Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38978283

RESUMEN

INTRODUCTION: The QDOT MICROTM Ablation Catheter is a next-generation ablation catheter that allows for high-power ablation up to 90 watts. METHODS: We aimed to assess AE associated with the QDOT MICROTM catheter using the MAUDE database. A MAUDE database search was conducted on May 25, 2024, to capture all AEs (since FDA approval) associated with this ablation catheter. RESULTS: A total of 302 AEs from November 23, 2022, to April 30, 2024, were reported including 148 (49%) catheter-related issues and 154 (51%) clinical complications. Among the catheter-related issues, physical catheter damage (74.3%, n = 110) was most common, followed by communication or display issue (10.8%, n = 16), irrigation issue (9.5%, n = 14), signal issue or artifact (3.4%, n = 5), and inaccurate temperature measurement (2.0%, n = 3). Regarding clinical complications, the most common AE was pericardial effusion (43.5%, n = 67), followed by char formation (11.7%, n = 18), catheter thrombosis (7.1%, n = 11), stroke (7.1%, n = 11), pericarditis (7.1%, n = 11), esophageal complications (6.5%, n = 10), phrenic nerve palsy (3.9%, n = 6), cardiac arrest (3.9%, n = 6), significant AV block (3.9%, n = 6), pulmonary vein stenosis (3.2%, n = 5), coronary artery spasm (1.3%, n = 2), and pulmonary embolism (0.6%, n = 1). There were 11 deaths (five related to esophageal complications, five related to cardiac arrest, and one related to pericardial effusion with cardiac tamponade). CONCLUSION: As high-power ablation strategy with novel ablation catheters is becoming more widely utilized, operators must be aware of potential catheter-related issues and clinical complications that may arise. More data are needed to further evaluate risks of these complications to improve the catheter's safety and efficacy.

2.
J Cardiovasc Electrophysiol ; 34(11): 2382-2385, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37679961

RESUMEN

BACKGROUND: Dual occlusive closure mechanism (disc and lobe type), Amulet device (Abbott; a second-generation device that has replaced Amplatzer Cardiac Plug) was approved by the Food and Drug Administration (FDA) in August 2021 for percutaneous left atrial appendage occlusion (LAAO). However, real-world safety data on the delivery system (Amplatzer Cardiac Plug and Amplatzer Amulet device) are lacking. OBJECTIVE: We sought to assess the type of adverse events associated with the Amplatzer LAAO delivery system using the FDA Manufacturer and User Facility Device Experience (MAUDE) database. METHODS: A MAUDE database search was conducted on March 31, 2023, for reports received between February 2013 and March 2023 to capture all adverse events. RESULTS: A total of 59 adverse events were reported, of which 58 were sheath-related events, and one was a wire-related event. The most commonly encountered issue was air embolism (19%, 11 events), followed by sheath thrombosis (13.8%, eight events, two of which were also associated with device thrombosis), kinked sheath (10.3%, six events), and sheath deformation (8.6%, five events). Patient-related adverse events included pericardial effusion requiring pericardiocentesis (22.4%, 13 events), vascular complications (20.7%, 12 events), and device dislodgement (5.2%, three events). CONCLUSION: LAAO-related adverse events are increasingly being reported using the Amplatzer LAAO delivery sheath. It is anticipated that improvements in device technology, the advent of steerable sheaths, and operator experience will minimize these complications.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Trombosis , Estados Unidos , Humanos , Apéndice Atrial/diagnóstico por imagen , United States Food and Drug Administration , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco/efectos adversos , Trombosis/etiología , Resultado del Tratamiento , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Dispositivo Oclusor Septal/efectos adversos
3.
J Cardiovasc Electrophysiol ; 34(1): 219-224, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36335616

RESUMEN

BACKGROUND: Monomorphic ventricular tachycardia (VT) is rare in patients with hypertrophic cardiomyopathy (HCM), management of which is challenging. Limited data exists on the utility of catheter ablation for the treatment of VT in this population. OBJECTIVES: We aimed to assess clinical outcomes of catheter ablation for VT in HCM patients. METHODS: A systematic search, without language restriction, using PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov was performed. The meta-analysis was performed using a meta-package for R version 4.0/RStudio version 1.2 and Freeman Tukey double arcsine method to establish the variance of raw proportions. Outcomes measured included (1) acute procedure success (defined as noninducible for clinical VT), (2) freedom from VT at follow-up, (3) mortality. RESULTS: This systematic review of six studies (three from the United States and three from Japan) incorporated a total of 68 drug-refractory HCM patients who underwent VT radiofrequency catheter ablation (mean age 57.6 ± 13.3 years, mean LVEF 45.8 ± 15.4%, 85% men, maximum septal wall thickness 17.4 ± 4.6 mm, and 32.3% with an apical aneurysm). Acute procedural success was achieved in 84.5% patients (95% confidence interval [CI]: 70.6%-95.2%) with 27.9% patients had recurrent VT requiring multiple ablations (median 1, IQR 1-3). During the follow-up period (18.3 ± 11.7 months), the pooled incidence of freedom from recurrent VT after index procedure was 70.2% (95% CI: 51.9%-86.2%), while after the last ablation was 82.8% (95% CI: 57%-99.2%). There were two deaths during follow-up, one from heart failure and one from SCD 0.8% (95% CI: 0%-5.8%). CONCLUSION: The results of our pooled analysis demonstrated that catheter ablation for VT in HCM patients was associated with high acute procedural success, and reduced VT recurrence-findings comparable to previously published reports in other disease substrates.


Asunto(s)
Cardiomiopatía Hipertrófica , Ablación por Catéter , Insuficiencia Cardíaca , Taquicardia Ventricular , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Femenino , Recurrencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ablación por Catéter/métodos , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 34(6): 1469-1471, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37209414

RESUMEN

BACKGROUND: Leadless pacemaker (LP) offers an innovative approach for treating bradyarrhythmia, thus avoiding pacemaker pocket and lead-related complications. The Food and Drug Administration (FDA) has recently approved the Aveir™ leadless pacing system (screw-in type LP). METHODS: We queried the FDA MAUDE database to study the safety profile and assess the types of complications with this relatively novel device technology. A MAUDE database search was conducted on January 20, 2023, for reports received post-FDA approval to capture all adverse events. RESULTS: A total of 98 medical device report were reported for Aveir™ LP. After excluding duplicate, programmer-related, or introducer-sheath-related entries (n = 34), 64 entries were included. The most commonly encountered problem was high threshold/noncapture (28.1%, 18 events), followed by stretched helix (17.2%, 11 events) and device dislodgement (15.6%, ten events-5 intraprocedural, while 5 in the postoperative Day 1). Other reported events included high impedance (14.1%, nine events), sensing issues (12.5%, eight events), bent/broken helix (7.8%, five events), premature separation (4.7%, three events), interrogation problem (3.1%, two events), low impedance (3.1%, two events), premature battery depletion (1.6%, one event) and inadvertent MRI mode switch (1.6%, one event) and miscellaneous (15.6%, n = 10). There were eight serious patient injury events-pericardial effusion requiring pericardiocentesis (7.8%, five events) due to cardiac perforation that resulted in two deaths (3.1%) followed by sustained ventricular arrhythmias (4.6%, n = 3). CONCLUSION: In our study assessing the real-world safety profile of the Aveir™ LP, serious adverse events have been reported-life-threatening ventricular arrhythmias, pericardial effusion, device explantation/reimplantation, and death.


Asunto(s)
Marcapaso Artificial , Derrame Pericárdico , Realidad Virtual , Estados Unidos , Humanos , United States Food and Drug Administration , Derrame Pericárdico/etiología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Marcapaso Artificial/efectos adversos
5.
J Cardiovasc Electrophysiol ; 33(11): 2382-2388, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36153661

RESUMEN

Intracardiac echocardiography (ICE) has become an essential tool and is an integral part of percutaneous interventional and electrophysiology (EP) procedures. Intracardiac echocardiography offers real-time, high-quality, near-field evaluation of cardiac anatomy. Standard ICE imaging includes placing the catheter in the right atrium (RA), right ventricle (RV), or left atrium (LA, via the transeptal approach). Coronary sinus echocardiography (CSE) is another alternative, where the ICE catheter is positioned in the coronary sinus (CS). This approach offers better catheter stability and allows operators to visualize cardiac structure with particularly excellent views of the LA, LAA, left ventricle (LV), and mitral annulus. Additionally, CSE is an attractive alternative in cases with unfavorable interatrial septum or fossa ovalis anatomical features that could lead to difficulty advancing ICE catheter in left atrium. In this article focusing on CSE, we provide illustration-based guidance to help operators identify critical cardiac structures from CSE.


Asunto(s)
Seno Coronario , Humanos , Seno Coronario/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Ecocardiografía , Atrios Cardíacos , Válvula Mitral , Cateterismo Cardíaco/métodos
6.
Rev Cardiovasc Med ; 23(1): 34, 2022 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-35092226

RESUMEN

BACKGROUND: Perioperative anticoagulation management with uninterrupted or minimally interrupted anticoagulation during atrial fibrillation (AF) ablation is thought to be critical to minimize thromboembolic complications. Protamine is often administered to neutralize the effects of heparin and expedite vascular hemostasis post-procedure. OBJECTIVE: We performed a systematic review and meta-analysis to determine the effectiveness of protamine to expedite vascular hemostasis and ambulation in patients undergoing AF ablation. METHODS: Electronic searches on PubMed, The Cochrane Library, EMBASE, EBSCO, Web of Science, and CINAHL databases from the inception through August 7, 2021, were performed. The primary outcomes included-time to hemostasis (minutes) and time to ambulation (minutes). The secondary outcomes included - any vascular complications (excluding minor hematoma), minor hematoma, or cerebrovascular accidents (CVA). RESULTS: A total of 5 eligible studies (3 retrospective cohort studies and two randomized trials) consisting of 1012 patients (515 patients received protamine group and 497 patients did not receive protamine group) were included in the meta-analysis. There was a significant reduction in time to ambulation [weighted mean difference (WMD) -176.6 minutes, 95% Confidence interval (CI) -266.9 to -86.3; p < 0.01] and time to hemostasis (WMD -13.72 minutes, 95% CI -22 to -5.4, p < 0.01) in the protamine group compared to the contrary. At a follow-up up to 3 months, there was no statistical difference between the two groups with regards to vascular complications (2.9% vs. 7.4%; Risk ratio (RR) 0.46 95% CI 0.17 to 1.24; p = 0.12), minor hematoma (2.1% vs. 5.8%; RR 0.43, 95% CI 0.16 to 1.2; p = 0.11) or CVA (0 vs. 0.3%; RR 0.62, 95% CI 0.08 to 4.98; p = 0.65). CONCLUSION: Protamine administration was associated with reduced time to ambulation (176 minutes reduction) and time to hemostasis (13 minutes reduction) without an increase in any adverse events.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anticoagulantes/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Protaminas/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
7.
Pacing Clin Electrophysiol ; 45(12): 1379-1382, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35768884

RESUMEN

Left ventricular assist devices (LVAD) have been increasingly utilized end-stage heart failure despite guidelinedirected medical therapy (due to limited organ availability) as a bridge to transplant or destination therapy, with improved overall survival.Majority of patients undergoing LVAD implantation have pre-existing implantable cardioverter-defibrillator (ICD) in-situ.We present a case of device-device interaction resulting in EMI inducing recurrent inappropriate device therapies inducing ventricular arrhythmia followed by the inappropriate triggering of noise reversion mode, thereby inhibiting device therapies.With the increase in number of end-stage heart failure patients with ICDs in situ (and limited organ availability) undergoing LVAD implantation, it is imperative to recognize potential device-device interactions to avoid unwarranted invasive interventions.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Taquicardia Ventricular , Humanos , Corazón Auxiliar/efectos adversos , Taquicardia Ventricular/terapia , Insuficiencia Cardíaca/terapia
8.
Pacing Clin Electrophysiol ; 45(4): 567-570, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35199863

RESUMEN

BACKGROUND: Thromboembolic (TE) events are among the most common and devastating adverse events in patients with continuous-flow left ventricular assist device (cf-LVAD). Given the high burden of AF among cf-LVAD patients, we sought to evaluate the effect of concomitant surgical LAAO in patients receiving cf-LVAD. METHODS: A systematic search using electronic databases was performed using the keywords: "left atrial appendage occlusion" and "left ventricular assist device." Statistical analysis was performed using metapackage for R version 4.0 and Rstudio version 1.2. Mantel-Haenszel risk ratio (RR) random-effects model was used to summarize data between two groups. The primary outcomes included: (a) stroke; (b) LVAD pump thrombosis; (c) all-cause mortality RESULTS: Three studies with a total of 305 patients (LAAO = 68 and No-LAAO = 237) were included in the analysis. HeartMate II (39%) and Heartware (27.5%) were the two most common cf-LVADs utilized, while only 5% received HeartMate III. At a mean follow up of 1.47 years, LAAO group had a lower risk of stroke (8.8% vs. 15.2%, RR 0.64; 95% CI 0.28-1.49), LVAD pump thrombosis (1.5% vs. 3.8%, RR 0.28; 95% CI 0.05-1.55) and all-cause mortality (5.9% vs. 20.2%, RR 0.69; 95% CI 0.19-2.52) when compared with no-LAAO group, but the difference did not reach statistical significance. CONCLUSION: Concomitant surgical LAAO at the time of cf-LVAD implantation demonstrated a trend toward positive outcomes and was not associated with adverse outcomes during the follow-up period, though the results were not statistically significant.


Asunto(s)
Apéndice Atrial , Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Tromboembolia , Trombosis , Apéndice Atrial/cirugía , Insuficiencia Cardíaca/complicaciones , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/complicaciones , Tromboembolia/etiología , Trombosis/etiología , Resultado del Tratamiento
9.
Pacing Clin Electrophysiol ; 44(5): 765-772, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33813740

RESUMEN

BACKGROUND: Guidance for wound management of the vacated generator pocket in cardiac implantable electronic device (CIED) pocket infections after removal of all hardware and tissue debridement is limited. The typical surgical technique for management of a purulent wound is to allow healing by secondary intention. An alternative approach uses negative pressure wound therapy with or without delayed primary closure. While effective in managing infection, these approaches increase hospital length of stay and costs. We present our experience with a third option: modified early primary wound closure over a suction device. METHODS: All patients with CIED pocket infections who presented to our institution between September 2018 and October 2020 underwent extraction of hardware and modified primary wound closure over a negative pressure Jackson-Pratt drain. Length of hospital and postoperative stay, complications, and recurrent infections were recorded. RESULTS: During the study period, 14 patients underwent modified primary wound closure for CIED pocket infections. Mean length of hospital stay was 6.64 days ± 4.01 days (standard deviation [SD]). Mean postoperative length of stay was 3.92 ± 2.21 days (SD). Two patients (both on intravenous heparin for mechanical valve prostheses) required re-exploration for bleeding. No patients developed recurrent infection at a mean follow up of 363 ± 245 days (SD). CONCLUSION: Based on our experience, early modified primary wound closure for CIED pocket infections appears to be safe and allows for prompt discharge with no observed re-infections.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Remoción de Dispositivos , Infecciones Relacionadas con Prótesis/cirugía , Técnicas de Cierre de Heridas , Anciano , Antibacterianos/uso terapéutico , Femenino , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino
10.
Int J Clin Pract ; 75(4): e13841, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33220158

RESUMEN

AIMS: There are limited data on the management and outcomes of chronic liver disease (CLD) patients presenting with acute myocardial infarction (AMI), particularly according to the subtype of CLD. METHODS: Using the Nationwide Inpatient Sample (2004-2015), we examined outcomes of AMI patients stratified by severity and sub-types of CLD. Multivariable logistic regression was performed to assess the adjusted odds ratios (aOR) of receipt of invasive management and adverse outcomes in CLD groups compared with no-CLD. RESULTS: Of 7 024 723 AMI admissions, 54 283 (0.8%) had a CLD diagnosis. CLD patients were less likely to undergo coronary angiography (CA) and percutaneous coronary intervention (PCI) (aOR 0.62, 95%CI 0.60-0.63 and 0.59, 95%CI 0.58-0.60, respectively), and had increased odds of adverse outcomes including major adverse cardiovascular and cerebrovascular events (1.19, 95%CI 1.15-1.23), mortality (1.30, 95%CI 1.25-1.34) and major bleeding (1.74, 95%CI 1.67-1.81). In comparison to the non-severe CLD sub-groups, patients with all forms of severe CLD had the lower utilization of CA and PCI (P < .05). Among severe CLD patients, those with alcohol-related liver disease (ALD) had the lowest utilization of CA and PCI; patients with ALD and other CLD (OCLD) had more adverse outcomes than the viral hepatitis sub-group (P < .05). CONCLUSIONS: CLD patients presenting with AMI are less likely to receive invasive management and are associated with worse clinical outcomes. Further differences are observed depending on the type as well as severity of CLD, with the worst management and clinical outcomes observed in those with severe ALD and OCLD.


Asunto(s)
Hepatopatías , Infarto del Miocardio , Intervención Coronaria Percutánea , Angiografía Coronaria , Hemorragia , Mortalidad Hospitalaria , Humanos , Hepatopatías/complicaciones , Hepatopatías/epidemiología , Hepatopatías/terapia , Infarto del Miocardio/epidemiología , Infarto del Miocardio/terapia , Resultado del Tratamiento
11.
Europace ; 22(7): 1083-1096, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32361739

RESUMEN

AIMS: To study the outcomes of cancer patients undergoing cardiac implantable electronic device (CIED) implantation. METHODS AND RESULTS: De novo CIED implantations (2004-15; n = 2 670 590) from the National Inpatient Sample were analysed for characteristics and in-hospital outcomes, stratified by presence of cancer (no cancer, historical and current cancers) and further by current cancer type (haematological, lung, breast, colon, and prostate). Current and historical cancer prevalence has increased from 3.3% to 7.8%, and 5.8% to 7.8%, respectively, between 2004 and 2015. Current cancer was associated with increased adjusted odds ratio (OR) of major adverse cardiovascular events (MACE) [composite of all-cause mortality, thoracic and cardiac complications, and device-related infection; OR 1.26, 95% confidence interval (CI) 1.23-1.30], all-cause mortality (OR 1.43, 95% CI 1.35-1.50), major bleeding (OR 1.38, 95% CI 1.32-1.44), and thoracic complications (OR 1.39, 95% CI 1.35-1.43). Differences in outcomes were observed according to cancer type, with significantly worse MACE, mortality and thoracic complications with lung and haematological malignancies, and increased major bleeding in colon and prostate malignancies. The risk of complications was also different according to CIED subtype. CONCLUSION: The prevalence of cancer patients amongst those undergoing CIED implantation has significantly increased over 12 years. Overall, current cancers are associated with increased mortality and worse outcomes, especially in patients with lung, haematological, and colon malignancies whereas there was no evidence that historical cancer had a negative impact on outcomes.


Asunto(s)
Desfibriladores Implantables , Neoplasias , Marcapaso Artificial , Electrónica , Hospitales , Humanos , Masculino , Neoplasias/epidemiología , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Estados Unidos/epidemiología
14.
Am J Ther ; 22(5): 377-81, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-24451300

RESUMEN

Previous case reports and small studies have suggested that 3-hydroxy-3-methylglutaryl-CoA reductase inhibitors (HMG-CoA-Is) may increase the risk of tendon rupture. We conducted a population-based retrospective cohort evaluation to better assess this relationship. From approximately 800,000 enrollees of a private insurance database, those who were aged ≤64 years with at least 1 year of continuous enrollment were selected. Exposure was defined as initiation of HMG-CoA-I after the beginning of the study period. Each exposed person was matched with 2 controls of similar age and gender. Baseline characteristics, including known risk factors for tendon rupture, were compared between exposed and control cohorts with fidelity to the study's matched design. After adjusting for differences in follow-up and baseline characteristics, incidence rate ratios for tendon rupture was assessed in HMG-CoA-I users and nonusers. A total of 34,749 exposed patients were matched with 69,498 controls. There was no difference in the occurrence of tendon ruptures in HMG-CoA-I users versus nonusers. The results remained unchanged after adjustment for age and gender. In conclusion, this population-based retrospective cohort evaluation suggests that use of HMG-CoA-Is as a group are not associated with tendon rupture.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Traumatismos de los Tendones/epidemiología , Adulto , Femenino , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Revisión de Utilización de Seguros , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Rotura
15.
Artículo en Inglés | MEDLINE | ID: mdl-38443707

RESUMEN

INTRODUCTION: Cardiac implantable electronic device (CIED) functions are susceptible to electromagnetic interference (EMI) from electromagnetic fields (EMF). Data on EMI risks from new-generation electronic appliances (EA) are limited. OBJECTIVE: We performed a systematic literature review on the mechanisms of EMI, current evidence, and recently published trials evaluating the effect of EMF on CIEDs from electric vehicles (EV), smartphone, and smartwatch technology and summarize its safety data. METHODS: Electronic databases, including PubMed and EMBASE, were searched for in vivo studies evaluating EMF strength and incidence between CIEDs and commercial EVs, new-generation smartphones, and new-generation smartwatches. RESULTS: A total of ten studies (three on EVs, five on smartphones, one on smartphones, one on smartphones and smartwatches) were included in our systematic review. There was no report of EMI incidence associated with EVs or smartwatches. Magnet-containing smartphones (iPhone 12) can cause EMI when placed directly over CIEDs - thereby triggering the magnet mode; otherwise, no report of EMI was observed with other positions or smartphone models. CONCLUSION: Current evidence suggests CIED recipients are safe from general interaction with EVs/HEVs, smartphones, and smartwatches. Strictly, results may only be applied to commercial brands or models tested in the published studies. There is limited data on EMI risk from EVs wireless charging and smartphones with MagSafe technology.

16.
Artículo en Inglés | MEDLINE | ID: mdl-39256235

RESUMEN

BACKGROUND: The safety and efficacy of CA for AF and left-sided atrial arrhythmias (AA) in patients with left atrial appendage occlusion (LAAO) devices are lacking. METHODS: This is a single-center retrospective registry that included all patients with prior LAAO who underwent catheter ablation for AF or left-sided atrial arrhythmia from January 2020-January 2023. The primary outcomes were procedure-related complications, device-related complications, AA recurrence, and stroke. RESULTS: A total of 30 patients with prior LAAO were included in the analysis (mean age 75.1 ± 7.1 years old, 50% male, mean CHA2DS2-VASc score 4 ± 1.6, 46.7% paroxysmal AF, 73.3% had prior AF ablation, mean time to ablation 475 ± 365 days). 93.3% (n = 28) and 6.6% (n = 2) patients had ablation for AF (46.7% paroxysmal, 36.7% persistent, 10% long-standing persistent) and left-sided atrial tachycardia, respectively. 16.7% (n = 5) patients underwent ablation along the left atrial appendage ostium, and 3.3% (n = 1) underwent Vein of Marshall alcohol ablation. There were 3 (10%) peri-procedural complications (1 access hematoma and two pericardial effusions requiring intervention-none related to left atrial appendage ostium or alcohol ablation). During the mean follow-up of 440 ± 379 days, 40% (n = 12) patients had AA recurrence (91.6% AF, 8.3% atrial tachycardia), of which five patients needed repeat ablation, and two patients were readmitted for heart failure. There was no stroke or any device-related complications, including new peri-device leaks or device-related thrombosis in patients who had follow-up imaging studies (n = 11, 36.7%). CONCLUSION: Catheter ablation for AF (including VoM alcohol ablation) in patients with prior LAAO devices is feasible and safe with favorable outcomes.

17.
J Heart Valve Dis ; 22(1): 36-8, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23610986

RESUMEN

Non-bacterial endocarditis lesions associated with antiphospholipid antibodies (aPLs) in the absence of other criteria for antiphospholipid syndrome or systemic lupus erythematosus is termed an aPL-associated cardiac valve disease. Evidence regarding the management of this condition is sparse. A rare case is described of a 20-year-old female who presented with an incidental finding of 'vegetations on a heart valve'. Echocardiography revealed mitral valve leaflet thickening and echodensities with moderate mitral regurgitation. She had an elevated partial thromboplastin time that did not correct with a mixing study, and elevated levels of antiocardiolipin antibodies. Hence, a diagnosis of aPL-associated cardiac valve disease was made, and the patient commenced on warfarin, hydroxychloroquine, and a short course of oral prednisone. At one year after diagnosis the patient remained symptom-free, and follow up echocardiography revealed resolution of the vegetations with minimal mitral regurgitation. Further evidence is needed to guide the therapy of this rare condition.


Asunto(s)
Anticoagulantes/uso terapéutico , Endocarditis no Infecciosa/tratamiento farmacológico , Hidroxicloroquina/uso terapéutico , Válvula Mitral , Warfarina/uso terapéutico , Anticuerpos Anticardiolipina/sangre , Quimioterapia Combinada , Endocarditis no Infecciosa/complicaciones , Endocarditis no Infecciosa/diagnóstico , Endocarditis no Infecciosa/inmunología , Femenino , Glucocorticoides/uso terapéutico , Humanos , Inmunomodulación , Insuficiencia de la Válvula Mitral/complicaciones , Prednisona/uso terapéutico , Adulto Joven
18.
J Innov Card Rhythm Manag ; 14(6): 5482-5487, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37388424

RESUMEN

Inadvertent lead misplacement in the left ventricle can lead to thromboembolic events, valvular damage, and endocarditis. We present a case of an inadvertently placed transarterial pacemaker lead in the left ventricle in a patient who underwent percutaneous lead removal. After a multidisciplinary team discussion involving cardiac electrophysiology and interventional cardiology as well as a discussion of treatment options with the patient, it was decided to proceed with pacemaker lead removal with the Sentinel™ Cerebral Protection System (Boston Scientific, Marlborough, MA, USA) to prevent thromboembolic events. The patient tolerated the procedure well without post-procedural complications and was discharged the next day on oral anticoagulation. We also present a step-by-step approach to perform lead removal with the use of Sentinel™, emphasizing mitigating the stroke and bleeding risks in this patient setting.

19.
Am J Cardiol ; 208: 153-155, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37839459

RESUMEN

Evidence regarding racial disparities in leadless pacemaker (LP) utilization and outcomes is limited. We aimed to explore ethnicity-based disparities in LP utilization and clinical outcomes of patients who underwent LP implantation. All consecutive patients who underwent LP between January 2019 and January 2023 at our institution were included. Charts were reviewed for baseline characteristics and clinical outcomes. The primary outcomes were procedure-related complications, cardiac rehospitalization, worsening heart failure (HF) or HF hospitalization, and all-cause mortality. All statistical analyses were performed using SPSS Statistics 22 (IBM Corp., Armonk, NY). The p <0.05 was considered statistically significant. A total of 196 adult patients underwent LP implantation during the study period (48% Caucasians, 36.2% Hispanic, 8.2% Asians, and 7.7% African-American). The groups were balanced with respect to baseline demographics, clinical characteristics, and procedure-related complications. During the median follow-up of 104 days (interquartile range 24 to 382), no statistically significant differences were observed in worsening HF or HF hospitalization or all-cause mortality among the ethnic groups. After multivariable logistic regression, Asian individuals had higher odds of cardiac readmissions (odds ratio 4.1, 95% confidence interval 1.4 to 12.3, p = 0.01). Patients from racial and ethnic minorities face significant inequities in arrhythmia care, including patients who have undergone LP implantation. Awareness and a system-based approach (understanding cultural preferences, effective application of evidence-based guidelines, and population-based policies) are crucial to lessen disparities in health care among minorities.


Asunto(s)
Etnicidad , Disparidades en Atención de Salud , Marcapaso Artificial , Grupos Raciales , Adulto , Humanos , Estados Unidos
20.
J Interv Card Electrophysiol ; 66(3): 561-566, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35469052

RESUMEN

BACKGROUND: There has been increasing interest in physiologic pacing techniques that directly activate the specialized conduction system. We aimed to assess outcomes of conduction system pacing (CSP) in patients with prosthetic heart valves. METHODS: This systematic review was performed according to PRISMA guidelines. Freeman-Tukey double arcsine transformation with the random-effect model was used to summarize the data. Outcomes studied were 1) implant success (defined as ability to recruit the His-Purkinje system or the distal Purkinje system); (2) lead parameters at implant and follow-up; and (3) procedure-related complications. RESULTS: This systematic review of 7 studies included 267 unique patients in whom CSP was attempted with either HBP or LBBAP for pacing indications after a prosthetic valve. HBP was attempted in 38% (n = 108), while LBBAP in 62% (n = 175) patients. The overall success rate of CSP was 87%, while in patients post-TAVR, the overall success rate was 83.2%. In the subgroup analysis, LBBAP had a significant higher overall success rate compared to HBP (94.3% vs. 76.5%, p interaction = 0.02) and post-TAVR patients (94.3 vs. 66.9%, p interaction < 0.01), respectively. The LBBAP thresholds were significantly lower compared to HBP both at implant (0.67 ± 0.4 @ 0.44 ms vs. 1.35 ± 1 @ 0.85 ms, p interaction < 0.01) and at a mean follow-up of 12.4 ± 8 months (0.73 ± 0.1 @ 0.44 ms vs. 1.39 ± 1 @ 0.85 ms, p interaction < 0.01), respectively. CONCLUSION: CSP is safe and feasible in patients with a prosthetic valve, with a significantly higher success rate and superior lead parameters with LBBAP than HBP, especially in patients post-TAVR.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Humanos , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco , Válvulas Cardíacas , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA