Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
N Engl J Med ; 391(7): 619-626, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39141854

RESUMEN

The durability of communication with the use of brain-computer interfaces in persons with progressive neurodegenerative disease has not been extensively examined. We report on 7 years of independent at-home use of an implanted brain-computer interface for communication by a person with advanced amyotrophic lateral sclerosis (ALS), the inception of which was reported in 2016. The frequency of at-home use increased over time to compensate for gradual loss of control of an eye-gaze-tracking device, followed by a progressive decrease in use starting 6 years after implantation. At-home use ended when control of the brain-computer interface became unreliable. No signs of technical malfunction were found. Instead, the amplitude of neural signals declined, and computed tomographic imaging revealed progressive atrophy, which suggested that ALS-related neurodegeneration ultimately rendered the brain-computer interface ineffective after years of successful use, although alternative explanations are plausible. (Funded by the National Institute on Deafness and Other Communication Disorders and others; ClinicalTrials.gov number, NCT02224469.).


Asunto(s)
Esclerosis Amiotrófica Lateral , Atrofia , Interfaces Cerebro-Computador , Femenino , Humanos , Persona de Mediana Edad , Esclerosis Amiotrófica Lateral/complicaciones , Esclerosis Amiotrófica Lateral/diagnóstico por imagen , Esclerosis Amiotrófica Lateral/rehabilitación , Atrofia/diagnóstico por imagen , Atrofia/etiología , Atrofia/prevención & control , Encéfalo/diagnóstico por imagen , Equipos de Comunicación para Personas con Discapacidad , Factores de Tiempo , Insuficiencia del Tratamiento , Electrodos Implantados
2.
Epilepsy Behav ; 158: 109908, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38964183

RESUMEN

OBJECTIVE: Evaluate the performance of a custom application developed for tonic-clonic seizure (TCS) monitoring on a consumer-wearable (Apple Watch) device. METHODS: Participants with a history of convulsive epileptic seizures were recruited for either Epilepsy Monitoring Unit (EMU) or ambulatory (AMB) monitoring; participants without epilepsy (normal controls [NC]) were also enrolled in the AMB group. Both EMU and AMB participants wore an Apple Watch with a research app that continuously recorded accelerometer and photoplethysmography (PPG) signals, and ran a fixed-and-frozen tonic-clonic seizure detection algorithm during the testing period. This algorithm had been previously developed and validated using a separate training dataset. All EMU convulsive events were validated by video-electroencephalography (video-EEG); AMB events were validated by caregiver reporting and follow-ups. Device performance was characterized and compared to prior monitoring devices through sensitivity, false alarm rate (FAR; false-alarms per 24 h), precision, and detection delay (latency). RESULTS: The EMU group had 85 participants (4,279 h, 19 TCS from 15 participants) enrolled across four EMUs; the AMB group had 21 participants (13 outpatient, 8 NC, 6,735 h, 10 TCS from 3 participants). All but one AMB participant completed the study. Device performance in the EMU group included a sensitivity of 100 % [95 % confidence interval (CI) 79-100 %]; an FAR of 0.05 [0.02, 0.08] per 24 h; a precision of 68 % [48 %, 83 %]; and a latency of 32.07 s [standard deviation (std) 10.22 s]. The AMB group had a sensitivity of 100 % [66-100 %]; an FAR of 0.13 [0.08, 0.24] per 24 h; a precision of 22 % [11 %, 37 %]; and a latency of 37.38 s [13.24 s]. Notably, a single AMB participant was responsible for 8 of 31 false alarms. The AMB FAR excluding this participant was 0.10 [0.07, 0.14] per 24 h. DISCUSSION: This study demonstrates the practicability of TCS monitoring on a popular consumer wearable (Apple Watch) in daily use for people with epilepsy. The monitoring app had a high sensitivity and a substantially lower FAR than previously reported in both EMU and AMB environments.

3.
J Neural Eng ; 21(4)2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38925110

RESUMEN

Objective.Speech brain-computer interfaces (BCIs) have the potential to augment communication in individuals with impaired speech due to muscle weakness, for example in amyotrophic lateral sclerosis (ALS) and other neurological disorders. However, to achieve long-term, reliable use of a speech BCI, it is essential for speech-related neural signal changes to be stable over long periods of time. Here we study, for the first time, the stability of speech-related electrocorticographic (ECoG) signals recorded from a chronically implanted ECoG BCI over a 12 month period.Approach.ECoG signals were recorded by an ECoG array implanted over the ventral sensorimotor cortex in a clinical trial participant with ALS. Because ECoG-based speech decoding has most often relied on broadband high gamma (HG) signal changes relative to baseline (non-speech) conditions, we studied longitudinal changes of HG band power at baseline and during speech, and we compared these with residual high frequency noise levels at baseline. Stability was further assessed by longitudinal measurements of signal-to-noise ratio, activation ratio, and peak speech-related HG response magnitude (HG response peaks). Lastly, we analyzed the stability of the event-related HG power changes (HG responses) for individual syllables at each electrode.Main Results.We found that speech-related ECoG signal responses were stable over a range of syllables activating different articulators for the first year after implantation.Significance.Together, our results indicate that ECoG can be a stable recording modality for long-term speech BCI systems for those living with severe paralysis.Clinical Trial Information.ClinicalTrials.gov, registration number NCT03567213.


Asunto(s)
Esclerosis Amiotrófica Lateral , Interfaces Cerebro-Computador , Electrocorticografía , Habla , Humanos , Esclerosis Amiotrófica Lateral/fisiopatología , Estudios Longitudinales , Electrocorticografía/métodos , Habla/fisiología , Masculino , Ritmo Gamma/fisiología , Persona de Mediana Edad , Femenino , Electrodos Implantados
4.
Clin Neurophysiol ; 166: 43-55, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39096821

RESUMEN

OBJECTIVE: While evoked potentials elicited by single pulse electrical stimulation (SPES) may assist seizure onset zone (SOZ) localization during intracranial EEG (iEEG) monitoring, induced high frequency activity has also shown promising utility. We aimed to predict SOZ sites using induced cortico-cortical spectral responses (CCSRs) as an index of excitability within epileptogenic networks. METHODS: SPES was conducted in 27 epilepsy patients undergoing iEEG monitoring and CCSRs were quantified by significant early (10-200 ms) increases in power from 10 to 250 Hz. Using response power as CCSR network connection strengths, graph centrality measures (metrics quantifying each site's influence within the network) were used to predict whether sites were within the SOZ. RESULTS: Across patients with successful surgical outcomes, greater CCSR centrality predicted SOZ sites and SOZ sites targeted for surgical treatment with median AUCs of 0.85 and 0.91, respectively. We found that the alignment between predicted and targeted SOZ sites predicted surgical outcome with an AUC of 0.79. CONCLUSIONS: These findings indicate that network analysis of CCSRs can be used to identify increased excitability of SOZ sites and discriminate important surgical targets within the SOZ. SIGNIFICANCE: CCSRs may supplement traditional passive iEEG monitoring in seizure localization, potentially reducing the need for recording numerous seizures.

5.
Sci Rep ; 14(1): 9617, 2024 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671062

RESUMEN

Brain-computer interfaces (BCIs) that reconstruct and synthesize speech using brain activity recorded with intracranial electrodes may pave the way toward novel communication interfaces for people who have lost their ability to speak, or who are at high risk of losing this ability, due to neurological disorders. Here, we report online synthesis of intelligible words using a chronically implanted brain-computer interface (BCI) in a man with impaired articulation due to ALS, participating in a clinical trial (ClinicalTrials.gov, NCT03567213) exploring different strategies for BCI communication. The 3-stage approach reported here relies on recurrent neural networks to identify, decode and synthesize speech from electrocorticographic (ECoG) signals acquired across motor, premotor and somatosensory cortices. We demonstrate a reliable BCI that synthesizes commands freely chosen and spoken by the participant from a vocabulary of 6 keywords previously used for decoding commands to control a communication board. Evaluation of the intelligibility of the synthesized speech indicates that 80% of the words can be correctly recognized by human listeners. Our results show that a speech-impaired individual with ALS can use a chronically implanted BCI to reliably produce synthesized words while preserving the participant's voice profile, and provide further evidence for the stability of ECoG for speech-based BCIs.


Asunto(s)
Esclerosis Amiotrófica Lateral , Interfaces Cerebro-Computador , Habla , Humanos , Esclerosis Amiotrófica Lateral/fisiopatología , Esclerosis Amiotrófica Lateral/terapia , Masculino , Habla/fisiología , Persona de Mediana Edad , Electrodos Implantados , Electrocorticografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA