Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Rev Esp Enferm Dig ; 115(3): 110-114, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35656921

RESUMEN

INTRODUCTION: retention is the most common adverse event of the small bowel capsule endoscopy procedure. Patency capsule (Medtronic, Dublin, Ireland) and magnetic resonance enterography are two diagnostic methods that can prevent small bowel capsule endoscopy retention. The aim of this study was to evaluate the predictive value of these two diagnostic methods. MATERIAL AND METHODS: a prospective, comparative and observational study was performed in patients with established Crohn's disease. All patients had undergone magnetic resonance enterography and patency capsule procedures. If the patency capsule was not retained, the patient underwent a small bowel capsule endoscopy; otherwise, double balloon enteroscopy was performed to locate the stenosis. Magnetic resonance enterography predictive criteria for retention were analyzed in all cases. Sensitivity, specificity, positive predictive value and negative predictive value of the patency capsule and magnetic resonance enterography compared to small bowel capsule endoscopy or double balloon enteroscopy were calculated. RESULTS: forty patients were included (24 female, 55 ± 13 years old). Retention criteria with capsule endoscopy or double balloon enteroscopy were found in six patients, agreeing in five cases with patency capsule and in three cases with magnetic resonance enterography. Sensitivity, specificity, positive predictive value, negative predictive value and Kappa coefficient for predicting retention with the patency capsule were 83 %, 100 %, 100 % and 97 %, respectively, and 50 %, 91 %, 50 % and 91 %, respectively, with magnetic resonance enterography. CONCLUSIONS: patency capsule has a higher sensitivity and positive predictive value than magnetic resonance enterography for preventing small bowel capsule endoscopy retention in Crohn's disease patients.


Asunto(s)
Endoscopía Capsular , Enfermedad de Crohn , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Enfermedad de Crohn/diagnóstico , Endoscopía Capsular/métodos , Estudios Prospectivos , Intestino Delgado/diagnóstico por imagen , Intestino Delgado/patología , Espectroscopía de Resonancia Magnética
2.
Dig Dis ; 39(3): 211-216, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33011721

RESUMEN

INTRODUCTION: Capsule endoscopy (CE) is the first-line tool for diagnosis of small bowel bleeding. There are some studies that have compared different types of CE. OMOM CE is one of the newest in the market and has not been compared with other types of CE. The objective of this study was to compare the diagnostic yield of the Pillcam SB3 and OMOM CE in small bowel bleeding. MATERIALS AND METHODS: This is a prospective, comparative, randomized, and blinded study. Patients with suspected small bowel bleeding were included. All the patients were given both types of CE in random order. Diagnostic yield and functionality between the 2 types of CE were analyzed. RESULTS: We included 44 patients, 54.5% were female with a median age of 63.5 years. Battery time was significantly longer with SB3 (816.5 vs. 700.5 min, p < 0.001), and the download time was shorter with OMOM (33 vs. 132 min, p < 0.001). Both CEs presented 1 failure. The cause of the bleeding was identified in 39 SB3 (88.6%) and in 34 OMOM CE (77.3%) (p = 0.256). P2 lesions were observed in 32 SB3 (72.7%) and in 29 OMOM CE (65.9%) (p = 0.784). The agreement between both CEs for P2 lesions was moderate (κ = 0.628). CONCLUSIONS: Pillcam SB3 and OMOM devices are safe procedures and have a similar diagnostic yield. Significant differences were observed in the battery life and download time with both CEs.


Asunto(s)
Endoscopía Capsular , Hemorragia Gastrointestinal/diagnóstico por imagen , Hemorragia Gastrointestinal/diagnóstico , Intestino Delgado/diagnóstico por imagen , Intestino Delgado/patología , Anciano , Femenino , Hemorragia Gastrointestinal/etiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
3.
Rev Esp Enferm Dig ; 113(1): 76-77, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33213175

RESUMEN

The agreement between capsule endoscopy (CE) and device-assisted enteroscopy (DAE) in tumors of the small-bowel (SB) may be high. However, other SB lesions such as ulcers and angioectasias seem to have more agreement between both procedures, compared to tumors or polyps. In the article published by Alventosa-Mateu C et al., an interesting case was presented of a patient with iron deficiency anemia secondary to two carcinoid ileum tumors, identified by CE and later biopsied and tattooed by DAE.


Asunto(s)
Anemia Ferropénica , Endoscopía Capsular , Laparoscopía , Hemorragia Gastrointestinal/diagnóstico por imagen , Hemorragia Gastrointestinal/etiología , Humanos , Intestino Delgado/diagnóstico por imagen
4.
Gastrointest Endosc ; 92(6): 1190-1201, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32343977

RESUMEN

BACKGROUNDS AND AIMS: New mucosal resective and ablative endoscopic procedures based on gastric cardiac remodeling to prevent reflux have appeared. We aimed to evaluate the feasibility of a new ablative technique named antireflux ablation therapy (ARAT) for control of GERD in patients without hiatal hernia. METHODS: Patients with proton pump inhibitor (PPI)-refractory GERD without hiatal hernia underwent ARAT between January 2016 and October 2019. Gastroesophageal Reflux Disease-Health-Related Quality of Life (GERD-HRQL), upper endoscopy, 24-hour pH monitoring, and PPI use were documented at 3, 6, 12, 24, and 36 months after ARAT. RESULTS: One hundred eight patients were included (61 men [56.5%]; median age, 36.5 years; range, 18-78 years). ARAT was performed on all patients. At the 36-month evaluation, 84 patients had completed the protocol. Median ARAT time was 35.5 minutes (range, 22-51 minutes), and median circumference ablation was 300° (range, 270°-320°). No major adverse events occurred, and 14 of 108 patients (12.9%) presented with stenosis that was responsive to balloon dilation (<5 sessions). At the 3-month evaluation, the acid exposure time (AET), DeMeester score, and GERD-HRQL score had decreased from 18.8% to 2.8% (P = .001), 42.5 to 9.1 (P = .001), and 36.5 to 10 (P = .02), respectively, and these values were maintained up to 36 months. Success (AET <4%) was achieved in 89% and 72.2% at 3 and 36 months, respectively. Related factors at 36 months were as follows: pre-ARAT Hill type II (odds ratio [OR], 3.212; 95% confidence interval [CI], 1.431-5.951; P = .033), post-ARAT 3-month Hill type I (OR, 4.101; 95% CI, 1.812-9.121; P = .042), and AET <4% at 3 months (OR, 5.512; 95% CI, 1.451-7.621; P = .021). CONCLUSIONS: ARAT is a feasible, safe, and effective therapy for early and mid-term treatment of GERD in patients without a sliding hiatal hernia. However, longer follow-up evaluations and randomized comparative studies are needed to clarify its real role. (Clinical trial registration number: NCT03548298.).


Asunto(s)
Técnicas de Ablación , Fundoplicación , Reflujo Gastroesofágico , Hernia Hiatal , Técnicas de Ablación/métodos , Adolescente , Adulto , Anciano , Endoscopía Gastrointestinal , Monitorización del pH Esofágico , Estudios de Factibilidad , Femenino , Reflujo Gastroesofágico/tratamiento farmacológico , Reflujo Gastroesofágico/cirugía , Hernia Hiatal/tratamiento farmacológico , Hernia Hiatal/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Inhibidores de la Bomba de Protones/uso terapéutico , Calidad de Vida , Resultado del Tratamiento , Adulto Joven
5.
Rev Esp Enferm Dig ; 112(4): 290-293, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32193940

RESUMEN

INTRODUCTION: studies have examined the agreement between capsule endoscopy and double-balloon enteroscopy, with varying results. The aim of this study was to identify factors that predict the visualization of lesions in the small bowel by double-balloon enteroscopy after a positive capsule endoscopy. METHODS: a retrospective, observational and comparative study was performed that evaluated patients that underwent double-balloon enteroscopy after a positive capsule endoscopy, between January 2017 and August 2019. The data studied included demographics, indications, comorbidities and the results of capsule endoscopy and double-balloon enteroscopy, which were evaluated by multiple logistic regression. RESULTS: 91 patients were included (age 58 ± 16.5 years, 53 female). Sixty-two double-balloon enteroscopy (68.1 %) found the same lesions as capsule endoscopy. Predictive factors for a positive double-balloon enteroscopy were multiple lesions (OR 8.10, 1.50-43.78; p = 0.015) and < 15 days between both studies (OR 5.31, 1.19-23.66; p=0.029). In the subgroup of patients with small bowel bleeding (70 patients), the results of 46 double-balloon enteroscopies (65.7 %) agreed with the capsule endoscopy. Predictive factors in this group were multiple lesions (OR 13.51, 1.78-102.22; p = 0.012), < 15 days between both studies (OR 13.51, 1.78-102.22; p = 0.012), > 60 years of age (OR 7.45, 1.51-36.75; p = 0.014) and ulcers (OR 4.67, 1.08-20.22; p = 0.039). CONCLUSIONS: predictive factors for a positive double-balloon enteroscopy after a positive capsule endoscopy were multiple lesions and < 15 days between both procedures. In patients with small bowel bleeding, age over 60 years and the presence of ulcers were also predictive factors.


Asunto(s)
Endoscopía Capsular , Adulto , Anciano , Enteroscopía de Doble Balón , Endoscopía Gastrointestinal , Femenino , Hemorragia Gastrointestinal/diagnóstico por imagen , Hemorragia Gastrointestinal/etiología , Humanos , Intestino Delgado/diagnóstico por imagen , Persona de Mediana Edad , Estudios Retrospectivos
6.
Rev Esp Enferm Dig ; 112(5): 338-342, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32188260

RESUMEN

BACKGROUND: new alternatives for entry site closure (ESC) in per-oral endoscopy myotomy (POEM) and gastric peroral endoscopy myotomy (G-POEM) have appeared. OBJECTIVE: to compare the over-the-scope-clip (OTSC®) and conventional clips (CC) for ESC in POEM and G-POEM. MATERIAL AND METHODS: a retrospective review of a prospective POEM and G-POEM database was performed between January 2015 and August 2019. A description was made of outcomes, using either OTSC® or CC for submucosal tunnel closure. RESULTS: forty-six POEM and 26 G-POEM were included in the study (23/13 per group [CC/OTSC®]). There were no clinical or procedure differences. ESC was performed with 1 OTSC® vs 5 CC and 1 vs 6 (p = 0.01) for POEM and G-POEM, respectively. Adverse events associated with clips were 21.7% vs 13% (p = 0.01) and 7.7% vs 0% (p = 0.02) for CC and OTSC® in POEM and G-POEM, respectively. CONCLUSION: OTSC® represents a safe and effective alternative for entry site closure in POEM and G-POEM cases. Further studies are needed to recommend OTSC® as the first option for submucosal tunnel closure in these procedures.


Asunto(s)
Acalasia del Esófago , Cirugía Endoscópica por Orificios Naturales , Piloromiotomia , Acalasia del Esófago/cirugía , Esfínter Esofágico Inferior , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Instrumentos Quirúrgicos , Resultado del Tratamiento
7.
Rev Esp Enferm Dig ; 112(4): 249-257, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32193939

RESUMEN

INTRODUCTION: the aim of this study was to determine the risk factors for rebleeding following device-assisted enteroscopy therapy of small bowel vascular lesions. METHODS: this is a systematic review and meta-analysis. A literature search was performed from January 2003 to October 2019. All studies reporting on at least one risk factor for bleeding recurrence after endoscopic therapy of small bowel vascular lesions were included. A meta-analysis of those risk factors reported in at least three studies was performed to assess their association with rebleeding. The OR and 95 % CI were used for binary outcome data. Heterogeneity analysis was performed using the Tau and I2 index. If I2 > 20 %, potential sources of heterogeneity were identified by sensitivity analyses and a random-effect model was used. RESULTS: the search identified a total of 572 articles and 35 full-text records were assessed for eligibility after screening. Finally, eight studies that included 548 patients were selected. The overall median rebleeding rate was 38.5 % (range: 10.9-53.3 %) with a median follow-up of 24.5 months. Female sex (OR: 1.96, 95 % CI: 1.14-3.37, p = 0.01, I2 = 0 %), Osler-Weber syndrome (OR: 4.35, 95 % CI: 1.22-15.45, p = 0.02, I2 = 0 %) and cardiac disease (OR: 1.89, 95 % CI: 1.12-2.97, p = 0.005, I2: 0 %) were associated with rebleeding. According to the sensitivity analysis, overt bleeding (OR: 2.13, 95 % CI: 1.22-3.70, p = 0.007, I2 = 0 %), multiple lesions (OR: 4.57, 95 % CI: 2.04-10.22, p < 0.001, I2 = 0 %) and liver cirrhosis (OR: 2.61, 95 % CI: 1.11-6.13, p = 0.03, I2 = 0 %) were also predictors for rebleeding. CONCLUSIONS: patient characteristics and comorbidities should be considered for follow-up patient management after effective device-assisted endoscopic therapy, as they can predict rebleeding.


Asunto(s)
Hemorragia Gastrointestinal , Intestino Delgado , Endoscopía Gastrointestinal , Femenino , Hemorragia Gastrointestinal/epidemiología , Hemorragia Gastrointestinal/etiología , Humanos , Recurrencia , Factores de Riesgo , Resultado del Tratamiento
8.
Rev Esp Enferm Dig ; 112(4): 258-261, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32122147

RESUMEN

INTRODUCTION: carbon dioxide (CO2) insufflation during enteroscopy reduces procedure time and subsequent symptoms and increases the insertion depth compared with room air. In colonoscopy, the water-exchange (WE) technique is associated with less pain compared with CO2 insufflation. The WE technique is not well studied in enteroscopy. The aim of this study was to compare the efficacy and safety of enteroscopy with WE and CO2. METHODS: a prospective, comparative and observational study was performed of double balloon enteroscopies (DBE) that were randomized in two groups. The first group used WE while the second group used CO2 insufflation. The data collected was evaluated via univariate analysis and multiple logistic regression (variables with p ≤ 0.10 according to the univariate analysis). RESULTS: forty-six DBE were included; 23 in each arm. The median age of cases was 63.5 years and 37% were female. There were no statistical differences between the groups with regard to the access route, findings, therapy and complications. Four patients (20%) in the CO2 group had adverse events (abdominal distension and pain) and one in the WE group (nausea), which was not statistically significant. The median insertion depth was greater in the CO2 group; 260 cm vs 160 cm (p = 0.048). Multiple logistic regression showed a statistically significant difference in the insertion depth using CO2 insufflation (OR 1.009, 1.001-1.017; p = 0.034). CONCLUSIONS: DBE with a CO2 insufflation technique and WE are safe with a greater insertion depth with CO2.


Asunto(s)
Dióxido de Carbono , Insuflación , Colonoscopía , Femenino , Humanos , Insuflación/efectos adversos , Persona de Mediana Edad , Estudios Prospectivos , Agua
9.
Rev Esp Enferm Dig ; 112(2): 118-120, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31960686

RESUMEN

BACKGROUND: the prevalence of small bowel (SB) polyps is unknown in acromegaly patients. OBJECTIVE: to evaluate the prevalence of polyps/tumors in SB of acromegaly patients. MATERIAL: this was a prospective and observational study that compared the prevalence of polyps/tumors using capsule endoscopy with a standard protocol in asymptomatic acromegaly patients and non-acromegaly patients, with abdominal pain, diarrhea or anemia. RESULTS: one hundred and eighty-three cases were included (61 acromegaly and 122 non-acromegaly). Polyps were found in six (9.8%) and three (2.5%) patients, respectively (RR: 4 [95% CI, 1.03-15.45; p = 0.038]). There were no differences in the tumors (n = 4, 6.6% vs n = 7, 5.7%). CONCLUSIONS: acromegaly may be associated with more polyps in SB.


Asunto(s)
Acromegalia , Endoscopía Capsular , Acromegalia/complicaciones , Acromegalia/diagnóstico por imagen , Acromegalia/epidemiología , Humanos , Pólipos Intestinales/complicaciones , Pólipos Intestinales/diagnóstico por imagen , Pólipos Intestinales/epidemiología , Intestino Delgado/diagnóstico por imagen , Intestino Delgado/patología , Estudios Prospectivos
10.
Rev Esp Enferm Dig ; 111(9): 696-698, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31333041

RESUMEN

BACKGROUND: the relationship between small bowel transit time (SBTT) of the capsule endoscopy (CE) and the diagnosis of small bowel bleeding (SBB) is controversial. OBJECTIVE: to evaluate the relationship between SBTT and CE and the identification of SBB. MATERIAL AND METHODS: CE was divided according to SBTT into < 4 hours and ≥ 4 hours. RESULTS: CE with SBTT ≥ 4 hours identified more angioectasias (p = 0.023), single lesions (p = 0.029) and jejunal lesions (p = 0.001) with an OR of 3.13 (95% CI, 1.61-6.10, p = 0.001) to identify the cause of SBB. CONCLUSIONS: CE SBTT of ≥ 4 hours increases the diagnosis of SBB.


Asunto(s)
Angiodisplasia/diagnóstico por imagen , Endoscopía Capsular/estadística & datos numéricos , Hemorragia Gastrointestinal/diagnóstico por imagen , Tránsito Gastrointestinal , Adulto , Anciano , Angiodisplasia/complicaciones , Estudios Transversales , Enfermedades Duodenales/complicaciones , Enfermedades Duodenales/diagnóstico por imagen , Femenino , Hemorragia Gastrointestinal/etiología , Humanos , Enfermedades del Íleon/complicaciones , Enfermedades del Íleon/diagnóstico por imagen , Enfermedades del Yeyuno/complicaciones , Enfermedades del Yeyuno/diagnóstico por imagen , Modelos Logísticos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Úlcera/complicaciones , Úlcera/diagnóstico por imagen
12.
Endoscopy ; 49(12): 1209-1218, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28898921

RESUMEN

Background and study aims Peroral endoscopic myotomy (POEM) is an excellent endoscopic treatment for achalasia. Clinical and manometric parameters are used for evaluation and follow-up. However, clinical success does not guarantee high quality of life (QoL) scores, generating doubts about their direct relationship. We aimed to evaluate QoL scores before and after POEM at medium and long term, to evaluate differences between achalasia subtypes and find which factors related to low QoL scores. Patients and methods Achalasia-confirmed patients undergoing POEM between February 2012 and November 2016. and completing at least 1 year of follow-up, were included. Assessment before and at 1, 6, 12, 24, 36 and 48 months after POEM employed manometry, barium series, Eckardt score, and the AE-18 health-related QoL scale. Demographic, clinical, and procedure characteristics were documented, with comparisons between subgroups. Multiple logistic regression analysis was done. Results 65 of 88 patients were included (38 women, 27 men; median age 47 years, interquartile range [IQR] 20 - 81), and 50 (76.9 %) completed 4 years of follow-up. Eckardt score improved (median, preprocedure 10 vs. post-procedure 2; P = 0.002) and this persisted. There was initial improvement in median integrated relaxation pressure (IRP) (29.4 mmHg [16 - 55] vs. 10.3 mmHg [3 - 18]; P = 0.000) and median QoL scores (40 vs. 68 at 1 month; P = 0.002); however IRP increased and QoL scores decreased. Men with confirmed type III achalasia had low QoL scores. Conclusions All patients had significant clinical improvement after POEM, with medium- to long-term persistence. Though quality of life and IRP initially improved, they deteriorated in the long term. Male sex and type III achalasia seem to be associated with low QoL scores.


Asunto(s)
Acalasia del Esófago/cirugía , Esfínter Esofágico Inferior/fisiopatología , Esfínter Esofágico Inferior/cirugía , Miotomía de Heller , Calidad de Vida , Adulto , Anciano , Anciano de 80 o más Años , Sulfato de Bario , Medios de Contraste , Endoscopía Gastrointestinal , Acalasia del Esófago/diagnóstico por imagen , Acalasia del Esófago/fisiopatología , Femenino , Miotomía de Heller/métodos , Humanos , Masculino , Manometría , Persona de Mediana Edad , Relajación Muscular , Periodo Posoperatorio , Periodo Preoperatorio , Presión , Radiografía , Factores Sexuales , Factores de Tiempo , Adulto Joven
13.
Rev Esp Enferm Dig ; 109(3): 213-214, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28256143

RESUMEN

Is a case report of a patient with overt obscure gastrointestinal bleeding due to a mesenteric hemolymphangioma with infiltration to jejunum. Diagnosed by capsule endoscopy and treated with double-balloon enteroscopy and surgery.


Asunto(s)
Hemorragia Gastrointestinal/etiología , Hemangioma/complicaciones , Neoplasias del Yeyuno/complicaciones , Linfangioma/complicaciones , Endoscopía Gastrointestinal , Femenino , Hemorragia Gastrointestinal/diagnóstico por imagen , Hemangioma/cirugía , Humanos , Neoplasias del Yeyuno/cirugía , Linfangioma/cirugía , Persona de Mediana Edad
16.
Bol Med Hosp Infant Mex ; 80(5): 296-301, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37963298

RESUMEN

BACKGROUND: The use of pancreatic prostheses in children with acute recurrent pancreatitis (ARP) and chronic pancreatitis (CP) has evolved. The main established indication is the treatment of persistent abdominal pain. This study aimed to evaluate the efficacy of pancreatic stenting for refractory abdominal pain in pediatric patients with ARP and CP. METHODS: We conducted a retrospective case series study. We included patients under 16 years of age diagnosed with ARP and CP in the study. Endoscopic retrograde cholangiopancreatography (ERCP) was performed with the insertion of one and later two pancreatic stents. We evaluated abdominal symptoms before and after treatment, number of changes, duration of treatment, and complications with follow-up at 24 months and after withdrawal. RESULTS: Nine patients with ARP and CP were included in the study: six with undetermined etiology and three with pancreas divisum. The mean age was 12.4 years. Prosthesis placement relieved abdominal pain in 100% of cases, with 3.2 replacement sessions every 6.2 months for 27.4 months, and mild complications (15.7%). One patient experienced pain on removal of the prosthesis and required bypass surgery. CONCLUSION: Pancreatic stent placement in patients with refractory abdominal pain with ARP and CP proved to be effective and safe, providing medium-term symptom relief and minimal complications.


INTRODUCCIÓN: El uso de prótesis pancreáticas en niños con pancreatitis aguda recurrente (PAR) y crónica (PC) ha evolucionado. La principal indicación establecida es el tratamiento del dolor abdominal persistente. El objetivo de este estudio fue evaluar la eficacia del uso prótesis pancreática para el dolor abdominal refractario en pacientes pediátricos con PAR y PC, sin respuesta a manejo conservador. MÉTODOS: Se llevó a cabo un estudio retrospectivo de serie de casos. Se incluyeron pacientes menores de 16 años con diagnóstico de PAR y PC. Se realizó una colangio pancreatografía retrograda endoscópica (CPRE) para introducir inicialmente una y posteriormente dos prótesis pancreáticas. Se evaluaron síntomas abdominales antes y después del tratamiento, número de recambios, duración del tratamiento y complicaciones con seguimiento a 24 meses y posterior a su retiro. RESULTADOS: Se incluyeron 9 pacientes con PAR y PC: seis de etiología no determinada y tres con páncreas divisum. La edad promedio fue de 12.4 años. La colocación de prótesis alivió el dolor abdominal en el 100%, con 3.2 sesiones de recambio cada 6.2 meses en 27.4 meses, y complicaciones leves (15.7%). Un paciente presentó dolor al retirar las prótesis y requirió cirugía derivativa. CONCLUSIONES: El uso de prótesis pancreática en pacientes con dolor abdominal refractario con PAR y PC demostró ser eficaz y seguro al aliviar los síntomas a mediano plazo con mínimas complicaciones.


Asunto(s)
Pancreatitis Crónica , Humanos , Niño , Estudios Retrospectivos , Resultado del Tratamiento , Pancreatitis Crónica/complicaciones , Pancreatitis Crónica/cirugía , Dolor Abdominal/etiología , Stents
17.
GE Port J Gastroenterol ; 29(2): 106-110, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35497672

RESUMEN

Introduction: The diagnostic yield (DY) of small-bowel capsule endoscopy (SBCE) varies considerably according to its indication. Some strategies have been used to increase DY with varying results. The intention of this study was to identify whether evaluation of the SBCE recordings by a second reviewer can increase DY and change patient management. Methods: One hundred SBCEs with different indications, already read by an endoscopist were read by a second blinded endoscopist. When the results of the 2 readings were different, the images were discussed by the endoscopists; if no consensus was reached, they took the opinion of a third endoscopist into account. All the participating endoscopists had experience in reading SBCEs (i.e., >50 per year). The SBCE findings were divided into positive (vascular lesions, ulcers, and tumors), equivocal (erosions or red spots), and negative. The interobserver agreement and the increase in DY were assessed as well as the percentage of false-negatives (FNs) in the first evaluation. Results: The indications for SBCE were small-bowel bleeding (SBB) in 48 cases, Crohn's disease (CD) in 30, and other causes (iron-deficiency anemia, small-bowel tumors, and diarrhea) in 22. There was substantial interobserver agreement between evaluations (κ = 0.79). The findings in the first evaluation were positive in 60%, equivocal in 20% and, negative in 20%. In the second evaluation, 66% were positive, 18% were equivocal, and 16% were negative. The increase in DY with the second reading was 6% (p = 0.380), i.e., 6.3% for SBB, 4.4% for CD and 9.2% for other indications, resulting in a change in management of 4% of the patients. FNs in the first SBCE reading were found in 4% of the SBCEs. Discussion: A second evaluation of the SBCE recordings identified significant pathology that the first evaluation had missed, resulting in a nonsignificant 6% increase in DY and a change in the management of 4% of the patients.


Introdução: O rendimento diagnóstico (DY) da enteroscopia por cápsula (SBCE) varia consideravelmente de acordo com as suas indicações. Foram estudadas algumas estratégias para melhorar o DY, com resultados variados. O objetivo deste estudo é avaliar se uma segunda leitura de registos de enteroscopia por cápsula por um segundo endoscopista pode melhorar o DY e alterar o manejo dos doentes. Métodos: 100 SBCE realizadas por indicações variadas, previamente avaliadas por um endoscopista, foram reavaliadas por um segundo endoscopista cego para a primeira leitura. Na presença de resultados discordantes nas 2 leituras, as imagens foram discutidas pelos 2 endoscopistas, e por um terceiro na ausência de consenso entre os 2 primeiros. Todos os endoscopistas são experientes na leitura de SBCE (>50 SBCE/ano). Os achados foram categorizados em positivos (lesões vasculares, úlceras e tumores), equívocos (erosões e pontos vermelhos) e negativos. Foi avaliada a concordância inter-observador e o aumento do DY, bem como a percentagem de falsos negativos da primeira avaliação. Resultados: As indicações para SBCE foram hemorragia do intestino delgado (SBB) em 48 casos, doença de Crohn (CD) em 30 e outras causas (anemia por défice de ferro, pesquisa de tumores do intestino delgado e diarreia) em 22. A concordância inter-observador foi substancial (k = 0.79). Os achados da primeira avaliação foram positivos em 60%, equívocos em 20% e negativos em 20%, enquanto na segunda avaliação foram positivos em 66%, equívocos em 18% e negativos em 16%. O aumento de DY foi de 6% com a segunda leitura (p = 0.38), sendo 6.3% para SBB, 4.4% para CD e 9.2% para outras indicações, resultando numa alteração no manejo de 4% dos doentes. Foram identificados falsos negativos na primeira avaliação em 4% das SBCE. Conclusão: A segunda avaliação dos registos de SBCE identificou patologia significativa previamente não identificada, resultando num aumento não significativo de 6% do DY e numa alteração no manejo de 4% dos doentes.

20.
Artículo en Inglés | MEDLINE | ID: mdl-33436482

RESUMEN

BACKGROUND AND AIMS: Digestive endoscopy is considered a high-risk procedure for COVID-19. Recommendations have been made for its practice during the pandemic. This study was conducted to determine adherence to recommendations for endoscopy practice during the COVID-19 pandemic in Latin America (LA). METHODS: A survey was conducted of endoscopists from LA consisting of 43 questions for the evaluation of four items: general and sociodemographic features, and preprocedure, intraprocedure and postprocedure aspects. RESULTS: A response was obtained from 338 endoscopists (response rate 34.5%) across 15 countries in LA. In preprocedure aspects (hand washing, use of face masks for patients, respiratory triage area, training for the placement/removal of personal protective equipment (PPE) and availability of specific area for the placement/removal of PPE), there was adherence in <75%. Regarding postprocedure aspects, 77% (261/338) had reused PPE, mainly the N95 respirator or higher, and this was with a standardised decontamination procedure only in 32% (108/338) of the time. Postprocedure room decontamination was carried out by 47% on >75% of occasions. In relationship to intraprocedure aspects (knowledge of risk and type of endoscopic procedures, use of PPE, airway management in patients and infrastructure), there was adherence in >75% for all the parameters and 78% of endoscopists only performed emergencies or time-sensitive procedures. CONCLUSIONS: Adherence to the recommendations for endoscopy practice during the COVID-19 pandemic is adequate in the intraprocedure aspect. However, it is deficient in the preprocedure and postprocedure aspects.


Asunto(s)
COVID-19 , Endoscopía Gastrointestinal , Adhesión a Directriz , Guías de Práctica Clínica como Asunto , Adulto , COVID-19/epidemiología , COVID-19/prevención & control , Femenino , Encuestas de Atención de la Salud , Humanos , Control de Infecciones/métodos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , América Latina/epidemiología , Masculino , Persona de Mediana Edad , Pandemias , Equipo de Protección Personal , Estudios Prospectivos , Factores de Riesgo , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA