiac sarcoidosis has led to treatment decisions based on cohort studies and consensus opinions, with substantial variation observed across centers. This scientific statement is intended to guide clinical practice and to facilitate management conformity by providing a framework for the diagnosis and management of cardiac sarcoidosis.


Asunto(s)
American Heart Association , Cardiomiopatías , Sarcoidosis , Humanos , Sarcoidosis/terapia , Sarcoidosis/diagnóstico , Cardiomiopatías/terapia , Cardiomiopatías/diagnóstico , Estados Unidos/epidemiología , Corticoesteroides/uso terapéutico , Manejo de la Enfermedad
3.
J Cardiovasc Electrophysiol ; 35(1): 136-145, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37990448

RESUMEN

INTRODUCTION: Pulmonary vein isolations (PVI) are being performed using a high-power, short-duration (HPSD) strategy. The purpose of this study was to compare the clinical efficacy and safety outcomes of an HPSD versus low-power, long-duration (LPLD) approach to PVI in patients with paroxysmal atrial fibrillation (AF). METHODS: Patients were grouped according to a HPSD (≥40 W) or LPLD (≤35 W) strategy. The primary endpoint was the 1-year recurrence of any atrial arrhythmia lasting ≥30 s, detected using three 14-day ambulatory continuous ECG monitoring. Procedural and safety endpoints were also evaluated. The primary analysis were regression models incorporating propensity scores yielding adjusted relative risk (RRa ) and mean difference (MDa ) estimates. RESULTS: Of the 398 patients included in the AWARE Trial, 173 (43%) underwent HPSD and 225 (57%) LPLD ablation. The distribution of power was 50 W in 75%, 45 W in 20%, and 40 W in 5% in the HPSD group, and 35 W with 25 W on the posterior wall in the LPLD group. The primary outcome was not statistically significant at 30.1% versus 22.2% in HPSD and LPLD groups with RRa 0.77 (95% confidence interval [CI]) 0.55-1.10; p = .165). The secondary outcome of repeat catheter ablation was not statistically significant at 6.9% and 9.8% (RRa 1.59 [95% CI 0.77-3.30]; p = .208) respectively, nor was the incidence of any ECG documented AF during the blanking period: 1.7% versus 8.0% (RRa 3.95 [95% CI 1.00-15.61; p = .049) in the HPSD versus LPLD group respectively. The total procedure time was significantly shorter in the HPSD group (MDa 97.5 min [95% CI 84.8-110.4)]; p < .0001) with no difference in adjudicated serious adverse events. CONCLUSIONS: An HPSD strategy was associated with significantly shorter procedural times with similar efficacy in terms of clinical arrhythmia recurrence. Importantly, there was no signal for increased harm with a HPSD strategy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Resultado del Tratamiento , Recurrencia
4.
Artículo en Inglés | MEDLINE | ID: mdl-38491744

RESUMEN

A 40-year-old man, newly diagnosed with cardiac sarcoidosis (CS) presented with symptomatic ventricular tachycardia three days after starting steroid-based immunosuppressive therapy (IT). There was no clear guideline indication for implantable cardioverter-defibrillator (ICD) before the initiation of IT. Shortly after ICD implantation and the initiation of anti-arrhythmic drugs, recurring ventricular arrhythmias required titration of the anti-arrhythmic drug therapy. One-year follow-up assessment showed no significant arrhythmias and complete PET scan FDG uptake suppression. This case, along with recent publications, suggests transient pro-arrhythmic effects of steroids in patients with CS, which are not appropriately addressed in the current guidelines. We believe ICD implantation should be considered in clinically manifest CS before initiating IT, particularly in cases with heterogeneous and/or extensive FDG uptake on PET scans.

5.
Am Heart J ; 259: 52-57, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36708911

RESUMEN

BACKGROUND: Arm restriction after cardiac implantable electronic device (CIED) placement is common practice despite minimal supporting evidence. Patients receive a range of restriction recommendations of variable durations with the goal of reducing complications such as wound dehiscence, infection, lead dislodgement, or hematoma formation. These movement limitations can lead to emotional stress and anxiety, complications such as frozen shoulder, and upper extremity venous thrombosis due to immobilization. There are no published clinical trials assessing the benefits and risks of arm restrictions post-CIED implant. OBJECTIVES: The randomized trial of lenient vs strict arm and activity instruction post-CIED surgery (LENIENT trial; NCT04915261) is a single center nonblinded randomized prospective study designed to evaluate lenient compared to restrictive post-CIED care instructions. We hypothesize that there will be no significant difference in complications between the arms. METHODS/DESIGN: All patients receiving a de novo CIED or those with upgrades and revisions requiring a new lead implant will be enrolled. Subjects are enrolled in a nonblinded randomized prospective trial with 6 randomly assigned 8-month periods, during which either a lenient or restrictive postoperative activity instructions will be given to all patients. Postoperative instructions are given at the time of discharge and further reinforced by recurrent interactive voice recognition (IVR) phone calls, text messages and emails. The requirement for individual consent has been waived. The primary end point is a composite of (1) lead dislodgement, (2) frozen shoulder, (3) upper extremity venous thrombosis, (4) clinically significant hematoma, and (5) infection occurring within 52 weeks of index surgery. The study is a noninferiority trial with a sample size of 1,250 per group. DISCUSSION: This is the first large randomized clinical trial designed to establish an evidence-based postoperative standard of care for patients undergoing CIED implantation. This will improve the quality of care provided to patients and help guide implanting physicians providing postoperative care instructions. TRIAL REGISTRATION: ClinicalTrials.gov NCT04915261.


Asunto(s)
Desfibriladores Implantables , Trombosis de la Vena , Humanos , Estudios Prospectivos , Brazo , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control
6.
Circ J ; 87(4): 471-480, 2023 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-36624070

RESUMEN

About 5% of sarcoidosis patients develop clinically manifest cardiac features. Cardiac sarcoidosis (CS) typically presents with conduction abnormalities, ventricular arrhythmias and heart failure. Its diagnosis is challenging and requires a substantial degree of clinical suspicion as well as expertise in advanced cardiac imaging. Adverse events, particularly malignant arrhythmias and development of heart failure, are common among CS patients. A timely diagnosis is paramount to ameliorating outcomes for these patients. Despite weak evidence, immunosuppression (primarily with corticosteroids) is generally recommended in the presence of active inflammation in the myocardium. The burden of malignant arrhythmias remains important regardless of treatment, thus leading to the recommended use of an implantable cardioverter defibrillator in most patients with clinically manifest CS.


Asunto(s)
Cardiomiopatías , Desfibriladores Implantables , Insuficiencia Cardíaca , Miocarditis , Sarcoidosis , Humanos , Cardiomiopatías/diagnóstico , Cardiomiopatías/terapia , Arritmias Cardíacas , Sarcoidosis/diagnóstico , Sarcoidosis/terapia
7.
Ann Intern Med ; 175(12): 1658-1665, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36343346

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICDs) improve survival in patients at risk for cardiac arrest, but are associated with intravascular lead-related complications. The subcutaneous ICD (S-ICD), with no intravascular components, was developed to minimize lead-related complications. OBJECTIVE: To assess key ICD performance measures related to delivery of ICD therapy, including inappropriate ICD shocks (delivered in absence of life-threatening arrhythmia) and failed ICD shocks (which did not terminate ventricular arrhythmia). DESIGN: Randomized, multicenter trial. (ClinicalTrials.gov: NCT02881255). SETTING: The ATLAS trial. PATIENTS: 544 eligible patients (141 female) with a primary or secondary prevention indication for an ICD who were younger than age 60 years, had a cardiogenetic phenotype, or had prespecified risk factors for lead complications were electrocardiographically screened and 503 randomly assigned to S-ICD (251 patients) or transvenous ICD (TV-ICD) (252 patients). Mean follow-up was 2.5 years (SD, 1.1). Mean age was 49.0 years (SD, 11.5). MEASUREMENTS: The primary outcome was perioperative major lead-related complications. RESULTS: There was a statistically significant reduction in perioperative, lead-related complications, which occurred in 1 patient (0.4%) with an S-ICD and in 12 patients (4.8%) with TV-ICD (-4.4%; 95% CI, -6.9 to -1.9; P = 0.001). There was a trend for more inappropriate shocks with the S-ICD (hazard ratio [HR], 2.37; 95% CI, 0.98 to 5.77), but no increase in failed appropriate ICD shocks (HR, 0.61 (0.15 to 2.57). Patients in the S-ICD group had more ICD site pain, measured on a 10-point numeric rating scale, on the day of implant (4.2 ± 2.8 vs. 2.9 ± 2.2; P < 0.001) and 1 month later (1.3 ± 1.8 vs. 0.9 ± 1.5; P = 0.035). LIMITATION: At present, the ATLAS trial is underpowered to detect differences in clinical shock outcomes; however, extended follow-up is ongoing. CONCLUSION: The S-ICD reduces perioperative, lead-related complications without significantly compromising the effectiveness of ICD shocks, but with more early postoperative pain and a trend for more inappropriate shocks. PRIMARY FUNDING SOURCE: Boston Scientific.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco , Femenino , Humanos , Desfibriladores Implantables/efectos adversos , Resultado del Tratamiento , Arritmias Cardíacas , Factores de Riesgo , Muerte Súbita Cardíaca/etiología
8.
Am Heart J ; 248: 1-12, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35219715

RESUMEN

BACKGROUND: Recurrence of atrial fibrillation (AF) after a pulmonary vein isolation procedure is often due to electrical reconnection of the pulmonary veins. Repeat ablation procedures may improve freedom from AF but are associated with increased risks and health care costs. A novel ablation strategy in which patients receive "augmented" ablation lesions has the potential to reduce the risk of AF recurrence. OBJECTIVE: The Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence (AWARE) Trial was designed to evaluate whether an augmented wide-area circumferential antral (WACA) ablation strategy will result in fewer atrial arrhythmia recurrences in patients with symptomatic paroxysmal AF, compared with a conventional WACA strategy. METHODS/DESIGN: The AWARE trial was a multicenter, prospective, randomized, open, blinded endpoint trial that has completed recruitment (ClinicalTrials.gov NCT02150902). Patients were randomly assigned (1:1) to either the control arm (single WACAlesion set) or the interventional arm (augmented- double WACA lesion set performed after the initial WACA). The primary outcome was atrial tachyarrhythmia (AA; atrial tachycardia [AT], atrial flutter [AFl] or AF) recurrence between days 91 and 365 post catheter ablation. Patient follow-up included 14-day continuous ambulatory ECG monitoring at 3, 6, and 12 months after catheter ablation. Three questionnaires were administered during the trial- the EuroQuol-5D (EQ-5D) quality of life scale, the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale, and a patient satisfaction scale. DISCUSSION: The AWARE trial was designed to evaluate whether a novel approach to catheter ablation reduced the risk of AA recurrence in patients with symptomatic paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Canadá , Ablación por Catéter/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Resultado del Tratamiento
9.
J Nucl Cardiol ; 29(6): 2824-2836, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-34993894

RESUMEN

BACKGROUND: Alterations in atrial metabolism may play a role in the perpetuation of atrial fibrillation (AF). This study sought to compare 18F-fluorodeoxyglucose (FDG) uptake on PET, in patients with LV dysfunction versus those without AF. METHODS: Seventy-two patients who underwent myocardial viability assessment were evaluated. AF patients (36) had persistent or permanent AF based on history and ECG. Patients without AF (36) were matched to AF patients based on sex, diabetes, age, and LVEF. Maximum and mean FDG Standard Uptake Values (SUV) in the left atrial (LA) wall and right atrial (RA) wall were measured. Tissue-to-blood ratios (TBR) were calculated as atrial wall to blood-pool activity. Atrial volumes were measured by echocardiography. RESULTS: Maximum and mean FDG SUV and TBRs were significantly increased in the RA (but not the LA) of patients with AF compared to those without (P < 0.01). When accounting for changes in atrial volume, the presence of AF remained a significant predictor of higher RAMAX, but not RAMEAN FDG uptake. CONCLUSION: In patients with LV dysfunction from ischemic cardiomyopathy, LA and RA glucose metabolism are differentially altered in those with persistent atrial fibrillation. Further investigations should elucidate the temporal relationship between AF and glucose metabolic changes, as a potential target for therapy.


Asunto(s)
Fibrilación Atrial , Disfunción Ventricular Izquierda , Humanos , Fibrilación Atrial/metabolismo , Fluorodesoxiglucosa F18/metabolismo , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/metabolismo , Miocardio/metabolismo
10.
J Cardiovasc Electrophysiol ; 32(5): 1219-1228, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33751694

RESUMEN

BACKGROUND: The effectiveness, safety, and pulmonary vein (PV) reconnection patterns of point-by-point high-power, short-duration (HPSD) ablation relative to conventional force-time integral (FTI)-guided strategies for atrial fibrillation (AF) ablation are unknown. OBJECTIVES: To compare 1-year freedom from atrial arrhythmia (AA), complication rates, procedural times, and PV reconnection patterns with HPSD AF AF ablation versus an FTI-guided low-power, long-duration (LPLD) strategy. METHODS: We compared consecutive patients undergoing a first ablation procedure for paroxysmal or persistent AF. The HPSD protocol utilized a power of 50 W and durations of 6-8 s posteriorly and 8-10 s anteriorly. The LPLD protocol was FTI-guided with a power of ≤25 W posteriorly (FTI ≥ 300g·s) and ≤35 W anteriorly (FTI ≥ 400g·s). RESULTS: In total, 214 patients were prospectively included (107 HPSD, 107 LPLD). Freedom from AA at 1 year was achieved in 79% in the HPSD group versus 73% in the LPLD group (p = .339; adjusted hazard ratio with HPSD, 0.67; 95% confidence interval, 0.36-1.23; p < .004 for non-inferiority). Procedure duration was shorter in the HPSD group (229 ± 60 vs. 309 ± 77 min; p < .005). Patients undergoing repeat ablation had a higher propensity for reconnection at the right PV carina in the HPSD group compared with the LPLD group (14/30 = 46.7% vs. 7/34 = 20.6%; p = .035). There were no differences in complication rates. CONCLUSION: HPSD AF ablation resulted in similar freedom from AAs at 1 year, shorter procedure times, and a similar safety profile when compared with an LPLD ablation strategy. Patients undergoing HPSD ablation required more applications at the right carina to achieve isolation, and had a significantly higher rate of right carinal reconnections at redo procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
11.
Europace ; 23(23 Suppl 4): iv3-iv10, 2021 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-34051086

RESUMEN

Cardiac implantable electronic device (CIED) infection is a potentially devastating complication of CIED procedures, causing significant morbidity and mortality for patients. Of all CIED complications, infection has the greatest impact on mortality, requirement for re-intervention and additional hospital treatment days. Based on large prospective studies, the infection rate at 12-months after a CIED procedure is approximately 1%. The risk of CIED infection may be related to several factors which should be considered with regards to risk minimization. These include technical factors, patient factors, and periprocedural factors. Technical factors include the number of leads and size of generator, the absolute number of interventions which have been performed for the patient, and the operative approach. Patient factors include various non-modifiable underlying comorbidities and potentially modifiable transient conditions. Procedural factors include both peri-operative and post-operative factors. The contemporary PADIT score, derived from a large cohort of CIED patients, is useful for the prediction of infection risk. In this review, we summarize the key information regarding epidemiology, incidence and risk factors for CIED infection.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Desfibriladores Implantables/efectos adversos , Electrónica , Humanos , Incidencia , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Factores de Riesgo
12.
Europace ; 23(5): 748-756, 2021 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-33367623

RESUMEN

AIMS: Post-operative pain following cardiac implantable electronic device (CIED) insertion is associated with patient dissatisfaction, emotional distress, and emergency department visits. We sought to identify factors associated with post-operative pain and develop a prediction score for post-operative pain. METHODS AND RESULTS: All patients from the BRUISE CONTROL-1 and 2 trials were included in this analysis. A validated Visual Analogue Scale (VAS) was used to assess the severity of pain related to CIED implant procedures. Patients were asked to grade the most severe post-operative pain, average post-operative pain, and pain on the day of the first post-operative clinic. Multivariable regression analyses were performed to identify predictors of significant post-operative pain and to develop a pain-prediction score. A total of 1308 patients were included. Multivariable regression analysis found that the presence of post-operative clinically significant haematoma {CSH; P value < 0.001; odds ratio (OR) 3.82 [95% confidence interval (CI): 2.37-6.16]}, de novo CIED implantation [P value < 0.001; OR 1.90 (95% CI: 1.47-2.46)], female sex [P value < 0.001; OR 1.61 (95% CI: 1.22-2.12)], younger age [<65 years; P value < 0.001; OR 1.54 (95% CI: 1.14-2.10)], and lower body mass index [<20 kg/m2; P value < 0.05; OR 2.05 (95% CI: 0.98-4.28)] demonstrated strong and independent associations with increased post-operative pain. An 11-point post-operative pain prediction score was developed using the data. CONCLUSION: Our study has identified multiple predictors of post-operative pain after CIED insertion. We have developed a prediction score for post-operative pain that can be used to identify individuals at risk of experiencing significant post-operative pain.


Asunto(s)
Contusiones , Desfibriladores Implantables , Marcapaso Artificial , Anciano , Desfibriladores Implantables/efectos adversos , Electrónica , Femenino , Humanos , Marcapaso Artificial/efectos adversos , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Estudios Retrospectivos , Factores de Riesgo
13.
J Cardiovasc Electrophysiol ; 31(10): 2751-2758, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32713090

RESUMEN

INTRODUCTION: We sought to explore the relationship between ventricular tachycardia (VT) and premature ventricular complex (PVC) burden (from implantable cardioverter-defibrillator diagnostics), before and during corticosteroid use in patients with newly diagnosed clinically manifest cardiac sarcoidosis (CS). METHODS: A single-centre, prospective cohort study was performed in consecutive patients who met all of the following criteria: (1) presentation with clinically manifest CS, (2) abnormal myocardial fluoro-deoxyglucose (FDG) uptake on positron emission tomography scan, (3) plan for implantation with implantable cardioverter-defibrillator device that reports accurate PVC count, (4) plan to initiate corticosteroids after the device healing period. Data were collected during each device interrogation visit for all patients in the study. For each inter-visit period the total number of episodes of VT-sustained and nonsustained, and the number of PVCs was obtained. Each inter-visit period was classified into one of the following three periods: (1) New diagnosis of treatment-naive active disease without corticosteroids during the period. (2) Known treatment-naive active disease with corticosteroids initiated during the inter-visit period. (3) On corticosteroid therapy during the entire period. RESULTS: A total of 20 patients with a mean age of 59.7 ± 7.7 years were recruited and 82 inter-visit periods were analyzed. All patients were corticosteroid responders based on FDG uptake. The maximum left ventricular standardized uptake value was 11.14 ± 5.19 before corticosteroid initiation and 4.07 ± 0.88 after (p < .001). Patients with active untreated CS had an average of 496.4 ± 879.1 PVCs per day. After treatment with corticosteroids, the average PVC count increased to 1332.4 ± 1865.7/day during Period 2 (p = .036) and to 1590.1 ± 2362.2 per day during Period 3 (p = .008). There was also a statistically significant increase in episodes of nonsustained ventricular tachycardia (NSVT) before and after treatment with corticosteroids (p = .017). There were too few episodes of sustained ventricular arrhythmia to analyze. Overall, 18 out of 20 patients (90%) had an increase in PVC burden after corticosteroid initiation. CONCLUSION: This study demonstrated, on average, a threefold increase in daily PVC count in clinically manifest CS patients during treatment with corticosteroids compared to pretreatment. There was also a significant increase in episodes of NSVT. Clinicians and patients with active manifest CS should be aware that corticosteroids are unlikely to lead to a reduction in the burdens of PVC and NSVT.


Asunto(s)
Desfibriladores Implantables , Sarcoidosis , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Corticoesteroides/efectos adversos , Niño , Humanos , Estudios Prospectivos , Sarcoidosis/diagnóstico por imagen , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/diagnóstico por imagen
14.
Pacing Clin Electrophysiol ; 43(11): 1373-1381, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33058175

RESUMEN

BACKGROUND: Many patients undergoing cardiac device implantation are taking direct oral anticoagulation (DOAC). Continuing DOAC during device implantation may increase periprocedural bleeding risk; however, interrupting DOACs may increase thromboembolic risk. OBJECTIVE: To compare the incidence of clinically significant pocket hematoma and thromboembolism in patients who have their DOAC continued or interrupted for cardiac device implantation. METHODS: We searched MEDLINE, EMBASE, and randomized controlled trial (CENTRAL) until December 2019 and included randomized controlled trials (RCTs) and observational studies that compared outcomes after continuing or interrupting DOAC during cardiac device implantation. Independently and in duplicate, reviewers screened titles, abstracts, and full text of potentially eligible studies. They then evaluated risk of bias and abstracted data. RCT data were pooled using a fixed-effect model. Quality of evidence was assessed using grading of recommendations assessment, development and evaluation (GRADE). RESULTS: Two RCTs, representing 763 patients, and three observational studies met eligibility criteria. In RCTs, continuing DOAC for device implantation compared to interrupting DOAC resulted in no significant difference in clinically significant pocket hematoma (2.1% vs 1.8%; RR 1.15; 95% CI 0.44-3.05) or thromboembolism (0.03% vs 0.03%; RR 1.02; 95% CI 0.06-16.21). Quality of evidence for both outcomes was moderate due to imprecision. Observational studies showed similar results. CONCLUSIONS: Continuing DOACs for device implantation results in little to no difference in the incidence of clinically significant pocket hematoma or thromboembolism. Given the ease of stopping and restarting DOACs, interrupting DOACs may be the preferred strategy for most patients. However, whenever continuous therapeutic anticoagulation is desired, DOAC continuation should be preferred over bridging with parenteral anticoagulation.


Asunto(s)
Anticoagulantes/administración & dosificación , Dispositivos de Terapia de Resincronización Cardíaca , Implantación de Prótesis , Administración Oral , Hematoma/inducido químicamente , Humanos , Factores de Riesgo , Tromboembolia/prevención & control
15.
Semin Respir Crit Care Med ; 41(5): 626-640, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32593175

RESUMEN

Approximately 5% of patients with sarcoidosis will have clinically manifest cardiac involvement presenting with one or more of ventricular arrhythmias, conduction abnormalities, and heart failure. It is estimated that another 20 to 25% of pulmonary/systemic sarcoidosis patients have asymptomatic cardiac involvement (clinically silent disease). Cardiac presentations can be the first (and/or an unrecognized) manifestation of sarcoidosis in a variety of circumstances. Immunosuppression therapy (usually with corticosteroids) has been suggested for the treatment of clinically manifest cardiac sarcoidosis (CS) despite minimal data supporting it. Positron emission tomography imaging is often used to detect active disease and guide immunosuppression. Patients with clinically manifest disease often need device therapy, typically with implantable cardioverter defibrillators (ICDs). The extent of left ventricular dysfunction seems to be the most important predictor of prognosis among patients with clinically manifest CS. In the current era of earlier diagnosis, modern heart failure treatment, and use of ICD therapy, the prognosis from CS is much improved. In a recent Finnish nationwide study, 10-year cardiac survival was 92.5% in 102 patients.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Cardiomiopatías/diagnóstico , Insuficiencia Cardíaca/diagnóstico , Sarcoidosis/diagnóstico , Arritmias Cardíacas/terapia , Cardiomiopatías/terapia , Desfibriladores Implantables , Diagnóstico Precoz , Insuficiencia Cardíaca/terapia , Humanos , Tomografía de Emisión de Positrones , Pronóstico , Sarcoidosis/terapia
16.
J Electrocardiol ; 63: 167-172, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31668635

RESUMEN

BACKGROUND: Current LBBB definitions cannot always distinguish LBBB from left ventricular conduction delay. Only patients with LBBB are expected to normalize with His bundle pacing. Patients who develop new LBBB immediately post transcatheter aortic valve replacement (TAVR) provide an excellent model to define electrocardiogram (ECG) features of LBBB. We sought to describe their ECG features and develop a new ECG definition of LBBB. METHODS: We screened ECGs from 264 consecutive patients who underwent TAVR at the University of Ottawa Heart Institute. Patients with a baseline QRS of ≤100 ms who developed QRS ≥120 ms immediately after TAVR were included. Two electrocardiologists reviewed all ECG independently. Baseline demographics and echocardiographic data were retrospectively collected. RESULTS: 36 patients were included in the analysis. The median age was 85.5 years (IQR, 81.8-89 years) and 52.8% were males. The minimum QRS duration was 126 ms. The median QRS axis was -18° (IQR, -40-4.5°), which is 18.5° leftward compared to the median QRS axis before TAVR. Fourteen patients (38.9%) had left axis deviation. All patients had a notched/slurred R wave in at least one lateral lead and an R wave duration of ≤20 ms in V1 when present. CONCLUSION: We developed a new ECG definition of LBBB that includes 2 novel findings: notching/slurring of the R wave in at least one lateral lead and an R wave ≤20 ms in V1. Further larger studies are warranted to confirm these findings.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Bloqueo de Rama/diagnóstico , Electrocardiografía , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
17.
Am Heart J ; 207: 1-9, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30399474

RESUMEN

BACKGROUND: The defibrillator lead is the weakest part of the transvenous (TV) implantable cardioverter defibrillation (ICD) system and a frequent cause of morbidity. Lead dislodgement, cardiac perforation, insertion-related trauma including pneumothorax and vascular injury, are common early complications of TV-ICD implantation. Venous occlusion, tricuspid valve dysfunction, lead fracture and lead insulation failure are additional, later complications. The introduction of a totally sub-cutaneous ICD (S-ICD) may reduce these lead-related issues, patient morbidity, hospitalizations and costs. However, such benefits compared to the TV-ICD have not been demonstrated in a randomized trial. DESIGN: ATLAS (Avoid Transvenous Leads in Appropriate Subjects) is a multi-centered, randomized, open-label, parallel group trial. Patients younger than 60 years are eligible. If older than 60 years, patients are eligible if they have an inherited heart rhythm disease, or risk factors for ICD-related complication, such as hemodialysis, a history of ICD or pacemaker infection, heart valve replacement, or severe pulmonary disease. This study will determine if using an S-ICD compared to a TV-ICD reduces a primary composite outcome of perioperative complications including pulmonary or pericardial perforation, lead dislodgement or dysfunction, tricuspid regurgitation and ipsilateral venous thrombosis. Five hundred patients will be enrolled from 14 Canadian hospitals, and data collected to both early- (at 6 months) and mid-term complications (at 24 months) as well as mortality and ICD shock efficacy. SUMMARY: The ATLAS randomized trial is comparing early- and mid-term vascular and lead-related complications among S-ICD versus TV-ICD recipients who are younger or at higher risk of ICD-related complications.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Falla de Equipo , Selección de Paciente , Complicaciones Posoperatorias/prevención & control , Adulto , Comités Consultivos , Factores de Edad , Canadá , Diseño de Equipo , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Proyectos de Investigación , Factores de Riesgo , Adulto Joven
18.
J Cardiovasc Electrophysiol ; 30(1): 78-88, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30203499

RESUMEN

INTRODUCTION: Fluoroscopy use during catheter ablation procedures increases the cumulative lifetime radiation exposure of patients and operators, potentially leading to a higher risk of cancer and radiation-related injuries. Nonfluoroscopic ablation (NFA) has been described for supraventricular tachycardia, typical atrial flutter, paroxysmal atrial fibrillation (AF), and outflow-tract ventricular tachycardia (VT). Complete transition to NFA of more complex arrhythmias, including persistent AF, left atrial (LA) flutter, and structural VT, has not been previously described. We describe the transition to completely NFA of complex arrhythmias, including LA flutter and structural VT. The techniques, challenges, limitations, and results are described. METHODS AND RESULTS: Complex ablation procedures were performed using intracardiac echocardiography (ICE) and a three-dimensional mapping system without fluoroscopy or lead protection. Eighty consecutive patients underwent NFA (mean age, 60.1 ± 9.9 years, 70 with LA arrhythmias, 10 with VT). All cases were performed without the need for rescue fluoroscopy. There was an initial increase in procedural time for ablation of LA arrhythmias upon transitioning to NFA. However, after excluding the first 20 NFA cases to allow for operator learning, the transition to NFA was not associated with an increase in mean procedural time (229 ± 38 vs 225 ± 32 minutes; P = 0.002 for noninferiority). All procedures were completed successfully with no complications. CONCLUSIONS: NFA of most complex arrhythmias (persistent AF, LA flutter, and structural VT) is feasible, with a modest learning curve and no increase in procedural times.


Asunto(s)
Fibrilación Atrial/cirugía , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Ecocardiografía , Fenómenos Electromagnéticos , Taquicardia Ventricular/cirugía , Ultrasonografía Intervencional/métodos , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Curva de Aprendizaje , Masculino , Persona de Mediana Edad , Tempo Operativo , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos , Flujo de Trabajo
19.
Europace ; 21(1): 48-53, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29897439

RESUMEN

AIMS: There is ongoing controversy about the need for routine transoesophageal echocardiography (TOE) prior to atrial fibrillation (AF) ablation. Recently, the debate was reignited by the publication of a large series of patients showing a prevalence of left atrial appendage thrombus (LAAT) on TOE of 4.4%. We sought to assess the prevalence of LAAT on TOE before AF ablation at our institution. METHODS AND RESULTS: Consecutive patients scheduled for AF ablation at our institution between January 2009 and December 2016 were included. All patients were on oral anticoagulation for at least 4 weeks prior to TOE. Transoesophageal echocardiographies were performed 3-5 days prior to scheduled AF ablation. Data were collected utilizing a prospective database. In all, 668 patients and 943 AF ablation procedures were included. Mean age was 64 ± 11 years, 72% were male, average CHADS2 score was 1.0 ± 1.0, and 72% of the patients had paroxysmal AF. At the time of ablation, 496 (53%) were on non-vitamin K antagonist oral anticoagulants (NOACs) and 447 (47%) were on Warfarin. There were three cases with LAAT (3/943, 0.3%), all of whom had persistent AF and were on Warfarin. Two patients underwent surgical ablation and the third patient did not undergo ablation. CONCLUSION: In our experience, the prevalence of LAAT in patients on anticoagulation therapy undergoing TOE before catheter ablation of AF is 0.3%, which was much lower than recently reported. None of the patients with paroxysmal AF or on NOACs were found to have LAAT. Rather than routine use of TOE prior to AF ablation, a risk-based approach should be considered.


Asunto(s)
Anticoagulantes/administración & dosificación , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/tratamiento farmacológico , Ecocardiografía Transesofágica , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Administración Oral , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Ablación por Catéter , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ontario/epidemiología , Valor Predictivo de las Pruebas , Prevalencia , Sistema de Registros , Factores de Riesgo
20.
Europace ; 21(5): 708-715, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30535367

RESUMEN

AIMS: Electrical cardioversion is commonly performed to restore sinus rhythm in patients with atrial fibrillation (AF), but it is unsuccessful in 10-12% of attempts. We sought to evaluate the effectiveness and safety of a novel cardioversion protocol for this arrhythmia. METHODS AND RESULTS: Consecutive elective cardioversion attempts for AF between October 2012 and July 2017 at a tertiary cardiovascular centre before (Phase I) and after (Phase II) implementing the Ottawa AF cardioversion protocol (OAFCP) as an institutional initiative in July 2015 were evaluated. The primary outcome was cardioversion success, defined as ≥2 consecutive sinus beats or atrial-paced beats in patients with implanted cardiac devices. Secondary outcomes were first shock success, sustained success (sinus or atrial-paced rhythm on 12-lead electrocardiogram prior to discharge from hospital), and procedural complications. Cardioversion was successful in 459/500 (91.8%) in Phase I compared with 386/389 (99.2%) in Phase II (P < 0.001). This improvement persisted after adjusting for age, body mass index, amiodarone use, and transthoracic impedance using modified Poisson regression [adjusted relative risk 1.08, 95% confidence interval (CI) 1.05-1.11; P < 0.001] and when analysed as an interrupted time series (change in level +9.5%, 95% CI 6.8-12.1%; P < 0.001). The OAFCP was also associated with greater first shock success (88.4% vs. 79.2%; P < 0.001) and sustained success (91.6% vs 84.7%; P=0.002). No serious complications occurred. CONCLUSION: Implementing the OAFCP was associated with a 7.4% absolute increase in cardioversion success and increases in first shock and sustained success without serious procedural complications. Its use could safely improve cardioversion success in patients with AF. CLINICAL TRIAL NUMBER: www.clinicaltrials.gov ID: NCT02192957.


Asunto(s)
Fibrilación Atrial , Protocolos Clínicos/normas , Cardioversión Eléctrica , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/métodos , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Mejoramiento de la Calidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA