Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 561
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Lancet ; 401(10378): 773-788, 2023 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-36640801

RESUMEN

Although substantial progress has been made in the prevention, diagnosis, and treatment of acute aortic dissection, it remains a complex cardiovascular event, with a high immediate mortality and substantial morbidity in individuals surviving the acute period. The past decade has allowed a leap forward in understanding the pathophysiology of this disease; the existing classifications have been challenged, and the scientific community moves towards a nomenclature that is likely to unify the current definitions according to morphology and function. The most important pathophysiological pathway, namely the location and extension of the initial intimal tear, which causes a disruption of the media layer of the aortic wall, together with the size of the affected aortic segments, determines whether the patient should undergo emergency surgery, an endovascular intervention, or receive optimal medical treatment. The scientific evidence for the management and follow-up of acute aortic dissection continues to evolve. This Seminar provides a clinically relevant overview of potential prevention, diagnosis, and management of acute aortic dissection, which is the most severe acute aortic syndrome.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Humanos , Aorta , Enfermedad Aguda , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento
2.
Perfusion ; : 2676591241272009, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39089011

RESUMEN

INTRODUCTION: The ultimate answer to the question whether minimal invasive extracorporeal circulation (MiECC) represents the optimal perfusion technique in contemporary clinical practice remains elusive. The present study is a real-world study that focuses on specific perfusion-related clinical outcomes after cardiac surgery that could potentially be favourably affected by MiECC and thereby influence the future clinical practice. METHODS: The MiECS study is an international, multi-centre, two-arm randomized controlled trial. Patients undergoing elective or urgent coronary artery bypass grafting (CABG), aortic valve replacement (AVR) or combined procedure (CABG + AVR) using extracorporeal circulation will be randomized to MiECC or contemporary conventional cardiopulmonary bypass (cCPB). Use of optimized conventional circuits as controls is acceptable. The study design includes a range of features to prevent bias and is registered at clinicaltrials.gov (NCT05487612). RESULTS: The primary outcome is a composite of postoperative serious adverse events that could be related to perfusion technique occurring up to 30 days postoperatively. Secondary outcomes include use of blood products, ICU and hospital length of stay (30 days) as well as health-related quality of life (30 and 90 days). CONCLUSIONS: The MiECS trial has been designed to overcome perceived limitation of previous trials of MiECC. Results of the proposed study could affect current perfusion practice towards advancement of patient care.

3.
Perfusion ; : 2676591241258054, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38832503

RESUMEN

INTRODUCTION: The trial hypothesized that minimally invasive extra-corporeal circulation (MiECC) reduces the risk of serious adverse events (SAEs) after cardiac surgery operations requiring extra-corporeal circulation without circulatory arrest. METHODS: This is a multicentre, international randomized controlled trial across fourteen cardiac surgery centres including patients aged ≥18 and <85 years undergoing elective or urgent isolated coronary artery bypass grafting (CABG), isolated aortic valve replacement (AVR) surgery, or CABG + AVR surgery. Participants were randomized to MiECC or conventional extra-corporeal circulation (CECC), stratified by centre and operation. The primary outcome was a composite of 12 post-operative SAEs up to 30 days after surgery, the risk of which MiECC was hypothesized to reduce. Secondary outcomes comprised: other SAEs; all-cause mortality; transfusion of blood products; time to discharge from intensive care and hospital; health-related quality-of-life. Analyses were performed on a modified intention-to-treat basis. RESULTS: The trial terminated early due to the COVID-19 pandemic; 1071 participants (896 isolated CABG, 97 isolated AVR, 69 CABG + AVR) with median age 66 years and median EuroSCORE II 1.24 were randomized (535 to MiECC, 536 to CECC). Twenty-six participants withdrew after randomization, 22 before and four after intervention. Fifty of 517 (9.7%) randomized to MiECC and 69/522 (13.2%) randomized to CECC group experienced the primary outcome (risk ratio = 0.732, 95% confidence interval (95% CI) = 0.556 to 0.962, p = 0.025). The risk of any SAE not contributing to the primary outcome was similarly reduced (risk ratio = 0.791, 95% CI 0.530 to 1.179, p = 0.250). CONCLUSIONS: MiECC reduces the relative risk of primary outcome events by about 25%. The risk of other SAEs was similarly reduced. Because the trial terminated early without achieving the target sample size, these potential benefits of MiECC are uncertain.

4.
Cell Tissue Bank ; 25(1): 1-10, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37097383

RESUMEN

Homograft heart valves may have significant advantages and are preferred for the repair of congenital valve malformations, especially in young women of childbearing age, athletes and in patients with active endocarditis. A growing problem, however, is the mismatch between tissue donation and the increasing demand. The aim of this paper is to describe the initiation process of a homograft procurement program to attenuate the shortage of organs. A comprehensive description of the infrastructure and procedural steps required to initiate a cardiac and vascular tissue donation program combined with a prospective follow-up of all homografts explanted at our institution. Between January 2020 and May 2022, 28 hearts and 12 pulmonary bifurcations were harvested at our institution and delivered to the European homograft bank. Twenty-seven valves (19 pulmonary valves, 8 aortic valves) were processed and allocated for implantation. The reasons for discarding a graft were either contamination (n = 14), or morphology (n = 13) or leaflet damage (n = 2). Five homografts (3 PV, 2 AV) have been cryopreserved and stored while awaiting allocation. One pulmonary homograft with a leaflet cut was retrieved by bicuspidization technique and awaits allocation, as a highly requested small diameter graft. The implementation of a tissue donation program in cooperation with a homograft bank can be achieved with reasonable additional efforts at a transplant center with an in-house cardiac surgery department. Challenging situations with a potential risk of tissue injury during procurement include re-operation, harvesting by a non-specialist surgeon and prior central cannulation for mechanical circulatory support.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Donantes de Tejidos , Humanos , Femenino , Estudios Prospectivos , Trasplante Homólogo , Criopreservación , Aloinjertos
5.
Infection ; 51(1): 47-59, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35972680

RESUMEN

PURPOSE: Infective endocarditis (IE) is a severe bacterial infection. As a measure of prevention, the administration of antibiotic prophylaxis (AP) prior to dental procedures was recommended in the past. However, between 2007 and 2009, guidelines for IE prophylaxis changed all around the word, limiting or supporting the complete cessation of AP. It remains unclear whether AP is effective or not against IE. METHODS: We conducted a systematic review whether the administration of AP in adults before any dental procedure, compared to the non-administration of such drugs, has an effect on the risk of developing IE. We searched for studies in the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE via OVID, and EMBASE. Two different authors filtered articles independently and data extraction was performed based on a pre-defined protocol. RESULTS: The only cohort study meeting our criteria included patients at high-risk of IE. Analysis of the extracted data showed a non-significant decrease in the risk of IE when high-risk patients take AP prior to invasive dental procedures (RR 0.39, p-value 0.11). We did not find other studies including patients at low or moderate risk of IE. Qualitative evaluation of the excluded articles reveals diversity of results and suggests that most of the state-of-the-art articles are underpowered. CONCLUSIONS: Evidence to support or discourage the use of AP prior to dental procedures as a prevention for IE is very low. New high-quality studies are needed, even though such studies would require big settings and might not be immediately feasible.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Adulto , Humanos , Profilaxis Antibiótica , Estudios de Cohortes , Endocarditis Bacteriana/prevención & control , Endocarditis/prevención & control , Odontología
6.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36257545

RESUMEN

OBJECTIVES: The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR). METHODS: We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date: an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019). RESULTS: The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time. CONCLUSION: Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Procedimientos Quirúrgicos sin Sutura , Humanos , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Informe de Investigación , Resultado del Tratamiento , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Procedimientos Quirúrgicos sin Sutura/efectos adversos
7.
Eur Surg Res ; 64(3): 352-361, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37231808

RESUMEN

INTRODUCTION: The use of cardiopulmonary bypass (CBP; also known as a heart-lung machine) in newborns with complex congenital heart defects may result in brain damage. Magnetic resonance imaging (MRI) assessments cannot be performed safely because the metal components used to construct CBP devices may elicit adverse effects on patients when they are placed in a magnetic field. Thus, this project aimed to develop a prototype MR-conditional circulatory support system that could be used to perform cerebral perfusion studies in animal models. METHODS: The circulatory support device includes a roller pump with two rollers. The ferromagnetic and most of the metal components of the roller pump were modified or replaced, and the drive was exchanged by an air-pressure motor. All materials used to develop the prototype device were tested in the magnetic field according to the American Society for Testing and Materials (ASTM) Standard F2503-13. The technical performance parameters, including runtime/durability as well as achievable speed and pulsation behavior, were evaluated and compared to standard requirements. The behavior of the prototype device was compared with a commercially available pump. RESULTS: The MRI-conditional pump system produced no image artifacts and could be safely operated in the presence of the magnetic field. The system exhibited minor performance-related differences when compared to a standard CPB pump; feature testing revealed that the prototype meets the requirements (i.e., operability, controllability, and flow range) needed to proceed with the planned animal studies. CONCLUSION: This MR-conditional prototype is suitable to perform an open-heart surgery in an animal model to assess brain perfusion in an MR environment.


Asunto(s)
Puente Cardiopulmonar , Imagen por Resonancia Magnética , Animales , Puente Cardiopulmonar/métodos
8.
Perfusion ; 38(7): 1360-1383, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-35961654

RESUMEN

The landmark 2016 Minimal Invasive Extracorporeal Technologies International Society (MiECTiS) position paper promoted the creation of a common language between cardiac surgeons, anesthesiologists and perfusionists which led to the development of a stable framework that paved the way for the advancement of minimal invasive perfusion and related technologies. The current expert consensus document offers an update in areas for which new evidence has emerged. In the light of published literature, modular minimal invasive extracorporeal circulation (MiECC) has been established as a safe and effective perfusion technique that increases biocompatibility and ultimately ensures perfusion safety in all adult cardiac surgical procedures, including re-operations, aortic arch and emergency surgery. Moreover, it was recognized that incorporation of MiECC strategies advances minimal invasive cardiac surgery (MICS) by combining reduced surgical trauma with minimal physiologic derangements. Minimal Invasive Extracorporeal Technologies International Society considers MiECC as a physiologically-based multidisciplinary strategy for performing cardiac surgery that is associated with significant evidence-based clinical benefit that has accrued over the years. Widespread adoption of this technology is thus strongly advocated to obtain additional healthcare benefit while advancing patient care.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Adulto , Humanos , Procedimientos Quirúrgicos Cardíacos/métodos , Circulación Extracorporea/métodos , Perfusión , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Corazón
9.
Am J Transplant ; 21(3): 1003-1011, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32786170

RESUMEN

In donation after circulatory death (DCD), cardiac grafts are subjected to warm ischemia in situ, prior to a brief period of cold, static storage (CSS) at procurement, and ex situ, normothermic, machine perfusion (NMP) for transport and graft evaluation. Cold ischemia and normothermic reoxygenation during NMP could aggravate graft injury through continued accumulation and oxidation, respectively, of mitochondrial succinate, and the resultant oxidative stress. We hypothesized that replacing CSS with hypothermic, oxygenated perfusion (HOPE) could provide cardioprotection by reducing cardiac succinate levels before NMP. DCD was simulated in male Wistar rats. Following 21 minutes in situ ischemia, explanted hearts underwent 30 minutes hypothermic storage with 1 of the following: (1) CSS, (2) HOPE, (3) hypothermic deoxygenated perfusion (HNPE), or (4) HOPE + AA5 (succinate dehydrogenase inhibitor) followed by normothermic reperfusion to measure cardiac and metabolic recovery. After hypothermic storage, tissue ATP/ADP levels were higher and succinate concentration was lower in HOPE vs CSS, HNPE, and HOPE + AA5 hearts. After 60 minutes reperfusion, cardiac function was increased and cellular injury was decreased in HOPE compared with CSS, HNPE, and HOPE + AA5 hearts. HOPE provides improved cardioprotection via succinate oxidation prior to normothermic reperfusion compared with CSS, and therefore is a promising strategy for preservation of cardiac grafts obtained with DCD.


Asunto(s)
Trasplante de Corazón , Preservación de Órganos , Animales , Humanos , Masculino , Perfusión , Ratas , Ratas Wistar , Ácido Succínico , Donantes de Tejidos
10.
Artif Organs ; 45(1): 46-54, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32619302

RESUMEN

Hemolysis in cardiac surgery is often related to the contact of blood with air or artificial surfaces. Variations of negative pressure in the suction cannulas may represent an additional factor. Limited data exist on the contribution of a roller pump-assisted (RPA) cardiotomy suction unit to hemolysis. Elevation of free hemoglobin (fHb) following air suction (AS) or suction tip occlusion (STO) events of a pump-assisted cardiotomy suction unit was investigated in a mock circuit filled with blood from slaughtered domestic pigs. AS-associated hemolysis was measured over 240 minutes with 2 minutes of AS occurring every 10 minutes. STO-associated hemolysis was analyzed over 80-minute periods: configuration 1 (c1) comprised a cycle of 20 minutes (min) occlusion and 60 minutes RPA flow (20/60 minutes); c2 comprised 20 cycles of 1/3 minutes; c3 comprised 40 cycles of 0.5/1.5 minutes; and c4 comprised 80 cycles of 0.25/0.75 minutes. The AS setup did not lead to significant hemolysis after 2 (P = .97), 3 (P = .40) or 4 (P = .11) hours. The STO setup showed the greatest hemolysis (ΔfHb of 30 mg/dL) in c1 after 20 minutes. ΔfHb was different in c1 from all other configurations at 20 minutes (P < .0001) and 80 minutes (P < .05). Ex vivo generation of large negative pressures by STO events is the main cause of cardiotomy suction-associated hemolysis. The clinical relevance of this mechanism needs further investigations.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente Cardiopulmonar/efectos adversos , Hemólisis , Succión/efectos adversos , Animales , Puente Cardiopulmonar/instrumentación , Diseño de Equipo , Hemodinámica , Succión/instrumentación , Sus scrofa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA