Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Heart Lung Circ ; 26(2): 114-121, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27617370

RESUMEN

Recent advances have caused a major shift in the way ST-elevation myocardial infarctions are managed. This review explores the pharmacological and interventional techniques that have evidence for improving outcomes and the landmark trials that have sparked change. The new P2Y12 inhibitors, ticagrelor and prasugrel, have been shown to be superior to clopidogrel in STEMI patients undergoing primary percutaneous coronary intervention. Concurrently, many technical aspects of percutaneous coronary intervention have been further clarified by trial data, with bare-metal stents, routine thrombus aspiration and femoral access showing evidence of inferiority. Ongoing trials will provide more information on the role of non-culprit lesion PCI, bioresorbable vascular scaffolds, mechanical devices in persistent ischaemia and early automatic implantable cardioverter-defibrillators for inducible ventricular tachycardia.


Asunto(s)
Implantes Absorbibles , Adenosina/análogos & derivados , Prótesis Vascular , Intervención Coronaria Percutánea , Clorhidrato de Prasugrel/uso terapéutico , Agonistas del Receptor Purinérgico P2Y/uso terapéutico , Infarto del Miocardio con Elevación del ST/terapia , Stents , Adenosina/uso terapéutico , Humanos , Ticagrelor
4.
Int J Nurs Pract ; 17(5): 525-33, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21939485

RESUMEN

Automatic devices are used to take postural blood pressures in the emergency department despite research proving their inaccuracy in taking single blood pressures. This study assessed the accuracy of an automatic device compared with a manual aneroid reference standard for determining orthostatic hypotension and postural drops at triage. Supine and standing blood pressures were taken with an automatic and a manual device in a sequential and random order, and postural drops were calculated. The manual device indicated 10/150 emergency department patients had orthostatic hypotension (7%) and the automatic device detected this with a sensitivity of 30% and a specificity of 91%. The automatic-manual differences were clinically significant in 13% of systolic drops and 37% of diastolic drops. Findings suggest that automatic devices cannot reliably detect or rule out orthostatic hypotension, indicating that triage nurses need to use manual devices to take accurate postural blood pressures for optimal patient care.


Asunto(s)
Automatización , Servicio de Urgencia en Hospital/organización & administración , Postura , Humanos
5.
BMJ Case Rep ; 14(4)2021 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-33827876

RESUMEN

This case study is a rare example of cardiac hydatidosis in a high-income country, where a middle-aged man presented with a ruptured right ventricular cyst causing anaphylaxis, pulmonary emboli and dissemination of Echinococcus throughout the lung. He survived the cyst rupture and underwent cardiac surgery but had incomplete resection and experienced progressive cardiopulmonary hydatidosis despite antihelminthic therapy. As a result, he experienced an array of cardiopulmonary sequelae over his lifespan. This case report highlights rare clinical manifestations of hydatid disease and potential complications of its treatment.


Asunto(s)
Antihelmínticos , Equinococosis , Echinococcus , Animales , Antihelmínticos/uso terapéutico , Equinococosis/complicaciones , Equinococosis/diagnóstico por imagen , Equinococosis/terapia , Humanos , Pulmón , Masculino , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA