Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 146(5): 383-397, 2022 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-35722876

RESUMEN

BACKGROUND: Cerebral microbleeds (CMBs) have been observed in healthy elderly people undergoing systematic brain magnetic resonance imaging. The potential role of acute triggers on the appearance of CMBs remains unknown. We aimed to describe the incidence of new CMBs after transcatheter aortic valve replacement (TAVR) and to identify clinical and procedural factors associated with new CMBs including hemostatic measures and anticoagulation management. METHODS: We evaluated a prospective cohort of patients with symptomatic aortic stenosis referred for TAVR for CMBs (METHYSTROKE [Identification of Epigenetic Risk Factors for Ischemic Complication During the TAVR Procedure in the Elderly]). Standardized neurologic assessment, brain magnetic resonance imaging, and analysis of hemostatic measures including von Willebrand factor were performed before and after TAVR. Numbers and location of microbleeds on preprocedural magnetic resonance imaging and of new microbleeds on postprocedural magnetic resonance imaging were reported by 2 independent neuroradiologists blinded to clinical data. Measures associated with new microbleeds and postprocedural outcome including neurologic functional outcome at 6 months were also examined. RESULTS: A total of 84 patients (47% men, 80.9±5.7 years of age) were included. On preprocedural magnetic resonance imaging, 22 patients (26% [95% CI, 17%-37%]) had at least 1 microbleed. After TAVR, new microbleeds were observed in 19 (23% [95% CI, 14%-33%]) patients. The occurrence of new microbleeds was independent of the presence of microbleeds at baseline and of diffusion-weighted imaging hypersignals. In univariable analysis, a previous history of bleeding (P=0.01), a higher total dose of heparin (P=0.02), a prolonged procedure (P=0.03), absence of protamine reversion (P=0.04), higher final activated partial thromboplastin time (P=0.05), lower final von Willebrand factor high-molecular-weight:multimer ratio (P=0.007), and lower final closure time with adenosine-diphosphate (P=0.02) were associated with the occurrence of new postprocedural microbleeds. In multivariable analysis, a prolonged procedure (odds ratio, 1.22 [95% CI, 1.03-1.73] for every 5 minutes of fluoroscopy time; P=0.02) and postprocedural acquired von Willebrand factor defect (odds ratio, 1.42 [95% CI, 1.08-1.89] for every lower 0.1 unit of high-molecular-weight:multimer ratio; P=0.004) were independently associated with the occurrence of new postprocedural microbleeds. New CMBs were not associated with changes in neurologic functional outcome or quality of life at 6 months. CONCLUSIONS: One out of 4 patients undergoing TAVR has CMBs before the procedure and 1 out of 4 patients develops new CMBs. Procedural or antithrombotic management and persistence of acquired von Willebrand factor defect were associated with the occurrence of new CMBs. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02972008.


Asunto(s)
Hemorragia Cerebral , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/epidemiología , Hemorragia Cerebral/etiología , Femenino , Fluoroscopía , Hemostáticos , Humanos , Imagen por Resonancia Magnética , Masculino , Estudios Prospectivos , Calidad de Vida , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Factor de von Willebrand
2.
Circulation ; 143(10): 1043-1061, 2021 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-33683945

RESUMEN

After 15 years of successive randomized, controlled trials, indications for transcatheter aortic valve replacement (TAVR) are rapidly expanding. In the coming years, this procedure could become the first line treatment for patients with a symptomatic severe aortic stenosis and a tricuspid aortic valve anatomy. However, randomized, controlled trials have excluded bicuspid aortic valve (BAV), which is the most frequent congenital heart disease occurring in 1% to 2% of the total population and representing at least 25% of patients 80 years of age or older referred for aortic valve replacement. The use of a less invasive transcatheter therapy in this elderly population became rapidly attractive, and approximately 10% of patients currently undergoing TAVR have a BAV. The U.S. Food and Drug Administration and the "European Conformity" have approved TAVR for low-risk patients regardless of the aortic valve anatomy whereas international guidelines recommend surgical replacement in BAV populations. Given this progressive expansion of TAVR toward younger and lower-risk patients, heart teams are encountering BAV patients more frequently, while the ability of this therapy to treat such a challenging anatomy remains uncertain. This review will address the singularity of BAV anatomy and associated technical challenges for the TAVR procedure. We will examine and summarize available clinical evidence and highlight critical knowledge gaps regarding TAVR utilization in BAV patients. We will provide a comprehensive overview of the role of computed tomography scans in the diagnosis, and classification of BAV and TAVR procedure planning. Overall, we will offer an integrated framework for understanding the current role of TAVR in the treatment of bicuspid aortic stenosis and for guiding physicians in clinical decision-making.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino
3.
Circulation ; 141(4): 243-259, 2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31736356

RESUMEN

BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.


Asunto(s)
Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Masculino , Tasa de Supervivencia
4.
N Engl J Med ; 375(4): 335-44, 2016 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-27464202

RESUMEN

BACKGROUND: Postprocedural aortic regurgitation occurs in 10 to 20% of patients undergoing transcatheter aortic-valve replacement (TAVR) for aortic stenosis. We hypothesized that assessment of defects in high-molecular-weight (HMW) multimers of von Willebrand factor or point-of-care assessment of hemostasis could be used to monitor aortic regurgitation during TAVR. METHODS: We enrolled 183 patients undergoing TAVR. Patients with aortic regurgitation after the initial implantation, as identified by means of transesophageal echocardiography, underwent additional balloon dilation to correct aortic regurgitation. HMW multimers and the closure time with adenosine diphosphate (CT-ADP), a point-of-care measure of hemostasis, were assessed at baseline and 5 minutes after each step of the procedure. Mortality was evaluated at 1 year. A second cohort (201 patients) was studied to validate the use of CT-ADP in order to identify patients with aortic regurgitation. RESULTS: After the initial implantation, HMW multimers normalized in patients without aortic regurgitation (137 patients). Among the 46 patients with aortic regurgitation, normalization occurred in 20 patients in whom additional balloon dilation was successful but did not occur in the 26 patients with persistent aortic regurgitation. A similar sequence of changes was observed with CT-ADP. A CT-ADP value of more than 180 seconds had sensitivity, specificity, and negative predictive value of 92.3%, 92.4%, and 98.6%, respectively, for aortic regurgitation, with similar results in the validation cohort. Multivariable analyses showed that the values for HMW multimers and CT-ADP at the end of TAVR were each associated with mortality at 1 year. CONCLUSIONS: The presence of HMW-multimer defects and a high value for a point-of-care hemostatic test, the CT-ADP, were each predictive of the presence of aortic regurgitation after TAVR and were associated with higher mortality 1 year after the procedure. (Funded by Lille 2 University and others; ClinicalTrials.gov number, NCT02628509.).


Asunto(s)
Adenosina Difosfato/sangre , Insuficiencia de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/diagnóstico , Reemplazo de la Válvula Aórtica Transcatéter , Factor de von Willebrand/análisis , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/mortalidad , Biomarcadores/sangre , Femenino , Hemostasis/fisiología , Humanos , Masculino , Análisis Multivariante , Pruebas en el Punto de Atención , Complicaciones Posoperatorias/sangre , Curva ROC , Sensibilidad y Especificidad , Factor de von Willebrand/química
6.
Catheter Cardiovasc Interv ; 87(4): 797-804, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26424679

RESUMEN

OBJECTIVES: We compared the outcomes of transcatheter aortic valve implantation (TAVI) in three different aortic stenosis syndromes: paradoxical low-flow low-gradient aortic stenosis (PLFLG), high-gradient aortic stenosis (HGAS), and low ejection fraction low-gradient severe aortic stenosis (LEF-LG). BACKGROUND: Outcomes for PLFLG patients after TAVI procedure are not well known. METHODS: Between 2010 and 2013, patients with severe (indexed aortic valve area iAVA≤0.6 cm(2)/m(2)) symptomatic aortic stenosis were consecutively referred to our institution for TAVI because of multiple comorbidities and excessive surgical risk. About 262 patients were split into three groups as following, PLFLG: mean gradient MG≤40 mm Hg, stroke volume index SVI≤35 mL/m(2), ejection fraction EF≥55%, valvuloarterial impedance Zva>4.5 mm Hg/mL/m(2), maximal aortic jet velocity MaxV<4 m/s; LEF-LG: MG≤40 mm Hg, MaxV<4 m/s, EF≤50%, SVI≤35 mL/m(2); and HGAS: MaxV>4 m/s, MG>40 mm Hg, EF>55%. The primary endpoint of our study was to evaluate mid-term global and cardiovascular mortalities; secondary endpoints included recommended VARC-2 variables. RESULTS: PLFLG (n = 31) mid-term survival was similar to HGAS (n = 172) (mean follow-up = 13.2 months [4.6-26]). Conversely LEF-LG patients (n = 59) displayed significant higher rates of all-cause (P = 0.01) and cardiovascular mortalities (P = 0.05). Postprocedural outcomes (VARC-2 criteria) were similar in the PLFLG and HGAS groups except regarding major bleeding (P = 0.02), while the LEF-LG group had more congestive heart failure and a higher BNP before discharge (both P < 0.001) than the other groups. 30-days deaths were significantly more frequent in LEF-LG and PLFLG in comparison to HGAS (P = 0.03). CONCLUSION: As opposed to LEF-LG patients, mid-term prognosis after TAVI procedure in PLFLG patients is similar to HGAS patients despite higher perioperative mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Masculino , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Circulation ; 130(7): 554-64, 2014 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-24928681

RESUMEN

BACKGROUND: Obesity and diabetes mellitus are independently associated with the development of heart failure. In this study, we determined the respective effects of obesity, insulin resistance, and diabetes mellitus on the intrinsic contraction and mitochondrial function of the human myocardium before the onset of cardiomyopathy. METHODS AND RESULTS: Right atrial myocardium was obtained from 141 consecutive patients presenting no sign of cardiomyopathy. We investigated ex vivo isometric contraction, mitochondrial respiration and calcium retention capacity, and respiratory chain complex activities and oxidative stress status. Diabetes mellitus was associated with a pronounced impairment of intrinsic contraction, mitochondrial dysfunction, and increased myocardial oxidative stress, regardless of weight status. In contrast, obesity was associated with less pronounced contractile dysfunction without any significant perturbation of mitochondrial function or oxidative stress status. Tested as continuous variables, glycated hemoglobin A1C, but neither body mass index nor the insulin resistance index (homeostasis model assessment-insulin resistance), was independently associated with cardiac mitochondrial function. Furthermore, diabetes mellitus was associated with cardiac mitochondrial network fragmentation and significantly decreased expression of the mitochondrial fusion related protein MFN1. Myocardial MFN1 content was inversely proportional to hemoglobin A1C. CONCLUSION: Worsening of intrinsic myocardial contraction in the transition from obesity to diabetes mellitus is likely related to worsening of cardiac mitochondrial function because impaired mitochondrial function and dynamics and contractile dysfunction are observed in diabetic patients but not in "metabolically healthy" obese patients at early stage in insulin resistance.


Asunto(s)
Diabetes Mellitus Tipo 2/fisiopatología , Mitocondrias Cardíacas/fisiología , Contracción Miocárdica/fisiología , Obesidad/fisiopatología , Anciano , Función del Atrio Derecho/fisiología , Glucemia/metabolismo , Diabetes Mellitus Tipo 2/sangre , Femenino , Humanos , Resistencia a la Insulina/fisiología , Masculino , Persona de Mediana Edad , Obesidad/sangre , Técnicas de Cultivo de Órganos , Estudios Prospectivos
9.
EuroIntervention ; 17(8): e680-e687, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34105511

RESUMEN

BACKGROUND: Balloon aortic valvuloplasty (BAV) has been proposed as a therapeutic option in patients suffering from severe aortic stenosis (SAS) who need urgent non-cardiac surgery (NCS). Whether this strategy is better than medical therapy in this very specific population is unknown. AIMS: We aimed to evaluate the clinical benefit of an invasive strategy (IS) with preoperative BAV in patients with SAS requiring urgent NCS. METHODS: From 2011 to 2019, a registry conducted in two centres included 133 patients with SAS undergoing urgent NCS, of whom 93 underwent preoperative BAV (IS) and 40 a conservative strategy (CS) without BAV. All analyses were adjusted for confounding using inverse probability of treatment weighting (IPTW) (10 clinical and anatomical variables). RESULTS: The primary outcome was MACE at one-month follow-up after NCS including mortality, heart failure, and other cardiovascular outcomes. In patients managed conservatively, occurrence of MACE was 20.0% (n=8) and death was 10.0% (n=4) at 1 month. In patients undergoing BAV, the occurrence of MACE was 20.4% (n=19) and death was 5.4% (n=5) at 1 month. Among patients undergoing conservative management, all events were observed after NCS while, in patients undergoing BAV, 12.9% (n=12) had events between BAV and NCS including 3 deaths, and 7.5% (n=7) had events after NCS including 2 deaths. In IPTW propensity analyses, the incidence of the primary outcome (20.4% vs 20.0%; OR 0.93, 95% CI: 0.38-2.29) and three-month survival (89.2% vs 90.0%; IPTW-adjusted HR 0.90, 95% CI: 0.31-2.60) were similar in both groups. CONCLUSIONS: Patients with SAS managed conservatively before urgent NCS are at high risk of events. A systematic invasive strategy using BAV does not provide a significant improvement in clinical outcome.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Arch Cardiovasc Dis ; 114(8-9): 537-549, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33895105

RESUMEN

BACKGROUND: Transfemoral percutaneous transcatheter aortic valve implantation (TF-TAVI) is a safe, reproducible and established procedure, mainly performed under local anaesthesia, which is mostly administered and monitored by a dedicated anaesthesia team (regular approach). Our centre has developed a standardized pathway of care, and eligible patients are selected for a minimalist TF-TAVI, entirely managed by operators without the presence of the anaesthesia team in the operating room, like most interventional coronary procedures ("percutaneous coronary intervention-like" approach [PCI approach]). AIM: To compare the safety and efficacy of TF-TAVI performed with the PCI approach versus the regular approach. METHODS: The analysis population comprised all patients who underwent TF-TAVI with the PCI or regular approach in our institution from November 2016 to July 2019. The two co-primary endpoints were early safety composite and early efficacy composite at 30days as defined by the Valve Academic Research Consortium-2. The PCI (n=137) and Regular (n=221) approaches were compared using the propensity score based method of inverse probability of treatment weighting. RESULTS: No differences were observed after comparison of TAVI performed with the PCI or regular approach regarding the composite safety endpoint (7.3% vs. 11.3%; odds ratio 0.63, 95% confidence interval 0.37 to 1.07; P=0.086) or the composite efficacy endpoint (4.4% vs. 6.3%; odds ratio 0.78, 95% confidence interval 0.41 to 1.49; P=0.45). CONCLUSIONS: This study suggests that the efficacy and safety of TF-TAVI entirely managed by a PCI approach for selected patients are not different to those when TF-TAVI is performed with the attendance of a full anaesthesia care team. The PCI approach appears to be a safe and efficient clinical pathway, providing an appropriate and rational utilization of anaesthesiology resources, and could be used for the majority of TF-TAVI procedures.


Asunto(s)
Estenosis de la Válvula Aórtica , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Fluoroscopía , Humanos , Intervención Coronaria Percutánea/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
11.
EuroIntervention ; 17(1): 23-31, 2021 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-32624457

RESUMEN

The proposed 2020 Core Curriculum for Percutaneous Cardiovascular Interventions aims to provide an updated European consensus that defines the level of experience and knowledge in the field of percutaneous cardiovascular intervention (PCI). It promotes homogenous education and training programmes among countries, and is the cornerstone of the new EAPCI certification, designed to support the recognition of competencies at the European level and the free movement of certified specialists in the European Community. It is based on a thorough review of the ESC guidelines and of the EAPCI textbook on percutaneous interventional cardiovascular medicine. The structure of the current core curriculum evolved from previous EAPCI core curricula and from the "2013 core curriculum of the general cardiologist" to follow the current ESC recommendations for core curricula. In most subject areas, there was a wide - if not unanimous - consensus among the task force members on the training required for the interventional cardiologist of the future. The document recommends that acquisition of competence in interventional cardiology requires at least two years of postgraduate training, in addition to four years devoted to cardiology. The first part of the curriculum covers general aspects of training and is followed by a comprehensive description of the specific components in 54 chapters. Each of the chapters includes statements of the objectives, and is further subdivided into the required knowledge, skills, behaviours, and attitudes.


Asunto(s)
Cardiología , Intervención Coronaria Percutánea , Cardiología/educación , Consenso , Curriculum , Europa (Continente) , Humanos
12.
Lancet Reg Health Eur ; 2: 100030, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34173627

RESUMEN

BACKGROUND: A reduction of admission for MI has been reported in most countries affected by COVID-19. No clear explanation has been provided. METHODS: To report the incidence of myocardial infarction (MI) admission during COVID-19 pandemic and in particular during national lockdown in two unequally affected French provinces (10-million inhabitants) with a different media strategy, and to describe the magnitude of MI incidence changes relative to the incidence of COVID-19-related deaths. A longitudinal study to collect all MIs from January 1 until May 17, 2020 (study period) and from the identical time period in 2019 (control period) was conducted in all centers with PCI-facilities in northern "Hauts-de-France" province and western "Pays-de-la-Loire" Province. The incidence of COVID-19 fatalities was also collected. FINDINGS: In "Hauts-de-France", during lockdown (March 18-May 10), 1500 COVID-19-related deaths were observed. A 23% decrease in MI-IR (IRR=0.77;95%CI:0.71-0.84, p<0.001) was observed for a loss of 272 MIs (95%CI:-363,-181), representing 18% of COVID-19-related deaths. In "Pays-de-la-Loire", 382 COVID-19-related deaths were observed. A 19% decrease in MI-IR (IRR=0.81; 95%CI=0.73-0.90, p<0.001) was observed for a loss of 138 MIs (95%CI:-210,-66), representing 36% of COVID-19-related deaths. While in "Hauts-de-France" the MI decline started before lockdown and recovered 3 weeks before its end, in "Pays-de-la-Loire", it started after lockdown and recovered only by its end. In-hospital mortality of MI patients was increased during lockdown in both provinces (5.0% vs 3.4%, p=0.02). INTERPRETATION: It highlights one of the potential collateral damages of COVID-19 outbreak on cardiovascular health with a dramatic reduction of MI incidence. It advocates for a careful and weighted communication strategy in pandemic crises. FUNDING: The study was conducted without external funding.

13.
J Am Soc Echocardiogr ; 33(12): 1454-1464, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32919856

RESUMEN

BACKGROUND: Impaired left ventricular (LV) speckle-tracking-derived global longitudinal strain (GLS) magnitude (GLS worse than 14.7%) has been associated with poor outcome in patients with severe aortic stenosis (AS) and preserved LV ejection fraction (EF). OBJECTIVES: To test the hypothesis that GLS magnitude ≤ 15% obtained with vendor-independent speckle-tracking strain software may be able to identify patients with severe AS who are at higher risk of death, despite preserved LVEF and no or mild symptoms. METHODS: GLS was retrospectively obtained in 332 patients with severe AS (aortic valve area indexed [AVAi] < 0.6 cm2/m2), no or mild symptoms, and LVEF ≥ 50%. Absolute values of GLS were collected. Survival analyses were carried out to study the impact of GLS magnitude on all-cause mortality. RESULTS: During a median follow-up period of 42 (37-46) months, 105 patients died. On multivariate analysis, and after adjustment of known clinical and/or echocardiographic predictors of outcome and aortic valve replacement as a time-dependent covariate, GLS magnitude ≤ 15% was independently associated with mortality during follow-up (all P < .01). Adding GLS magnitude ≤ 15% (adjusted hazard ratio = 1.99 [1.17-3.38], P = .011) to a multivariate model including clinical and echocardiographic variables of prognostic importance (aortic valve replacement, aortic valve area, LV stroke volume index < 30 mL/m2, and LVEF<60%) improved the predictive performance with improved global model fit, reclassification, and better discrimination. After propensity score matching (n = 196), increased risk of mortality persisted among patients with GLS magnitude ≤ 15% compared with those with GLS > 15% (hazard ratio = 2.10; 95% confidence interval, 1.20-3.68; P = .009). CONCLUSIONS: In this series of patients with severe AS, no or mild symptoms, and LVEF ≥ 50%, GLS obtained with vendor-independent speckle-tracking strain software was an effective tool to identify patients with a poor outcome. Detection of myocardial dysfunction by identifying GLS magnitude < 15% in patients with severe AS, no or mild symptoms, and LVEF ≥ 50%, can aid in risk assessment.


Asunto(s)
Estenosis de la Válvula Aórtica , Disfunción Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Humanos , Pronóstico , Estudios Retrospectivos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
14.
EuroIntervention ; 16(10): 842-849, 2020 11 20.
Artículo en Inglés | MEDLINE | ID: mdl-32310129

RESUMEN

AIMS: No randomised study comparing the outcomes of transcarotid (TC) and transaxillary (TAx) TAVR has been conducted to date. The purpose of this study was to understand which approach should be the preferred alternative by comparing their outcomes using a propensity-matched comparison in a French multicentre registry. METHODS AND RESULTS: From 2010 to 2018, a French multicentre prospective registry included 502 patients, with 374 undergoing TC-TAVR and 128 TAx-TAVR for symptomatic aortic stenosis. Patients treated through TAx access were matched 1:2 with patients treated through the TC route by using a propensity score (20 clinical, anatomical and procedural variables) and by date of the procedure. The first outcome was mortality at one-month follow-up. The second outcome was one-month stroke/transient ischaemic attack (TIA). In propensity-matched analyses, the incidence of the primary outcome was similar in the TAx and TC groups (TAx 5.5% vs TC 4.5%, OR 1.23, 95% CI: 0.40-3.70). The secondary outcome was similar in TAx (3.2%) and TC (6.8%, OR 0.52, 95% CI: 0.14-1.84). Minor bleeding (2.7% vs 9.3%, OR 0.26, 95% CI: 0.07-0.92) and main access haematoma (3.6% vs 10.3%, OR 0.034, 95% CI: 0.09-0.92) were significantly more frequent with the TC access. One-month clinical efficacy and safety and one-year mortality did not differ according to the different routes. CONCLUSIONS: One-month mortality, one-month stroke/TIA and one-year mortality are similar with TAx-TAVR and TC-TAVR. However, TC-TAVR is accompanied by more minor bleeding and main access haematoma compared with the transaxillary route.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
J Am Heart Assoc ; 9(6): e014916, 2020 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-32172643

RESUMEN

Background Ultrasound (US) guidance provides the unique opportunity to control the puncture zone of the artery during transfemoral transcatheter aortic valve replacement and may decrease major vascular complications (VC) and life-threatening or major bleeding complications. This study aimed to evaluate the clinical impact of US guidance using a propensity score-matched comparison. Methods and Results US guidance was implemented as the default approach for all transfemoral transcatheter aortic valve replacement cases in our institution in June 2013. We defined 3 groups of consecutive patients according to the method of puncture (fluoroscopic/US guidance) and the use of a transcatheter heart valve. Patients in the US-guided second-generation group (Sapien XT [Edwards Lifesciences, Irvine, CA], Corevalve [Medtronic, Dublin, Ireland]) were successfully 1:1 matched with patients in the fluoroscope-guided second-generation group (n=95) with propensity score matching. In a second analysis we described the consecutive patients of the US-guided third-generation group (Evolut-R [Medtronic], Sapien 3 [Edwards Lifesciences], n=308). All vascular and bleeding complications were reduced in the US-guided second-generation group compared with the fluoroscope-guided second-generation group: VC (16.8% versus 6.3%; P=0.023); life-threatening or major bleeding (22.1% versus 6%; P=0.004); and VC related to vascular access (12.6% versus 4.2%; P=0.052). In the US-guided third-generation group the rates of major VC and life-threatening or major bleeding were 3.2% (95% CI, 1.6% to 5.9%) and 3.6% (95% CI, 1.8% to 6.3%). In the overall population (n=546), life-threatening or major bleeding was associated with a 1.7-fold increased mortality risk (P=0.02). Conclusions We demonstrated that US guidance effectively reduced VC and bleeding complications for transfemoral transcatheter aortic valve replacement and should be considered the standard puncture method. Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT02628509.


Asunto(s)
Cateterismo Periférico , Arteria Femoral/diagnóstico por imagen , Hemorragia Posoperatoria/prevención & control , Radiografía Intervencional , Reemplazo de la Válvula Aórtica Transcatéter , Ultrasonografía Intervencional , Lesiones del Sistema Vascular/prevención & control , Anciano , Anciano de 80 o más Años , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Femenino , Arteria Femoral/lesiones , Fluoroscopía , Humanos , Masculino , Hemorragia Posoperatoria/etiología , Hemorragia Posoperatoria/mortalidad , Puntaje de Propensión , Punciones , Radiografía Intervencional/efectos adversos , Radiografía Intervencional/mortalidad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos , Ultrasonografía Intervencional/mortalidad , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/mortalidad
16.
J Am Coll Cardiol ; 73(9): 1078-1088, 2019 03 12.
Artículo en Inglés | MEDLINE | ID: mdl-30846101

RESUMEN

For decades, numerous observations have shown an intimate relationship between von Willebrand factor (VWF) multimer profile and heart valve diseases (HVD). The current knowledge of the unique biophysical properties of VWF helps us to understand the longstanding observations concerning the bleeding complications in patients with severe HVD. Not only does the analysis of the VWF multimer profile provide an excellent evaluation of HVD severity, it is also a strong predictor of clinical events. Also of importance, VWF responds within minutes to any significant change in hemodynamic valve status, making it an accurate marker of the quality of surgical and transcatheter therapeutic interventions. The authors provide in this review a practical, comprehensive, and evidence-based framework of the concept of VWF as a biomarker in HVD, advocating for its implementation into the clinical decision-making process besides usual clinical and imaging evaluation. They also delineate critical knowledge gaps and research priorities to definitely validate this concept.


Asunto(s)
Toma de Decisiones Clínicas , Manejo de la Enfermedad , Enfermedades de las Válvulas Cardíacas/sangre , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factor de von Willebrand/metabolismo , Biomarcadores/sangre , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Índice de Severidad de la Enfermedad
17.
EuroIntervention ; 14(5): e519-e525, 2018 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-29741481

RESUMEN

AIMS: The aim of the study was to assess the outcomes of balloon aortic valvuloplasty (BAV) as a rescue therapy in patients with cardiogenic shock (CS) related to severe aortic stenosis (AS). METHODS AND RESULTS: Forty-four consecutive patients, n=31 with hypotensive CS (HCS) and n=13 with non-hypotensive CS (NHCS) due to acutely decompensated severe AS, from two centres were treated with urgent BAV. The composite primary endpoint was mortality or recurrent CS at one-year follow-up. These patients (77.3±8.1 years old; 75% male) had a mean EuroSCORE II of 41.6±13.7%. One-month mortality was 47%. Twelve patients (27%) had either a staged TAVR (n=10) or surgical aortic valve replacement (SAVR) (n=2) with a median delay of 79 days after BAV: n=6 (19%) in the HCS subgroup and n=6 (46%) in the NHCS population (p=0.06). At one year, the rate of composite all-cause death or recurrent CS was 75% and significantly higher in the HCS subgroup (83% vs. 53%; p=0.03). Overall one-year mortality was 70% (n=31) with a trend for a better prognosis in NHCS patients (54% vs. 77%; p=0.09). Univariate predictive factors of the primary endpoint included preoperative dose of dobutamine >5 microg/kg/min (100% vs. 57%; p=0.001) and delayed BAV >48 hrs (90% vs. 59%; p=0.01). CONCLUSIONS: Despite the initial success of urgent BAV, morbidity and mortality of CS related to severe AS remain high and directly related to the time of the valvuloplasty. Performing BAV before or within 48 hours of starting inotropic agents appears to be key to survival.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Choque Cardiogénico/etiología , Anciano , Anciano de 80 o más Años , Válvula Aórtica , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
18.
JACC Cardiovasc Interv ; 11(4): 354-365, 2018 02 26.
Artículo en Inglés | MEDLINE | ID: mdl-29471949

RESUMEN

OBJECTIVES: This study sought to prospectively assess the impact of routine invasive physiology at the time of angiography on reclassification of therapeutic management of multivessel disease (MVD) patients, and to assess how implementation of instantaneous wave-free ratio (iFR) alters the process. BACKGROUND: Routine invasive physiology in intermediate coronary lesions at the time of diagnostic angiography, primarily in patients with single-vessel disease and using fractional flow reserve (FFR), reclassifies coronary revascularization management in 26% to 44% of patients. The role of invasive physiology in patients with MVD is unclear. METHODS: In 18 centers, 484 patients undergoing diagnostic angiography disclosing MVD with lesions >40% by visual assessment were included. Investigators were asked to prospectively define their initial management strategy based on angiography and clinical information. Invasive physiology (FFR or iFR driven) was then performed and final strategy defined. Initial and final vessel, patient, procedural, and overall management were described. Reclassification was defined as the difference between initial and final strategy. RESULTS: The majority of patients were clinically stable (82.2%). Two- and 3-vessel disease was present in 73.3% and 26.7% of patients, respectively. Lesions investigated were "intermediate" with median percent stenosis, median FFR, and median iFR at 60% (interquartile range [IQR]: 50% to 70%), 0.84 (IQR: 0.78 to 0.90), and 0.92 (IQR: 0.85 to 0.96), respectively. Vessel management was reclassified by physiology in 30.0% (249 of 828) of vessels. Patient and overall management were reclassified in 26.9% (130 of 484) and 45.7% (211 of 484) of patients, respectively. Reclassification rates were high irrespective of initial management (optimal medical therapy, percutaneous coronary intervention, or coronary artery bypass grafting), and performance and results of pre-procedural noninvasive tests. Reclassification of overall management in particular increased with the number of vessels investigated (1 vessel: 37.3%; 2 vessels: 45.0%; 3 vessels: 66.7%; p = 0.002). Incorporating iFR in the decision process was associated with investigation of more vessels (p = 0.04) and higher reclassification (p = 0.0001). CONCLUSIONS: In patients with MVD and intermediate coronary lesions, invasive physiology at time of angiography reclassifies revascularization strategy in a large proportion of cases (26.9%) and investigation of more vessels is associated with higher reclassification rates.


Asunto(s)
Cateterismo Cardíaco , Toma de Decisiones Clínicas , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Técnicas de Apoyo para la Decisión , Reserva del Flujo Fraccional Miocárdico , Revascularización Miocárdica/clasificación , Anciano , Enfermedad de la Arteria Coronaria/clasificación , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/clasificación , Estenosis Coronaria/terapia , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos
19.
Arch Cardiovasc Dis ; 111(11): 686-701, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29861294

RESUMEN

BACKGROUND: Coronary artery disease (CAD) is the leading cause of systolic heart failure (HF). Cardiac magnetic resonance imaging (CMR) is a non-invasive technique that detects a myocardial infarction scar as subendocardial or transmural late gadolinium enhancement (st-LGE). AIM: We sought to evaluate whether a lack of st-LGE could rule out CAD in new-onset systolic HF of unknown aetiology. METHODS: We included 232 consecutive patients with new-onset HF and left ventricular ejection fraction ≤35% who underwent both coronary angiography and CMR to assess HF aetiology. CAD was defined as the presence of coronary artery stenosis≥50% on a coronary angiogram. We assessed sensitivity, specificity, and positive and negative likelihood ratios (PLR and NLR) of the presence of st-LGE to detect underlying CAD. A complementary meta-analysis of 11 studies (including ours) was also performed. RESULTS: In our study, 49 (21.1%) patients had CAD. The sensitivity and specificity of the presence of st-LGE to detect CAD were 69 and 92%, respectively. PLR and NLR were 8.47 and 0.33, respectively. In the meta-analysis, 1227 patients were included, and the prevalence of CAD ranged from 19.2 to 68.3%. Sensitivity, specificity, PLR and NLR were 87% (95% confidence interval [CI] 0.80-0.92), 93% (95% CI 0.89-0.96), 12.91 (95% CI 7.70-21.64) and 0.14 (95% CI 0.09-0.22), respectively. Altogether, 55 patients presented CAD with no st-LGE; inversely, 75 patients presented st-LGE with no CAD. CONCLUSION: With a CMR specificity of 93%, the absence of st-LGE rules out significant underlying CAD in patients with systolic HF of unknown aetiology in most cases.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Insuficiencia Cardíaca Sistólica/etiología , Imagen por Resonancia Magnética , Adulto , Anciano , Medios de Contraste/administración & dosificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/complicaciones , Estenosis Coronaria/fisiopatología , Femenino , Insuficiencia Cardíaca Sistólica/diagnóstico , Insuficiencia Cardíaca Sistólica/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Sistema de Registros , Reproducibilidad de los Resultados , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Función Ventricular Izquierda
20.
J Am Coll Cardiol ; 71(19): 2106-2118, 2018 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-29747831

RESUMEN

BACKGROUND: The main risk factor for bleeding in patients with continuous-flow mechanical circulatory support (CF-MCS) is the acquired von Willebrand factor (VWF) defect related to the high shear-stress forces developed by these devices. Although a higher bleeding rate has been reported in CF-MCS recipients who had reduced pulsatility, the relation between pulsatility and the VWF defect has never been studied. OBJECTIVES: The purpose of this study was to investigate the relation between pulsatility and VWF under CF-MCS. METHODS: We assessed the effect of 2 CF-MCS on VWF multimer degradation in a mock circulatory loop (model 1). Using these devices, we investigated in a dose-effect model (model 2) 3 levels of pulsatility in 3 groups of swine. In a cross-over model (model 3), we studied the effects of sequential changes of pulsatility on VWF. We reported the evolution of VWF multimerization in a patient undergoing serial CF-MCS and/or pulsatile-MCS. RESULTS: We demonstrated the proteolytic degradation of VWF multimers by high shear CF-MCS in a circulatory loop without pulsatility. We observed both in swine models and in a patient that the magnitude of the VWF degradation is modulated by the pulsatility level in the high shear-stress level condition, and that the restoration of pulsatility is a trigger for the endothelial release of VWF. CONCLUSIONS: We demonstrated that the VWF defect reflects the balance between degradation induced by the shear stress and the endothelial release of new VWF triggered by the pulsatility. This modulation of VWF levels could explain the relationship between pulsatility and bleeding observed in CF-MCS recipients. Preservation of pulsatility may be a new target to improve clinical outcomes of patients.


Asunto(s)
Presión Arterial/fisiología , Circulación Extracorporea/tendencias , Corazón Auxiliar/tendencias , Flujo Pulsátil/fisiología , Choque Cardiogénico/terapia , Factor de von Willebrand/metabolismo , Animales , Biomarcadores/sangre , Circulación Extracorporea/efectos adversos , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Choque Cardiogénico/sangre , Choque Cardiogénico/fisiopatología , Estrés Mecánico , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA