RESUMEN
This paper presents computational and experimental studies on wavelength/frequency fluctuation characteristics of a high pulse repetition rate (18 kHz) dye laser pumped by a frequency-doubled Nd:YAG laser (532 nm). The temperature gradient in the dye solution is found to be responsible for wavelength fluctuations of the dye laser at low flow rates (2800
RESUMEN
With the growing information on web, online movie review is becoming a significant information resource for Internet users. However, online users post thousands of movie reviews on daily basis and it is hard for them to manually summarize the reviews. Movie review mining and summarization is one of the challenging tasks in natural language processing. Therefore, an automatic approach is desirable to summarize the lengthy movie reviews, and it will allow users to quickly recognize the positive and negative aspects of a movie. This study employs a feature extraction technique called bag of words (BoW) to extract features from movie reviews and represent the reviews as a vector space model or feature vector. The next phase uses Naïve Bayes machine learning algorithm to classify the movie reviews (represented as feature vector) into positive and negative. Next, an undirected weighted graph is constructed from the pairwise semantic similarities between classified review sentences in such a way that the graph nodes represent review sentences, while the edges of graph indicate semantic similarity weight. The weighted graph-based ranking algorithm (WGRA) is applied to compute the rank score for each review sentence in the graph. Finally, the top ranked sentences (graph nodes) are chosen based on highest rank scores to produce the extractive summary. Experimental results reveal that the proposed approach is superior to other state-of-the-art approaches.
Asunto(s)
Algoritmos , Películas Cinematográficas/estadística & datos numéricos , Aprendizaje Automático Supervisado , Humanos , Lenguaje , Procesamiento de Lenguaje NaturalRESUMEN
Machine learning, one of the core disciplines of artificial intelligence, is an approach whose main emphasis is analytical model building. In other words, machine learning enables an automaton to make its own decisions based on a previous training process. Machine learning has revolutionized every research sector, including health care, by providing precise and accurate decisions involving minimal human interventions through pattern recognition. This is emphasized in this research, which addresses the issue of "support for diabetic neuropathy (DN) recognition." DN is a disease that affects a large proportion of the global population. In this research, we have used gait biomarkers of subjects representing a particular sector of population located in southern Mexico to identify persons suffering from DN. To do this, we used a home-made body sensor network to capture raw data of the walking pattern of individuals with and without DN. The information was then processed using three sampling criteria and 23 assembled classifiers, in combination with a deep learning algorithm. The architecture of the best combination was chosen and reconfigured for better performance. The results revealed a highly acceptable classification with greater than 85% accuracy when using these combined approaches.
Asunto(s)
Biomarcadores/análisis , Aprendizaje Profundo , Neuropatías Diabéticas/diagnóstico por imagen , Marcha , Acelerometría , Adulto , Algoritmos , Inteligencia Artificial , Bases de Datos Factuales , Femenino , Humanos , Masculino , México , Persona de Mediana Edad , Monitoreo Ambulatorio , Curva ROC , Reproducibilidad de los Resultados , CaminataRESUMEN
Live fish in throat is a rare foreign body. Here we present two such cases. The foreign body were removed under general anaesthesia and nutrition was maintained by Nasogastric tube for few days. Patient returned to normal duty within a week.
RESUMEN
For lack of other suitable access, 10 consecutive patients received paired hemodialysis catheters for long-term hemodialysis using a translumbar approach to the inferior vena cava (IVC). All attempts were successful. Five paired catheters were placed using the single-puncture technique, and five using the dual-puncture technique. Catheters were in place for a total of 2252 catheter days. The average duration of catheter placement was 250 days (range 30-580 days). All catheters were functioning up to the time the study was completed or the patient died. The most common complication was partial dislodgment of the catheter in 3 of 23 catheters (13%), all occurring in obese patients. One episode of retroperitoneal hemorrhage was noted in a patient having the single-access technique. There were no episodes of infection or IVC thrombosis.
Asunto(s)
Cateterismo/métodos , Catéteres de Permanencia , Diálisis Renal , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Vena Cava InferiorRESUMEN
Though polycystic liver disease (PCLD) has historically been considered a contraindication to TIPS, we present a case where technically successful shunt creation was achieved without the need for modification of the standard TIPS procedure, as was required in a previous report.
Asunto(s)
Ascitis/cirugía , Quistes/cirugía , Hepatopatías/cirugía , Derivación Portosistémica Intrahepática Transyugular/métodos , Ascitis/etiología , Quistes/complicaciones , Quistes/diagnóstico , Resultado Fatal , Femenino , Estudios de Seguimiento , Humanos , Hepatopatías/complicaciones , Hepatopatías/diagnóstico , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Ultrasonografía DopplerRESUMEN
Although genetical inheritance is an well established fact with medullary cancer of thyroid no such clear cut proof exist with papillary or follicular neoplasm of thyroid It's a fact that family clusters of non-medullary thyroid tumor exist, it requires more precise identification of genetical inheritance These clusters behave in a separate way and requires a more aggressive treatment for low recurrence rate and better prognosis.
RESUMEN
PURPOSE: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data. METHODS: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. A combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data. RESULTS: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically significant (p = 0.6). Aspiration occlusion occurred in 13 patients (11.7%). Intracatheter urokinase was infused in eight of these patients and successfully restored catheter function in all but two instances. These complication rates are comparable to or better than those reported with chest ports. CONCLUSION: Peripheral ports for long-term central venous access placed by interventional radiologists in the interventional radiology suite are as safe and as effective as chest ports.