Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Nanomedicine ; 40: 102476, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34743019

RESUMEN

We report the design and adaptation of iron/iron oxide nanoparticle-based optical nanobiosensors for enzymes or cytokine/chemokines that are established biomarkers of lung diseases. These biomarkers comprise ADAM33, granzyme B, MMP-8, neutrophil elastase, arginase, chemokine (C-C motif) ligand 20 and interleukin-6. The synthesis of nanobiosensors for these seven biomarkers, their calibration with commercially available enzymes and cytokines/chemokines, as well as their validation using bronchoalveolar lavage (BAL) obtained from a mouse model of TLR3-mediated inflammation are discussed here. Exhaled Breath Condensate (EBC) is a minimally invasive approach for sampling airway fluid in the diagnosis and management of various lung diseases in humans (e.g., asthma, COPD and viral infections). We report the proof-of-concept of using human EBC in conjunction with nanobiosensors for diagnosis/monitoring airway inflammation. These findings suggest that, with nanosensor technology, human EBC can be utilized as a liquid biopsy to monitor inflammation/remodeling in lung disease.


Asunto(s)
Asma , Enfermedades Pulmonares , Animales , Biomarcadores , Pruebas Respiratorias , Inflamación/diagnóstico , Ratones
2.
Nanomedicine ; 14(6): 1823-1832, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29782949

RESUMEN

Numerous proteases, such as matrix metalloproteinases (MMPs), cathepsins (CTS), and urokinase plasminogen activator (UpA), are dysfunctional (that is, over- or under-expressed) in solid tumors, when compared to healthy human subjects. This offers the opportunity to detect early tumors by liquid biopsies. This approach is of particular advantage for the early detection of pancreatic cancer, which is a "silent killer". We have developed fluorescence nanobiosensors for ultrasensitive (sub-femtomolar) arginase and protease detection, consisting of water-dispersible Fe/Fe3O4 core/shell nanoparticles and two tethered fluorescent dyes: TCPP (Tetrakis(4-carboxyphenyl)porphyrin) and cyanine 5.5. Upon posttranslational modification or enzymatic cleavage, the fluorescence of TCPP increases, which enables the detection of proteases at sub-femtomolar activities utilizing conventional plate readers. We have identified an enzymatic signature for the detection of pancreatic adenocarcinomas in serum, consisting of arginase, matrix metalloproteinase-1, -3, and - 9, cathepsin-B and -E, urokinase plasminogen activator, and neutrophil elastase, which is a potential game-changer.


Asunto(s)
Técnicas Biosensibles , Carcinoma Ductal Pancreático/diagnóstico , Detección Precoz del Cáncer/métodos , Colorantes Fluorescentes/química , Nanopartículas/química , Neoplasias Pancreáticas/diagnóstico , Estudios de Casos y Controles , Femenino , Humanos , Biopsia Líquida , Masculino
3.
Anal Chem ; 88(20): 9920-9925, 2016 10 18.
Artículo en Inglés | MEDLINE | ID: mdl-27626461

RESUMEN

A microfluidic device is reported that employs an out-of-plane optical fiber bridge to generate two excitation and two detection spots in a microfluidic channel using only one excitation source and one detector. This fiber optic bridge was integrated into a single cell analysis device to detect an intact cell just prior to lysis and the injected lysate 2, 5, 10, or 15 mm downstream of the injection point. Using this setup the absolute migration times for analytes from cells stochastically entering the lysis intersection could be determined for the first time in an automated fashion. This allowed the evaluation of several separation parameters, including analyte band velocity, migration time drift, diffusion coefficient, injection plug length, separation efficiency (N), and plate height (H), which previously could only be estimated. To demonstrate the utility of this system, a peptide substrate for protein kinase B (PKB) was designed, synthesized, and loaded into T-lymphocytes in order to measure PKB activity in individual cells. The optical fiber bridge is easy to implement, inexpensive, and flexible in terms of changing the distances between the two detection points.


Asunto(s)
Tecnología de Fibra Óptica/instrumentación , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Análisis de la Célula Individual/métodos , Humanos , Células Jurkat/metabolismo , Fibras Ópticas , Péptidos/análisis , Péptidos/metabolismo , Fosfopéptidos/análisis , Fosforilación , Proteínas Proto-Oncogénicas c-akt/análisis , Proteínas Proto-Oncogénicas c-akt/metabolismo , Análisis de la Célula Individual/instrumentación
4.
Electrophoresis ; 37(10): 1337-44, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26887846

RESUMEN

The ability to accurately control fluid transport in microfluidic devices is key for developing high-throughput methods for single cell analysis. Making small, reproducible changes to flow rates, however, to optimize lysis and injection using pumps external to the microfluidic device are challenging and time-consuming. To improve the throughput and increase the number of cells analyzed, we have integrated previously reported micropumps into a microfluidic device that can increase the cell analysis rate to ∼1000 cells/h and operate for over an hour continuously. In order to increase the flow rates sufficiently to handle cells at a higher throughput, three sets of pumps were multiplexed. These pumps are simple, low-cost, durable, easy to fabricate, and biocompatible. They provide precise control of the flow rate up to 9.2 nL/s. These devices were used to automatically transport, lyse, and electrophoretically separate T-Lymphocyte cells loaded with Oregon green and 6-carboxyfluorescein. Peak overlap statistics predicted the number of fully resolved single-cell electropherograms seen. In addition, there was no change in the average fluorescent dye peak areas indicating that the cells remained intact and the dyes did not leak out of the cells over the 1 h analysis time. The cell lysate peak area distribution followed that expected of an asynchronous steady-state population of immortalized cells.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento/métodos , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Análisis de la Célula Individual , Linfocitos T , Ácidos Carboxílicos , Separación Celular , Electroforesis , Fluoresceínas , Colorantes Fluorescentes , Humanos
6.
Anal Chem ; 85(21): 10188-95, 2013 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-24010877

RESUMEN

A considerable amount of attention has been focused on the analysis of single cells in an effort to better understand cell heterogeneity in cancer and neurodegenerative diseases. Although microfluidic devices have several advantages for single cell analysis, few papers have actually demonstrated the ability of these devices to monitor chemical changes in perturbed biological systems. In this paper, a new microfluidic channel manifold is described that integrates cell transport, lysis, injection, electrophoretic separation, and fluorescence detection into a single device, making it possible to analyze individual cells at a rate of 10 cells/min in an automated fashion. The system was employed to measure nitric oxide (NO) production in single T-lymphocytes (Jurkat cells) using a fluorescent marker, 4-amino-5-methylamino-2',7'-difluorofluorescein diacetate (DAF-FM DA). The cells were also labeled with 6-carboxyfluorescein diacetate (6-CFDA) as an internal standard. The NO production by control cells was compared to that of cells stimulated using lipopolysaccharide (LPS), which is known to cause the expression of inducible nitric oxide synthase (iNOS) in immune-type cells. Statistical analysis of the resulting electropherograms from a population of cells indicated a 2-fold increase in NO production in the induced cells. These results compare nicely to a recently published bulk cell analysis of NO.


Asunto(s)
Microfluídica/instrumentación , Óxido Nítrico/biosíntesis , Análisis de la Célula Individual , Linfocitos T/metabolismo , Humanos , Células Jurkat , Estándares de Referencia
7.
Electrophoresis ; 34(7): 1123-30, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23348683

RESUMEN

This work describes efficient manipulation of bacteriophage virus particles using a nanostructured DEP device. The nonuniform electric field for DEP is created by utilizing a nanoelectrode array (NEA) made of vertically aligned carbon nanofibers versus a macroscopic indium tin oxide electrode in a "points-and-lid" configuration integrated in a microfluidic channel. The capture of the virus particles has been systematically investigated versus the flow velocity, sinusoidal AC frequency, peak-to-peak voltage, and virus concentration. The DEP capture at all conditions is reversible and the captured virus particles are released immediately when the voltage is turned off. At the low virus concentration (8.9 × 10(4) pfu/mL), the DEP capture efficiency up to 60% can be obtained. The virus particles are individually captured at isolated nanoelectrode tips and accumulate linearly with time. Due to the comparable size, it is more effective to capture virus particles than larger bacterial cells with such NEA-based DEP devices. This technique can be potentially utilized as a fast sample preparation module in a microfluidic chip to capture, separate, and concentrate viruses and other biological particles in small volumes of dilute solutions in a portable detection system for field applications.


Asunto(s)
Bacteriófago T4/aislamiento & purificación , Carbono/química , Electroforesis/instrumentación , Electroforesis/métodos , Nanofibras/química , Nanotecnología/instrumentación , Nanotecnología/métodos , Bacteriófago T4/química , Diseño de Equipo , Análisis por Micromatrices/instrumentación , Análisis por Micromatrices/métodos , Microelectrodos , Tamaño de la Partícula
8.
bioRxiv ; 2023 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-37461554

RESUMEN

Insect humoral immune responses are regulated in part by protease cascades, whose components circulate as zymogens in the hemolymph. In mosquitoes, these cascades consist of clip domain serine proteases (cSPs) and/or their non-catalytic homologs (cSPHs), which form a complex network, whose molecular make-up is not fully understood. Using a systems biology approach, based on a co-expression network of gene family members that function in melanization and co-immunoprecipitation using the serine protease inhibitor (SRPN)2, a key negative regulator of the melanization response in mosquitoes, we identify the cSP CLIPB4 from the African malaria mosquito Anopheles gambiae as a central node in this protease network. CLIPB4 is tightly co-expressed with SRPN2 and forms protein complexes with SRPN2 in the hemolymph of immune-challenged female mosquitoes. Genetic and biochemical approaches validate our network analysis and show that CLIPB4 is required for melanization and antibacterial immunity, acting as a prophenoloxidase (proPO)-activating protease, which is inhibited by SRPN2. In addition, we provide novel insight into the structural organization of the cSP network in An. gambiae, by demonstrating that CLIPB4 is able to activate proCLIPB8, a cSP upstream of the proPO-activating protease CLIPB9. These data provide the first evidence that, in mosquitoes, cSPs provide branching points in immune protease networks and deliver positive reinforcement in proPO activation cascades.

9.
J Innate Immun ; 15(1): 680-696, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37703846

RESUMEN

Insect humoral immune responses are regulated in part by protease cascades, whose components circulate as zymogens in the hemolymph. In mosquitoes, these cascades consist of clip-domain serine proteases (cSPs) and/or their non-catalytic homologs, which form a complex network, whose molecular make-up is not fully understood. Using a systems biology approach, based on a co-expression network of gene family members that function in melanization and co-immunoprecipitation using the serine protease inhibitor (SRPN)2, a key negative regulator of the melanization response in mosquitoes, we identify the cSP CLIPB4 from the African malaria mosquito Anopheles gambiae as a central node in this protease network. CLIPB4 is tightly co-expressed with SRPN2 and forms protein complexes with SRPN2 in the hemolymph of immune-challenged female mosquitoes. Genetic and biochemical approaches validate our network analysis and show that CLIPB4 is required for melanization and antibacterial immunity, acting as a prophenoloxidase (proPO)-activating protease, which is inhibited by SRPN2. In addition, we provide novel insight into the structural organization of the cSP network in An. gambiae, by demonstrating that CLIPB4 is able to activate proCLIPB8, a cSP upstream of the proPO-activating protease CLIPB9. These data provide the first evidence that, in mosquitoes, cSPs provide branching points in immune protease networks and deliver positive reinforcement in proPO activation cascades.


Asunto(s)
Anopheles , Serpinas , Animales , Femenino , Inmunidad Humoral , Serina Endopeptidasas/genética , Serina Endopeptidasas/metabolismo , Serina Proteasas/genética , Serpinas/genética , Serpinas/metabolismo , Proteínas de Insectos/genética , Proteínas de Insectos/metabolismo
11.
Electrophoresis ; 32(17): 2358-65, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21823128

RESUMEN

This paper reports capture and detection of pathogenic bacteria based on AC dielectrophoresis (DEP) and electrochemical impedance spectroscopy (EIS) employing an embedded vertically aligned carbon nanofiber (VACNF) nanoelectrode array (NEA) versus a macroscopic indium-tin-oxide (ITO) transparent electrode in "points-and-lid" configuration. The nano-DEP device was fabricated using photolithography processes to define an exposed active region on a randomly distributed NEA and a microfluidic channel on ITO to guide the flow of labeled Escherichia coli cells, respectively, and then bond them into a fluidic chip. A high-frequency (100 kHz) AC field was applied to generate positive DEP at the tips of exposed CNFs. Enhanced electric field gradient was achieved due to reduction in electrode size down to nanometer scale which helped to overcome the large hydrodynamic drag force experienced by E. coli cells at high flow velocities (up to 1.6 mm/s). This DEP device was able to effectively capture a significant number of E. coli cells. Significant decrease in the absolute impedance at the NEA was observed in EIS experiments. The results obtained in this study suggest the possibility of integration of a fully functional electronic device for rapid, reversible and label-free capture and detection of pathogenic bacteria.


Asunto(s)
Electroforesis/instrumentación , Electroforesis/métodos , Escherichia coli/aislamiento & purificación , Nanotecnología/instrumentación , Carbono/química , Espectroscopía Dieléctrica , Escherichia coli/citología , Nanofibras/química
12.
Anal Bioanal Chem ; 399(1): 519-24, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21058011

RESUMEN

Catechol estrogen-derived DNA adducts are formed as a result of the reaction of catechol estrogen metabolites (e.g., catechol estrogen quinones) with DNA to form depurinating adducts. Developing a new methodology for the detection of various DNA adducts is essential for medical diagnostics, and to this end, we demonstrate the applicability of on-chip capillary electrophoresis with an integrated electrochemical system for the separation and amperometric detection of various catechol estrogen-derived DNA adducts. A hybrid PDMS/glass microchip with in-channel amperometric detection interfaced with in situ palladium decoupler is utilized and presented. The influence of buffer additives along with the effect of the separation voltage on the resolving power of the microchip is discussed. Calibration plots were constructed in the range 0.4-10 µM with r(2) ≥ 0.999, and detection limits in the attomole range are reported. These results suggest that on-chip analysis is applicable for analyzing various DNA adducts as potential biomarkers for future medical diagnostics.


Asunto(s)
Aductos de ADN/aislamiento & purificación , Electroforesis Capilar/métodos , Estrógenos de Catecol/aislamiento & purificación , Técnicas Analíticas Microfluídicas/métodos , Aductos de ADN/química , Electroquímica , Electroforesis Capilar/instrumentación , Estrógenos de Catecol/química , Humanos , Técnicas Analíticas Microfluídicas/instrumentación
13.
Anal Bioanal Chem ; 397(5): 1821-9, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20425107

RESUMEN

We report the use of paper-based microfluidic devices fabricated from a novel polymer blend for the monitoring of urinary ketones, glucose, and salivary nitrite. Paper-based devices were fabricated via photolithography in less than 3 min and were immediately ready for use for these diagnostically relevant assays. Patterned channels on filter paper as small as 90 microm wide with barriers as narrow as 250 microm could be reliably patterned to permit and block fluid wicking, respectively. Colorimetric assays for ketones and nitrite were adapted from the dipstick format to this paper microfluidic chip for the quantification of acetoacetate in artificial urine, as well as nitrite in artificial saliva. Glucose assays were based on those previously demonstrated (Martinez et al., Angew Chem Int Ed 8:1318-1320, 1; Martinez et al., Anal Chem 10:3699-3707, 2; Martinez et al., Proc Nat Acad Sci USA 50:19606-19611, 3; Lu et al., Electrophoresis 9:1497-1500, 4; Abe et al., Anal Chem 18:6928-6934, 5). Reagents were spotted on the detection pad of the paper device and allowed to dry prior to spotting of samples. The ketone test was a two-step reaction requiring a derivitization step between the sample spotting pad and the detection pad, thus for the first time, confirming the ability of these paper devices to perform online multi-step chemical reactions. Following the spotting of the reagents and sample solution onto the paper device and subsequent drying, color images of the paper chips were recorded using a flatbed scanner, and images were converted to CMYK format in Adobe Photoshop CS4 where the intensity of the color change was quantified using the same software. The limit of detection (LOD) for acetoacetate in artificial urine was 0.5 mM, while the LOD for salivary nitrite was 5 microM, placing both of these analytes within the clinically relevant range for these assays. Calibration curves for urinary ketone (5 to 16 mM) and salivary nitrite (5 to 2,000 microM) were generated. The time of device fabrication to the time of test results was about 25 min.


Asunto(s)
Glucosa/análisis , Cetonas/orina , Técnicas Analíticas Microfluídicas/métodos , Nitritos/análisis , Saliva/química , Humanos , Técnicas Analíticas Microfluídicas/instrumentación
14.
Anal Methods ; 12(38): 4665-4673, 2020 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-32909562

RESUMEN

Chronic neuroinflammation has long been considered to be a central factor in accelerating the progression of neurodegenerative diseases such as Alzheimer's diseases, Parkinson's disease and chronic traumatic encephalopathy. Under pathological conditions microglia produce inflammatory signaling molecules, such as nitric oxide (NO), that can damage DNA and proteins and ultimately induce neuronal apoptosis. One strategy for treating neurodegenerative diseases is to specifically target NO production through inhibition of inducible nitric oxide synthase (iNOS). However, accurately measuring changes in microglial NO production in response to potential therapeutics is challenging due to NO's short half-life and microglial heterogeneity. In this paper we report the application of a microfluidic device for the high-throughput measurement of intracellular NO in SIM-A9 microglial cells. NO production was measured in response to treatment with lipopolysaccharides (LPS) and interferon gamma (IFN-γ) with and without a potent iNOS inhibitor (1400 W dihydrochloride). Cells were labeled with a fluorogenic NO probe, 4-amino-5-methylamino-2',7'-difluorofluoescein diacetate (DAF-FM DA), and 6-carboxyfluorescein diacetate (6-CFDA) as an internal standard. Separation and quantitation of intracellular NO was achieved using microchip electrophoresis and laser induced fluorescence detection (LIF). Statistical analysis suggests that the populations fit a lognormal distribution and are better represented by their geometric mean values. Comparison of the geometric means indicated a 1.6-fold increase in NO production between untreated and stimulated cells and a decrease by a factor of approximately 0.5 comparing stimulated and inhibited cells. Additionally, we report experimental data demonstrating the improvement in the sensitivity of our integrated optical fiber-based detection system through the use of refractive index matching gel.


Asunto(s)
Microglía , Óxido Nítrico , Microfluídica , FN-kappa B , Análisis de la Célula Individual
15.
Lab Chip ; 9(14): 2076-84, 2009 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-19568678

RESUMEN

The construction of microfluidic devices from siloxane-based polymers is widely reported in the current literature. While the use of these materials is primarily due to their rapid and facile fabrication, low cost and robustness, they also have the ability to function as smart materials. This feature, however, has not been commonly exploited in conjunction with their fluid-handling capabilities. Siloxanes are considered smart materials because their shapes can be modified in the presence of an electric field. The energy in the electric field can be transduced into mechanical energy and directly coupled with a microfabricated channel network in order to affect or initiate the movement of fluids. Here, we present a novel microfluidic device into which an electroactive polymer (EAP) actuation unit is integrated. The EAP actuation unit features a microfluidic channel placed above a patterned electrode. The patterned electrode is insulated from the channel by an EAP layer that is composed of PDMS. When a potential is applied across the EAP layer, it changes shape, which also changes the volume of the microfluidic channel above it. With this proof-of-concept device we demonstrated the ability to inject plugs of sample on a standard electrophoresis cross chip solely by changing the magnitude of the electric field between the channel and the electrode. Using an EAP actuation unit, the size of the injection plugs can be varied as a function of the electric field, the active area of the EAP actuation unit and the softness of the EAP.

16.
Anal Chem ; 81(21): 8942-8, 2009 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-19817486

RESUMEN

Sample introduction is a crucial, yet often overlooked step in chemical analysis. Its importance is clearly portrayed in the case of electrokinetic injection for electrophoretic separations, where sampling bias favors the introduction of the fastest moving analytes in a mixture. To this end, a poly(dimethylsiloxane) (PDMS)-based microfluidic device that incorporates miniaturized and fully integrated dielectric elastomer actuators (IDEAs) in order to perform sample injection for electrophoresis is reported. These electromechanical actuators produce hydrodynamic fluid pulses within the channel network without the need for any modifications to the channel design and without the use of large, off-chip equipment. Separations of Fluorescein thiocarbamyl-labeled amino acids reveal that IDEA-derived injections have a more stable chemical composition than electrokinetic injections, with peak area relative standard deviations (RSDs) less than 1.1% over 30 injections at six different volumes. Moreover, the efficiency and resolution of separations with IDEA-derived injections are not significantly different from electrokinetic injections under similar separation conditions. The reproducibility of peak heights and peak areas over the course of 64 consecutive injections reveal that the actuation mechanism is very stable with peak area RSDs less than 1.8%. These results, coupled with facile fabrication and operation of IDEA devices, suggest that widespread adaptation of this technology could be very advantageous for many types of miniaturized analysis systems.

17.
Anal Chem ; 81(24): 10089-96, 2009 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-19928808

RESUMEN

Single-molecule microscopic methods were used to probe the uptake, mobility, and entrapment of dye molecules in cured poly(dimethylsiloxane) (PDMS) films as a function of oligomer extraction. The results are relevant to the use of PDMS in microfluidic separations, pervaporation, solid-phase microextraction, and nanofiltration. PDMS films were prepared by spin-casting dilute solutions of Sylgard 184 onto glass coverslips, yielding approximately 1.4 microm thick films after curing. Residual oligomers were subsequently extracted from the films by "spin extraction". In this procedure, 200 microL aliquots of isopropyl alcohol were repeatedly dropped onto the film surface and spun off at 2000 rpm. Samples extracted 5, 10, 20, and 40 times were investigated. Dye molecules were loaded into these films by spin-casting nanomolar dye solutions onto the films. Both neutral perylene diimide (N,N'-bis(butoxypropyl)perylene-3,4,9,10-tetracarboxylic diimide) and cationic rhodamine 6G (R6G) dyes were employed. The films were imaged by confocal fluorescence microscopy. The images obtained depict nonzero populations of fixed and mobile molecules in all films. Cross-correlation methods were used to quantitatively determine the population of fixed molecules in a given region, while a Bayesian burst analysis was used to obtain the total population of molecules. The results show that the total amount of dye loaded increases with increased oligomer extraction, while the relative populations of fixed and mobile molecules decrease and increase, respectively. Bulk R6G data also show greater dye loading with increased oligomer extraction.


Asunto(s)
Dimetilpolisiloxanos/química , Membranas Artificiales , Perileno/química , Rodaminas/química , Microextracción en Fase Sólida , Filtración , Microfluídica , Perileno/análogos & derivados , Propiedades de Superficie
19.
Electrophoresis ; 30(18): 3160-7, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19722198

RESUMEN

We have developed a new method for analyte preconcentration on a microfluidic device using a porous membrane fabricated via sol-gel chemistry. These porous membranes were fabricated within the channels of glass microfluidic devices exploiting laminar flow to bring an alcoholic sol-gel precursor (titanium isopropoxide in 2-propanol) into contact with an alcohol-water solution at a channel cross intersection. These two streams reacted at the fluidic interface to form a porous titania membrane. The thickness of the membrane could be altered by changing the [H2O]. Analyte concentration was accomplished by applying a voltage across the titania membrane. The level of analyte enrichment was monitored, and enrichment factors of above 4000 in 400 s were obtained for 2,7-dichlorofluorescein.


Asunto(s)
Electroforesis/instrumentación , Electroforesis/métodos , Membranas Artificiales , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Titanio/química , Fluoresceínas/aislamiento & purificación , Iones/química , Microscopía Fluorescente , Transición de Fase , Fosfatos/química , Porosidad , Reproducibilidad de los Resultados
20.
Methods Enzymol ; 628: 223-241, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31668231

RESUMEN

Here we describe in detail the design, fabrication and operation of our automated high-throughput single cell microchip electrophoresis device with laser induced fluorescence detection. Our device features on-board integrated peristaltic pumps that generate flow directly within the microfluidic channels. Additionally, we have incorporated an optical fiber bridge that enables simultaneous fluorescence detection at two points of interest within the device without the need for additional optical components or detectors. The second detection spot is used to detect the intact cell immediately prior to lysis giving a signal at t=0s for each single-cell electropherogram. We can also use this signal to measure the absolute migration time of the separated analytes to confidently determine the identity of each peak. Finally, we demonstrate the application of our device for the measurement of intracellular nitric oxide (NO) levels in T-lymphocytes. Changes in NO levels within cells is associated with a number of chronic diseases including neurodegenerative, cardiovascular and cancers. We show that our system is capable of measuring NO levels under the following conditions: native, lipopolysaccharide stimulation, and inhibition of inducible nitric oxide synthase. It is our hope that the information and procedures described in this chapter may enable others to use or adapt our system for other analyses at the single cell level.


Asunto(s)
Electroforesis por Microchip/instrumentación , Análisis de la Célula Individual/instrumentación , Pruebas de Enzimas/instrumentación , Diseño de Equipo , Humanos , Células Jurkat , Óxido Nítrico/análisis , Fibras Ópticas , Linfocitos T/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA