Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 142(15): 1497-1499, 2020 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-33044863
2.
JAMA ; 316(10): 1083-92, 2016 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-27623462

RESUMEN

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). CONCLUSIONS AND RELEVANCE: Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality.


Asunto(s)
Endocarditis Bacteriana/epidemiología , Endocarditis/etiología , Mortalidad Hospitalaria/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Edad , Anciano , Endocarditis Bacteriana/etiología , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca , Humanos , Masculino , Oportunidad Relativa , Sistema de Registros , Factores de Riesgo , Factores Sexuales , Infecciones Estafilocócicas/epidemiología , Infecciones Estafilocócicas/etiología , Staphylococcus aureus , Resultado del Tratamiento
3.
Heart Lung Circ ; 21(3): 169-73, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22071201

RESUMEN

BACKGROUND: Minimally invasive surgery (MIS) for aortic valve replacement (AVR) is going to increase with different techniques described so far. We hereby report the results of AVR through a right minithoracotomy (RM) compared to a median sternotomy (MS). MATERIALS AND METHODS: One hundred patients operated for isolated AVR by the same surgeon (chief of the department) were enrolled and allocated to: MS (group A, 50 patients, 26 females, mean age 69.9 ± 12.4 years). RM (group B, 50 patients, 27 females, mean age 71.6 ± 11.2 years). Mean logistic Euroscores were, respectively, 6.5 ± 4.0 and 8.0 ± 5.9 (p=ns). RESULTS: Mean duration of cardiopulmonary by-pass (CPB) was 62.8 ± 18.3 min in group A and 101.4 ± 35.2 min in group B (p<0.05); cross-clamp was 44.8 ± 13.4 min in group A and 74.6 ± 26.7 min in group B (p<0.05). Thirty-day mortality was 2 (4%) in group A and 0 in group B (p=ns). ICU stay and hospital stay did not significantly differ amongst two groups. The incidence of bleeding was lower in group B, showing a slight reduction of blood transfusions and re-explorations (p=ns). CONCLUSIONS: Our experience shows that RM offers a good 30-day survival and a lower incidence of mediastinitis or osteomyelitis. The risk of insufficient vision or sudden complications is safely managed by enlarging the surgical incision through a transverse sternotomy.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Esternotomía/métodos , Toracotomía/métodos , Anciano , Válvula Aórtica/patología , Puente Cardiopulmonar , Distribución de Chi-Cuadrado , Femenino , Indicadores de Salud , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Esternotomía/instrumentación , Toracotomía/instrumentación , Factores de Tiempo
4.
J Cardiovasc Med (Hagerstown) ; 23(6): 406-413, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35645032

RESUMEN

AIMS: To compare early and late mortality of acute isolated tricuspid valve infective endocarditis (TVIE) treated with valve repair or replacement. METHODS: Patients who were surgically treated for TVIE from 1983 to 2018 were retrieved from the Italian Registry for Surgical Treatment of Valve and Prosthesis Infective Endocarditis. All the patients were followed up by means of phone interview or calling patient referral physicians or cardiologists. Kaplan-Meier method was used to assess late survival and survival free from TVIE recurrence with log-rank test for univariate comparison. The primary end points were early mortality (30 days after surgery) and long-term survival free from TVIE recurrence. RESULTS: A total of 4084 patients were included in the registry. Among them, 149 patients were included in the study. Overall, 77 (51.7%) underwent TV repair and 72 (48.3%) TV replacement. Early mortality was 9% (13 patients). Expected early mortality according to EndoSCORE was 12%. The TV repair showed lower mortality and major complication rate (7% and 16%), compared with TV replacement (11% and 25%), but statistical significance was not reached. Median follow-up was 19.1 years (14.3-23.8). Late deaths were 30 and IE recurrences were 5. No difference in cardiac survival free from IE was found between the two groups after 20 years (80 ±â€Š6% Repair Group vs 59 ±â€Š13% Replacement Group, P = 0.3). CONCLUSIONS: Overall results indicate that once surgically addressed, TVIE has a low recurrence rate and excellent survival, apparently regardless of the type of surgery used to treat it.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Endocarditis Bacteriana , Endocarditis , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Endocarditis/cirugía , Endocarditis Bacteriana/cirugía , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
5.
J Extra Corpor Technol ; 43(4): 252-7, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22416606

RESUMEN

Accidental deep hypothermia with body temperature < 28 degrees C induces high mortality rates for neurological and cardiac complications. Although several reports described successful treatment of hypothermic arrest by extracorporeal membrane oxygenation (ECMO), the field of warming in the homeless is almost completely unquestioned although the malnutrition and the co-morbidities are usually believed as relevant risk factors for poor outcome. This article describes the experience of successful warming by ECMO in two homeless victims of unwitnessed cardiac arrest, who survived without neurological or cardiac complications. In conclusion, this is an initial experience and further research is required, although our results are appreciable in this high risk subset of population.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Paro Cardíaco/terapia , Hipotermia/terapia , Personas con Mala Vivienda , Recalentamiento/métodos , Adulto , Alcoholismo , Análisis Químico de la Sangre , Temperatura Corporal , Femenino , Paro Cardíaco/etiología , Paro Cardíaco/fisiopatología , Humanos , Hipotermia/fisiopatología , Masculino , Persona de Mediana Edad
6.
Heart Lung Circ ; 20(8): 543-6, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21530394

RESUMEN

OBJECTIVE: Aortic valve replacement (AVR) is nowadays a safe procedure with low rates of mortality and morbidity, but the necessity for a less invasive approach is going to increase. The use of a stentless prosthesis through right mini-thoracotomy has not yet been described and our experience could be useful for other surgeons. METHODS: From June 2009 until March 2010, seven female patients (mean age 79.9 ± 5.7 years) underwent stentless-AVR for aortic stenosis through a right mini-thoracotomy (RM). The logistic Euroscore was 11.3 ± 6.1, and left ventricular ejection fraction was 60.7 ± 4.5%. In five cases RM was performed through the second intercostal space (ICS); in two cases through the third ICS. The cannulation was in most cases between ascending aorta and femoral vein (5/7). When transverse sternotomy was required (two patients), the right mammary artery was clipped and cut. RESULTS: Extracorporeal circulation time (ECC) was 110 ± 41min and aortic cross clamp was 80 ± 35min. Two patients required transverse sternotomy. The mean bleeding was 484 ± 469ml and the duration of mechanical ventilation was 22.0 ± 12.5h. The ICU stay was 3.3 ± 2.2 days. No in-hospital death was observed. The mean hospital stay was 11.6 ± 5.4 days. CONCLUSION: Right mini-thoracotomy is a safe and applicable approach even in case of AVR using stentless prosthesis. The risk of insufficient surgical exposure or complication may be safely managed, by enlarging the thoracotomy through transverse sternotomy. However, valve implantation could be more difficult than the standard approach and it requires an expert and confident surgeon with a large experience in standard stentless implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Toracotomía/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Masculino
7.
Int J Cardiol ; 292: 62-67, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31130281

RESUMEN

BACKGROUND: To assess early and late mortality in patients with isolated acute tricuspid valve infective endocarditis (TVIE) using data from a multicenter registry. METHODS: From 1983 to 2018, isolated acute TVIE was surgically treated in 157 (3.8%) patients [mean age 47 ±â€¯16 years (range 15-86 years), 25% females]. Of these, 142 (90%) had native tricuspid regurgitation, 7 (5%) native tricuspid valve (TV) steno-regurgitation, and 8 (5%) prosthetic TVIE. Intravenous drug use (IVDU) was recorded in 38% of patients, infection involved cardiac implantable electronic device leads in 21%, and vascular catheters for dialysis in 1%; in the remaining cases, the cause was unknown. The primary endpoint was in-hospital outcome, long-term freedom from recurrence and overall survival. RESULTS: Overall, 77 (49%) patients underwent TV repair, 72 (46%) TV replacement, and 8 (5%) prosthetic TV replacement. Early mortality was 11% (n = 17). Expected early mortality according to EndoSCORE was 12%, with age (odds ratio 1.06) and redo (odds ratio 6.64) as risk factors. Late deaths occurred in 31 patients and TVIE recurrences in 4. Survival rates at 10, 20, and 25 years were 66%, 60%, and 44%, respectively. Risk factors were age [hazard ratio (HR) 1.06], mycotic TVIE (HR 4.2), IVDU (HR 4.90), infected prosthesis replacement (HR 4.4), and presence of cardiac implantable electronic device leads (HR 3.0). No significant difference was found in valve repair vs. replacement and in IVDUs vs. non-IVDUs. CONCLUSIONS: Patients with isolated acute TVIE undergoing surgical treatment show acceptable early and late outcomes. TVIE recurrence was low, and repair of the affected valve does not seem to confer any advantage either at early or long term up to 25 years.


Asunto(s)
Endocarditis/cirugía , Enfermedades de las Válvulas Cardíacas/microbiología , Enfermedades de las Válvulas Cardíacas/cirugía , Válvula Tricúspide/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Tiempo , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/cirugía , Adulto Joven
8.
Int J Cardiol ; 241: 97-102, 2017 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-28390740

RESUMEN

BACKGROUND: The aim of this large retrospective study was to provide a logistic risk model along an additive score to predict early mortality after surgical treatment of patients with heart valve or prosthesis infective endocarditis (IE). METHODS: From 2000 to 2015, 2715 patients with native valve endocarditis (NVE) or prosthesis valve endocarditis (PVE) were operated on in 26 Italian Cardiac Surgery Centers. The relationship between early mortality and covariates was evaluated with logistic mixed effect models. Fixed effects are parameters associated with the entire population or with certain repeatable levels of experimental factors, while random effects are associated with individual experimental units (centers). RESULTS: Early mortality was 11.0% (298/2715); At mixed effect logistic regression the following variables were found associated with early mortality: age class, female gender, LVEF, preoperative shock, COPD, creatinine value above 2mg/dl, presence of abscess, number of treated valve/prosthesis (with respect to one treated valve/prosthesis) and the isolation of Staphylococcus aureus, Fungus spp., Pseudomonas Aeruginosa and other micro-organisms, while Streptococcus spp., Enterococcus spp. and other Staphylococci did not affect early mortality, as well as no micro-organisms isolation. LVEF was found linearly associated with outcomes while non-linear association between mortality and age was tested and the best model was found with a categorization into four classes (AUC=0.851). CONCLUSIONS: The following study provides a logistic risk model to predict early mortality in patients with heart valve or prosthesis infective endocarditis undergoing surgical treatment, called "The EndoSCORE".


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/mortalidad , Endocarditis/diagnóstico , Endocarditis/mortalidad , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/mortalidad , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/tendencias , Femenino , Prótesis Valvulares Cardíacas/microbiología , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Resultado del Tratamiento
9.
J Cardiol ; 63(5): 365-72, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24216316

RESUMEN

BACKGROUND: Stentless prostheses have an interesting hemodynamic performance when compared to stented prostheses and are recommended in cases of small aortic annulus. MATERIALS AND METHODS: From January 1996 to January 2004, 138 patients suffering from aortic disease, underwent aortic valve replacement. • Group A: 93 patients underwent stentless aortic valve implantation [stentless Biocor (Biocor Industria e Pesguisa Ltda, Belo Horizonte, Brazil) and stentless Sorin (Sorin Group, Saluggia, Italy)]. • Group B: 45 patients underwent stented aortic valve implantation (stented Biocor). Patients were assessed by clinical evaluation and echocardiography after a mean follow up of 124.5 ± 58.2 months. RESULTS: There was a significant difference in terms of time of extracorporeal circulation and aortic cross clamp. The actuarial survival at 4, 8, 12, and 15 years is 77%, 50%, 21%, and 18%, respectively. Freedom from reoperation at 4, 8, 12, and 14 years was 92%, 83%, 73%, and 63%, respectively. Freedom from all events, death, and reoperation at 4, 8, 12, and 14 years was 70%, 39%, 13%, and 8%, respectively. There is no statistical difference among the two groups in terms of actuarial survival, freedom from reoperation, and freedom from re-hospitalization for prosthesis-related causes. DISCUSSION: There was a significantly higher incidence of pacemaker implantation in Group A and the causes are not known. The rate of freedom from reoperation is high in both groups for the patients who remained alive. There was no statistical difference about prosthesis dysfunction between the two groups. The higher incidence of death in Group A cannot be explained by causes related to the prosthesis because there is no difference in terms of causes of death. Rates of reoperation did not differ between the two groups. CONCLUSIONS: The results obtained with stentless prostheses are encouraging even in long-term follow-up.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Stents , Anciano , Constricción , Circulación Extracorporea , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación/estadística & datos numéricos , Tasa de Supervivencia , Factores de Tiempo
10.
Circ. cardiovasc. interv ; 12(11): 1-8, nov., 2019. ilus., graf., tab.
Artículo en Inglés | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1049984

RESUMEN

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)


Asunto(s)
Sistema de Registros , Incidencia , Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter
12.
Int J Artif Organs ; 35(1): 67-76, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22287202

RESUMEN

INTRODUCTION: Coronary artery disease (CAD), along with its main complications such as acute myocardial infarction (AMI) and congestive heart failure (CHF), remains a serious worldwide problem and affects many patients despite the improvement of medical treatment. The possibility of the replacement of the infarcted areas by the re-generation of the myocardial cells has been long discussed and the mobilization of the stem cells from bone marrow (BMCs) to the peripheral blood (PB) induced by cytokines, represents a potential pathway to activate the regenerative process. PATIENTS AND METHODS: We describe BMC mobilization and direct/indirect revascularization in 15 patients operated on for coronary artery bypass grafting (CABG) and/or mitral valve surgery and/or ventricular remodeling combined to multiple trans-myocardial punctures (Sen technique) in ungraftable non-viable fibrotic areas. RESULTS: Peak values of circulating BMCs were recorded between day +4 and day +6. We had no in-hospital (0-30 days) mortality. All the patients were discharged from the ICU after a median period of 2 days while the in-hospital length of stay was 10.5+4.2 days (range 7-21) and all patients were discharged in good clinical condition. There were two sudden deaths over the mid-term, at postoperative day (POD) 32 and 45 respectively. CONCLUSIONS: Our study suggests that the combination of BMC mobilization and CABG may be safely performed. However, considering the small series, final conclusions about the benefit of this procedure must await a larger prospective study comparing the role of cytokines alone, myocardial perforation, and the combination of both.


Asunto(s)
Células de la Médula Ósea/efectos de los fármacos , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Factor Estimulante de Colonias de Granulocitos/administración & dosificación , Factor Estimulante de Colonias de Granulocitos y Macrófagos/administración & dosificación , Insuficiencia Cardíaca/cirugía , Movilización de Célula Madre Hematopoyética , Infarto del Miocardio/cirugía , Miocardio/patología , Células Madre/efectos de los fármacos , Anciano , Terapia Combinada , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/fisiopatología , Esquema de Medicación , Femenino , Fibrosis , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/fisiopatología , Movilización de Célula Madre Hematopoyética/efectos adversos , Movilización de Célula Madre Hematopoyética/mortalidad , Humanos , Inyecciones Subcutáneas , Italia , Tiempo de Internación , Lenograstim , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Proyectos Piloto , Cuidados Preoperatorios , Estudios Prospectivos , Punciones , Proteínas Recombinantes/administración & dosificación , Medición de Riesgo , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
13.
Transplant Rev (Orlando) ; 26(4): 241-5, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22835486

RESUMEN

The end-stage cardiomyopathy is an increasing worldwide problem. Cardiac transplantation lacks sufficient donors to treat all patients, and there is thus debate about alternative strategies. The use of left ventricular assist devices for long-term support is increasing with a positive impact on patient survival. Although there is an ongoing debate regarding the risks and benefits of maintaining pulsatile flow during long-term ventricular assist device support, there has been a significant move towards implantation of continuous flow devices due to the lower surgical morbidity and better long-term reliability of these pumps. The following is a review of the literature on continuous and pulsatile flow for long-term support. Starting from the definition of flow, we analyze the current evidence and consider gastrointestinal complications.


Asunto(s)
Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/estadística & datos numéricos , Corazón Auxiliar/tendencias , Hemodinámica , Humanos , Morbilidad , Flujo Pulsátil , Factores de Riesgo
14.
Coron Artery Dis ; 22(8): 583-4, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21959715

RESUMEN

We present the angiograms of a patient after transmyocardial laser revascularization (TMR), which were performed 10 years before by the application of holmium laser pulses. Thirteen years before the TMR procedure, the patient underwent coronary artery bypass graftings complicated by graft occlusion with no longer possibility of direct revascularization. Then, refractive angina required an alternative approach for symptom relief as the indirect revascularization by the application of the holmium laser pulses. Interestingly, the late angiograms, taken when the patient suffered from effort dyspnea for ongoing left ventricular dysfunction, showed a network of small vessels (absent before the TMR procedure) that supplies blood to the heart with no flow through the coronary arteries because of their complete occlusion. This is a historical presentation of the results of TMR to understand the effects of the indirect revascularization on the blood circulation through the heart over the long-term follow-up.


Asunto(s)
Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/cirugía , Revascularización Transmiocárdica con Láser , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/etiología , Angina de Pecho/cirugía , Circulación Colateral , Circulación Coronaria , Resultado Fatal , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Humanos , Masculino , Valor Predictivo de las Pruebas , Reoperación , Factores de Tiempo , Resultado del Tratamiento
15.
Clin. infect. dis ; 73(11): 3750-e:3758, Dec. 2021. graf, tab
Artículo en Inglés | CONASS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1353336

RESUMEN

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE (CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Asunto(s)
Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter
16.
JAMA ; 316(10): 1083-1092, 2016.
Artículo en Inglés | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1064090

RESUMEN

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients...


Asunto(s)
Endocarditis , Endocarditis Bacteriana , Reemplazo de la Válvula Aórtica Transcatéter
17.
Circulation ; 142(15): 1497-1499, Oct. 2020. graf
Artículo en Inglés | SES-SP, CONASS, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1148174
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA