RESUMEN
OBJECTIVE: To investigate the association of estimated all-day and evening whole-brain radiofrequency electromagnetic field (RF-EMF) doses with sleep disturbances and objective sleep measures in preadolescents. METHODS: We included preadolescents aged 9-12 years from two population-based birth cohorts, the Dutch Generation R Study (n = 974) and the Spanish INfancia y Medio Ambiente Project (n = 868). All-day and evening overall whole-brain RF-EMF doses (mJ/kg/day) were estimated for several RF-EMF sources including mobile and Digital Enhanced Cordless Telecommunications (DECT) phone calls (named phone calls), other mobile phone uses, tablet use, laptop use (named screen activities), and far-field sources. We also estimated all-day and evening whole-brain RF-EMF doses in these three groups separately (i.e. phone calls, screen activities, and far-field). The Sleep Disturbance Scale for Children was completed by mothers to assess sleep disturbances. Wrist accelerometers together with sleep diaries were used to measure sleep characteristics objectively for 7 consecutive days. RESULTS: All-day whole-brain RF-EMF doses were not associated with self-reported sleep disturbances and objective sleep measures. Regarding evening doses, preadolescents with high evening whole-brain RF-EMF dose from phone calls had a shorter total sleep time compared to preadolescents with zero evening whole-brain RF-EMF dose from phone calls [-11.9 min (95%CI -21.2; -2.5)]. CONCLUSIONS: Our findings suggest the evening as a potentially relevant window of RF-EMF exposure for sleep. However, we cannot exclude that observed associations are due to the activities or reasons motivating the phone calls rather than the RF-EMF exposure itself or due to chance finding.
Asunto(s)
Teléfono Celular , Campos Electromagnéticos , Encéfalo , Niño , Campos Electromagnéticos/efectos adversos , Exposición a Riesgos Ambientales , Humanos , Ondas de Radio/efectos adversos , SueñoRESUMEN
PURPOSE: Healthy tissue hotspots are a main limiting factor in administering deep hyperthermia cancer therapy. We propose an optimization scheme that uses time-multiplexed steering (TMPS) among minimally correlated (nearly) Pareto-optimal solutions to suppress hotspots without reducing tumor heating. Furthermore, tumor heating homogeneity is maximized, thus reducing toxicity and avoiding underexposed tumor regions, which in turn may reduce recurrence. MATERIALS AND METHODS: The novel optimization scheme combines random generation of steering parameters with local optimization to efficiently identify the set of (Pareto-) optimal solutions of conflicting optimization goals. To achieve simultaneous suppression of hotspots, multiple steering parameter configurations with minimally correlated hotspots are selected near the Pareto front and combined in TMPS. The performance of the novel scheme was compared with that of a multi-goal Genetic Algorithm for a range of simulated treatment configurations involving a modular applicator heating a generic tumor situated in the bladder, cervix, or pelvic bone. SAR cumulative histograms in tumor and healthy tissue, as well as hotspot volumes are used as metrics. RESULTS: Compared to the non-TMPS optimization, the proposed scheme was able to reduce the peak temperature in healthy tissue by 0.2 °C-1.0 °C (a thermal dose reduction by at least 26%) and, importantly, the hotspot volume above 42 °C in healthy tissue by 41%-86%. At the same time, tumor heating homogeneity was maintained or improved. CONCLUSIONS: The extremely rapid optimization (5 s for TMPS part, on a standard PC) permits closed-loop treatment reoptimization during treatment administration, and empowers physicians with a selection of optimal treatment scenarios reflecting different weighting of conflicting treatment goals.
Asunto(s)
Objetivos , Hipertermia Inducida , Femenino , Calefacción , Humanos , HipertermiaRESUMEN
BACKGROUND: Little is known about radiofrequency electromagnetic fields (RF) from mobile technology and resulting dose in young people. We describe modeled integrated RF dose in European children and adolescents combining own mobile device use and surrounding sources. METHODS: Using an integrated RF model, we estimated the daily RF dose in the brain (whole-brain, cerebellum, frontal lobe, midbrain, occipital lobe, parietal lobe, temporal lobes) and the whole-body in 8358 children (ages 8-12) and adolescents (ages 14-18) from the Netherlands, Spain, and Switzerland during 2012-2016. The integrated model estimated RF dose from near-field sources (digital enhanced communication technology (DECT) phone, mobile phone, tablet, and laptop) and far-field sources (mobile phone base stations via 3D-radiowave modeling or RF measurements). RESULTS: Adolescents were more frequent mobile phone users and experienced higher modeled RF doses in the whole-brain (median 330.4 mJ/kg/day) compared to children (median 81.8 mJ/kg/day). Children spent more time using tablets or laptops compared to adolescents, resulting in higher RF doses in the whole-body (median whole-body dose of 81.8 mJ/kg/day) compared to adolescents (41.9 mJ/kg/day). Among brain regions, temporal lobes received the highest RF dose (medians of 274.9 and 1786.5 mJ/kg/day in children and adolescents, respectively) followed by the frontal lobe. In most children and adolescents, calling on 2G networks was the main contributor to RF dose in the whole-brain (medians of 31.1 and 273.7 mJ/kg/day, respectively). CONCLUSION: This first large study of RF dose to the brain and body of children and adolescents shows that mobile phone calls on 2G networks are the main determinants of brain dose, especially in temporal and frontal lobes, whereas whole-body doses were mostly determined by tablet and laptop use. The modeling of RF doses provides valuable input to epidemiological research and to potential risk management regarding RF exposure in young people.
Asunto(s)
Teléfono Celular , Campos Electromagnéticos , Adolescente , Encéfalo , Niño , Comunicación , Exposición a Riesgos Ambientales , Humanos , Países Bajos , Ondas de Radio , España , SuizaRESUMEN
PURPOSE: Cardiovascular magnetic resonance first-pass perfusion for the pixel-wise detection of coronary artery disease is rapidly becoming the clinical standard, yet no widely available method exists for its assessment and validation. This study introduces a novel phantom capable of generating spatially dependent flow values to enable assessment of new perfusion imaging methods at the pixel level. METHODS: A synthetic multicapillary myocardial phantom mimicking transmural myocardial perfusion gradients was designed and manufactured with high-precision 3D printing. The phantom was used in a stationary flow setup providing reference myocardial perfusion rates and was scanned on a 3T system. Repeated first-pass perfusion MRI for physiological perfusion rates between 1 and 4 mL/g/min was performed using a clinical dual-sequence technique. Fermi function-constrained deconvolution was used to estimate pixel-wise perfusion rate maps. Phase contrast (PC)-MRI was used to obtain velocity measurements that were converted to perfusion rates for validation of reference values and cross-method comparison. The accuracy of pixel-wise maps was assessed against simulated reference maps. RESULTS: PC-MRI indicated excellent reproducibility in perfusion rate (coefficient of variation [CoV] 2.4-3.5%) and correlation with reference values (R2 = 0.985) across the full physiological range. Similar results were found for first-pass perfusion MRI (CoV 3.7-6.2%, R2 = 0.987). Pixel-wise maps indicated a transmural perfusion difference of 28.8-33.7% for PC-MRI and 23.8-37.7% for first-pass perfusion, matching the reference values (30.2-31.4%). CONCLUSION: The unique transmural perfusion pattern in the phantom allows effective pixel-wise assessment of first-pass perfusion acquisition protocols and quantification algorithms before their introduction into routine clinical use.
Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Diseño de Equipo , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Impresión Tridimensional , Reproducibilidad de los ResultadosRESUMEN
Exposure to extremely low-frequency magnetic fields (ELF-MFs) has been classified by the International Agency for Research on Cancer (IARC) as "possibly carcinogenic to humans," based on limited scientific evidence concerning childhood leukemia. This assessment emphasized the lack of appropriate animal models recapitulating the natural history of this disease. Childhood B-cell acute lymphoblastic leukemia (B-ALL) is the result of complex interactions between genetic susceptibility and exposure to exogenous agents. The most common chromosomal alteration is the ETV6-RUNX1 fusion gene, which confers a low risk of developing the malignancy by originating a preleukemic clone requiring secondary hits for full-blown disease to appear. To develop potential prophylactic interventions, we need to identify the environmental triggers of the second hit. Recently, we generated a B-ALL mouse model of the human ETV6-RUNX1+ preleukemic state. Here, we present the results from the ARIMMORA pilot study, obtained by exposing 34 Sca1-ETV6-RUNX1 mice (vs. 27 unexposed) to a 50 Hz magnetic field of 1.5 mT with both fundamental and harmonic content, with an on/off cycle of 10 min/5 min, for 20 h/day, from conception until 3 months of age. Mice were monitored until 2 years of age and peripheral blood was periodically analyzed by flow cytometry. One of the exposed mice developed B-ALL while none of the non-exposed did. Although the results are statistically non-significant due to the limited number of mice used in this pilot experiment, overall, the results show that the newly developed Sca1-ETV6-RUNX1 mouse can be successfully used for ELF-MF exposure studies about the etiology of childhood B-ALL. Bioelectromagnetics. 2019;40:343-353. © 2019 Bioelectromagnetics Society.
Asunto(s)
Subunidad alfa 2 del Factor de Unión al Sitio Principal/genética , Modelos Animales de Enfermedad , Campos Electromagnéticos/efectos adversos , Leucemia Experimental , Leucemia-Linfoma Linfoblástico de Células Precursoras , Proteínas Proto-Oncogénicas c-ets/genética , Ondas de Radio/efectos adversos , Proteínas Represoras/genética , Animales , Subunidad alfa 2 del Factor de Unión al Sitio Principal/metabolismo , Femenino , Humanos , Leucemia Experimental/genética , Leucemia Experimental/metabolismo , Masculino , Ratones , Ratones Endogámicos C57BL , Proyectos Piloto , Leucemia-Linfoma Linfoblástico de Células Precursoras/etiología , Leucemia-Linfoma Linfoblástico de Células Precursoras/genética , Leucemia-Linfoma Linfoblástico de Células Precursoras/metabolismo , Proteínas Proto-Oncogénicas c-ets/metabolismo , Proteínas Represoras/metabolismo , Proteína ETS de Variante de Translocación 6RESUMEN
Electromagnetic fields are ubiquitous in the environment. Human exposure to intermediate frequency (IF) fields is increasing due to applications like electronic article surveillance systems, wireless power transfer, and induction heating cooking hobs. However, there are limited data on possible health effects of exposure to IF magnetic fields (MF). In the present study, we set out to assess cognitive and behavioural effects of IF MF in mice exposed during prenatal and early postnatal periods. Pregnant female mice were exposed continuously to 7.5kHz MFs at 12 and 120µT, from mating until weaning of pups. Sham exposed pregnant mice were used as a control group. A behavioural teratology study was conducted on the male offspring at two months of age to detect possible effects on the developing nervous system. Body weight development did not differ between the exposure groups. The exposure did not alter spontaneous motor activity when exploring a novel cage or anxiety in novelty-suppressed feeding or marble burying tests. Improved performance in the Rotarod task was observed in the 12µT group, while the 120µT exposure group swam more slowly than the sham exposed group in the Morris swim navigation task. However, indices of learning and memory (path length and escape latency during task acquisition and search bias during the probe test) did not differ between the exposure groups. Furthermore, the passive avoidance task did not indicate any impairment of long-term memory over a 48h interval in the exposed groups. In a post-mortem histopathological analysis, there was no evidence for an effect of IF MF exposure on astroglial reactivity or hippocampal neurogenesis. The results suggest that the IF MF used did not have detrimental effects on spatial learning and memory or histological markers of tissue reaction. The two statistically significant findings that were observed (improved performance in the Rotarod task in the 12µT group and decreased swimming speed in the 120µT group) are likely to be chance findings, as they do not form an internally consistent, dose-dependent pattern indicative of specific developmental effects.
Asunto(s)
Conducta Animal , Campos Magnéticos , Memoria , Fenotipo , Efectos Tardíos de la Exposición Prenatal , Animales , Campos Electromagnéticos , Conducta Exploratoria , Femenino , Aprendizaje , Campos Magnéticos/efectos adversos , Masculino , Ratones , Embarazo , ReproducciónRESUMEN
Radiofrequency radiation (RFR) causes heating, which can lead to detrimental biological effects. To characterize the effects of RFR exposure on body temperature in relation to animal size and pregnancy, a series of short-term toxicity studies was conducted in a unique RFR exposure system. Young and old B6C3F1 mice and young, old, and pregnant Harlan Sprague-Dawley rats were exposed to Global System for Mobile Communication (GSM) or Code Division Multiple Access (CDMA) RFR (rats = 900 MHz, mice = 1,900 MHz) at specific absorption rates (SARs) up to 12 W/kg for approximately 9 h a day for 5 days. In general, fewer and less severe increases in body temperature were observed in young than in older rats. SAR-dependent increases in subcutaneous body temperatures were observed at exposures ≥6 W/kg in both modulations. Exposures of ≥10 W/kg GSM or CDMA RFR induced excessive increases in body temperature, leading to mortality. There was also a significant increase in the number of resorptions in pregnant rats at 12 W/kg GSM RFR. In mice, only sporadic increases in body temperature were observed regardless of sex or age when exposed to GSM or CDMA RFR up to 12 W/kg. These results identified SARs at which measurable RFR-mediated thermal effects occur, and were used in the selection of exposures for subsequent toxicology and carcinogenicity studies. Bioelectromagnetics. 39:190-199, 2018. © 2018 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.
Asunto(s)
Temperatura Corporal/efectos de la radiación , Teléfono Celular , Exposición a la Radiación/efectos adversos , Ondas de Radio/efectos adversos , Envejecimiento/fisiología , Animales , Femenino , Ratones , Proyectos Piloto , Embarazo , Ratas , Ratas Sprague-DawleyRESUMEN
In this paper we present the novel design features, their technical implementation, and an evaluation of the radio Frequency (RF) exposure systems developed for the National Toxicology Program (NTP) of the National Institute of Environmental Health Sciences (NIEHS) studies on the potential toxicity and carcinogenicity of 2nd and 3rd generation mobile-phone signals. The system requirements for this 2-year NTP cancer bioassay study were the tightly-controlled lifetime exposure of rodents (1568 rats and 1512 mice) to three power levels plus sham simulating typical daily, and higher, exposures of users of GSM and CDMA (IS95) signals. Reverberation chambers and animal housing were designed to allow extended exposure time per day for free-roaming individually-housed animals. The performance of the chamber was characterized in terms of homogeneity, stirred to unstirred energy, efficiency. The achieved homogeneity was 0.59 dB and 0.48 dB at 900 and 1900 MHz respectively. The temporal variation in the electric field strength was optimized to give similar characteristics to that of the power control of a phone in a real network using the two stirrers. Experimental dosimetry was performed to validate the SAR sensitivity and determine the SAR uniformity throughout the exposure volume; SAR uniformities of 0.46 dB and 0.40 dB, respectively, for rats and mice were achieved.
RESUMEN
In this paper, we present the detailed life-time dosimetry analysis for rodents exposed in the reverberation exposure system designed for the two-year cancer bioassay study conducted by the National Toxicology Program of the National Institute of Environmental Health Sciences. The study required the well-controlled and characterized exposure of individually housed, unrestrained mice at 1900 MHz and rats at 900 MHz, frequencies chosen to give best uniformity exposure of organs and tissues. The wbSAR, the peak spatial SAR and the organ specific SAR as well as the uncertainty and variation due to the exposure environment, differences in the growth rates, and animal posture were assessed. Compared to the wbSAR, the average exposure of the high-water-content tissues (blood, heart, lung) were higher by ~4 dB, while the low-loss tissues (bone and fat) were less by ~9 dB. The maximum uncertainty over the exposure period for the SAR was estimated to be <49% (k=2) for the rodents whereas the relative uncertainty between the group was <14% (k=1). The instantaneous variation (averaged over 1 min) was <13% (k=1), which is small compared to other long term exposure research projects. These detailed dosimetric results empowers comparison with other studies and provides a reference for studies of long-term biological effects of exposure of rodents to RF energy.
RESUMEN
An exposure system that addresses difficulties that arise for exposure of small animals at low frequencies with a high exposure level is presented. The system, intended to operate at 27 MHz, consists of two identical transverse electro-magnetic (TEM) cells for exposure and sham exposure of groups of 16 free-running mice housed in pairs within standard cages, capable of exposure over extended daily periods while being provided food and water. Inclusion of the exposure cell in a half-wavelength resonator has been developed as a new paradigm to enhance field strength for an increase of >50-fold in available specific absorption rate (SAR) levels compared to traditional TEM cell configurations. The system described allows both daily and weekly exposure schedules and supports blinded protocols with continuous wave (CW) and amplitude modulation (AM) signals with programmable modulation depths and frequencies. Electric field (E-field) homogeneity across the TEM cell along a vertical plane (orthogonal to the axis of the TEM line) was within 3.3%, and 3.1% along the horizontal plane. Accurate and comprehensive dosimetric assessments based on whole-body and organ-specific SAR essential for in vivo bioelectromagnetic experiments are presented, which takes into account various factors (e.g., mouse activities, close proximity, and field homogeneity). Average SAR levels are controllable in the range of 1 mW/kg to 2 W/kg, with expanded uncertainty (k = 2) of 1 dB and instantaneous variation (k = 1) of 4 dB.
Asunto(s)
Campos Electromagnéticos , Exposición a la Radiación/análisis , Monitoreo de Radiación/instrumentación , Absorción de Radiación , Animales , Campos Electromagnéticos/efectos adversos , Ratones , Especificidad de Órganos , Incertidumbre , Irradiación Corporal Total/efectos adversosRESUMEN
This paper describes a new approach to the risk assessment of exposure from wireless network devices, including an exposure setup and dosimetric assessment for in vivo studies. A novel desktop reverberation chamber has been developed for well-controlled exposure of mice for up to 24 h per day to address the biological impact of human exposure scenarios by wireless networks. The carrier frequency of 2.45 GHz corresponds to one of the major bands used in data communication networks and is modulated by various modulation schemes, including Global System for Mobile Communications (GSM), Universal Mobile Telecommunications System (UMTS), Radio Frequency Identification (RFID), and wireless local area network, etc. The system has been designed to enable exposures of whole-body averaged specific absorption rate (SAR) of up to 15 W/kg for six mice of an average weight of 25 g or of up to 320 V/m incident time-averaged fields under loaded conditions without distortion of the signal. The dosimetry for whole-body SAR and organ-averaged SAR of the exposed mice, with analysis of uncertainty and variation analysis, is assessed. The experimental dosimetry based on temperature measurement agrees well with the numerical dosimetry, with a very good SAR uniformity of 0.4 dB in the chamber. Furthermore, a thermal analysis and measurements were performed to provide better understanding of the temperature load and distribution in the mice during exposure.
Asunto(s)
Ondas de Radio , Radiometría/instrumentación , Tecnología Inalámbrica/instrumentación , Animales , Redes de Comunicación de Computadores/instrumentación , Relación Dosis-Respuesta en la Radiación , Humanos , Ratones , Modelos Anatómicos , Proyectos Piloto , Ondas de Radio/efectos adversos , Ratas , TemperaturaRESUMEN
We describe a method to correlate E-fields induced by exposure to extremely low frequency magnetic fields in laboratory mice and rats during in vivo experiments to those induced in children. Four different approaches of mapping relative dose rates between humans and rodents are herein proposed and analyzed. Based on these mapping methods and volume averaging guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNRP) in 2010, maximum and median induced field values for whole body and for tissues of children and rodents were evaluated and compared. Median induced electric fields in children younger than 10 years old are in the range 5.9-8.5 V/m per T (±0.4 dB). Maximum induced electric fields, generally in the skin, are between 48 V/m and 228 V/m per T (±4 dB). To achieve induced electric fields of comparable magnitude in rodents, external magnetic field must be increased by a factor of 4.0 (±2.6 dB) for rats and 7.4 (±1.8 dB) for mice. Meanwhile, to achieve comparable magnetic field dose in rodents, ratio is close to one. These induced field dose rates for children and rodents can be used to quantifiably compare experimental data from in vivo studies with data on exposure of children from epidemiological studies, such as for leukemia. Bioelectromagnetics. 37:310-322, 2016. © 2016 Wiley Periodicals, Inc.
Asunto(s)
Campos Magnéticos , Radiometría/métodos , Animales , Niño , Preescolar , Simulación por Computador , Femenino , Humanos , Lactante , Masculino , Ratones , Ratas , Especificidad de la Especie , IncertidumbreRESUMEN
Exposure to extremely low-frequency magnetic fields (ELF-MF) was evaluated in an International Agency for Research on Cancer (IARC) Monographs as "possibly carcinogenic to humans" in 2001, based on increased childhood leukemia risk observed in epidemiological studies. We conducted a hazard assessment using available scientific evidence published before March 2015, with inclusion of new research findings from the Advanced Research on Interaction Mechanisms of electroMagnetic exposures with Organisms for Risk Assessment (ARIMMORA) project. The IARC Monograph evaluation scheme was applied to hazard identification. In ARIMMORA for the first time, a transgenic mouse model was used to mimic the most common childhood leukemia: new pathogenic mechanisms were indicated, but more data are needed to draw definitive conclusions. Although experiments in different animal strains showed exposure-related decreases of CD8+ T-cells, a role in carcinogenesis must be further established. No direct damage of DNA by exposure was observed. Overall in the literature, there is limited evidence of carcinogenicity in humans and inadequate evidence of carcinogenicity in experimental animals, with only weak supporting evidence from mechanistic studies. New exposure data from ARIMMORA confirmed that if the association is nevertheless causal, up to 2% of childhood leukemias in Europe, as previously estimated, may be attributable to ELF-MF. In summary, ARIMMORA concludes that the relationship between ELF-MF and childhood leukemia remains consistent with possible carcinogenicity in humans. While this scientific uncertainty is dissatisfactory for science and public health, new mechanistic insight from ARIMMORA experiments points to future research that could provide a step-change in future assessments. Bioelectromagnetics. 37:183-189, 2016. © 2016 Wiley Periodicals, Inc.
RESUMEN
PURPOSE: This article investigates the safety of radiofrequency induced local thermal hotspots within a 1.5T body coil by assessing the transient local peak temperatures as a function of exposure level and local thermoregulation in four anatomical human models in different Z-positions. METHODS: To quantize the effective thermal stress of the tissues, the thermal dose model cumulative equivalent minutes at 43°C was employed, allowing the prediction of thermal tissue damage risk and the identification of potentially hazardous MR scan-scenarios. The numerical results were validated by B1 (+) - and skin temperature measurements. RESULTS: At continuous 4 W/kg whole-body exposure, peak tissue temperatures of up to 42.8°C were computed for the thermoregulated model (60°C in nonregulated case). When applying cumulative equivalent minutes at 43°C damage thresholds of 15 min (muscle, skin, fat, and bone) and 2 min (other), possible tissue damage cannot be excluded after 25 min for the thermoregulated model (4 min in nonregulated). CONCLUSION: The results are found to be consistent with the history of safe use in MR scanning, but not with current safety guidelines. For future safety concepts, we suggest to use thermal dose models instead of temperatures or SAR. Special safety concerns for patients with impaired thermoregulation (e.g., the elderly, diabetics) should be addressed.
Asunto(s)
Regulación de la Temperatura Corporal/efectos de la radiación , Quemaduras por Electricidad/etiología , Quemaduras por Electricidad/fisiopatología , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/instrumentación , Irradiación Corporal Total/efectos adversos , Irradiación Corporal Total/instrumentación , Carga Corporal (Radioterapia) , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Imagen por Resonancia Magnética/normas , Modelos Biológicos , Dosis de Radiación , Radiometría/métodos , Valores de Referencia , SuizaRESUMEN
BACKGROUND: The influence of electromagnetic fields on the health of humans and animals is still an intensively discussed and scientifically investigated issue (Prakt Tierarzt 11:15-20, 2003; Umwelt Medizin Gesellschaft 17:326-332, 2004; J Toxicol Environment Health, Part B 12:572-597, 2009). We are surrounded by numerous electromagnetic fields of variable strength, coming from electronic equipment and its power cords, from high-voltage power lines and from antennas for radio, television and mobile communication. Particularly the latter cause's controversy, as everyone likes to have good mobile reception at anytime and anywhere, whereas nobody wants to have such a basestation antenna in their proximity. RESULTS: In this experiment, the NIR has resulted in changes in the enzyme activities. Certain enzymes were disabled, others enabled by NIR. Furthermore, individual behavior patterns were observed. While certain cows reacted to NIR, others did not react at all, or even inversely. CONCLUSION: The present results coincide with the information from the literature, according to which NIR leads to changes in redox proteins, and that there are individuals who are sensitive to radiation and others that are not. However, the latter could not be distinctly attributed - there are cows that react clearly with one enzyme while they do not react with another enzyme at all, or even the inverse. The study approach of testing ten cows each ten times during three phases has proven to be appropriate. Future studies should however set the post-exposure phase later on.
Asunto(s)
Catalasa/metabolismo , Bovinos/sangre , Regulación Enzimológica de la Expresión Génica/efectos de la radiación , Glutatión Peroxidasa/metabolismo , Radiación no Ionizante , Superóxido Dismutasa/metabolismo , Animales , Catalasa/sangre , Glutatión Peroxidasa/sangre , Superóxido Dismutasa/sangreRESUMEN
In this paper, fetal exposure to uniform magnetic fields (MF) with different polarizations is quantified at 50 Hz. Numerical computations were performed on high-resolution pregnant models at 3, 7, and 9 months of gestational age (GA), that distinguish a high number of fetal tissues. Fetal whole-body and tissue-specific induced electric fields (E) and current densities (J) were analyzed as a function of both the extremely low frequency magnetic field (ELF-MF) polarization and GA. Additionally, the induced field variation due to changes in fetal position was analyzed by means of two new pregnant models. The uncertainty budget due to the grid resolution was also calculated. Finally, the compliance of the fetal exposure to the ICNIRP Guidelines was checked. A fetal exposure matrix was built at 50 Hz, which could be used to further investigate possible interaction mechanisms between ELF-MF and the associated health risk. Some specific findings were: (1) the induced fields increased with GA; (2) the maxima E were found in skin and fat tissues at each GA; (3) fetal tissue-specific exposure was modified as a function of GA and polarization; (4) the change of the fetal position in the womb significantly modified the induced E in some fetal tissues; (5) the induced fields were in compliance with ICNIRP Guidelines and the results were quite below the permitted threshold limit.
Asunto(s)
Feto , Campos Magnéticos/efectos adversos , Exposición Materna/efectos adversos , Incertidumbre , Adulto , Huesos , Femenino , Feto/anatomía & histología , Feto/fisiología , Humanos , Modelos Anatómicos , Especificidad de Órganos , Postura , EmbarazoRESUMEN
A programmable system has been developed for the study of both transient and persistent effects of extremely low frequency (ELF) magnetic field exposure of cell cultures. This high-precision exposure system enables experimental blinding and fully characterized exposure while simultaneously allowing live cell imaging. It is based on a live imaging cell around which two asymmetrical coils are wound in good thermal contact to a temperature-controlled water jacket, and is mounted on a microscope stage insert. The applied B-field uniformity of the active volume is better than 1.2% with an overall exposure uncertainty of less than 4.3% with very low transient field levels. The computer-controlled apparatus allows signal waveforms that are sinusoidal or composed of several harmonics, blind protocols, and monitoring of exposure and environmental conditions. B-fields up to 4 mT root mean square amplitude are possible with minimal temperature variation and no recognizable temperature differences between exposure and sham states. Sources of artifacts have been identified and quantified. There are no visible vibrations observable even at the highest magnifications and exposure levels.
Asunto(s)
Células Cultivadas , Campos Electromagnéticos , Artefactos , Técnicas de Cultivo de Célula , Diseño de Equipo , Microscopía/métodos , Distribución AleatoriaRESUMEN
OBJECTIVE: The clinical management of several neurological disorders benefits from the assessment of intracranial pressure and craniospinal compliance. However, the associated procedures are invasive in nature. Here, we aimed to assess whether naturally occurring periodic changes in the dielectric properties of the head could serve as the basis for deriving surrogates of craniospinal compliance noninvasively. METHODS: We designed a device and electrodes for noninvasive measurement of periodic changes of the dielectric properties of the human head. We characterized the properties of the device-electrode-head system by measurements on healthy volunteers, by computational modeling, and by electromechanical modeling. We then performed hyperventilation testing to assess whether the measured signal is of intracranial origin. RESULTS: Signals obtained with the device on volunteers showed characteristic cardiac and respiratory modulations. Signal oscillations can be attributed primarily to changes in resistive properties of the head during cardiac and respiratory cycles. Reduction of end-tidal CO2, through hyperventilation, resulted in a decrease in the signal amplitude associated with cardiovascular action. CONCLUSION: Given the higher CO2 reactivity of intracranial vessels compared to extracranial ones, the results of hyperventilation testing suggest that the acquired signal is, in part, of intracranial origin. SIGNIFICANCE: If confirmed in larger cohorts, our observations suggest that noninvasive capacitive acquisition of changes in the dielectric properties of the head could be used to derive surrogates of craniospinal compliance.
Asunto(s)
Dióxido de Carbono , Hiperventilación , Humanos , Presión Intracraneal , Cabeza , Frecuencia CardíacaRESUMEN
The development of scientifically sound instrumentation, methods, and procedures for the electromagnetic exposure assessment of compact fluorescent lamps (CFLs) is investigated. The incident and induced fields from 11 CFLs have been measured in the 10 kHz-1 MHz range, and they are compared with the levels for incandescent and light emitting diode (LED) bulbs. Commercially available equipment was used to measure the incident fields, while a novel sensor was built to assess the induced fields in humans. Incident electric field levels significantly exceed the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference levels at close distances for some sources, while the induced fields are within the ICNIRP basic restrictions. This demonstrates the importance of assessing the induced fields rather than the incident fields for these sources. Maximum current densities for CFLs are comparable to the limits (in the range of 9% to 56%), demonstrating the need for measurements to establish compliance. For the frequency range investigated, the induced fields were found to be considerably higher for CFLs than for incandescent light bulbs, while the exposure from the two LED bulbs was low. The proposed instrumentation and methods offer several advantages over an existing measurement standard, and the measurement uncertainty is significantly better than the assessment of electric and magnetic fields at close distances.
Asunto(s)
Campos Electromagnéticos , Exposición a Riesgos Ambientales/análisis , Iluminación/instrumentación , Magnetismo/instrumentación , Monitoreo de Radiación/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
BACKGROUND AND OBJECTIVE: Hyperthermia is a cancer treatment aiming to induce cell death by directly warming cancerous tissues above 40 °C. This technique can be applied both individually and together with other cancer therapies. The main challenge for researchers and medics is to heat only tumoral cells avoiding global or localized heating of sane tissues. The objective in this study is to provide a realistic virtual scenario to develop an optimized multi-site injection plan for tailored magnetic nanoparticle-mediated hyperthermia applications. METHODS: A three-dimensional model of a cat's back was tested in three different simulation scenarios, showing the impact of magnetic nanoparticles in each specific environment configuration. RESULTS: As a result of this study. This simulation method can, minimising the affection to healthy tissue. CONCLUSIONS: This virtual method will help real and personalized therapy planning and tailor the dose and distribution of magnetic nanoparticles for an enhanced hyperthermia cancer treatment.