Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Med Imaging ; 24(1): 49, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38395772

RESUMEN

PURPOSE: Unenhanced abdominal CT constitutes the diagnostic standard of care in suspected urolithiasis. Aiming to identify potential for radiation dose reduction in this frequent imaging task, this experimental study compares the effect of spectral shaping and tube voltage modulation on image quality. METHODS: Using a third-generation dual-source CT, eight cadaveric specimens were scanned with varying tube voltage settings with and without tin filter application (Sn 150, Sn 100, 120, 100, and 80 kVp) at three dose levels (3 mGy: standard; 1 mGy: low; 0.5 mGy: ultralow). Image quality was assessed quantitatively by calculation of signal-to-noise ratios (SNR) for various tissues (spleen, kidney, trabecular bone, fat) and subjectively by three independent radiologists based on a seven-point rating scale (7 = excellent; 1 = very poor). RESULTS: Irrespective of dose level, Sn 100 kVp resulted in the highest SNR of all tube voltage settings. In direct comparison to Sn 150 kVp, superior SNR was ascertained for spleen (p ≤ 0.004) and kidney tissue (p ≤ 0.009). In ultralow-dose scans, subjective image quality of Sn 100 kVp (median score 3; interquartile range 3-3) was higher compared with conventional imaging at 120 kVp (2; 2-2), 100 kVp (1; 1-2), and 80 kVp (1; 1-1) (all p < 0.001). Indicated by an intraclass correlation coefficient of 0.945 (95% confidence interval: 0.927-0.960), interrater reliability was excellent. CONCLUSIONS: In abdominal CT with maximised dose reduction, tin prefiltration at 100 kVp allows for superior image quality over Sn 150 kVp and conventional imaging without spectral shaping.


Asunto(s)
Estaño , Tomografía Computarizada por Rayos X , Humanos , Reproducibilidad de los Resultados , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Abdomen/diagnóstico por imagen
2.
Radiology ; 308(1): e230084, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37404154

RESUMEN

Background The triple combination of the cystic fibrosis transmembrane regulator (CFTR) modulators elexacaftor, tezacaftor, and ivacaftor (hereafter, elexacaftor/tezacaftor/ivacaftor) has a positive effect on lung function in patients with cystic fibrosis (CF). Purpose To compare three-dimensional (3D) ultrashort echo time (UTE) MRI functional lung data to common functional lung parameters in assessing lung function in patients with CF undergoing elexacaftor/tezacaftor/ivacaftor therapy. Materials and Methods In this prospective feasibility study, 16 participants with CF consented to undergo pulmonary MRI with a breath-hold 3D UTE sequence at baseline (April 2018-June 2019) and follow-up (April-July 2021). Eight participants received elexacaftor/tezacaftor/ivacaftor after baseline, and eight participants with unchanged treatment served as the control group. Lung function was assessed with body plethysmography and lung clearance index (LCI). Image-based functional lung parameters, such as ventilation inhomogeneity and ventilation defect percentage (VDP), were calculated from signal intensity change between MRI scans at inspiration and expiration. Metrics at baseline and follow-up were compared within groups (permutation test), correlation was tested (Spearman rank correlation), and 95% CIs were calculated (bootstrapping technique). Results MRI ventilation inhomogeneity correlated with LCI at baseline (r = 0.92, P < .001) and follow-up (r = 0.81, P = .002). Mean MRI ventilation inhomogeneity (baseline, 0.74 ± 0.15 [SD]; follow-up, 0.64 ± 0.11; P = .02) and mean VDP (baseline, 14.1% ± 7.4; follow-up, 8.5% ± 3.3; P = .02) decreased from baseline to follow-up in the treatment group. Lung function was stable over time (mean LCI: 9.3 turnovers ± 4.1 at baseline vs 11.5 turnovers ± 7.4 at follow-up; P = .34) in the control group. In all participants, correlation of forced expiratory volume in 1 second with MRI ventilation inhomogeneity was good at baseline (r = -0.61, P = .01) but poor during follow-up (r = -0.06, P = .82). Conclusion Noncontrast 3D UTE lung MRI functional parameters of ventilation inhomogeneity and VDP can be used to assess lung function over time in patients with CF and can add regional information to established global parameters, such as LCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.


Asunto(s)
Fibrosis Quística , Humanos , Fibrosis Quística/diagnóstico por imagen , Fibrosis Quística/tratamiento farmacológico , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Estudios Prospectivos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Mutación
3.
Radiology ; 306(3): e221200, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36346312

RESUMEN

Background Posttraumatic CT imaging of the elbow can be challenging when patient mobility is limited. Gantry-free cone-beam CT (CBCT) with a twin robotic radiography system offers greater degrees of positioning freedom for three-dimensional elbow scans over gantry-based multidetector CT (MDCT), but studies analyzing their clinical value remain lacking. Purpose To investigate the diagnostic performance of gantry-free CBCT versus two-dimensional radiography in adults and children with acute elbow trauma. Materials and Methods In a retrospective study, consecutive patients with elbow trauma and positioning difficulty in a gantry-based MDCT who underwent three-dimensional elbow imaging with a gantry-free CBCT after radiography were enrolled between January 2021 and April 2022 at a tertiary care university hospital. Imaging data sets were independently analyzed for fracture presence, articular involvement, and multi-fragment injuries by three radiologists. Diagnostic performance was calculated individually with surgical reports serving as the reference standard. Differences between radiography and CBCT were compared with the McNemar test. Diagnostic confidence was estimated subjectively by each reader, and results were compared with the Wilcoxon signed-rank test. Results Elbow examinations of 23 adults and children (mean age ± SD, 49 years ± 23; seven women) were included with individual assessment of humerus, radius, and ulna (69 bones; 36 fractured). Multi-fragmentary fracture patterns and involvement of articular surfaces were ascertained in 28 and 30 bones, respectively. CBCT allowed for similar or higher sensitivity compared with radiography in the assessment of fractures (range for three readers, 94%-100% vs 72%-81%; respectively, P ≤ .06-.008), articular surface involvement (90%-97% vs 73%-87%; P ≤ .25), and multi-fragmentary patterns (96%-96% vs 68%-75%; P ≤ .03). Readers' diagnostic confidence improved considerably with access to CBCT data sets versus radiographs (all P ≤ .001). For CBCT, the median dose-length product was 70.9 mGy · cm, and the volume CT dose index was 4.4 mGy. Conclusion In acute elbow injuries, gantry-free cone-beam CT enabled improved detection of fractures, articular involvement, and multi-fragmentary patterns compared with two-dimensional radiography. Published under a CC BY 4.0 license Online supplemental material is available for this article.


Asunto(s)
Fracturas Óseas , Procedimientos Quirúrgicos Robotizados , Adulto , Niño , Humanos , Femenino , Dosis de Radiación , Codo , Estudios Retrospectivos , Tomografía Computarizada de Haz Cónico/métodos , Fracturas Óseas/diagnóstico por imagen
4.
J Magn Reson Imaging ; 2023 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-37974498

RESUMEN

BACKGROUND: For time-consuming diffusion-weighted imaging (DWI) of the breast, deep learning-based imaging acceleration appears particularly promising. PURPOSE: To investigate a combined k-space-to-image reconstruction approach for scan time reduction and improved spatial resolution in breast DWI. STUDY TYPE: Retrospective. POPULATION: 133 women (age 49.7 ± 12.1 years) underwent multiparametric breast MRI. FIELD STRENGTH/SEQUENCE: 3.0T/T2 turbo spin echo, T1 3D gradient echo, DWI (800 and 1600 sec/mm2 ). ASSESSMENT: DWI data were retrospectively processed using deep learning-based k-space-to-image reconstruction (DL-DWI) and an additional super-resolution algorithm (SRDL-DWI). In addition to signal-to-noise ratio and apparent diffusion coefficient (ADC) comparisons among standard, DL- and SRDL-DWI, a range of quantitative similarity (e.g., structural similarity index [SSIM]) and error metrics (e.g., normalized root mean square error [NRMSE], symmetric mean absolute percent error [SMAPE], log accuracy error [LOGAC]) was calculated to analyze structural variations. Subjective image evaluation was performed independently by three radiologists on a seven-point rating scale. STATISTICAL TESTS: Friedman's rank-based analysis of variance with Bonferroni-corrected pairwise post-hoc tests. P < 0.05 was considered significant. RESULTS: Both DL- and SRDL-DWI allowed for a 39% reduction in simulated scan time over standard DWI (5 vs. 3 minutes). The highest image quality ratings were assigned to SRDL-DWI with good interreader agreement (ICC 0.834; 95% confidence interval 0.818-0.848). Irrespective of b-value, both standard and DL-DWI produced superior SNR compared to SRDL-DWI. ADC values were slightly higher in SRDL-DWI (+0.5%) and DL-DWI (+3.4%) than in standard DWI. Structural similarity was excellent between DL-/SRDL-DWI and standard DWI for either b value (SSIM ≥ 0.86). Calculation of error metrics (NRMSE ≤ 0.05, SMAPE ≤ 0.02, and LOGAC ≤ 0.04) supported the assumption of low voxel-wise error. DATA CONCLUSION: Deep learning-based k-space-to-image reconstruction reduces simulated scan time of breast DWI by 39% without influencing structural similarity. Additionally, super-resolution interpolation allows for substantial improvement of subjective image quality. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 1.

5.
Eur Radiol ; 33(11): 7818-7829, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37284870

RESUMEN

OBJECTIVES: While established for energy-integrating detector computed tomography (CT), the effect of virtual monoenergetic imaging (VMI) and iterative metal artifact reduction (iMAR) in photon-counting detector (PCD) CT lacks thorough investigation. This study evaluates VMI, iMAR, and combinations thereof in PCD-CT of patients with dental implants. MATERIAL AND METHODS: In 50 patients (25 women; mean age 62.0 ± 9.9 years), polychromatic 120 kVp imaging (T3D), VMI, T3DiMAR, and VMIiMAR were compared. VMIs were reconstructed at 40, 70, 110, 150, and 190 keV. Artifact reduction was assessed by attenuation and noise measurements in the most hyper- and hypodense artifacts, as well as in artifact-impaired soft tissue of the mouth floor. Three readers subjectively evaluated artifact extent and soft tissue interpretability. Furthermore, new artifacts through overcorrection were assessed. RESULTS: iMAR reduced hyper-/hypodense artifacts (T3D 1305.0/-1418.4 versus T3DiMAR 103.2/-46.9 HU), soft tissue impairment (106.7 versus 39.7 HU), and image noise (16.9 versus 5.2 HU) compared to non-iMAR datasets (p ≤ 0.001). VMIiMAR ≥ 110 keV subjectively enhanced artifact reduction over T3DiMAR (p ≤ 0.023). Without iMAR, VMI displayed no measurable artifact reduction (p ≥ 0.186) and facilitated no significant denoising over T3D (p ≥ 0.366). However, VMI ≥ 110 keV reduced soft tissue impairment (p ≤ 0.009). VMIiMAR ≥ 110 keV resulted in less overcorrection than T3DiMAR (p ≤ 0.001). Inter-reader reliability was moderate/good for hyperdense (0.707), hypodense (0.802), and soft tissue artifacts (0.804). CONCLUSION: While VMI alone holds minimal metal artifact reduction potential, iMAR post-processing enabled substantial reduction of hyperdense and hypodense artifacts. The combination of VMI ≥ 110 keV and iMAR resulted in the least extensive metal artifacts. CLINICAL RELEVANCE: Combining iMAR with VMI represents a potent tool for maxillofacial PCD-CT with dental implants achieving substantial artifact reduction and high image quality. KEY POINTS: • Post-processing of photon-counting CT scans with an iterative metal artifact reduction algorithm substantially reduces hyperdense and hypodense artifacts arising from dental implants. • Virtual monoenergetic images presented only minimal metal artifact reduction potential. • The combination of both provided a considerable benefit in subjective analysis compared to iterative metal artifact reduction alone.


Asunto(s)
Artefactos , Implantes Dentales , Humanos , Femenino , Persona de Mediana Edad , Anciano , Reproducibilidad de los Resultados , Metales , Tomografía Computarizada por Rayos X/métodos , Algoritmos
6.
Arch Orthop Trauma Surg ; 143(12): 7097-7105, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37639044

RESUMEN

INTRODUCTION: The AMADEUS (Area Measurement And DEpth and Underlying Structures) score has advanced to a commonly used tool for MRI-based chondral defect severity grading prior to cartilage knee surgery. It was the intention of this study to assess the AMADEUS for a potential correlation with clinical data by patient-reported outcome measures (PROMs). METHODS: A total of 51 patients undergoing ACI (autologous chondrocyte implantation) between 2016 and 2022 were found eligible and retrospectively analyzed. All patients were registered in the German Cartilage Registry prior to surgery and follow-up data were collected using the Knee Osteoarthritis Outcome score (KOOS), the International Knee Documentation Committee (IKDC) Form and the numeric rating scale (NRS). Pre-operative MRI images were scored by three raters using the AMADEUS classification system, and an overall AMADEUS score was calculated which was subsequently correlated with pre- and post-operative PROMs. RESULTS: Mean patient age was 32.67 ± 8.37 years and mean defect size area 343.04 mm2 ± 139.45 mm2. No correlative capacity of the pre- and postoperative IKDC, KOOS or NRS scores was found with the AMADEUS final score or any of its subscores. From the pre- to postoperative visit, a significant improvement of the PROMs (IKDC: 45.53 ± 21.00 vs. 59.83 ± 17.93, p = 0.04; KOOS Pain: 58.00 ± 16.70 vs. 76.06 ± 19.20, p = 0.03; KOOS ADL: 64.17 ± 18.76 vs. 82.11 ± 16.68, p < 0.01; KOOS Sports: 26.11 ± 18.52 vs. 50.56 ± 23.94, p = 0.01; KOOS QOL: 25.50 ± 14.26 ± 45.28 ± 19.03, p = 0.00) was found. Intraclass correlation coefficients showed an overall good interrater agreement for the AMADEUS total score (ICC = 0.75). CONCLUSIONS: Study results suggest no correlative capacity of the AMADEUS with routinely used PROMs in patients undergoing ACI. Therefore, radiographically assessed cartilage defect characteristics poorly translate to pre- and postoperative patient-reported outcome data.


Asunto(s)
Enfermedades de los Cartílagos , Cartílago Articular , Osteoartritis de la Rodilla , Humanos , Adulto Joven , Adulto , Condrocitos , Cartílago Articular/cirugía , Estudios Retrospectivos , Calidad de Vida , Trasplante Autólogo/métodos , Articulación de la Rodilla/cirugía , Enfermedades de los Cartílagos/cirugía , Osteoartritis de la Rodilla/cirugía , Dolor , Sistema de Registros
7.
Magn Reson Med ; 87(2): 972-983, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34609026

RESUMEN

PURPOSE: Image acquisition and subsequent manual analysis of cardiac cine MRI is time-consuming. The purpose of this study was to train and evaluate a 3D artificial neural network for semantic segmentation of radially undersampled cardiac MRI to accelerate both scan time and postprocessing. METHODS: A database of Cartesian short-axis MR images of the heart (148,500 images, 484 examinations) was assembled from an openly accessible database and radial undersampling was simulated. A 3D U-Net architecture was pretrained for segmentation of undersampled spatiotemporal cine MRI. Transfer learning was then performed using samples from a second database, comprising 108 non-Cartesian radial cine series of the midventricular myocardium to optimize the performance for authentic data. The performance was evaluated for different levels of undersampling by the Dice similarity coefficient (DSC) with respect to reference labels, as well as by deriving ventricular volumes and myocardial masses. RESULTS: Without transfer learning, the pretrained model performed moderately on true radial data [maximum number of projections tested, P = 196; DSC = 0.87 (left ventricle), DSC = 0.76 (myocardium), and DSC =0.64 (right ventricle)]. After transfer learning with authentic data, the predictions achieved human level even for high undersampling rates (P = 33, DSC = 0.95, 0.87, and 0.93) without significant difference compared with segmentations derived from fully sampled data. CONCLUSION: A 3D U-Net architecture can be used for semantic segmentation of radially undersampled cine acquisitions, achieving a performance comparable with human experts in fully sampled data. This approach can jointly accelerate time-consuming cine image acquisition and cumbersome manual image analysis.


Asunto(s)
Corazón , Semántica , Corazón/diagnóstico por imagen , Ventrículos Cardíacos , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Redes Neurales de la Computación
8.
Eur Radiol ; 32(2): 1276-1284, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34347156

RESUMEN

OBJECTIVES: Vessel wall enhancement (VWE) may be commonly seen on MRI images of asymptomatic subjects. This study aimed to characterize the VWE of the proximal internal carotid (ICA) and vertebral arteries (VA) in a non-vasculitic elderly patient cohort. METHODS: Cranial MRI scans at 3 Tesla were performed in 43 patients (aged ≥ 50 years) with known malignancy for exclusion of cerebral metastases. For vessel wall imaging (VWI), a high-resolution compressed-sensing black-blood 3D T1-weighted fast (turbo) spin echo sequence (T1 CS-SPACE prototype) was applied post gadolinium with an isotropic resolution of 0.55 mm. Bilateral proximal intradural ICA and VA segments were evaluated for presence, morphology, and longitudinal extension of VWE. RESULTS: Concentric VWE of the proximal intradural ICA was found in 13 (30%) patients, and of the proximal intradural VA in 39 (91%) patients. Mean longitudinal extension of VWE after dural entry was 13 mm in the VA and 2 mm in the ICA. In 14 of 39 patients (36%) with proximal intradural VWE, morphology of VWE was suggestive of the mere presence of vasa vasorum. In 25 patients (64 %), morphology indicated atherosclerotic lesions in addition to vasa vasorum. CONCLUSIONS: Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in elderly subjects. Concentric VWE in these locations should not be confused with large artery vasculitis. Distal to these segments, VWE may be more likely related to pathologic conditions such as vasculitis. KEY POINTS: • Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in non-vasculitic elderly people. • Concentric enhancement within the proximal 2 mm of the intradural ICA and within the proximal 13 mm of the intradural VA portions should not be misinterpreted as vasculitis. • Distal of this, VWE is likely related to pathologic conditions, in case of concentric VWE suggestive of vasculitis.


Asunto(s)
Vasa Vasorum , Vasculitis , Anciano , Arterias Cerebrales , Humanos , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Vasa Vasorum/diagnóstico por imagen
9.
AJR Am J Roentgenol ; 218(4): 716-727, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34755521

RESUMEN

BACKGROUND. Head and neck CT can be limited by dental hardware artifact. Both postprocessing-based iterative metal artifact reduction (IMAR) and virtual monoenergetic imaging (VMI) reconstruction in dual-energy CT (DECT) can reduce metal artifact. Their combination is poorly described for single-source DECT systems. OBJECTIVE. The purpose of this study was to compare metal artifact reduction between VMI, IMAR, and their combination (VMIIMAR) in split-filter single-source DECT of patients with severe dental hardware artifact. METHODS. This retrospective study included 44 patients (nine woman, 35 men; mean age, 66.0 ± 10.4 years) who underwent head and neck CT and had severe dental hardware artifact. Standard, VMI, IMAR, and VMIIMAR images were generated; VMI and VMIIMAR were performed at 40, 70, 100, 120, 150, and 190 keV. ROIs were placed to measure corrected attenuation in pronounced hyperattenuating and hypoattenuating artifacts and artifact-impaired soft tissue and to measure corrected artifact-impaired soft-tissue noise. Two radiologists independently assessed soft-tissue interpretability (1-5 scale), and pooled ratings were analyzed. Readers selected the preferred reconstruction for each patient. RESULTS. Mean hyperattenuating artifact-corrected attenuation was 521.0 HU for standard imaging, 496.4-892.2 HU for VMI, 48.2 HU for IMAR, and 32.8-91.0 HU for VMIIMAR. Mean hypoattenuating artifact-corrected attenuation was -455.1 HU for standard imaging, -408.5 to -679.9 HU for VMI, -37.3 for IMAR, and -17.8 to -36.9 HU for VMIIMAR. Mean artifact-impaired soft tissue-corrected attenuation was 10.8 HU for standard imaging, -0.6 to 24.9 HU for VMI, 4.3 HU for IMAR, and -2.0 to 7.8 HU for VMIIMAR. Mean artifact-impaired soft tissue-corrected noise was 58.7 HU for standard imaging, 38.2 to 129.7 HU for VMI, 11.0 HU for IMAR, and 5.8 to 45.6 HU for VMIIMAR. Median soft-tissue interpretability was 1.2 for standard imaging, 1.1-1.2 for VMI, 3.7 for IMAR, and 2.0-3.8 for VMIIMAR. Artifact-impaired soft tissue-corrected attenuation and soft-tissue interpretability significantly improved (p < .05) for VMIIMAR versus IMAR only at 100 keV. The two readers preferred VMIIMAR at 100 keV in 56.8% and 59.1% of examinations. CONCLUSION. For reducing severe artifact due to dental material, IMAR has greater effect than VMI. Though the results for IMAR and VMIIMAR were similar overall, VMIIMAR had a small benefit at 100 keV. CLINICAL IMPACT. VMI and IMAR techniques in split-filter DECT may be combined for clinical head and neck imaging to reduce artifact from dental hardware and improve image quality.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Anciano , Algoritmos , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
10.
BMC Med Imaging ; 22(1): 90, 2022 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-35578260

RESUMEN

BACKGROUND: Endovascular revascularization has become the first-line treatment of chronic mesenteric ischemia (CMI). The qualitative visual analysis of digital subtraction angiography (DSA) is dependent on observer experience and prone to interpretation errors. We evaluate the feasibility of 2D-Perfusion Angiography (2D-PA) for objective, quantitative treatment response assessment in CMI. METHODS: 49 revascularizations in 39 patients with imaging based evidence of mesenteric vascular occlusive disease and clinical signs of CMI were included in this retrospective study. To assess perfusion changes by 2D-PA, DSA-series were post-processed using a dedicated, commercially available software. Regions of interest (ROI) were placed in the pre- and post-stenotic artery segment. In aorto-ostial disease, the inflow ROI was positioned at the mesenteric artery orifice. The ratios outflow to inflow ROI for peak density (PD), time to peak and area-under-the-curve (AUC) were computed and compared pre- and post-interventionally. We graded motion artifacts by means of a four-point scale. Feasibility of 2D-PA and changes of flow parameters were evaluated. RESULTS: Motion artifacts due to a mobile vessel location beneath the diaphragm or within the mesenteric root, branch vessel superimposition and inadequate contrast enhancement at the inflow ROI during manually conducted DSA-series via selective catheters owing to steep vessel angulation, necessitated exclusion of 26 measurements from quantitative flow evaluation. The feasibility rate was 47%. In 23 technically feasible assessments, PDoutflow/PDinflow increased by 65% (p < 0.001) and AUCoutflow/AUCinflow increased by 85% (p < 0.001). The time to peak density values in the outflow ROI accelerated only minimally without reaching statistical significance. Age, BMI, target vessel (celiac trunk, SMA or IMA), stenosis location (ostial or truncal), calcification severity, plaque composition or the presence of a complex stenosis did not reach statistical significance in their distribution among the feasible and non-feasible group (p > 0.05). CONCLUSIONS: Compared to other vascular territories and indications, the feasibility of 2D-PA in mesenteric revascularization for CMI was limited. Unfavorable anatomic conditions contributed to a high rate of inconclusive 2D-PA results.


Asunto(s)
Isquemia Mesentérica , Angiografía de Substracción Digital/métodos , Enfermedad Crónica , Constricción Patológica , Estudios de Factibilidad , Humanos , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/cirugía , Perfusión , Estudios Retrospectivos , Resultado del Tratamiento
11.
BMC Med Imaging ; 22(1): 19, 2022 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-35120493

RESUMEN

BACKGROUND: To analyze the benefit of color-coded summation images in the assessment of target lumen perfusion in patients with aortic dissection and malperfusion syndrome before and after fluoroscopy-guided aortic fenestration. METHODS: Between December 2011 and April 2020 25 patients with Stanford type A (n = 13) or type B dissection (n = 12) and malperfusion syndromes were treated with fluoroscopy-guided fenestration of the dissection flap using a re-entry catheter. The procedure was technically successful in 100% of the cases and included additional iliofemoral stent implantation in four patients. Intraprocedural systolic blood pressure measurements for gradient evaluation were performed in 19 cases. Post-processed color-coded DSA images were obtained from all DSA series before and following fenestration. Differences in time to peak (dTTP) values in the compromised aortic lumen and transluminal systolic blood pressure gradients were analyzed retrospectively. Correlation analysis between dTTP and changes in blood pressure gradients was performed. RESULTS: Mean TTP prior to dissection flap fenestration was 6.85 ± 1.35 s. After fenestration, mean TTP decreased significantly to 4.96 ± 0.94 s (p < 0.001). Available systolic blood pressure gradients between the true and the false lumen were reduced by a median of 4.0 mmHg following fenestration (p = 0.031), with significant reductions in Stanford type B dissections (p = 0.013) and minor reductions in type A dissections (p = 0.530). A moderate correlation with no statistical significance was found between dTTP and the difference in systolic blood pressure (r = 0.226; p = 0.351). CONCLUSIONS: Hemodynamic parameters obtained from color-coded DSA confirmed a significant reduction of TTP values in the aortic target lumen in terms of an improved perfusion in the compromised aortic region. Color-coded DSA might thus be a suitable complementary tool in the assessment of complex vascular patterns prevailing in aortic dissections, especially when blood pressure measurements are not conclusive or feasible.


Asunto(s)
Angiografía de Substracción Digital/métodos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Procedimientos Endovasculares , Procedimientos Endovasculares/métodos , Femenino , Fluoroscopía , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
BMC Musculoskelet Disord ; 23(1): 189, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35232415

RESUMEN

BACKGROUND: Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and Rüedi (ER) with regard to interobserver reliability and confidence in clinical practice. METHODS: Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers. RESULTS: In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95% confidence interval [CI] 0.676-0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95% CI 0.525-0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95% CI 0.771-0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95% CI 0.692-0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912). CONCLUSIONS: The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and Rüedi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.


Asunto(s)
Fracturas del Hombro , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Escápula/diagnóstico por imagen
13.
BMC Musculoskelet Disord ; 23(1): 284, 2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35331212

RESUMEN

BACKGROUND: In wrist arthrograms, aberrant contrast material is frequently seen extending into the soft tissue adjacent to the ulnar styloid process. Since the prestyloid recess can mimic contrast leakage in CT arthrography, this study aims to provide a detailed analysis of its morphologic variability, while investigating whether actual ulnar-sided leakage is associated with injuries of the triangular fibrocartilage complex (TFCC). METHODS: Eighty-six patients with positive wrist trauma history underwent multi-compartment CT arthrography (40 women, median age 44.5 years). Studies were reviewed by two board-certified radiologists, who documented the morphology of the prestyloid recess regarding size, opening type, shape and position, as well as the presence or absence of ulnar-sided contrast leakage. Correlations between leakage and the presence of TFCC injuries were assessed using the mean square contingency coefficient (rɸ). RESULTS: The most common configuration of the prestyloid recess included a narrow opening (73.26%; width 2.26 ± 1.43 mm), saccular shape (66.28%), and palmar position compared to the styloid process (55.81%). Its mean length and anterior-posterior diameter were 6.89 ± 2.36 and 5.05 ± 1.97 mm, respectively. Ulnar-sided contrast leakage was reported in 29 patients (33.72%) with a mean extent of 12.30 ± 5.31 mm. Leakage occurred more often in patients with ulnar-sided TFCC injuries (rɸ = 0.480; p < 0.001), whereas no association was found for lesions of the central articular disc (rɸ = 0.172; p = 0.111). CONCLUSIONS: Since ulnar-sided contrast leakage is more common in patients with peripheral TFCC injuries, distinction between an atypical configuration of the prestyloid recess and actual leakage is important in CT arthrography of the wrist.


Asunto(s)
Artrografía , Muñeca , Adulto , Femenino , Humanos , Tomografía Computarizada por Rayos X , Cúbito/diagnóstico por imagen , Cúbito/patología , Articulación de la Muñeca/diagnóstico por imagen
14.
Nervenarzt ; 93(8): 819-827, 2022 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-34734295

RESUMEN

Giant cell arteritis (GCA) is the most common idiopathic systemic vasculitis in the age group over 50 years. It requires prompt diagnostics and treatment to avoid severe complications, such as visual loss or stroke. The tendency to relapse makes a glucocorticoid (GC) treatment necessary for several years and sometimes lifelong, which increases the risk of GC-induced long-term side effects. Therefore, additive GC-sparing treatment is recommended in the majority of patients. For this purpose, the anti-IL­6 receptor antibody tocilizumab is available as an approved substance for subcutaneous application; alternatively, methotrexate (MTX) can be used (off-label).


Asunto(s)
Arteritis de Células Gigantes , Quimioterapia Combinada , Arteritis de Células Gigantes/diagnóstico , Arteritis de Células Gigantes/tratamiento farmacológico , Glucocorticoides/uso terapéutico , Humanos , Metotrexato/uso terapéutico , Persona de Mediana Edad , Recurrencia
15.
Eur Radiol ; 31(12): 9399-9407, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34003353

RESUMEN

OBJECTIVES: Triangular fibrocartilage complex (TFCC) injuries frequently cause ulnar-sided wrist pain and can induce distal radioulnar joint instability. With its complex three-dimensional structure, diagnosis of TFCC lesions remains a challenging task even in MR arthrograms. The aim of this study was to assess the added diagnostic value of radial reformatting of isotropic 3D MRI datasets compared to standard planes after direct arthrography of the wrist. METHODS: Ninety-three patients underwent wrist MRI after fluoroscopy-guided multi-compartment arthrography. Two radiologists collectively analyzed two datasets of each MR arthrogram for TFCC injuries, with one set containing standard reconstructions of a 3D thin-slice sequence in axial, coronal and sagittal orientation, while the other set comprised an additional radial plane view with the rotating center positioned at the ulnar styloid. Surgical reports (whenever available) or radiological reports combined with clinical follow-up served as a standard of reference. In addition, diagnostic confidence and assessability of the central disc and ulnar-sided insertions were subjectively evaluated. RESULTS: Injuries of the articular disc, styloid and foveal ulnar attachment were present in 20 (23.7%), 10 (10.8%) and 9 (9.7%) patients. Additional radial planes increased diagnostic accuracy for lesions of the styloid (0.83 vs. 0.90; p = 0.016) and foveal (0.86 vs. 0.94; p = 0.039) insertion, whereas no improvement was identified for alterations of the central cartilage disc. Readers' confidence (p < 0.001) and assessability of the ulnar-sided insertions (p < 0.001) were superior with ancillary radial reformatting. CONCLUSIONS: Access to the radial plane view of isotropic 3D sequences in MR arthrography improves diagnostic accuracy and confidence for ulnar-sided TFCC lesions. KEY POINTS: • In multi-compartment arthrography of the wrist, ancillary radial plane view aids assessability of the foveal and styloid ulnar-sided insertions of the triangular fibrocartilage complex. • Assessment of peripheral TFCC injuries is more accurate with access to radial multiplanar reconstructions. • Additional radial planes provide greater diagnostic confidence.


Asunto(s)
Fibrocartílago Triangular , Traumatismos de la Muñeca , Artrografía , Humanos , Imagen por Resonancia Magnética , Fibrocartílago Triangular/diagnóstico por imagen , Muñeca , Traumatismos de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/diagnóstico por imagen
16.
Eur Radiol ; 31(6): 3600-3609, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33280057

RESUMEN

OBJECTIVES: Trauma evaluation of extremities can be challenging in conventional radiography. A multi-use x-ray system with cone-beam CT (CBCT) option facilitates ancillary 3-D imaging without repositioning. We assessed the clinical value of CBCT scans by analyzing the influence of additional findings on therapy. METHODS: Ninety-two patients underwent radiography and subsequent CBCT imaging with the twin robotic scanner (76 wrist/hand/finger and 16 ankle/foot/toe trauma scans). Reports by on-call radiologists before and after CBCT were compared regarding fracture detection, joint affliction, comminuted injuries, and diagnostic confidence. An orthopedic surgeon recommended therapy based on reported findings. Surgical reports (N = 52) and clinical follow-up (N = 85) were used as reference standard. RESULTS: CBCT detected more fractures (83/64 of 85), joint involvements (69/53 of 71), and multi-fragment situations (68/50 of 70) than radiography (all p < 0.001). Six fractures suspected in radiographs were ruled out by CBCT. Treatment changes based on additional information from CBCT were recommended in 29 patients (31.5%). While agreement between advised therapy before CBCT and actual treatment was moderate (κ = 0.41 [95% confidence interval 0.35-0.47]; p < 0.001), agreement after CBCT was almost perfect (κ = 0.88 [0.83-0.93]; p < 0.001). Diagnostic confidence increased considerably for CBCT studies (p < 0.001). Median effective dose for CBCT was 4.3 µSv [3.3-5.3 µSv] compared to 0.2 µSv [0.1-0.2 µSv] for radiography. CONCLUSIONS: CBCT provides advantages for the evaluation of acute small bone and joint trauma by detecting and excluding extremity fractures and fracture-related findings more reliably than radiographs. Additional findings induced therapy change in one third of patients, suggesting substantial clinical impact. KEY POINTS: • With cone-beam CT, extremity fractures and fracture-related findings can be detected and ruled out more reliably than with conventional radiography. • Additional diagnostic information provided by cone-beam CT scans has substantial impact on therapy in small bone and joint trauma. • For distal extremity injury assessment, one-stop-shop imaging without repositioning is feasible with the twin robotic x-ray system.


Asunto(s)
Fracturas Óseas , Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada de Haz Cónico , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/terapia , Humanos , Radiografía , Rayos X
17.
BMC Med Imaging ; 21(1): 21, 2021 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-33568089

RESUMEN

BACKGROUND: Endovascular therapy is the gold standard in patients with hemodynamic relevant renal artery stenosis (RAS) resistant to medical therapy. The severity grading of the stenosis as well as the result assessment after endovascular approach is predominantly based on visible estimations of the anatomic appearance. We aim to investigate the application of color-coded DSA parameters to gain hemodynamic information during endovascular renal artery interventions and for the assessment of the procedures´ technical success. METHODS: We retrospectively evaluated 32 patients who underwent endovascular renal artery revascularization and applied color-coded summation imaging on selected monochromatic DSA images. The differences in time to peak (dTTP) of contrast enhancement in predefined anatomical measuring points were analyzed. Furthermore, differences in systolic blood pressure values (SBP) and serum creatinine were obtained. The value of underlying diabetes mellitus as a predictor for clinical outcome was assessed. Correlation analysis between the patients´ gender as well as the presence of diabetes mellitus and dTTP was performed. RESULTS: Endovascular revascularization resulted in statistically significant improvement in 4/7 regions of interest. Highly significant improvement of perfusion in terms of shortened TTP values could be found at the segmental artery level and in the intrastenotical segment (p < 0.001), significant improvement prestenotical and in the apical renal parenchyma (p < 0.05). In the other anatomic regions, differences revealed not to be significant. Differences between SBP and serum creatinine levels before and after the procedure were significant (p = 0.004 and 0.0004). Patients´ gender as well as the presence of diabetes mellitus did not reveal to be predictors for the clinical success of the procedure. Furthermore, diabetes and gender did not show relevant correlation with dTTP in the parenchymal measuring points. CONCLUSIONS: The supplementary use of color-coding DSA and the data gained from parametric images may provide helpful information in the evaluation of the procedures´ technical success. The segmental artery might be a particularly suitable vascular territory for analyzing differences in blood flow characteristics. Further studies with larger cohorts are needed to further confirm the diagnostic value of this technique.


Asunto(s)
Angiografía de Substracción Digital/métodos , Angioplastia , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Color , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Obstrucción de la Arteria Renal/fisiopatología , Estudios Retrospectivos , Adulto Joven
18.
Vasa ; 50(3): 193-201, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33140697

RESUMEN

Background: Arterioureteral fistulas (AUFs) are severe pathologies of different origin and with increasing incidence frequently appear in patients with underlying extensive malignancy and after pelvic surgery. AUF therapy is challenging since symptoms are frequently non-specific and patients are often unsuitable surgical candidates due to comorbidities. Since experiences with endovascular treatment strategies are limited, the feasibility, effectiveness, and safety were evaluated in a consecutive case series. Patients and methods: A retrospective analysis of five patients with endovascular AUF exclusion was performed. Probable predisposing factors for an AUF included history of pelvic malignancy with oncologic surgery in four patients, radiotherapy in four patients, and indwelling ureteral stents in four patients. Clinical presentation, diagnostic management, and site of fistula were assessed. Furthermore, technical and clinical success as well as complications were evaluated. Results: All patients presented with gross haematuria. In four patients, haematuria occurred during endoscopic ureteral stent manipulation. Affected vessels were the internal pudendal artery in one, intrarenal segmental artery and external iliac artery in two, and internal iliac artery in another two patients. Treatment included coil embolisation (n = 2), plug embolisation (n = 3), particulate embolisation (n = 1), and covered stent implantation (n = 2). Technical success was achieved in all procedures. In two cases, re-intervention was necessary due to AUF recurrence, resulting in a clinical success rate of 60.0%. One major complication class D was documented. Conclusions: AUFs can be treated effectively and safely using endovascular techniques. Diagnostic and therapeutic management of this rare entity requires a high level of awareness for potential risk factors as well as an optimal multidisciplinary coordination.


Asunto(s)
Procedimientos Endovasculares , Enfermedades Ureterales , Fístula Urinaria , Fístula Vascular , Procedimientos Endovasculares/efectos adversos , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Enfermedades Ureterales/diagnóstico por imagen , Enfermedades Ureterales/cirugía , Fístula Urinaria/diagnóstico por imagen , Fístula Urinaria/etiología , Fístula Urinaria/cirugía , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/cirugía
19.
Curr Rheumatol Rep ; 22(8): 34, 2020 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-32562073

RESUMEN

PURPOSE OF REVIEW: Vasculitides are characterized by mostly autoimmunologically induced inflammatory processes of vascular structures. They have various clinical and radiologic appearances. Early diagnosis and reliable monitoring are indispensable for adequate therapy to prevent potentially serious complications. Imaging, in addition to laboratory tests and physical examination, constitutes a key component in assessing disease extent and activity. This review presents current standards and some typical findings in the context of imaging in vasculitis with particular attention to large vessel vasculitides. RECENT FINDINGS: Recently, imaging has gained importance in the management of vasculitis, especially regarding large vessel vasculitides (LVV). Recently, EULAR (European League Against Rheumatism) has launched its recommendations concerning the diagnosis of LVVs. Imaging is recommended as the preferred complement to clinical examination. Color-coded duplex sonography is considered the first choice imaging test in suspected giant cell arteritis, and magnetic resonance imaging is considered the first choice in suspected Takayasu's arteritis. Due to diversity of clinical and radiologic presentations, diagnosis and therapy monitoring of vasculitides may constitute a challenge. As a result of ongoing technological progress, a variety of non-invasive imaging modalities now play an elemental role in the interdisciplinary management of vasculitic diseases.


Asunto(s)
Arteritis de Células Gigantes , Arteritis de Takayasu , Arteritis de Células Gigantes/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Arteritis de Takayasu/diagnóstico por imagen , Vasculitis/diagnóstico por imagen
20.
BMC Med Imaging ; 20(1): 67, 2020 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-32552680

RESUMEN

BACKGROUND: Percutaneous transluminal angioplasty (PTA) is increasingly requested in the therapy of peripheral arterial occlusive disease. The evaluation of the technical result after balloon angioplasty with regard to bailout stenting is highly dependent on the operators´ subjective assessment and mainly based on the monochromatic digital subtraction angiography (DSA) images. The aim of this study was to compare color-coded single image as a novel diagnostic tool with monochromatic DSA for the analysis of flow limitation and need for stent implantation after PTA of superficial femoral artery (SFA) stenoses. METHODS: During a period of 18 months, 213 SFA lesions were treated by PTA with a standard balloon in 170 patients, resulting in a total of 193 endovascular procedures. The median age of the patients was 77 years (range, 35-96 years). Median length of the treated lesions was 10.5 cm (range, 1.0-50 cm). Three interventional radiologists retrospectively evaluated the results of balloon angioplasty with monochromatic as well as post-processed color-coded DSA images for flow limitations to decide if subsequent stent implantation was necessary. Consensus reading of two experienced interventional radiologists 2 months after the initial review served as reference standard to perform a receiver operating characteristics (ROC) analysis. RESULTS: ROC analysis for readers A, B and C showed area under the curve (AUC) values of 0.797, 0.865 and 0.804 for color-coded DSA and AUC values of 0.792, 0.843 and 0.872 for monochromatic DSA: a significant advantage of color-coded over conventional monochromatic DSA was not found for readers A and B (p > 0.05). Results of reader C were significantly better in the assessment of monochromatic images (p = 0.023). Diagnostic confidence using color-coded images was slightly higher than in monochromatic images (κ = 0.486 vs. κ = 0.459). CONCLUSIONS: In this study, color coded DSA did not reveal to be superior to conventional monochromatic DSA when evaluating results of PTA and when deciding whether stent implantation is necessary or not. This technology, however, requires further experiences with special regard to homogeneously trained radiologists and to the time requirement.


Asunto(s)
Angiografía de Substracción Digital/métodos , Arteriopatías Oclusivas/terapia , Arteria Femoral/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia de Balón , Arteriopatías Oclusivas/diagnóstico por imagen , Color , Femenino , Arteria Femoral/cirugía , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA