Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Blood Purif ; 53(3): 162-169, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38113864

RESUMEN

Therapeutic plasma exchange (TPE) or plasmapheresis has been used in various life-threatening diseases as a primary treatment or in combination with other therapies. It was first successfully employed in the 1960s for diseases like Waldenström's disease and myeloma. Since then, TPE techniques using apheresis membranes have been introduced. Apheresis therapies separate plasma components from blood using membrane screening or centrifugation methods. TPE aims to remove substances involved in the pathophysiology of diseases. It selectively removes high-molecular-weight molecules, substances with prolonged half-life, and those associated with disease pathogenesis. TPE can be performed using membranes or centrifugation, with replacement of extracted plasma volume using albumin or fresh frozen plasma. TPE requires specific competencies in nephrology and can be prescribed and monitored by nephrologists and performed by dialysis nursing staff. TPE can be combined with adsorption-based therapies to enhance its effect, and this approach is called plasma filtration adsorption. Another variation is double plasma filtration, which selectively removes substances based on molecular size. TPE can also be combined with lipoprotein removal strategies for managing familial hypercholesterolemia. TPE is an affordable extracorporeal therapy that benefits patients with life-threatening diseases. It requires collaboration between nephrologists and other specialists, and our results demonstrate successful TPE without anticoagulation in general hospitalization or outpatient settings.


Asunto(s)
Eliminación de Componentes Sanguíneos , Nefrología , Humanos , Diálisis Renal , Eliminación de Componentes Sanguíneos/métodos , Intercambio Plasmático/métodos , Plasmaféresis/métodos
2.
Rev Gastroenterol Peru ; 39(4): 348-354, 2019.
Artículo en Español | MEDLINE | ID: mdl-32097395

RESUMEN

INTRODUCTION: Spontaneous bacterial peritonitis requires an early diagnosis to start antibiotic therapy. The ideal diagnostic study is the cytochemical of ascites fluid, which can be expensive, delayed and of limited availability in primary health care centers. OBJECTIVE: Evaluate the usefulness and diagnostic accuracy of Multistix 10SG test strips for the diagnosis of spontaneous bacterial peritonitis in cirrhotic patients with ascites. MATERIALS AND METHODS: Observational descriptive study of diagnostic test in cirrhotic patients with ascites. The leukocyte count of ascites fluid was determined by the colorimetric scale of the Multistix 10SG test strip and compared with the gold standard for diagnosis (polymorphonuclear ≥ 250 cells / mm³). RESULTS: Of 174 patients with ascites (51.7% women, average age 59 years) 30 were diagnosed with spontaneous bacterial peritonitis. With a grade ++ cut-off point, the test strip had sensitivity 73.3%, specificity 96.5%, positive predictive value 81.4%, negative predictive value 94.5%, positive likelihood ratio 21.2 and negative likelihood ratio of 0.27. CONCLUSIONS: The test strips have adequate specificity and negative predictive value, being a low cost tool, simple use, quick interpretation and easy access, to support the decision not to start an antibiotic in patients with ascites and suspected spontaneous bacterial peritonitis. Due to their low sensitivity they do not replace the cytochemical study as the test of choice for the definitive diagnosis, but it is useful for optimizing the initial approach of these patients.


Asunto(s)
Ascitis/complicaciones , Infecciones Bacterianas/diagnóstico , Diagnóstico Precoz , Cirrosis Hepática/complicaciones , Peritonitis/diagnóstico , Tiras Reactivas , Ascitis/microbiología , Infecciones Bacterianas/microbiología , Femenino , Humanos , Recuento de Leucocitos , Cirrosis Hepática/microbiología , Masculino , Persona de Mediana Edad , Peritonitis/microbiología , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
3.
Eur J Clin Nutr ; 78(10): 919-921, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39060544

RESUMEN

Malnutrition is a prevalent condition in chronic diseases, significantly impacting morbidity and mortality. Point-of-care ultrasound (POCUS) is increasingly utilized in clinical practice as a rapid and accessible tool for evaluating muscle mass. Here, we present two cases of females with chronic diseases who presented with acute exacerbations of their conditions accompanied by fluid overload. Suspected of experiencing nutritional alterations, they underwent ultrasound evaluation to confirm muscle mass loss. These cases highlight the potential of ultrasound in guiding effective muscle mass assessment, particularly in pathologies prone to fluid overload, such as chronic kidney disease and heart failure.


Asunto(s)
Índice de Masa Corporal , Desnutrición , Ultrasonografía , Humanos , Femenino , Ultrasonografía/métodos , Músculo Esquelético/diagnóstico por imagen , Anciano , Persona de Mediana Edad , Estado Nutricional , Evaluación Nutricional , Sistemas de Atención de Punto , Insuficiencia Renal Crónica/complicaciones
4.
Rev. gastroenterol. Perú ; 39(4): 348-354, oct.-dic 2019. ilus, tab
Artículo en Español | LILACS | ID: biblio-1144620

RESUMEN

Introducción: La peritonitis bacteriana espontánea requiere un diagnóstico temprano para el inicio de antibioticoterapia. El estudio diagnóstico ideal es el citoquímico del líquido ascítico, el cual puede ser costoso, demorado y de disponibilidad limitada en centros primarios de atención en salud. Objetivo: Evaluar la utilidad y precisión diagnóstica de las tiras reactivas Multistix 10SG para el diagnóstico de peritonitis bacteriana espontánea en pacientes cirróticos con ascitis. Materiales y métodos: Estudio observacional descriptivo de prueba diagnóstica en pacientes cirróticos con ascitis. Se determinó el conteo de leucocitos del líquido ascítico por la escala colorimétrica de la tira reactiva Multistix 10SG y se comparó con el gold standard para el diagnóstico (polimorfonucleares ≥ 250 células/mm³). Resultados: De 174 pacientes con ascitis (51,7% mujeres, promedio de edad 59 años) 30 fueron diagnosticados con peritonitis bacteriana espontánea. Con un punto de corte grado ++, la tira reactiva tuvo sensibilidad 73,3%, especificidad 96,5%, valor predictivo positivo 81,4%, valor predictivo negativo 94,5%, razón de probabilidad positiva 21,2 y razón de probabilidad negativa 0,27. Conclusiones: Las tiras reactivas tienen adecuada especificidad y valor predictivo negativo, siendo una herramienta de bajo costo, uso sencillo, rápida interpretación y fácil acceso, para apoyar la decisión de no iniciar antibiótico en pacientes con ascitis y sospecha de peritonitis bacteriana espontánea. Por su baja sensibilidad no reemplazan al estudio citoquímico como prueba de elección para el diagnóstico definitivo, pero si es útil para optimizar el abordaje inicial de estos pacientes.


Introduction: Spontaneous bacterial peritonitis requires an early diagnosis to start antibiotic therapy. The ideal diagnostic study is the cytochemical of ascites fluid, which can be expensive, delayed and of limited availability in primary health care centers. Objective: Evaluate the usefulness and diagnostic accuracy of Multistix 10SG test strips for the diagnosis of spontaneous bacterial peritonitis in cirrhotic patients with ascites. Materials and methods: Observational descriptive study of diagnostic test in cirrhotic patients with ascites. The leukocyte count of ascites fluid was determined by the colorimetric scale of the Multistix 10SG test strip and compared with the gold standard for diagnosis (polymorphonuclear ≥ 250 cells / mm³). Results: Of 174 patients with ascites (51.7% women, average age 59 years) 30 were diagnosed with spontaneous bacterial peritonitis. With a grade ++ cut-off point, the test strip had sensitivity 73.3%, specificity 96.5%, positive predictive value 81.4%, negative predictive value 94.5%, positive likelihood ratio 21.2 and negative likelihood ratio of 0.27. Conclusions: The test strips have adequate specificity and negative predictive value, being a low cost tool, simple use, quick interpretation and easy access, to support the decision not to start an antibiotic in patients with ascites and suspected spontaneous bacterial peritonitis. Due to their low sensitivity they do not replace the cytochemical study as the test of choice for the definitive diagnosis, but it is useful for optimizing the initial approach of these patients.


Asunto(s)
Femenino , Humanos , Masculino , Persona de Mediana Edad , Peritonitis/diagnóstico , Ascitis/complicaciones , Tiras Reactivas , Infecciones Bacterianas/diagnóstico , Diagnóstico Precoz , Cirrosis Hepática/complicaciones , Peritonitis/microbiología , Ascitis/microbiología , Infecciones Bacterianas/microbiología , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Recuento de Leucocitos , Cirrosis Hepática/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA