Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 87(6): 3115-22, 2015 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-25708099

RESUMEN

Miniaturized mass spectrometers are becoming increasingly capable, enabling the development of many novel field and laboratory applications. However, to date, triple quadrupole tandem mass spectrometers, the workhorses of quantitative analysis, have not been significantly reduced in size. Here, the basis of a field-deployable triple quadrupole is described. The key development is a highly miniaturized ion optical assembly in which a sequence of six microengineered components is employed to generate ions at atmospheric pressure, provide a vacuum interface, effect ion guiding, and perform fragmentation and mass analysis. Despite its small dimensions, the collision cell efficiently fragments precursor ions and yields product ion spectra that are very similar to those recorded using conventional instruments. The miniature triple quadrupole has been used to detect thiabendazole, a common pesticide, in apples at a level of 10 ng/g.

2.
Rapid Commun Mass Spectrom ; 25(21): 3281-8, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22006391

RESUMEN

A miniature mass spectrometer capable of detecting analytes eluting from a high-performance liquid chromatography (HPLC) system is described and demonstrated for the first time. The entire instrument, including all pumps and the computer, is contained within a single enclosure that may be conveniently accommodated at the base of the HPLC stack. The microspray ion source, vacuum interface, ion guide, and quadrupole ion filter are all microengineered. These components are fabricated in batches using microelectromechanical systems (MEMS) techniques and considered to be consumables. When coupled to a standard HPLC system using an integrated passive split, the limit of detection for reserpine while scanning the full mass range is 5 ng on-column (1 pg of which is passed to the microspray). The mass range is m/z 100-800, and each spectrum is typically acquired at a rate of 1 scan per second.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas/instrumentación , Sistemas Microelectromecánicos/instrumentación , Miniaturización/instrumentación , Espectrometría de Masas/métodos , Modelos Químicos , Reserpina/análisis , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA