1.
Otol Neurotol ; 43(1): e72-e78, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34739427

RESUMEN

OBJECTIVES: To compare intraoperative intracochlear electrocochleography (ECochG) with hearing preservation outcomes in cochlear implant (CI) subjects. DESIGN: Intraoperative electrocochleography was performed in adult CI subjects who were recipients of Advanced Bionics' Bionics LLC precurved HiFocus MidScala or straight HiFocus SlimJ electrode arrays. ECochG responses were recorded from the most apical electrode contact during insertion. No changes to the insertions were made due to ECochG monitoring. No information about insertion resistance was collected. ECochG drops were estimated as the change in amplitude from peak (defined as maximum amplitude response) to drop (largest drop) point after the peak during insertion was measured following the peak response. Audiometric thresholds from each subject were obtained before and approximately 1 month after CI surgery. The change in pure tone average for frequencies between 125 Hz and 500 Hz was measured after surgery. No postoperative CT scans were collected as part of this study. RESULTS: A total of 68 subjects from five surgical centers participated in the study. The study sample included 30 MidScala and 38 SlimJ electrodes implanted by approximately 20 surgeons who contributed to the study. Although a wide range of results were observed, there was a moderate positive correlation (Pearson Correlation coefficient, r = 0.56, p < 0.01) between the size of the ECochG drop and the magnitude of pure tone average change. This trend was present for both the MidScala and SlimJ arrays. The SlimJ and MidScala arrays produced significantly different hearing loss after surgery. CONCLUSION: Large ECochG amplitude drops observed during electrode insertion indicated poorer hearing preservation. Although the outcomes were variable, this information may be helpful to guide surgical decision-making when contemplating full electrode insertion and the likelihood of hearing preservation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Adulto , Audiometría de Respuesta Evocada/métodos , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Implantación Coclear/métodos , Audición , Humanos
2.
Otol Neurotol ; 39(8): e654-e659, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30113557

RESUMEN

HYPOTHESIS: Electrocochleography (ECochG) patterns observed during cochlear implant (CI) electrode insertion may provide information about scalar location of the electrode array. BACKGROUND: Conventional CI surgery is performed without actively monitoring auditory function and potential damage to intracochlear structures. The central hypothesis of this study was that ECochG obtained directly through the CI may be used to estimate intracochlear electrode position and, ultimately, residual hearing preservation. METHODS: Intracochlear ECochG was performed on 32 patients across 3 different implant centers. During electrode insertion, a 50-ms tone burst stimulus (500 Hz) was delivered at 110 dB SPL. The ECochG response was monitored from the apical-most electrode. The amplitude and phase changes of the first harmonic were imported into an algorithm in an attempt to predict the intracochlear electrode location (scala tympani [ST], translocation from ST to scala vestibuli [SV], or interaction with basilar membrane). Anatomic electrode position was verified using postoperative computed tomography (CT) with image processing. RESULTS: CT analysis confirmed 25 electrodes with ST position and 7 electrode arrays translocating from ST into SV. The ECochG algorithm correctly estimated electrode position in 26 (82%) of 32 subjects while 6 (18%) electrodes were wrongly identified as translocated (sensitivity = 100%, specificity = 77%, positive predictive value = 54%, and a negative predictive value = 100%). Greater hearing loss was observed postoperatively in participants with translocated electrode arrays (36 ±â€Š15 dB) when compared with isolated ST insertions (28 ±â€Š20 dB HL). This result, however, was not significant (p = 0.789). CONCLUSION: Intracochlear ECochG may provide information about CI electrode location and hearing preservation.


Asunto(s)
Audiometría de Respuesta Evocada/métodos , Implantación Coclear/métodos , Monitorización Neurofisiológica Intraoperatoria/métodos , Adulto , Cóclea/cirugía , Implantes Cocleares , Femenino , Humanos , Masculino