Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Doc Ophthalmol ; 146(3): 257-266, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37219642

RESUMEN

PURPOSE: Diopsys® NOVA™ is a novel full-field electroretinography (ffERG) device that can make rapid measurements of retinal electrophysiologic function. Diagnosys® Espion 2™ is a clinical gold-standard ERG device. This study aimed to investigate whether light-adapted Diopsys® NOVA™ fixed-luminance flicker ffERG magnitude and implicit time (converted from phase) measurements correlate with light-adapted Diagnosys® Espion 2™ flicker ffERG amplitude and implicit time measurements, respectively. METHODS: Twelve patients (22 eyes) with various retinal and uveitic diseases underwent light-adapted Diagnosys® Espion 2™ and Diopsys® NOVA™ fixed-luminance flicker testing. Diopsys® magnitude and implicit time (converted from phase) measurements were compared to Diagnosys® amplitude and implicit time measurements, and a Pearson correlation was used to evaluate any existing correlation. Groups were also compared using generalized estimating equations. Bland-Altman plots were utilized to determine agreement between the comparison groups. RESULTS: Age of patients ranged from 14 to 87 years. 58% (n = 7/12) of patients were female. A significant, positive correlation (r = 0.880, P < 0.001) was observed between magnitude (Diopsys®) and amplitude (Diagnosys®) measurements. Amplitude increases by 6.69 µV for each 1 µV increase in Magnitude (p-value < 0.001). A statistically significant, strong positive correlation was observed between Diopsys® implicit time measurements (converted from phase) and Diagnosys® implicit time measurements (r = 0.814, p-value < 0.001). For each 1 ms increase in Diopsys® implicit time, Diagnosys® implicit time increases by 1.13 ms (p-value < 0.001). CONCLUSIONS: There is a statistically significant positive correlation between light-adapted Diopsys® NOVA™ fixed-luminance flicker amplitude and Diagnosys® flicker magnitude values. Additionally, there is a statistically significant positive correlation between Diopsys® NOVA™ fixed-luminance flicker implicit time (converted from phase) and Diagnosys® flicker implicit time values. These results imply that the Diopsys® NOVA™ module, which utilizes the nonstandard shortened International Society for Clinical Electrophysiology of Vision (ISCEV) ERG protocol, can produce reliable light-adapted flicker ffERG measurements.


Asunto(s)
Electrorretinografía , Retina , Humanos , Femenino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Electrorretinografía/métodos , Estimulación Luminosa
2.
Ocul Immunol Inflamm ; 31(9): 1819-1824, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36170559

RESUMEN

PURPOSE: To evaluate the correlation between longitudinal changes in aqueous flare measured by laser flare photometer (LFP), best-corrected visual acuity (BCVA), and clinical grade using both Standardization of Uveitis Nomenclature (SUN) and modified SUN (MSUN) scales uveitis patients. METHODS: Patients were classified according to both SUN and MSUN grading scales. LFP measurements were acquired (Kowa FM-700) at each visit. Mean change in LFP was assessed longitudinally, comparing with those in visual acuity, SUN, and MSUN grading scales. RESULTS: Mean change in LFP was correlated to those in BCVA (p = .018), SUN scale (p < .001), and MSUN scale (p = .008). Cases within same initial SUN (0 and 1+) and MSUN (0.5+ and 1+) grades and different longitudinal flare prognosis (decreased/unchanged/increased) had significantly different initial LFP values (all p < .05). CONCLUSIONS: LFP measurement is beneficial in monitoring inflammatory activity. Cases of identical clinical flare scores with different clinical prognosis may be predicted by LFP.


Asunto(s)
Uveítis Anterior , Uveítis , Humanos , Humor Acuoso , Uveítis/diagnóstico , Fotometría , Rayos Láser
3.
Expert Opin Biol Ther ; 22(10): 1275-1291, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35818801

RESUMEN

INTRODUCTION: Diabetic retinopathy (DR) is one of the most frequent microvascular complications of diabetes that can lead to blindness. Laser treatment has been the gold standard treatment for diabetic macular edema (DME) and proliferative diabetic retinopathy (PDR) for many years. Recently, the role of vascular endothelial growth factor (VEGF) has been established in the pathogenesis of DR, and the use of intravitreal anti-VEGF therapy has gained popularity for the management of DR. AREAS COVERED: This review includes a brief overview of the efficacy and safety of currently available (bevacizumab, ranibizumab, and aflibercept) and potential future (brolucizumab, faricimab, and KSI-301) anti-VEGF agents in patients with DR based mainly on publicly available data from phase 1, 2 and 3 clinical trials. EXPERT OPINION: Clinical trials investigating the efficacy of intravitreal bevacizumab, ranibizumab, and aflibercept injections demonstrated favorable functional and anatomical outcomes in patients with DME. Moreover, the use of these anti-VEGF agents showed a significant improvement in the severity of DR. Recent clinical research for future anti-VEGF molecules aims to provide higher target-protein binding affinity and prolonged therapeutic effect. Brolucizumab, faricimab, and KSI-301 are three novel anti-VEGF agents that demonstrate promising data for the management of DME and potentially DR.


Asunto(s)
Diabetes Mellitus , Retinopatía Diabética , Edema Macular , Humanos , Retinopatía Diabética/tratamiento farmacológico , Ranibizumab , Edema Macular/tratamiento farmacológico , Edema Macular/etiología , Bevacizumab/uso terapéutico , Factor A de Crecimiento Endotelial Vascular , Inhibidores de la Angiogénesis/efectos adversos , Receptores de Factores de Crecimiento Endotelial Vascular , Anticuerpos Monoclonales/uso terapéutico , Proteínas Recombinantes de Fusión/efectos adversos , Inyecciones Intravítreas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA